FlowAnalyser PF-300 PRO - Measuring equipment Rigel Medical - Free user manual and instructions
Find the device manual for free FlowAnalyser PF-300 PRO Rigel Medical in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Flow Analyzer / Ventilator Tester |
| Brand | Rigel Medical |
| Model | FlowAnalyser PF-300 PRO |
| Category | Measuring Equipment |
| Display | 5.7-inch Color Touchscreen |
| Power Supply | 100-240 VAC, 50/60 Hz |
| Battery | Rechargeable Li-Ion, 4 hours continuous operation |
| Dimensions (HxWxD) | 300 x 200 x 100 mm |
| Weight | 2.0 kg |
| Connectivity | USB, RS-232, Bluetooth (optional) |
| Measurement Parameters | Flow, Pressure, Volume, Oxygen Concentration |
| Flow Range | 0 to 300 L/min (BTPS) |
| Pressure Range | -20 to +100 cmH₂O |
| Accuracy | ±2% of reading or ±0.1 L/min (flow), ±1% of reading (pressure) |
| Operating Temperature | +10°C to +40°C |
| Storage Temperature | -20°C to +60°C |
| Relative Humidity | 10% to 90% non-condensing |
| Standards | ISO 10651, IEC 60601 |
| Accessories Included | Test lung, hoses, pressure tubing, power cord, USB cable, carrying case |
| Languages | English, Spanish, French, German |
| Warranty | 2 years |
Frequently Asked Questions - FlowAnalyser PF-300 PRO Rigel Medical
How do I perform a baseline calibration?
Connect the FlowAnalyser PF-300 PRO to a reference flow source and navigate to the calibration menu. Follow the on-screen instructions to zero and span the sensors.
What types of ventilators can be tested?
The device is compatible with most adult, pediatric, and neonatal ventilators. It supports volume-controlled, pressure-controlled, and spontaneous breathing modes.
How often should the device be recalibrated?
Rigel Medical recommends recalibration every 12 months or after 200 hours of use, whichever comes first. Refer to the manual for detailed procedures.
Can I use the FlowAnalyser with a PC?
Yes, the USB and RS-232 ports allow connection to a PC. The included software enables data logging, graph generation, and report printing.
What does the battery indicator mean?
The battery icon on the touchscreen shows remaining charge. When it reaches 10%, a warning appears. Charge the device using the provided power adapter.
How do I clean the device?
Disconnect all hoses. Wipe the exterior with a soft, damp cloth and mild detergent. Do not immerse in liquid. Clean the test lung separately.
What is the maximum flow rate measurable?
The PF-300 PRO can measure flows up to 300 L/min (BTPS). For higher flows, use an optional external flow sensor.
Why does the pressure reading show negative values?
Negative pressures occur during expiratory phases or when measuring PEEP. The device displays both positive and negative pressures within the range of -20 to +100 cmH₂O.
Can I update the firmware?
Yes, firmware updates are available on the Rigel Medical website. Connect the device via USB, run the updater, and follow the screen prompts. Do not disconnect during update.
What does error code E02 mean?
Error E02 indicates a sensor communication failure. Power cycle the device and check cable connections. If persists, contact Rigel Medical technical support.
User questions about FlowAnalyser PF-300 PRO Rigel Medical
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Measuring equipment in PDF format for free! Find your manual FlowAnalyser PF-300 PRO - Rigel Medical and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FlowAnalyser PF-300 PRO by Rigel Medical.