| Product Type | Wireless Access Point |
| Model | AP61 |
| Brand | Mist (Juniper) |
| Wireless Standard | 802.11ax (Wi-Fi 6) |
| Frequency Bands | Dual-band (2.4 GHz & 5 GHz) |
| Max Data Rate | Up to 1.2 Gbps (2.4 GHz) + 4.8 Gbps (5 GHz) |
| MIMO | 4x4 MU-MIMO |
| Ethernet Ports | 1x 2.5 Gigabit Ethernet (PoE In) |
| Power over Ethernet | 802.3af/at PoE |
| Dimensions (W x D x H) | 200 mm x 200 mm x 40 mm |
| Weight | 0.8 kg (1.76 lbs) |
| Management | Cloud-based via Mist AI |
| Mesh Support | Yes |
| Power Supply | PoE (injector not included) |
| Operating Temperature | 0°C to 40°C |
| Mounting | Ceiling / Wall mount (bracket included) |
| Security | WPA3, AES, 802.1X |
| Maintenance | Clean with soft dry cloth; avoid liquids |
| Spare Parts / Repairability | No user-serviceable parts; contact support |
| Compliance | FCC, CE, RoHS |
Frequently Asked Questions - AP61 Mist
User questions about AP61 Mist
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Access Point in PDF format for free! Find your manual AP61 - Mist and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AP61 by Mist.
USER MANUAL AP61 Mist
The Mist AP61 is an IP67 rated outdoor access point which delivers 4x4 MIMO with four spatial streams when operating in multi-user (MU) or single-user (SU) mode that supports the IEEE 802.11ac Wave 2 specification.
I/O ports and Kensington lock

| LED/Reset Reset to the factory default settings | |
| Eth0+PoE | 10/100/1000 BaseT RJ45 interface that supports 802.3at PoE PD |
| Eth1 10/100/1000 BaseT RJ45 interface | |
On the AP61E, there are 4 N-type antenna connectors (Ant1-Ant4)
Outdoor AP Articulating Mount installation
Mounting kit contents:
Articulation Pole x 1
T-form Bracket x 1
W-Bar x 1
M8x80 Screw Bolts x 2
Wood Screw x 4
Wood / Gyprock Plug x 4

Metal plate assembly with RT2 mount x 1
M8x90 Screw
Bolts x 1
Nut x 1
M6x16 Screw x 4
M6x10 Screw x 4

Washer x 8 Spring Washer x 8
Installation with the articulating mount bracket (included in box):
Step 1: Install the metal plate to the AP61

Step 2: Install the T-form bracket to the wall or pole:
Install T-form bracket to a wall
Install T-form bracket to a pole

Fix the mount base to the wall using wood / gyprock screws.

Mounting For Pole Larger than 1.5"(35mm) and Less Than 3" (80 mm)
Step 3: Install the AP61 to the T-form bracket.

Attach the articulation pole to the mount base articulation using M8x90 bolt, nut and washers.
In a wall mount installation, please use screws that have a 1/4in. (6.3mm) diameter head with a length at least 2 in. (50.8mm).
In a pole mount installation, please use the M8x80 screws to attach to the pole mount kit.
Outdoor AP Flush Mount installation
AP61 Flush Mount Bracket – Wall Mount

(a) Drill four holes in the wall and insert anchors

(b) Install the upper two screws, but do not fully tighten them.

(c) Install the flush mount bracket onto the AP61.

(d) Install the flush mount bracket with the AP61 onto the screws in the wall and slide it down.

(e) Install the remaining two screws and tighten all the screws.

(f) Installation complete.
AP61 Flush Mount Bracket – Pole Mount

(a) Assemble the hose clamps onto the flush mount bracket.

(b) Assemble the flush mount bracket with the hose clamps onto the AP61.

(c) Assemble the AP61 with the flush mount bracket onto the pole, and use a screwdriver to tighten the hose clamps.

*Use a screwdriver to tighten.

* Use a screwdriver to release the hose clamp.
Caution:
During the installation of the access point, we recommend that accessible metal parts of the product are connected to ground with 18 AWG wire.
Technical Specifications:
| Feature Description | |
| Power options 802.3at | PoE |
| Dimensions | AP61 - 12.2in x 12.2in x 4.2in (310mm x 310mm x 107mm)AP61E - 12.2in x 13.5in x 4.2in (310mm x 343mm x 107mm) |
| Weight | AP61 - 9.85 lbs (4.47 kg)AP61E - 10.1 lbs (4.59 kg) |
| Operating temperature | Internal antenna -20° to 65°CExternal antenna -20° to 65°C |
| Operating humidity | 10% to 90% maximum relative humidity, non-condensing |
| Operating altitude 3,048m (10,000 ft) | |
| I/O | 1 - 10/100/1000BASE-T auto-sensing RJ-45 with PoE1 - 10/100/1000BASE-T auto-sensing RJ-45 |
| RF | 2.4GHz - 4x4:4 spatial streams 802.11ac MU-MIMO & SU-MIMO5GHz - 4x4:4 spatial streams 802.11ac MU-MIMO & SU-MIMO2.4GHz / 5GHz scanning radio2.4GHz BLE with Dynamic Antenna Array |
| Maximum PHY rate | Total maximum PHY rate - 2533Mbps5GHz - 1733 Mbps2.4GHz - 800Mbps |
| Indicators Multi-color status LED | |
| Compliance standards | FCC Part 15.247, 15.407, 15.107, and 15.109FCC Part 15 Class BRSS-247ICES-003 (Canada)EN 301 489-1 V2.1.1EN 301 489-17 V3.1.1EN 300 328 V2.1.1EN 301 893 V2.1.1EN 50385: 2002EN 55032:2015 + AC:2016, Class BIP67 rated |
Recommended power supply specifications:
- UL certified with a voltage rating of 50-57Vdc and 600mA
- Rated for 65C
- Altitude spec of 3,048m
- Comply with LPS
Warranty Information
The AP61 family of Access Points comes with a limited lifetime warranty.
Ordering Information:
Access Points
| AP61-US Premium Outdoor Wi-Fi & BLE Array AP - Internal Antenna for the US Regulatory domain | |
| AP61E-US Premium Outdoor Wi-Fi & BLE Array AP - External Antenna for the US Regulatory domain | |
| AP61-WW Premium Outdoor Wi-Fi & BLE Array AP - Internal Antenna for the WW Regulatory domain | |
| AP61E-WW Premium Outdoor Wi-Fi & BLE Array AP - External Antenna for the WW Regulatory domain |
Accessories and spare parts
| SP-01 Ethernet Surge Protector | |
| APOUT-BR1 / APOUTBR-ART | Articulating mount for Outdoor AP |
| APOUTBR-FM | Flush mount for Outdoor AP |
The AP61 product includes an articulating mount bracket kit.
The flush mount kit can be ordered separately.
Regulatory Compliance Information:
If you need further assistance with purchasing the power source, please contact Mist Systems, Inc.
FCC Requirement for Operation in the United States of America:
FCC Guideline for Human Exposure
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 32cm between the radiator & your body.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
- Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
- This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
- For operation within 5.15 \~ 5.25GHz / 5.47 \~ 5.725GHz frequency range, it is restricted to indoor environment.
Industry Canada
This device complies with RSS-247 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 41cm between the radiator & your body.
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
(ii) The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall be such that the equipment still complies with the e.i.r.p. limit; (iii) The maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such that the equipment still complies with the e.i.r.p. limits specified for point-to-point and non-point-to-point operation as appropriate; and (iv) Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices.
Warning
This device complies with the Radio Equipment Directive, 2014/53/EU, issued by the Commission of the European Community.
Hereby, Mist Systems, Inc. declares that the radio equipment type (AP61) is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following:
https://www.mist.com/support/
The frequency and maximum EIRP Power in EU:
Bluetooth:
| Frequency range (MHz) Maximum EIRP in EU (dBm) | |
| 2400 - 2483.5 9.55 | |
WLAN:
| Frequency range (MHz) Maximum EIRP in EU (dBm) | |
| 2400 - 2483.5 19.98 | |
| 5500 - 5700 29.94 | |