| Product Type | Miniature Circuit Breaker (MCB) |
| Brand | Hager |
| Model | VM110K |
| Number of Poles | 1 |
| Rated Current (In) | 10 A |
| Rated Voltage (Ue) | 230/400 V AC |
| Breaking Capacity | 6 kA (IEC 60898-1) |
| Tripping Curve | K (motor protection) |
| Frequency | 50/60 Hz |
| Dimensions (H x W x D) | 90 mm x 18 mm x 70 mm |
| Weight | 0.1 kg |
| Mounting Type | DIN rail (35 mm) |
| Protection Degree (IP) | IP20 (finger-safe terminals) |
| Operating Temperature | -5°C to +40°C |
| Storage Temperature | -25°C to +70°C |
| Terminal Capacity | 1-25 mm² (copper wire) |
| Standard Compliance | IEC 60898-1, EN 60898-1 |
| Main Function | Overload and short-circuit protection |
| Additional Protection | Isolation function (230/400V) |
| Maintenance | No regular maintenance required; keep clean and dry |
| Cleaning | Wipe with dry cloth; do not use solvents |
| Safety Features | Touch-proof terminals, indicator for trip status |
| Spare Parts / Repairability | Non-repairable; replace entire unit if faulty |
| Application | Residential and light commercial distribution boards |
Frequently Asked Questions - VM110K HAGER
What is the rated current of the Hager VM110K circuit breaker?
The Hager VM110K has a rated current of 10 A.
What tripping curve does the VM110K use?
It uses a K curve, designed for motor protection and high inrush currents.
Can the VM110K be used for lighting circuits?
While possible, the K curve is not ideal for lighting; a B or C curve MCB is recommended for general lighting.
What is the breaking capacity of this MCB?
The breaking capacity is 6 kA according to IEC 60898-1.
Is the VM110K compatible with DIN rail mounting?
Yes, it mounts on a standard 35 mm DIN rail.
How do I know if the circuit breaker has tripped?
It has a mechanical indicator showing the ON/OFF/tripped position.
What wire size can be connected to the terminals?
Terminals accept copper wires from 1 mm² to 25 mm².
Can the VM110K be used in outdoor installations?
Only if installed in an IP65 enclosure, as the device itself is rated IP20.
Does this breaker provide isolation function?
Yes, it is suitable for isolation at 230/400 V when switched off.
Where can I find the manual for the VM110K?
The user manual is available for free download on notice-facile.com in PDF format.
User questions about VM110K HAGER
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Circuit breaker in PDF format for free! Find your manual VM110K - HAGER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. VM110K by HAGER.