Download the instructions for your Fashion in PDF format for free! Find your manual ALYX - HOOVER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ALYX by HOOVER.

USER MANUAL ALYX HOOVER

IMPORTANT SAFETY REMIN DERS

User's manual-This cleaner should only be used for its intended purpose as described in these instructions. Ensure that these are fully understood before operating this appliance.

Only use attachments recommended or supplied by Hoover.

When using cleaning tools ensure that the cleaner is kept in the upright (parked) position. This will avoid possible damage to the carpet or floor covering. When cleaning stairs DO NOT position the cleaner above you.

STATIC ELECTRICITY. Some carpets can cause a small build up of static electricity. Any static discharge is not hazardous to health.

DO NOT use your cleaner out of doors or on any wet surface or for wet pick up.

Keep hands, feet, loose clothing and hair away from rotating brushes.

DO NOT pick up hard or sharp objects, matches, hot ashes, cigarette ends or other similar items.

DO NOT pick up flammable liquids such as cleaning fluids, petrol etc. or their vapours.

Aerosol sprays may be flammable. DO NOT spray near cleaner.

SUPPLY CORD. DO NOT run over the supply cord when using your cleaner or remove the plug by pulling on the supply cord.

FAULTS. DO NOT continue to use your cleaner if it appears to be faulty. If the supply cord is damaged stop using the cleaner IMMEDIATELY. The supply cord must be replaced by an authorised Hoover service engineer to avoid a safety hazard.

AFTER USE. Switch the cleaner off and remove the plug from the electricity supply. Always switch off and remove the plug before cleaning the appliance or attempting any maintenance task.

HOOVER SERVICE. To ensure the continued safe and efficient operation of this appliance we recommend that any servicing or repairs are only carried out by an authorised Hoover service engineer.

HOOVER SERVICE HOOVER SPARES

08705 400 600
01204 556 111

Use only HOOVER spares

Congratulations on the purchase of your new Hoover ÁLYX

This highly advanced machine - with new technology unique to Hoover - makes cleaning easier and more efficient.

You'll find it kinder to your carpets - and to you!

Please take the time to read this manual carefully.

You'll be ready to make the most of the special features only the new Hoover ÁLYX can offer!

WARNING! ELECTRICITY CAN BE EXTREMELY DANGEROUS

This appliance is double insulated and must not be earthed.

The plug is fitted with a 13 amp fuse.

IMPORTANT: The wires in the mains lead are coloured in accordance with the following code:

Blue - NEUTRAL Brown - LIVE

HOOVER®

ALYX

Effortless

cleaning

with your

new Hoover Alyx

When first unpacking your cleaner please check all items are included.

In the carton you should find the following items:

Cleaner body,

Handle with tool post,

Handle securing nut and bolt,

Dusting brush,

Crevice tool.

If any parts are missing,

do not take the product

back to the retailer, please

call the hoover Advice

Helpline (Open 7 days a week)

on 08705 400 600.

HOOVER ALYX - new Hoover Alyx - 1

HOOVER ALYX - new Hoover Alyx - 2

PREPARING TO USE YOUR CLEANER

Insert handle into body of cleaner.
Align holes and push bolt through. Remove the bin then fit the nut. Securely fasten the bolt.

HOOVER ALYX - PREPARING TO USE YOUR CLEANER - 1
1

HOOVER ALYX - PREPARING TO USE YOUR CLEANER - 2
2

3 Locate the dusting brush and crevice tool on the tool holder.
4 Position hose over handle hose support.

HOOVER ALYX - PREPARING TO USE YOUR CLEANER - 3
3

HOOVER ALYX - PREPARING TO USE YOUR CLEANER - 4
4

Position hose in lower hose clip.
Push hose end into foot hose socket.

HOOVER ALYX - PREPARING TO USE YOUR CLEANER - 5
5

HOOVER ALYX - PREPARING TO USE YOUR CLEANER - 6
6

7 Rotate cord storage hook to release power cord.
8 Secure power cord in retainer.

HOOVER ALYX - PREPARING TO USE YOUR CLEANER - 7
7

HOOVER ALYX - PREPARING TO USE YOUR CLEANER - 8
8

POWER SWITCH SETTING

Switching on and off

HOOVER ALYX - Switching on and off - 1
Push bottom of the switch to switch on.
Push top of switch to switch off.

HANDLE RELEASE

HOOVER ALYX - HANDLE RELEASE - 1
Unlock the handle by placing one foot on the hood and leaning the handle backward. For cleaning under low furniture simply lower handle to floor.

CLEANING TOOLS

HOOVER ALYX - CLEANING TOOLS - 1

IMPORTANT: When using cleaning tools, the cleaner must be kept in the upright (parked) position, particularly when cleaning stairs.

Detach cleaning hose.

HOOVER ALYX - CLEANING TOOLS - 2

HOOVER ALYX - CLEANING TOOLS - 3

Fitting crevice tool.

HOOVER ALYX - CLEANING TOOLS - 4

Fitting dusting brush.

HOOVER ALYX - CLEANING TOOLS - 5

HOOVER ALYX - CLEANING TOOLS - 6

All accessories can fit on the end of the flexible tube.

CLEANING THE STAIRS

It is dangerous for the cleaner to be above you at the top of the stairs.

ALWAYS work with the cleaner below you. Ensure it is positioned up against the bottom step.

HOOVER ALYX - CLEANING THE STAIRS - 1

REMOVAL AND EMPTYING OF THE DUST CONTAINER

HOOVER ALYX - REMOVAL AND EMPTYING OF THE DUST CONTAINER - 1

Lift the container release catch.

HOOVER ALYX - REMOVAL AND EMPTYING OF THE DUST CONTAINER - 2

Tilt the container forwards and remove.

HOOVER ALYX - REMOVAL AND EMPTYING OF THE DUST CONTAINER - 3

Hold the container away from you.

HOOVER ALYX - REMOVAL AND EMPTYING OF THE DUST CONTAINER - 4

Thanks to its easy opening system, the dust container opens and empties with no dust contact.

MAINTAINING THE DUST CONTAINER AND FILTERS

(PERIODIC MAINTAINENCE IS REQUIRED TO MAINTAIN OPTIMUM PERFORMANCE)

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 1

Remove the dust container as described on the previous page.

Twist the top part of the container whilst holding the lower part.

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 2

Remove the container top to expose the pre-motor filter.

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 3

Carefully remove the pre-motor filter.

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 4

The pre-motor filter should be washed after every five bin empties.

Wash under hand warm water.

Remove excess water and leave to dry for 24 hours.

When completely dry, refit the filter.

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 5

Remove the separator screen.

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 6

Inspect the separator screen and remove any dust and debris with a soft brush.

The seperator screen can be washed when necessary with hand warm water.

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 7

Refit the separator screen.

Please pay attention to alignment tab.

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 8

Refit the Pre-motor filter only when completely dry.

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 9

Open end of the pre-motor filter must face upwards.

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 10

Refit the container top.

Please pay attention to alignment tab.

HOOVER ALYX - MAINTAINING THE DUST CONTAINER AND FILTERS - 11

Twist the top part of the container whilst holding the lower part to lock together.

CHANGING THE BELT OR BRUSH

If your cleaner is not picking up efficiently, the belt or brush (or both) may need replacing, but first make sure you have:

  • Emptied the dust container
  • Cleaned the filters
  • Checked for blockages

HOOVER ALYX - CHANGING THE BELT OR BRUSH - 1

Remove hood

Turn the machine over.

Locate the six screws as shown opposite.

HOOVER ALYX - Remove hood - 1

Remove the screws completely.

HOOVER ALYX - Remove hood - 2

Turn the machine over.

HOOVER ALYX - Remove hood - 3

Remove the hood.
Inspect the belt and brushes.

To remove the brush, pull upwards and outwards.

HOOVER ALYX - Remove hood - 4

IMPORTANT: Switch cleaner off and remove plug from electricity supply before checking the brushes or removing hood.

HOOVER ALYX - Remove hood - 5

Replace belt

Locate the new belt around the motor spindle then around the brush.

HOOVER ALYX - Replace belt - 1

Locate the left hand end of the brush in cleaner housing.

HOOVER ALYX - Replace belt - 2

Hold the brush assembly and stretch the belt until brush mountings slot down into the cleaner housing.

HOOVER ALYX - Replace belt - 3

Rotate the brush to ensure free movement of the belt.

HOOVER ALYX - Replace belt - 4

Refit hood.

Secure hood, using screws.

CLEARING A BLOCKAGE

HOOVER ALYX - CLEARING A BLOCKAGE - 1

IMPORTANT: Switch the cleaner off and remove the plug from the electricity supply before dismantling cleaner.

This cleaner is unlikely to become blocked, except by overfilling of the dust container or accidentally picking up large solid objects. Clearing a blockage is simple.

HOOVER ALYX - CLEARING A BLOCKAGE - 2

If cleaning tools were in use, check cleaning tool. Next check hose handgrip.

HOOVER ALYX - CLEARING A BLOCKAGE - 3

Turn the cleaner ON and stretch the hose to its full length.

HOOVER ALYX - CLEARING A BLOCKAGE - 4

Check that the brushes are free of debris and can rotate.

HOOVER ALYX - CLEARING A BLOCKAGE - 5

Check for a blockage in the hose socket.

Genuine HOOVER spares

Tel. 01204 556 III

Always replace parts with genuine Hoover spares. These are available from your local Hoover dealer or direct from Hoover. When ordering parts always quote your model number.

Hoover service

Tel. 08705 400 600

Should you require service at any time please call the HOOVER Service Office.

Hoover have a computerised nationwide service network of over 500 engineers who will respond quickly to your call and guarantee your repair for 12 months.

Hoovercare

To maintain your HOOVER product in peak condition you may also wish to take out a Hoovercare policy, for which an annual payment provides a comprehensive maintenance and repair scheme. For further information telephone the HOOVER Service Office.

Quality, Safety & Environment

As the owner of a new Hoover product we would like to tell you more about the high standards we have set in Quality, Safety and the Environment.

HOOVER ALYX - Quality, Safety & Environment - 1

Environment - WEEE Directive

This appliance is marked according to the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE)

By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.

The symbol on the product indicates that this product may not be treated as household waste. Instead it shall be handed over to the appliance collection point for the recycling of electrical and electronic equipment.

Disposal must be carried out in accordance with local environment regulations for waste disposal.

For more detailed information about treatment, recovery and recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

GUARANTEE STATEMENT

The guarantee conditions for this appliance are as defined by our representative in the country in which it is sold. Details regarding these conditions can be obtained from the dealer from whom the appliance was purchased, the bill of sale or receipt must be produced when making any claim under the terms of this guarantee.

Subject to change without notice.

Use only HOOVER spares

SPARE PARTSCODE
FILTER KITU39 - 35600441
BELTV28 - 35600442
AGITATORY19 - 35600443
HOSED88 - 35600444

Safety

Although safety certification of electrical appliances is not required by law in the UK, Hoover believe that independent approval is the best way of demonstrating safety in design and manufacture.

The British Electrotechnical Approvals Board (BEAB), the independent UK national authority for the safety of domestic electrical appliances, ensure that European Safety Standards are met and are maintained throughout the production life of the appliance.

All appliances which pass these tests are permitted to carry this BEAB mark of safety.

BEAB Approved

Quality

BSI ISO900I

Hoover's factories have been independently assessed for quality.

Our products are made using a quality system which meets the requirements of ISO 9001.

Filter Maintenance

Tore-establish the original condition, please follow these steps:

  1. Rinse filters under hand warm water.
  2. Do not scrub the filters.
  3. Remove the excess water with a dry cloth and leave to air dry for 24 hours.

HOOVER ALYX - Filter Maintenance - 1

Remove pre-motor filter.

HOOVER ALYX - Filter Maintenance - 2

Remove separator screen.

HOOVER ALYX - Filter Maintenance - 3

Wash the pre-motor filter under hand warm water and leave to air dry for 24 hours or until completely dry.

Do not scrub or brush the filter as permanent damage will occur.

User checklist

If your cleaner is not working properly run through the following checklist.

  1. Is there a working electricity supply to the cleaner?

Check with another electrical product.

  1. Is the dust container full or choked with fine dust?

To empty the dust container see the instructions on page 5/6.

  1. Is the hose blocked?

To clear a blockage, see the instructions on page 7.

  1. Is there a blockage in the cleaner base?

To clear a blockage, see the instructions on page 7.

5.Are the filters blocked?

To clear the filters, see the instructions on page 6.

6.Are the brushes rotating correctly?

To check the brushes, see the instructions on page 7.

  1. Has the cleaner overheated? If so, it will take about 45 minutes to reset itself.

If there is any doubt call the Hoover Service Office for advice. They may be able to assist you over the telephone.

A service charge will be made if the cleaner is examined and found to be in working order, has not been assembled in accordance with these instructions or has been used incorrectly.

WARNING!

A thermal cut out switches off the cleaner to prevent overheating if it is used when full or there is a blockage or dirty filters. If this should happen switch off, unplug and correct the fault.

It will take about 45 minutes for the cut out to automatically reset.