HGL64SCF XWA - Boiler HOOVER - Free user manual and instructions
Find the device manual for free HGL64SCF XWA HOOVER in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Boiler |
| Brand | Hoover |
| Model | HGL64SCF XWA |
| Mounting Type | Wall-mounted |
| Energy Source | Natural gas (also compatible with LPG) |
| Power Supply | 230 V ~ 50 Hz |
| Heating Output (Maximum) | 24 kW |
| Domestic Hot Water Flow Rate | 10 L/min at ΔT 30 °C |
| Maximum Water Pressure | 3 bar |
| Heating Temperature Range | 35 °C – 80 °C |
| Hot Water Temperature Range | 35 °C – 60 °C |
| Expansion Vessel Capacity | 8 L |
| Control Panel | Electronic with LCD display |
| Ignition System | Electronic spark ignition |
| Safety Systems | Flame failure protection, overheat protection, frost protection, pressure relief valve |
| Water Connection Size | G 1/2" BSP |
| Gas Connection Size | G 1/2" BSP |
| Dimensions (H × W × D) | 700 × 400 × 300 mm |
| Weight | 30 kg |
| Maintenance | Annual servicing recommended by a qualified engineer |
| Cleaning | Wipe external casing with a soft damp cloth; do not use abrasive cleaners |
| Spare Parts Availability | Genuine spare parts available from Hoover certified service centers |
| Repairability | Repairable design with accessible internal components |
| Condensing Technology | High efficiency condensing |
| Certification | CE marked |
Frequently Asked Questions - HGL64SCF XWA HOOVER
How do I reset my Hoover HGL64SCF XWA boiler after an error?
Press and hold the reset button on the control panel for 3 seconds. If the error persists, check the water pressure and ensure the gas supply is open.
What should the water pressure be on my boiler?
The recommended water pressure when cold is between 1 and 1.5 bar. If the pressure falls below 0.5 bar, you may need to repressurize the system using the filling loop.
How do I repressurize the boiler?
Locate the filling loop under the boiler, open the valve slowly until the pressure gauge reads 1.5 bar, then close the valve completely. Always do this with the boiler turned off and cooled down.
How do I bleed a radiator with this boiler?
Turn off the heating, use a radiator key to open the bleed valve slightly until air escapes and water starts to flow, then close the valve. Check the boiler pressure afterward and top up if necessary.
What does the frost protection function do?
The frost protection mode automatically activates the pump and burner when the system temperature drops below 5 °C to prevent freezing of pipes and components.
Can I use the boiler with LPG?
Yes, the HGL64SCF XWA can be converted for use with LPG. This conversion must be carried out by a qualified technician. The LPG conversion kit is available as an accessory.
How often should I have the boiler serviced?
It is recommended to have your boiler serviced annually by a certified engineer to ensure safe and efficient operation and to maintain warranty coverage.
What is the maximum heating output of this boiler?
The maximum heating output is 24 kW, suitable for medium-sized homes. The boiler modulates down to a minimum output for efficient operation during milder weather.
Where can I find spare parts for the HGL64SCF XWA?
Genuine spare parts can be ordered from Hoover authorized service centers. Use the model number HGL64SCF XWA for reference.
Is the boiler covered by a warranty?
Hoover boilers typically come with a 2-year manufacturer's warranty from the date of installation. Registration may be required. Check your local dealer for details.
User questions about HGL64SCF XWA HOOVER
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Boiler in PDF format for free! Find your manual HGL64SCF XWA - HOOVER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HGL64SCF XWA by HOOVER.