IAN 91926 - Wristwatch AURIOL - Free user manual and instructions

Find the device manual for free IAN 91926 AURIOL in PDF.

AURIOL IAN 91926 - Wristwatch
📄 50 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice AURIOL IAN 91926 - page 32
View the manual : Deutsch DE English EN Español ES Italiano IT Português PT
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Watch
Brand Auriol
Model IAN 91926
Case Material Stainless steel
Glass Type Mineral crystal
Strap Material Leather or silicone (depending on variant)
Case Diameter Approx. 40 mm
Case Thickness Approx. 10 mm
Weight Approx. 50 g
Power Source Battery (typically CR2025 or SR626SW)
Battery Life Approximately 2 years
Display Type Analog with date window
Water Resistance 3 ATM (splash resistant, not suitable for swimming)
Functions Time, date, alarm, chronograph (stopwatch)
Movement Type Quartz
Clasp Type Buckle or deployment clasp
Care Instructions Clean with soft dry cloth; avoid contact with chemicals and extreme temperatures
Spare Parts Availability Batteries and straps available from retailer or service center
Repair Service Battery replacement and strap adjustment by a professional
Certifications CE, RoHS

Frequently Asked Questions - IAN 91926 AURIOL

How do I set the time on my Auriol IAN 91926 watch?
Pull the crown out to the second position (fully extended). Turn the crown clockwise or counterclockwise to set the correct time. Push the crown back in to secure.
How do I set the date on the watch?
Pull the crown out to the first position (halfway). Turn the crown clockwise to adjust the date. Note: avoid setting the date between 9 PM and 3 AM to prevent damage.
Is the Auriol IAN 91926 water resistant?
Yes, it has a water resistance rating of 3 ATM, meaning it can withstand splashes and brief immersion in water, but it is not suitable for swimming or diving.
What type of battery does the watch use?
The watch typically uses a CR2025 or SR626SW battery. Refer to the manual for the exact type. Battery life is approximately 2 years.
How do I replace the battery?
Remove the back cover using a small screwdriver or coin. Take out the old battery and insert the new one with the correct polarity (positive side up). Reattach the back cover securely. If unsure, consult a professional.
How do I adjust the watch strap?
For a leather strap, use a small pin to push out the spring bar and remove links. For a metal bracelet, use a pin removal tool to push out the pins. For silicone straps, simply adjust the buckle. Refer to the manual for details.
How do I use the chronograph (stopwatch)?
Press the top pusher (usually at 2 o'clock) to start the stopwatch. Press the same pusher again to stop. Press the bottom pusher (at 4 o'clock) to reset the chronograph hands to zero.
How do I set the alarm?
Pull the crown to the first position. Press the alarm pusher (if available) to enter alarm setting mode. Turn the crown to set the alarm time. Press the alarm pusher again to confirm. Ensure the alarm is activated by pulling out the crown or pressing a button (refer to manual).
What should I do if the watch stops working?
First, check if the battery needs replacement. If the watch still doesn't work, it may require professional servicing. Avoid opening the case yourself unless you are experienced.
How do I clean my Auriol watch?
Wipe the case and strap with a soft, lint-free cloth slightly dampened with water. Do not use solvents, soaps, or abrasive cleaners. For leather straps, avoid excessive moisture.

User questions about IAN 91926 AURIOL

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Wristwatch in PDF format for free! Find your manual IAN 91926 - AURIOL and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IAN 91926 by AURIOL.

USER MANUAL IAN 91926 AURIOL

Usage and safety instructions

IAN 91926

AURIOL IAN 91926 - 1

GB MT Usage and safety instructions....-29 -

3 BARAURIOL IAN 91926 - 2
5 BAR
10 BAR
20 BAR
3 BAR×××
5 BAR××
10 BAR×
20 BAR
3 BAR×××
5 BAR××
10 BAR×
20 BAR

Usage and safety instructions

Table of contents

Table of contents....- 29 -

Introduction - 30 -

Intended use....-30 -

Scope of delivery....- 30 -

Important safety information....- 30 -

Features - 31 -

Setting the normal time....- 31 -

Setting the date....- 31 -

Stopwatch feature - 32 -

Lap time measurement - 32 -

Adjusting the stopwatch hands - 32 -

Water resistance - 32 -

Band shortening instruction for metal straps - 33 -

Replacement of battery - 33 -

Cleaning instructions - 34 -

Disposal of the watch - 34 -

Disposal of the batteries - 34 -

digi-tech gmbh warranty - 34 -

Warranty conditions - 34 -

Warranty period and defects liability - 35 -

Scope of the warranty - 35 -

Warranty claim procedure - 36

Service - 37 -

Supplier - 37 -

AURIOL IAN 91926 - Table of contents - 1

CHRONOGRAPH WATCH

Introduction

Congratulations on the purchase of your new wristwatch. You have chosen a high quality product. The instruction manual is part of the product - it contains important information about safety, use and disposal. Read the manual with all usage and safety notes before using the watch. Only use the watch in the intended way and for the intended applications.

If the watch is given to someone else, include all documentation with the watch.

Intended use

This watch is intended for time display and the described additional features. Any other use or modification of the electronic appliance does not comply with the intended uses. The manufacturer is not liable for damages caused by improper use or misuse. The device is not intended for commercial use.

Scope of delivery

Please note: Check the scope of delivery after purchase. Please ensure that all parts are included and undamaged.

  • Wristwatch
  • Instruction manual • Band changing tool with metal band

Important safety information

- Batteries

Insert the batteries/ rechargeable batteries in the correct polarity. Don't try to recharge non-rechargeable batteries and under no circumstances throw them into fire. Danger of explosion.

Do not use unequal batteries (old and new, Alkaline and carbon, etc.) simultaneously. If you will not use the device for a long time, remove the batteries and store the device in a dry and dust-free place. Improper use of batteries may cause an explosion or leakage. If the batteries have leaked, use gloves and clean the wristwatch thoroughly with a dry cloth.

AURIOL IAN 91926 - - Batteries - 1

- The wristwatch should not be in the hands of children

Never let children use electrical devices unsupervised. Children can't always recognize the possible dangers properly. Batteries/rechargeable batteries can be life threatening when swallowed. Store the batteries where they cannot be reached by small children. If a battery is swallowed, medical aid must be sought immediately.

Also keep the packaging foils away from children. Danger of suffocation.

Features

Stopwatch 1/10

Stopwatch minutes

Stopwatch seconds

A B Date

Setting the normal time

Before setting the time, ensure that all stopwatch hands are at the "0" position and do not push the buttons as this will change the position of the stopwatch hands. Pull the crown out to the 2nd stop when the second hand reaches the 12 o'clock position. Set the time by turning the crown clockwise. Press the crown back to the initial position.

Setting the date

Pull the crown out to the 1st stop - turn the crown clockwise to set the correct date. Press the crown back to the initial position. The date will change between 23:30 and 24:00. If the date changes between 11:30 and 12:00, adjust the time by 12 hours.

AURIOL IAN 91926 - Setting the date - 1

Do not set the date between 9:00 pm and 1:00 am as this can cause damage to the movement.

AURIOL IAN 91926 - Setting the date - 2

Stopwatch feature

The stopwatch can measure a duration of up to 60 minutes in 1/10 second intervals.

Start: Press button A - the 1/10 second hand will start to rotate. The 1/10 second hand will run during the first minute of the measured time period - after this the movement will continue counting internally to conserve battery power. The second and minute hands will continue to run. Press button A again to stop the stopwatch. The measured time can now be read.

Press button B to move the hands back to the "0" position.

Lap time measurement

Press button A to start the stopwatch - press button B to stop the stopwatch and read the lap time, the stopwatch will continue to count internally. Press button B again to show the running stopwatch time. This process can be repeated as often as desired. Press A to stop the stopwatch and read the stopped time.

Adjusting the stopwatch hands

If the small stopwatch hands are not exactly in the "0" position (12 o'clock position) they must be adjusted manually. Pull the crown out to the 2nd stop - repeatedly press button A (1/10 seconds) or button B (seconds) to move the hands back to the "0" position. The minute hands of the stopwatch can be adjusted by pressing and holding B for a longer duration. Press the crown back to the initial position.

Water resistance

Water resistant up to 10 bar. The bar value specifies the atmospheric overpressure which is applied during testing (DIN 8310).

3 BAR ✓ × × × 5 BAR ✓ ✓ × × 10 BAR ✓ ✓ ✓ × 20 BAR ✓ ✓ ✓ ✓

AURIOL IAN 91926 - Water resistance - 2

Band shortening instruction for metal straps

1. 2. 3.

1. At the buckle (see fig. 1.)

Unlock the safety cover (if applicable) and open the buckle. The strap is held in position by a spring bar. The spring bar can be compressed with a pointed tool to enable shortening of the strap. Move the strap to the desired position and allow the spring bar to lock into place.

2. At the strap (see fig. 2 + see fig. 3)

Shortening of the strap can also be achieved by removing segments. Open the buckle and remove the spring bar as described in part Fig. 1.

Place the wristwatch on a soft surface with the dial facing downward. Fig. 2: The segments that can be removed are marked with an arrow. Fig. 3: Place the band in the band changing tool in such a way that the pointed end of the tool points directly at the metal rod. Turn the screw in the direction of the arrow until the metal rod is pushed out a small distance. The rod can now be pulled out (use tweezers if necessary).

The strap can now be disassembled.

Remove as many segments as necessary in the described fashion and reassemble the strap by pushing the bolt inwards in the opposite direction of the arrow. Reassemble the buckle with the spring bar.

Replacement of battery

(SR920SW)

Battery replacements must be performed by an expert to avoid damaging the case or gaskets.

AURIOL IAN 91926 - Replacement of battery - 1

Cleaning instructions

Clean the wristwatch with a soft, dry and lint-free cloth. A glasses cleaning cloth is ideal.

Disposal of the watch

This wristwatch may not be disposed of with normal household waste. Dispose of the wristwatch at an approved disposal facility or at your local recycling centre. Please observe the current rules and regulations when disposing of the watch. Contact the disposal system if in doubt.

AURIOL IAN 91926 - Disposal of the watch - 1

Disposal of the batteries

AURIOL IAN 91926 - Disposal of the batteries - 1

Please dispose of your batteries properly in containers especially set up at retailers. Batteries do not belong in household waste. Dispose of the batteries at an approved disposal facility or at your local recycling centre. Contact the disposal system if in doubt.

digi-tech gmbh warranty

This wristwatch includes a 3 year warranty starting on the day of purchase. In case of defects of this wristwatch you have, by law, certain rights regarding the vendor of the watch. These rights are not changed by the warranty which is described in the following paragraphs.

Warranty conditions

The warranty duration starts on the date of purchase. Please keep the original receipt in a safe place. The receipt is needed as proof of purchase. If a defect occurs in the wristwatch within 3 years, the wristwatch will be repaired or replaced (according to our choice) free of charge. This warranty requires that, within the 3-year warranty period, the wristwatch and the receipt can be made available to us along with a short written description of the defect and when it occurred. If the defect is covered by the warranty, you will receive the repaired wristwatch or a new watch. Repair or replacement does not cause the warranty period to restart.

AURIOL IAN 91926 - Warranty conditions - 1

Warranty period and defects liability

The warranty period is not increased by the defect liability. This also applies to repaired or replaced parts. If defects are noticed at the time of purchase, they must be reported immediately upon unpacking the item. Paid repair may be available after the end of the warranty period.

Scope of the warranty

The wristwatch was manufactured according to strict quality guidelines and was carefully inspected before delivery. The warranty does not include parts that experience normal wear and tear and can thus be seen as wear parts or fragile parts that are damaged. Examples include switches, batteries, or parts made of glass.

This warranty becomes void if the wristwatch is damaged, is not used in the recommended way, or is improperly repaired. For proper use of the wristwatch, all instructions in this manual must be adhered to exactly. Use of the wristwatch in a way that is discouraged in the manual must be avoided.

The wristwatch is not intended for commercial use. Abusive or improper use, excessive force, and changes that are made by non-authorized repair centers will void the warranty.

Warranty claim procedure

To ensure that your call is processed in a fast and efficient manner, please note the following directions:

  • Have your receipt (as proof of purchase) and the article number (91926) handy.
  • The article number can be found on the type label, an engraving, the front page of the manual (bottom left), or a sticker on the back side or bottom side of the case.
  • In case defects occur, please first contact the service center (see below) by phone or email.

AURIOL IAN 91926 - Warranty claim procedure - 1

Visit www.lidl-service.com to download this and many other manuals, product videos, and software.

AURIOL IAN 91926 - Warranty claim procedure - 2

Service

Please note that the following address is not a service address.

Please first contact the service address (see above).

Name: digi-tech gmbh

Street: Valterweg 27A

Town: Eppstein 65817

Country: Germany

AURIOL IAN 91926 - Service - 1

3 BAR×××
5 BAR××
10 BAR×
20 BAR
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : AURIOL

Model : IAN 91926

Category : Wristwatch