| Product Type | Digital Multimeter with True RMS |
| Brand | FLIR |
| Model | CM83 |
| Display | Digital LCD with backlight |
| AC Voltage Range | 0.1 mV to 1000 V |
| DC Voltage Range | 0.1 mV to 1000 V |
| AC Current Range | 0.1 µA to 10 A |
| DC Current Range | 0.1 µA to 10 A |
| Resistance Range | 0.1 Ω to 40 MΩ |
| Capacitance Range | 1 nF to 4000 µF |
| Frequency Range | 10 Hz to 1 MHz |
| Temperature Measurement | -20°C to 1000°C (with thermocouple) |
| Safety Rating | CAT III 1000V, CAT IV 600V |
| Power Supply | 4 x AAA batteries (1.5V) |
| Dimensions (approx.) | 180 x 80 x 45 mm |
| Weight (approx.) | 380 g |
| Accessories Included | Test leads, thermocouple, batteries, user manual |
| Special Functions | Auto-ranging, data hold, backlight, auto-off |
| Cleaning | Wipe with a damp cloth; do not use solvents |
| Calibration | Recommended annually for accuracy |
| Spare Parts | Test leads, fuses (replaceable by qualified personnel) |
| Repairability | Authorized service center for calibration and repair |
| General Compliance | EN 61010-1, CE, RoHS |
Frequently Asked Questions - CM83 FLIR
How do I measure AC voltage with the FLIR CM83?
Rotate the dial to V~ (AC voltage). Insert the black lead into the COM jack and the red lead into the V/Ω jack. Connect probes to the circuit and read the display.
Can the FLIR CM83 measure temperature?
Yes, with the included thermocouple. Set the dial to the temperature mode (usually °C/°F) and insert the thermocouple into the dedicated input jacks.
What type of batteries does the CM83 use?
The FLIR CM83 uses 4 AAA batteries (1.5V each). Replace them when the battery indicator appears on the display.
Is the FLIR CM83 safety rated?
Yes, it is rated CAT III 1000V and CAT IV 600V, suitable for high-energy electrical measurements.
How do I test continuity with the CM83?
Set the dial to the continuity mode (diode symbol with sound waves). Connect probes; a beep indicates continuity below about 50Ω.
What is the true RMS capability in the CM83?
The CM83 measures True RMS for both AC voltage and current, providing accurate readings on non-sinusoidal waveforms.
How often should the FLIR CM83 be calibrated?
For best accuracy, calibrate the meter annually. Refer to the manual for calibration procedures or contact FLIR support.
Can I measure frequency with the CM83?
Yes, set the dial to Hz mode. Connect probes to the signal source. The meter will display the frequency.
What does the data hold function do?
Press the HOLD button to freeze the current reading on the display. Press again to release.
How do I clean the FLIR CM83?
Wipe the exterior with a damp cloth and mild detergent if needed. Do not use solvents or immerse in water.