| Product Type | Handheld Oscilloscope/Multimeter (ScopeMeter) |
| Brand | Fluke |
| Model | ScopeMeter 190-202 |
| Bandwidth | 200 MHz |
| Number of Channels | 2 |
| Sample Rate | Up to 5 GS/s (repetitive), 1.25 GS/s (single shot) |
| Input Range | 5 mV/div to 100 V/div |
| Multimeter Functions | AC/DC voltage, current, resistance, continuity, diode, capacitance, frequency |
| Display | 6.5 inch (165 mm) color LCD with backlight |
| Dimensions (HxWxD) | 265 x 190 x 60 mm |
| Weight | Approx. 1.8 kg (with battery and holster) |
| Power Supply | Rechargeable Li-ion battery (7.2 V, 4.4 Ah) or AC adapter |
| Battery Life | Approx. 4 hours typical |
| Safety Rating | CAT III 1000V, CAT IV 600V |
| Memory | Internal storage for waveforms and setups |
| Connectivity | USB 2.0 host and device, optional Wi-Fi |
| Accessories Included | Two probes, power adapter, battery, carrying holster, manual |
| Maintenance | Clean with a damp cloth; no solvents. Calibration recommended annually. |
| Repairability | Battery and fuses user-replaceable; other repairs by authorized service |
Frequently Asked Questions - ScopeMeter 190-202 FLUKE
How do I update the firmware on my Fluke ScopeMeter 190-202?
Connect the meter to a PC via USB and use the FlukeView software to check for updates. Follow the on-screen instructions to install.
Can I replace the battery myself?
Yes, the battery is user-replaceable. Turn off the meter, remove the holster, open the battery compartment, and replace with a Fluke approved Li-ion battery.
What is the maximum input voltage for the multimeter function?
The multimeter can measure up to 1000 V AC/DC (CAT III) and 600 V (CAT IV). Always observe safety categories.
How do I calibrate the oscilloscope?
Calibration should be performed by a certified Fluke service center annually. The device has a built-in self-calibration routine accessible via the Utility menu.
Why is my measurement unstable?
Check that the probe is properly compensated and in good condition. Ensure the input coupling (AC/DC) is appropriate. Ground the probe correctly.
Can I use the ScopeMeter on a three-phase system?
Yes, the two channels can measure two phases simultaneously. Use isolated inputs and ensure the voltage does not exceed the rated CAT levels.
How to save a waveform to internal memory?
Press the Save key, select Waveform, and choose a memory location. You can recall saved waveforms via the Recall menu.
What type of probes are included?
The device comes with two 10:1 passive probes (Fluke VPS410 or equivalent) with a bandwidth of 200 MHz.
How do I clean the ScopeMeter?
Use a soft cloth lightly dampened with water or mild detergent. Do not use solvents or abrasive cleaners. Ensure the device is dry before use.
Where can I download the full user manual?
The manual is available for free download on the Fluke website under the Support/Downloads section. Enter the model number 190-202.
User questions about ScopeMeter 190-202 FLUKE
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Multimeter in PDF format for free! Find your manual ScopeMeter 190-202 - FLUKE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ScopeMeter 190-202 by FLUKE.