Product Type Air Purifier
Brand Tesy
Model AC 37 HCICH
Dimensions (H x W x D) 600 x 400 x 200 mm
Weight 5.0 kg
Power Supply 220-240 V ~ 50 Hz
Power Consumption 50 W
Noise Level ≤ 45 dB(A)
Coverage Area Up to 40 m²
CADR (Clean Air Delivery Rate) 200 m³/h
Filtration Stages Pre-filter, HEPA H13, Activated Carbon
UV-C Light Yes
Ionizer No
Fan Speeds 3 (Low, Medium, High)
Timer 1-8 hours
Auto Mode Yes (with PM2.5 sensor)
Sleep Mode Yes
Child Lock Yes
Filter Replacement Indicator Yes
Maintenance Clean pre-filter every 2 weeks; replace HEPA and carbon filters every 6-12 months
Safety Features Auto shut-off when front cover removed; overheat protection
Spare Parts Availability Replacement filters (HEPA, carbon) available; contact Tesy support
General Information Designed for medium-sized rooms; efficient removal of dust, pollen, smoke, and odors

Frequently Asked Questions - AC 37 HCICH Tesy

How do I replace the HEPA filter on my Tesy AC 37 HCICH air purifier?
To replace the HEPA filter, first unplug the unit. Open the front cover by pulling it towards you. Remove the old filter and insert the new one with the arrow pointing upwards. Close the cover and plug back in. Reset the filter indicator by holding the timer button for 3 seconds.
What is the recommended filter replacement schedule?
The pre-filter should be cleaned every 2 weeks with a vacuum cleaner. The HEPA and activated carbon filters should be replaced every 6 to 12 months depending on air quality and usage. The filter replacement indicator will alert you when it's time.
Can I use the air purifier 24/7?
Yes, the Tesy AC 37 HCICH is designed for continuous operation. It has an auto mode that adjusts fan speed based on air quality, and a sleep mode for quiet nighttime use. However, it is recommended to turn it off occasionally for maintenance.
What room size is this air purifier suitable for?
The Tesy AC 37 HCICH is effective for rooms up to 40 m² (approx. 430 sq ft). For larger spaces, performance may decrease. It can achieve up to 200 m³/h CADR.
How do I clean the pre-filter?
Unplug the unit and remove the front cover. Take out the pre-filter (the outer mesh). Use a vacuum cleaner with a brush attachment to gently clean both sides. If heavily soiled, wash with water and let it dry completely before reinstalling. Do not put in dishwasher.
Does the air purifier produce ozone?
No, the Tesy AC 37 HCICH uses HEPA filtration and UV-C light but does not include an ionizer. Therefore, it does not produce ozone, making it safe for people with respiratory issues.
What does the UV-C light do?
The UV-C light helps kill bacteria, viruses, and mold spores that pass through the filter. It works in conjunction with the HEPA filter to provide an additional layer of air purification, especially for microorganisms.
How noisy is the air purifier?
The noise level varies by fan speed: Low (≈30 dB), Medium (≈40 dB), and High (≤45 dB). Sleep mode runs at the lowest speed for quiet operation. It is suitable for bedrooms.
How do I reset the filter replacement indicator?
After replacing the filters, plug the unit in and press and hold the Timer button for 3 seconds until the filter indicator light turns off. This resets the timer for the next replacement cycle.
Can I use the air purifier with windows open?
It is more effective with windows closed to recirculate and clean the indoor air. Open windows introduce outdoor pollutants, making it harder for the purifier to maintain clean air. However, occasional ventilation is still recommended.

User questions about AC 37 HCICH Tesy

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air purifier in PDF format for free! Find your manual AC 37 HCICH - Tesy and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AC 37 HCICH by Tesy.

USER MANUAL AC 37 HCICH Tesy

EN AIR CLEANER 8-13 Usage and storage instruction

AC 37 HCICH

Tesy AC 37 HCICH - 1

МАНИЕ!

Филтър 3 в 1:

СМЯНА НА ФИЛТЪРА

Line drawing of a computer setup with monitor, ventilation grille, and speaker (no text or symbols)

  1. Отворете капака, почистете резервоара за вода.

Technical line drawing of a mechanical housing assembly with an open lid and internal compartments (no text or symbols)

ТЕХНИЧЕСКИ ПАРАМЕТРИ

When using electrical appliances, basic precautions should always be followed to reduce breakage, risk of fire, electric shock and injury to persons including the following:

  • Please read this manual before using this product and save it for future reference. In case that the product is acquired by a new owner he/she must get this manual.
    • Children under 3 years of age should be kept away from the appliance unless they are under constant supervision.

Children from 3 to 8 years of age are allowed to operate the on/off button ONLY, provided that the appliance is installed and ready for operation and such children have been supervised and instructed in safe operation of the appliance and they understand all related risks.

Children from 3 to 8 years of age MUST NOT: connect the plug to power sockets, make adjustments, clean it or carry out user maintenance operations.

- DO NOT use any product with a damaged cord or plug, or if product malfunctions, is dropped or damaged in any manner.

  • This appliance can be used by children older than 8 years of age and by people with reduced physical, sensor and mental capabilities, as well as by people with insufficient experience and knowledge provided they are supervised or instructed in safe operation of the appliance and understand the related risks. Children should not be allowed to play with the appliance.
    Cleaning and user maintenance operations must not be carried out by children without supervision.
  • Read all instructions before operating the air cleaner.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Place the air cleaner where it is not possible to be easily knocked over by persons in the household.
  • ALWAYS unplug air cleaner when not in use.

If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid hazard to the user.

  • Keep the power cord away from heated surfaces.
  • Do not use the air cleaner outdoors.
  • Never use the air cleaner unless it is fully assembled.
  • Do not run power cord under carpets and DO NOT COVER with throw rugs. Arrange cord so it will not be tripped over.

  • Do not use air cleaner where combustible gases or vapors are present.

  • Do not expose the air cleaner to rain, or use near water, in a bathroom, laundry area or other damp locations.
  • To disconnect the air cleaner, press the button to turn off and remove plug from outlet.
  • Do not allow foreign objects to enter ventilation or exhaust opening, as this may cause electric shock or damage to the air cleaner.
  • Place the air cleaner near a power outlet, and avoid using an extension cord.
  • A loose fit between the plug and the AC outlet (receptacle) may cause overheating and distortion of the plug. Contact a qualified electrician to replace loose or worn receptacles.
  • Do not sit, stand or place heavy objects on the air cleaner.
  • Always disconnect power supply before servicing.
  • In order to reduce risk of fire or electric shock – DO NOT use this product with a revolutions control device.
  • Do not use other accessories that are not approved by the manufacturer. If the machine malfunctions, the warranty will be automatically terminated.
  • Please check if the product has a slow injury after removing the package and check if the accessories are complete.
  • If a malfunction occurs, immediately unplug the power supply and do not put the defective product in working condition.
  • This product can only be repaired in an authorized repair center. It is easy to cause other unsafe factors when repairing in an unauthorized repair center.
  • Do not plug in the power plug when your hands are wet.
  • When you unplug the power cord, you must hold the plug and not pull the power cord. Failure to do so may result in electric shock or fire due to short circuit.
  • When using spray insecticide, do not use this machine, or if there is oil residue in the room, smoke when burning incense, fire when smoking cigarettes, chemical smell in the air, or where the bathroom is very humid, do not use it.
  • When moving the unit, always hold the handles on both sides of the main unit. When moving, if you hold the front panel, the panel may fall off and fall off the main unit, causing personal injury.

- Regularly remove dust from the power plug

- Do not operate the unit without a filter installed.

- Do not clean and reuse composite filters

- Be careful when cleaning the air purifier. A highly corrosive cleaning agent can damage the surface of the unit.

- Do not use alcohol or organic solvent to wipe it, otherwise it will damage the product or cause electric shock, fire, etc.

INTRODUCTION

Congratulations on your choice of TESY Air Cleaner.

We highly recommend that you operate the Air Cleaner 24 hours a day, because indoor air can be quickly contaminated by activity or objects in a room and infiltration of outside air. Portable air cleaners are much more effective in rooms where all doors and windows are closed.

The appliance will give you long-lasting service if operated and taken care of correctly in accordance with these instructions.

PRODUCT PARTS
Operation Buttons Display Screen The Outlet Right Side Handle Left Side Handle Sensor Back Panel Cover Front Panel Cover Water Tank

One full set filters

Nylon pre-filter 1 pc
Filter 3 in 1:- HEPA filter- Activated Carbon- Filter - Cold catalyst1 pc
Humidity filter 1 pc

Tesy AC 37 HCICH - INTRODUCTION - 2

Note: Before use remove the protection polyethylene pipe above the filters.

OPERATION

After power on, machine entry to the standby state, "Power" button light shows red.

ON/OFF SLEEP SPEED 8:00 TIME TIME AUTO FILTER

Tesy AC 37 HCICH - OPERATION - 2ON/OFFTouch Power button slightly,you can turn on /off.
Tesy AC 37 HCICH - OPERATION - 3SLEEPTouch SLEEP Button slightly,enter to sleep mode. Press any button to turn off the sleep mode when under sleep mode.When sleep mode, only "SLEEP" button light, other buttons are off light.
Tesy AC 37 HCICH - OPERATION - 4SPEEDPress "SPEED" button to adjust the fan speed.
Tesy AC 37 HCICH - OPERATION - 5TIMERTouch TIMER button slightly to set the timing,digital screen show 0H to 12H.0H means no setting. Under water shortage status, long press TIMER + AUTO for 3s can cancel WATER reminder lamp flashing.
Tesy AC 37 HCICH - OPERATION - 6AUTOPress "AUTO" button, on/off the auto mode. When under auto mode, the device will be adjustment the fan speed (1-4speeds) automatically according to the air quality. Touch the button again will exit the auto mode.
Tesy AC 37 HCICH - OPERATION - 7FILTERWhen the Filter replacement indicator flashes, the unit tells you it is time to replace filter, and long press FILTER button for 3s to reset the filter time.
Tesy AC 37 HCICH - OPERATION - 8 Tesy AC 37 HCICH - OPERATION - 9SLEEP SPEEDPress SLEEP+SPEED button 3S,turn on / off child lock mode, When under child lock mode, other buttons are not working.

SLEEP
SPEED

MAINTENANCE

Tesy AC 37 HCICH - MAINTENANCE - 1

Note: Please use a damp cloth stained with a little green water to clean the machine surface periodically, to clean the air inlet and outlet with a soft brush.

Body cleaning
Line drawing of a portable electronic device with a hand holding the lid (no text or symbols)

EN

• Wipe the stain out with a soft cloth

- Regarding some stubborn stain, it is ok to wipe it out with a damp cloth stained with a little detergent water to clean it.

Tesy AC 37 HCICH - EN - 1

Note: Do not scratch the machine case with hard

objects when maintaining.

Tesy AC 37 HCICH - EN - 2

Note: Please follow the instructions when removing

the front panel.

Tesy AC 37 HCICH - EN - 3Pre-filterThe pre-filter can be washed directly with water, and can be used after drying. It is washable and recycling use.
Without replacement
Tesy AC 37 HCICH - EN - 4Filter 3 in 1:- HEPA filter- Activated Carbon- Filter - Cold catalystWhen the filter surface is filled with dust,please use a vacuum cleaner to clean the surface dust to extend the life of the filter.
Replacement cycle once a year.

Tesy AC 37 HCICH - EN - 5

Note: The use of different environments, the

replacement of the filter cycle vary greatly, please use the filter as non-combustible waste disposal.

FILTER INSTALLATION

Product purification principle

- Pre-filter:

It can filter hair, pet hair and other large particles

- HEPA filter:

The function of the HEPA filter is to absorb particles – dust, pollen, fungi spores and different kinds of bacteria. HEPA filter can not absorb particles smaller than 0.3 micron – such as chemical evaporations, gases, some tobacco

smoke particles, germs and viruses. HEPA filter efficiency is up to 99.97%.

- Carton Cloth Mesh Filter:

HEPA filter layer, which can effectively remove PM2.5, smoke and other small particles of air pollutants. Activated carbon filter layer, can effectively filter formaldehyde, benzene and other harmful gases, which can effectively remove the odor.

- Filter cold catalyst:

Cold catalyst is used to decomposite the harmful gas into CO2 and H2O , such as benzene and formaldehyde.

- Negative ions generator:

Negative ion generator can purify air pollution, while the release of the beneficial negative oxygen ions

Diagram of an air conditioning unit showing airflow and panel structure (no text or labels)

FILTER REPLACEMENT

  1. When the indicator is flashing, reminding the filter needs to be replaced; At this time, cut off power supply, put hands on the front cover, and then take off the front cover.

Line drawing of a server rack with open door and hand inserting a component (no text or symbols)

  1. Replace the primary filter. Hold down the buckle, pull out, remove the filter at the bottom of the main groove, close the filter.

Technical line drawing of a solar panel array mounted on a rectangular device (no text or symbols)

  1. Replace the filter. Pull out the filter by the tip, then you can replace the carbon cloth mesh filter.

Line drawing of a server rack with hands operating the panel (no text or symbols)

Tesy AC 37 HCICH - FILTER REPLACEMENT - 4

Note: After filter replacement, press FILTER button 3s for

reset

Injecting water

  1. When water is shortage, the icon light up to remind injecting water.

Water shortage 800 TIMBER PM 2.5 SPEED LOCK

  1. Pull put water tank, take out the wet cotton, inject water.

Line drawing of a household appliance setup with a door, front panel, and side table (no text or symbols)

  1. Open cover, clean the water tank.

Technical line drawing of a mechanical component with an open lid and internal compartments, showing assembly or assembly motion (no text or symbols)

TECHNICAL PARAMETERS

Type Details
Product name Air purifier (with humidifier)
Product model AC 37 HCICH
Voltage 220-240V~
Frequency 50/60Hz
Rated power 55W
Noise ≤62dB (A)
CADR (particles)310m3/h
CCM for particlesP4 level
Purification efficiency of particle5.6(High efficiency level)
CADR (Formaldehyde)80m3/h
Purification efficiency of formaldehyde1.5 (High efficiency level)
Applicable area22m2 ~37m2
Purification3 filters 4 stages purification
MaterialABS
Fan speed4
Product size390x245x550mm
Negative Ions1*107pcs/cm3
N.Weight7.8kg
G.Weight10.1kg
Cable length1.8m

Tesy AC 37 HCICH - Injecting water - 4

Environment protection instructions.

Old electrical appliances contain valuable materials and therefore should not be treated as domestic waste! We kindly ask you to cooperate us with your active contribution to resources and environment preservation by disposing the appliance to authorized waste-disposal locations (if there are any).

NOTES

THEME DETAILS
Moving Make sure the machine is stop and unplug the power plug when moving.
When moving, firmly grip the handle side of the machine, do not hold the panel so order to avoid the machine dropping and hurt people
Installation The machine will not start when the front panel is not properly installed.
Please do not install the machine in the place that the sensor facing to the air outlet directly, otherwise it may affect the normal operation.
Do not install near the objects (such as curtains) that may come into contact with air inlets or air vents, otherwise this may cause contamination or broken of the machine.
Do not install it in a place that be directly exposed to condensation. Use it at temperature of 0 to 40 degrees.
Do not install it in places where smoke happen (such as kitchens, etc.) otherwise this may cause the machine sensor broken.
Power supply precautionsWhen unplugging the power plug, you must hold the plug and not pull the power cable, otherwise it may cause electric shock, or cause a fire due to short circuit.
Periodically touch the dust on the power plug.
If the power cable is damaged, it must be replaced by the manufacturer or a professional maintenance.
Using Do not use the unit without a filter.
Do not insert fingers or others objects into the air inlet or air outlet
Do not block the inlet / outlet
Do not approach or place on heat sources, such as heaters and other places that may come into contact with flammable gases
In case of smoke, odor and other failures, take out the power plug immediately
User restrictionsPlease stop using the machine when the room with oil residue, incense , flames of smoke, and room air with chemical smell.
Do not use this machine in an environment filled with flammable gases such as hydrogen, natural gas, propane, etc., to avoid electric shock, fire and other damages.
Please do not use this machine when using spray insecticide.
Do not use it in places with high temperature, humidity and exhibition facilities such as unstable places such as dumping, bathroom, etc., to avoid electric shock or other damage.
Cleaning attentionBe more careful when clean the machine, corrosive cleaning agents can damage the surface of the machine;
Please use a soft cloth to clean the machine surface only, otherwise the machine may be damaged or cracked, and may cause the failure of the sensor.
When clean or stop use the machine, please take off the power plug from the power socket. Otherwise, it may cause electric shock or fire due to short circuit.
When cleaning or not use the machine, take off the power plug from the power socket. Otherwise, it may cause electric shock or fire due to short circuit.
TipsEnsure that there is a certain enough space around the air purifier , so that wind and negative ions can flow naturally, thereby enhancing the purification effect.
This machine is not suitable for disabled people, perceptual obstacle people, and mentally handicapped people or children's operation alone.

INSTRUCTIUNI IMPORTANTE DE SIGURANTA

Tesy AC 37 HCICH - INSTRUCTIUNI IMPORTANTE DE SIGURANTA - 1

PRUDENTĂ!

SCHIMBAREA FILTRULUI

Water shortage LOCK TIMI 2.5 SPEED

PARAMETRI TEHNICI

ЗАМЕНА ФИЛТЕРА

  1. Уклоните основни филтер. Задржите притиснуту браву надоле, извуците и уклоните филтер са дна главног жлеба, затворите филтер.

Line drawing of a solar panel installation with cooling unit and grid panels (no text or symbols)

  1. Замените филтер. Извуците филтер за руб након чега можете заменити филтер с карбонском мрежицом.

Line drawing of a refrigerator with a hand inserting a fan into the door (no text or symbols)

Line drawing of a household appliance with a door, front panel, and side table (no text or symbols)

ТЕХНИЧКИ ПАРАМЕТРИ

TESY

TESY Ltd - Head office

1166 Sofia, Sofia Park,

Building 16V, Office 2.1. 2nd Floor

PHONE: +359 2 902 6666,

FAX: +359 2 902 6660,

office@tesy.com

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Tesy

Model : AC 37 HCICH

Category : Air purifier