Product TypeDigital Multimeter with True RMS
BrandFLIR
ModelCM83
DisplayDigital LCD with backlight
AC Voltage Range0.1 mV to 1000 V
DC Voltage Range0.1 mV to 1000 V
AC Current Range0.1 µA to 10 A
DC Current Range0.1 µA to 10 A
Resistance Range0.1 Ω to 40 MΩ
Capacitance Range1 nF to 4000 µF
Frequency Range10 Hz to 1 MHz
Temperature Measurement-20°C to 1000°C (with thermocouple)
Safety RatingCAT III 1000V, CAT IV 600V
Power Supply4 x AAA batteries (1.5V)
Dimensions (approx.)180 x 80 x 45 mm
Weight (approx.)380 g
Accessories IncludedTest leads, thermocouple, batteries, user manual
Special FunctionsAuto-ranging, data hold, backlight, auto-off
CleaningWipe with a damp cloth; do not use solvents
CalibrationRecommended annually for accuracy
Spare PartsTest leads, fuses (replaceable by qualified personnel)
RepairabilityAuthorized service center for calibration and repair
General ComplianceEN 61010-1, CE, RoHS

Frequently Asked Questions - CM83 FLIR

How do I measure AC voltage with the FLIR CM83?
Rotate the dial to V~ (AC voltage). Insert the black lead into the COM jack and the red lead into the V/Ω jack. Connect probes to the circuit and read the display.
Can the FLIR CM83 measure temperature?
Yes, with the included thermocouple. Set the dial to the temperature mode (usually °C/°F) and insert the thermocouple into the dedicated input jacks.
What type of batteries does the CM83 use?
The FLIR CM83 uses 4 AAA batteries (1.5V each). Replace them when the battery indicator appears on the display.
Is the FLIR CM83 safety rated?
Yes, it is rated CAT III 1000V and CAT IV 600V, suitable for high-energy electrical measurements.
How do I test continuity with the CM83?
Set the dial to the continuity mode (diode symbol with sound waves). Connect probes; a beep indicates continuity below about 50Ω.
What is the true RMS capability in the CM83?
The CM83 measures True RMS for both AC voltage and current, providing accurate readings on non-sinusoidal waveforms.
How often should the FLIR CM83 be calibrated?
For best accuracy, calibrate the meter annually. Refer to the manual for calibration procedures or contact FLIR support.
Can I measure frequency with the CM83?
Yes, set the dial to Hz mode. Connect probes to the signal source. The meter will display the frequency.
What does the data hold function do?
Press the HOLD button to freeze the current reading on the display. Press again to release.
How do I clean the FLIR CM83?
Wipe the exterior with a damp cloth and mild detergent if needed. Do not use solvents or immerse in water.

User questions about CM83 FLIR

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Multimeter in PDF format for free! Find your manual CM83 - FLIR and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CM83 by FLIR.

USER MANUAL CM83 FLIR

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : FLIR

Model : CM83

Category : Multimeter