Product Type Passive Infrared (PIR) Detector
Model FD322
Brand Optex
Detection Method Passive Infrared (PIR)
Maximum Detection Range 12 m (39 ft) at 25°C
Detection Angle 90° (standard lens)
Mounting Height 1.8 m to 2.5 m recommended
Power Supply 9 to 16 V DC
Current Consumption 15 mA typical at 12 V DC
Alarm Output NC (Normally Closed) relay, 28 V DC, 0.2 A max
Tamper Output NC (Normally Closed), 28 V DC, 0.1 A max
Adjustable Pulse Count 1, 2, or 3 pulses selectable by jumper
LED Indicator Red LED for alarm and walk test
Dimensions (H x W x D) 108 x 50 x 30 mm
Weight 80 g
Operating Temperature -20°C to +50°C
Humidity Up to 95% non-condensing
Pet Immunity Up to 20 kg (dog) with specific lens (optional)
Maintenance Clean lens with soft dry cloth; avoid solvents
Safety Complies with EN 50131-2-2 Grade 2
Spare Parts Lens masks, brackets, and optional lenses available
Repairability Field replaceable lens and terminal block

Frequently Asked Questions - FD322 OPTEX

What is the detection range of the Optex FD322?
The FD322 has a maximum detection range of 12 meters (39 feet) at 25°C, with a 90° detection angle using the standard lens.
How do I wire the FD322 detector?
Connect power (9-16 V DC) to the + and - terminals. The alarm output is a Normally Closed (NC) relay (COM and NC terminals). Tamper output also NC. Refer to the terminal layout in the manual.
Can the FD322 detect pets?
With an optional pet immunity lens, the FD322 can ignore animals up to 20 kg. Without it, it may trigger on small animals.
How do I adjust the sensitivity?
Sensitivity is adjusted via a potentiometer on the PCB. Additionally, the pulse count can be set to 1, 2, or 3 via a jumper to reduce false alarms.
What is the mounting height for the FD322?
Recommended mounting height is 1.8 to 2.5 meters above the ground for optimal coverage.
Does the FD322 have a tamper switch?
Yes, it has a tamper switch that activates when the cover is removed, which can be wired to an alarm panel.
How do I perform a walk test?
Set the jumper to 'walk test' mode (often labeled 'TEST'). The red LED will illuminate for 2-3 seconds when motion is detected.
What power supply is required?
The FD322 operates on 9 to 16 V DC, typically 12 V DC, with a current draw of about 15 mA.
How do I clean the FD322?
Use a soft, dry cloth to gently clean the lens and case. Do not use water, solvents, or abrasive cleaners.
What spare parts are available?
Optional lenses (e.g., long range, curtain, pet immunity), mounting brackets, and terminal blocks are available from Optex.

User questions about FD322 OPTEX

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Detector in PDF format for free! Find your manual FD322 - OPTEX and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FD322 by OPTEX.

USER MANUAL FD322 OPTEX

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : OPTEX

Model : FD322

Category : Detector