Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Shaver
Brand Philips
Model AquaTouch AT760
Power Source Rechargeable battery
Charging Time 1 hour
Runtime 50 minutes
Shaving System Rotary
Wet/Dry Use Yes
Pop-up Trimmer Yes
Waterproof Rating IPX7 (fully washable)
Cleaning Rinse under tap
Display LED charge indicator
Replacement Head Philips SH30/50 series
Weight Approx. 0.5 kg (1.1 lbs)
Dimensions 15.5 x 6.5 x 5 cm (6.1 x 2.6 x 2.0 in)
Package Contents Shaver, charging cord, cleaning brush, protective cap
Safety Features Skin protection system, floating heads
Warranty 2 years (check local policy)

Frequently Asked Questions - AquaTouch AT760 PHILIPS

How do I clean the Philips AquaTouch AT760?
Rinse the shaver under warm water after each use. Remove the shaving head for a thorough clean. Do not use abrasive cleaners. Refer to the manual for detailed cleaning instructions.
Is the AquaTouch AT760 waterproof?
Yes, it has an IPX7 rating, meaning it can be fully submerged in water and used in the shower for a refreshing wet shave.
How long does the battery last and how do I charge it?
The shaver offers about 50 minutes of cordless use after a full charge. Charging takes approximately 1 hour. Connect the provided charging cord to the shaver and plug into a power outlet.
Can I use the shaver while it is charging?
No, the AquaTouch AT760 cannot be used while plugged in. It is designed for cordless operation only.
When should I replace the shaving heads?
Replace the shaving heads every 12 months or when performance declines. Use Philips SH30/50 replacement heads for optimal performance.
What is the pop-up trimmer for?
The pop-up trimmer is ideal for trimming sideburns, mustaches, and detailing edges. Push the slider on the side to lift the trimmer.
How do I replace the shaving heads?
Turn off and unplug the shaver. Press the release button to open the shaving unit. Remove the old heads and snap in new ones. Close the unit until it clicks. See manual for visual instructions.
What does the LED indicator mean?
The LED lights show battery status: while charging, it blinks; fully charged, it stays on steadily. A low battery may blink red. Refer to the manual for indicator details.
Can I use shaving cream with the AquaTouch AT760?
Yes, it is designed for both dry and wet use. Apply shaving gel or cream for a more comfortable wet shave.
Where can I find replacement parts or accessories?
Official Philips replacement parts and accessories are available online or at authorized retailers. Look for SH30/50 shaving heads and compatible charging cords.

User questions about AquaTouch AT760 PHILIPS

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Razor in PDF format for free! Find your manual AquaTouch AT760 - PHILIPS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AquaTouch AT760 by PHILIPS.

USER MANUAL AquaTouch AT760 PHILIPS

Always here to help you

Register your product and get support at

www.philips.com/welcome

Question? Contact Philips

AT9X X

AT8X X

AT7X X

Close-up of a Philips Aquatonic electric shaver with three circular buttons and a power button (no text or symbols on the device body)

PHILIPS

Technical diagram of an electric shaver with numbered parts and labeled parts for identification.

ENGLISH 4

INDONESIA 17

KOREAN 31

MALAY 44

THAI 58

VIETNAMESE 71

TRADITIONAL CHINESE 84

SIMPLIFIED CHINESE 97

PHILIPS AquaTouch AT760 - Always here to help you - 4

PHILIPS AquaTouch AT760 - Always here to help you - 5

121

133

Introduction

Congratulations on your purchase and welcome to Philips! To fully benefit from the support that Philips offers, register your product at www.philips.com/welcome.

Please read this user manual, as it contains information about the wonderful features of this shaver as well as some tips to make shaving easier and more enjoyable.

General description (Fig. 1)

1 Protection cap 2 Shaving unit 3 Shaving unit release button 4 Shaver on/off button (AT899/AT896/AT894/AT892/AT891/AT890/AT811/AT790/AT756/AT753/AT751/AT750 only) 5 Shaving head symbol 6 Charging light (AT899/AT896/AT894/AT892/AT891/AT890/AT811/AT790/AT756/AT753/AT751/AT750 only) 7 Charging stand (AT941/AT940 only) 8 Adapter 9 Cleaning brush 10 Storage pouch (AT941/AT940/AT897/AT894/AT891/AT890/AT796/AT790 only) 11 Battery symbol and shaving head symbol (AT941/AT940/AT897 only) 12 Shaver on/off button (AT941/AT940/AT897 only) 13 Trimmer release slide (AT941/AT940/AT918/AT897/AT896/AT894/AT891/AT890/AT889/AT887/AT886/AT872/AT811/AT799/AT797/AT796/AT790/AT756 only) 14 Trimmer (AT941/AT940/AT918/AT897/AT896/AT894/AT891/AT890/AT889/AT887/AT886/AT872/AT811/AT799/AT797/AT796/AT790/AT756 only)

Note: You can find the type number on the back of the shaver.

Important safety information

Read this important information carefully before you use the appliance and its accessories and save it for future reference. The accessories supplied may vary for different products.

Danger

- Keep the adapter dry.

Warning

  • The adapter contains a transformer. Do not cut off the adapter to replace it with another plug, as this causes a hazardous situation.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Always unplug the shaver before you clean it under the tap.
  • Always check the appliance and its accessories before you use it. Do not use the appliance or its accessories if it is damaged, as this may cause injury. Always replace a damaged part with one of the original type.

Prohibition sign showing a faucet without a shower, enclosed in a circle (no text or symbols)

Prohibition sign of a faucet with no text or symbols

Caution

  • Never immerse the charging stand in water nor rinse it under the tap.
  • Only use this appliance for its intended purpose as shown in the user manual.
  • For hygienic reasons, the appliance should only be used by one person.
  • Do not use the adapter in or near wall sockets that contain or have contained an electric air freshener to prevent irreparable damage to the adapter.
  • Never use compressed air, scouring pads, abrasive cleaning agents or aggressive liquids such as petrol or acetone to clean the appliance.
  • Water may drip from the socket at the bottom of the shaver when you rinse it. This is normal and not dangerous because all electronics are enclosed in a sealed power unit inside the shaver.

Electromagnetic fields (EMF)

- This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic fields.

General

  • This shaver is waterproof. It is suitable for use in the bath or shower and for cleaning under the tap. For safety reasons, the shaver can therefore only be used without cord.
  • The appliance is suitable for mains voltages ranging from 100 to 240 volts.
  • The adapter transforms 100-240 volts to a safe low voltage of less than 24 volts.

PHILIPS AquaTouch AT760 - General - 1

Charging

Note: The shaver cannot be used directly from the mains.

When you charge the shaver for the first time or after a long period of disuse, let it charge until the charging light lights up continuously. See the table below for the charging time of your shaver.

Charging time 1 hour 8 hours

AT941, AT940, AT918AT899, AT896, AT872,
AT897, AT896, AT894AT799, AT797, AT796,
AT892, AT891, AT890AT790, AT770, AT756,
AT889, AT887, AT886AT753, AT751, AT750
AT811

The shaving time may be less than stated below in the table as a result of your shaving behaviour, your cleanings habits or your beard type.

Shaving minutes60 min. 50 min. 45 min. 40 min.
AT941 AT899ATT7897,AT7894,AT892AT753
AT940AT891, AT890, AT811,AT896 AT751, AT750

Charge indications

Diagram illustrating battery charging with a lightning bolt icon and power symbol, showing charging path and charge distribution.

Battery low

- AT941/AT940/AT897: When the battery is almost empty (when there are only 5 or fewer shaving minutes left), the orange battery symbol starts to flash. When you switch off the shaver, the orange battery symbol continues to flash for a few seconds.

Diagram of a medical or electrical device with curved lines and a central power button, featuring a star-shaped symbol (no text or labels)

- AT899, AT896, AT918, AT896, AT894, AT891, AT890, AT889, AT887, AT886, AT872, AT811, AT799, AT797, AT796, AT790, AT770, AT756, AT753, AT751, AT750: When the battery is almost empty (when there are only 5 or fewer shaving minutes left), the charging light starts to flash orange. When you switch off the shaver, the charging light continues to flash orange for a few seconds.

Diagram illustrating battery charging with a lightning bolt and power button, showing charging signal paths and a star symbol.

Quick charging (AT941, AT940, AT918, AT897, AT896, AT894, AT891, AT890, AT889, AT887, AT886, AT811 only)

- AT941/AT940/AT897: When you start charging the empty battery, the battery symbol flashes orange and white.

Note: When the battery symbol flashes white and orange towards only white, you can have a quick shave of three minutes.

Diagram of a medical or electrical device with curved lines and a central star-like symbol (no text or labels)

- AT918, AT896, AT894, AT891, AT890, AT889, AT887, AT886, AT811: When you start charging the empty battery, the charging light alternately flashes orange and green.

Note: When the charging light flashes orange and green towards only green, you can have a quick shave of three minutes.

Diagram illustrating battery charging mechanism with labeled components and charging symbol

Charging

- AT941/AT940/AT897: When the shaver is charging, the white battery symbol flashes.

Diagram of a medical or electrical device with curved lines and a central star-like symbol, no text or labels present.

- AT899, AT896, AT872, AT799, AT797, AT796, AT790, AT770, AT756, AT753, AT751, AT750:

When the shaver is charging, the charging light flashes green.

Diagram showing a battery icon with lightning bolt and power button, illustrating charging or discharging process.

Battery fully charged

- AT941/AT940/AT897: When the battery is fully charged, the white battery symbol lights up continuously.

Note: After approx. 30 minutes, the battery symbol goes out to save energy.

Diagram of a medical or electrical device with curved lines and a central circular component, no text or symbols present.

- AT899, AT896, AT918, AT896, AT894, AT891, AT890, AT889, AT887, AT886, AT872, AT811, AT799, AT797, AT796, AT790, AT770, AT756, AT753, AT751, AT750: When the battery is fully charged, the charging light lights up green continuously.

Note: After approx. 30 minutes, the charging light goes out to save energy.

Charging

1 Put the small plug in the shaver.

2 Put the adapter in the wall socket.

The charging light shows the charging status of the shaver (see section 'Charge indications' in this chapter).

Charging in the charging stand (AT941/AT940 only)

1 Put the small plug in the charging stand. 2 Put the adapter in the wall socket.

Close-up of a handheld device with a black arrow pointing to a circular base (no text or symbols visible)

3 Place the shaver in the charging stand.

The charging light shows the charging status of the shaver (see section 'Charge indications' in this chapter).

Using the shaver

Note: This shaver can be used in the bath or shower. It can therefore not be used directly from the mains for safety reasons.

Shaving tips and tricks

- This shaver is suitable for both wet and dry use. Use the shaver with shaving gel or foam for extra skin comfort, or use the shaver dry for extra convenience.

Note: We advise you to use the shaver with shaving gel or foam when you use it for a wet shave. Do not use thick shaving cream or shaving oil with this shaver.

- For optimal shaving results, make circular movements during use.

- The shaver is waterproof and can be used in the bath or shower.

- Your skin may need 2 or 3 weeks to get accustomed to the Philips shaving system.

Wet shaving

Line drawing of a person applying facial massage or pressure to the ear (no text or symbols)

1 Apply some water to your skin.

Line drawing of a person applying a sponge to their ear.

2 Apply shaving foam or shaving gel to your skin. 3 Rinse the shaving unit under the tap to ensure that the shaving unit glides smoothly over your skin. 4 Press the on/off button once to switch on the shaver. 5 Move the shaving heads in circular movements over your skin.

Illustration of a person using a handheld device to lift a rolled-up cable.

Note: Rinse the shaver under the tap regularly to ensure that it continues to glide smoothly over your skin.

6 After shaving, press the on/off button once to switch off the shaver and dry your face. 7 Clean the shaver (see chapter 'Cleaning and maintenance').

Note: Make sure you rinse all foam or shaving gel off the shaver.

Dry shaving

Illustration of a person using a handheld device to clean another.

1. Press the on/off button once to switch on the shaver. 2. Move the shaving heads in circular movements over your skin. 3. After shaving, press the on/off button once to switch off the shaver. 4. Clean the shaver (see chapter 'Cleaning and maintenance').

Trimming (AT941/AT940/AT918/AT897/AT896/AT894/AT891/AT890/AT889/AT887/AT886/AT872/AT811/AT799/AT797/AT796/AT790/AT756 only)

Diagram of a hairdryer with a brush and lever mechanism.

You can use the trimmer to groom your sideburns and moustache.

1. Push the trimmer slide downwards to open the trimmer. 2. Press the on/off button once to switch on the shaver. You can now start trimming. 3. After trimming, press the on/off button once to switch off the shaver.

Illustration of a hand using a tool to adjust or install a component, with arrows indicating direction.

4. Clean the trimmer (see chapter 'Cleaning and maintenance').

Diagram of a device being inserted into a component, showing a finger and arrow indicating insertion.

5. Close the trimmer ('click').

Cleaning and maintenance

Never use compressed air, scouring pads, abrasive cleaning agents or aggressive liquids such as petrol or acetone to clean the shaver and the charging stand (AT941/AT940 only).

Always unplug the shaver before you clean it under the tap.

  • Clean the shaver after every shave for optimal shaving performance.
  • Regular cleaning guarantees better shaving performance.
  • For the best cleaning results, we advise you to use the Philips Cleaning spray (HQ110).
  • Be careful with hot water. Always check if the water is not too hot, to prevent your hands from getting burnt.

Note: Water may leak from the socket at the bottom of the shaver when you rinse it. This is normal and not dangerous because all electronics are enclosed in a sealed power unit inside the shaver.

Cleaning the shaving unit under the tap

Illustration of a person assembling mechanical parts with arrows indicating assembly direction.

1 Switch off the shaver. 2 Press the release button to open the shaving unit. 3 Rinse the shaving unit and hair chamber under a hot tap for 30 seconds.

Be careful with hot water. Always check if the water is not too hot, to prevent your hands from getting burnt.

Diagram of a medical procedure showing fluid flow from a pipette into a device with internal components.

- Rinse the hair chamber and the inside of the shaving unit.

Illustration of a mechanical device pouring liquid into a container.

- Rinse the outside of the shaving unit.

4 Close the shaving unit and shake off excess water.

Be careful not to hit the shaving unit against anything while shaking off excess water.

Never dry the shaving unit and the hair chamber with a towel or tissue, as this may damage the shaving unit.

5 Open the shaving unit again and leave it open to let the shaver dry completely.

Cleaning the shaving unit with the cleaning brush

Illustration of a hand holding a mechanical component with arrows indicating direction.

1 Switch off the shaver.

2 Press the release button to open the shaving unit.

Diagram of a mechanical component with an arrow indicating direction, showing internal parts and a top view.

3 Pull the shaving unit off the shaver.

Diagram showing mechanical assembly with labeled parts A and B, likely illustrating a gear or cam mechanism.

4 Turn the lock anticlockwise (A) and remove the retaining frame (B).

Illustration of a hand holding a tray with three round objects and upward arrows.

5 Remove and clean one shaving head at a time. Each shaving head consists of a cutter and a guard.

Note: Do not clean more than one cutter and guard at a time, since they are all matching sets. If you accidentally mix up the cutters and guards, it may take several weeks before optimal shaving performance is restored.

- Remove the cutter from the shaving guard and clean it with the brush.

Illustration of a mechanical assembly with two views: top shows a gear-like component, bottom shows three circular components.

- Clean the inside and outside of the shaving guard with the brush.

Illustration of a hand holding a small bowl with a downward arrow, next to a circular object.

6 Put the shaving heads back into the shaving unit.

Diagram illustrating a food preparation step with labeled steps and a hand holding a bowl containing food items.

Make sure that the projections of the shaving heads fit exactly into the recesses.

A B

7 Put the retaining frame back into the shaving unit (A) and turn the lock clockwise (B).

Diagram showing two views of a mechanical component with arrows indicating direction (no text or symbols)

8 Insert the lug of the shaving unit into the slot in the top of the shaver. Then close the shaving unit.

Note: If the shaving unit does not close smoothly, check if you have inserted the shaving heads properly and if the retaining frame is locked.

Cleaning the trimmer with the cleaning brush (AT941/AT940/AT918/AT897/AT896/AT894/AT891/AT890/AT889/AT887/AT886/AT872/AT811/AT799/AT797/AT796/AT790/AT756 only)

Diagram of a hairdryer with directional arrows indicating movement or force (no text or symbols)

Clean the trimmer every time you have used it.

1 Switch off the shaver. 2 Push the trimmer slide downwards to open the trimmer.

Illustration of a hand holding a tool with arrows indicating motion or force (no text or symbols)

3 Clean the trimmer with the short-bristled side of the cleaning brush. Brush up and down along the trimmer teeth. 4 Close the trimmer ('click').

OIL

Tip: For optimal trimming performance, lubricate the trimmer teeth with a drop of sewing machine oil every six months.

Storage

Diagram of a hand turning a three-pin electric shaver (no text or symbols present)

- Put the protection cap on the shaver to prevent damage. - AT941/AT940/AT897/AT894/AT892/AT891/AT890/AT796/AT790 only: Store the shaver in the pouch supplied.

Replacement

Replacement reminder

The shaving head symbol will light up to indicate that the shaving heads need to be replaced. Replace damaged shaving heads right away. Only replace the shaving heads with original HQ9 (AT941/AT940/AT918) or HQ8 (AT897/AT896/AT894/AT891/AT890/AT889/AT887/AT886/AT872/AT811/AT797/AT796/AT790/AT770/AT756/AT753/AT751/AT750) Philips Shaving Heads.

Illustration of a hand holding a small object with a circular arrow indicating rotation (no text or symbols present)

1 The shaving head symbol lights up orange continuously. 2 Switch off the shaver. Disconnect the shaver from the mains or remove it from the charging stand (AT941/AT940 only). 3 Press the release button to open the shaving unit. 4 Pull the shaving unit off the shaver.

Illustration of a hand holding a mechanical component with arrows indicating direction (no text or symbols)

5 Turn the lock anticlockwise (A) and remove the retaining frame (B). 6 Remove the shaving heads and place new ones in the shaving unit.

Diagram showing mechanical components labeled A and B with directional arrows indicating motion or force

Make sure that the projections of the shaving heads fit exactly into the recesses.

Illustration showing a food item being cut off by a hand using a bowl (no text or symbols present)

7 Put the retaining frame back into the shaving unit (A) and turn the lock clockwise (B).

A B

Medical illustration showing two views of a surgical instrument with arrows indicating movement (no text or labels)

16% 5 sec. PHILIPS PHILIPS

8 Insert the lug of the shaving unit into the slot in the top of the shaver. Then close the shaving unit.

Note: If the shaving unit does not close smoothly, check if you have inserted the shaving heads properly and if the retaining frame is locked.

9 Press and hold the on/off button for 5 seconds to reset the replacement reminder on the shaver. The orange light will go out.

Ordering accessories

To buy accessories or spare parts, visit www.shop.philips.com/service or go to your Philips dealer. You can also contact the Philips Consumer Care Centre in your country (see the worldwide guarantee leaflet for contact details).

To retain the top performance of your shaver, make sure you clean it regularly and replace its shaving heads at the recommended time.

Shaving heads

- We advise you to replace your shaving heads every two years. Always replace with HQ9 (AT941/AT940) or HQ8 (AT897/AT896/AT894/AT891/AT890/AT889/AT887/AT886/AT872/AT811/AT799/AT797/AT796/AT790/AT770/AT756/AT753/AT751/AT750) Philips Shaving Heads.

Cleaning

- Use Cleaning spray (HQ110) to clean the shaving heads thoroughly.

Recycling

Do not throw away the appliance with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preserve the environment.

Removing the rechargeable shaver battery

Only remove the rechargeable battery when you discard the shaver. Make sure the rechargeable battery is completely empty when you remove it.

1 Undo the screws in the back of the shaver and in the hair chamber. 2 Remove the front panel and the back panel.

2yrs

3 Bend the 6 hooks aside and take out the power unit. Be careful, the hooks are sharp. 4 Remove the rechargeable battery.

Guarantee and support

If you need information or support, please visit www.philips.com/support or read the separate worldwide guarantee leaflet.

Guarantee restrictions

The shaving heads (cutters and guards) are not covered by the terms of the international guarantee because they are subject to wear.

Troubleshooting

This chapter summarises the most common problems you could encounter with the appliance. If you are unable to solve the problem with the information below, visit www.philips.com/support for a list of frequently asked questions or contact the Consumer Care Centre in your country.

Problem Possible cause Solution

The shaver does not shave as well as it used to.The shaving heads are damaged or worn.Replace the shaving heads (see chapter ‘Replacement’).
Foam or gel residues clog up the shaving heads.Rinse the shaving unit under a hot tap (see chapter ‘Cleaning and maintenance’).
Long hairs obstruct the shaving heads.Clean the shaving heads one by one (see chapter ‘Cleaning and maintenance’).
You have not inserted the shaving heads properly.Make sure that the projections of the shaving heads fit exactly into the recesses (see chapter ‘Cleaning and maintenance’).
The shaver does not work when I press the on/off button.The rechargeable battery is empty.Recharge the battery (see chapter ‘Charging’).
The temperature of the shaver is too high. In this case, the shaver does not work.As soon as the temperature of the shaver has dropped sufficiently, you can switch on the shaver again.
The shaver does not work, although it is connected to the mains.The shaver is not designed to be used directly from the mains.Recharge the battery (see chapter ‘Charging’) and disconnect it from the mains.

Introduction

Prohibition sign showing a faucet without shower, enclosed in a circle (no text or symbols)

Diagram illustrating battery charging and power output with labeled icons and a lightning bolt symbol

Diagram of a stylized human head with a power button and star-shaped symbol inside, no text or labels present.

Diagram illustrating battery charging and power connection with labeled icons and a star-shaped symbol

Charging

- AT941/AT940/AT897: When the shaver is charging, the white battery symbol blinks.

Diagram of a medical or surgical device with a power button and star-shaped stimulus (no text or symbols)

- AT899, AT896, AT872, AT799, AT797, AT796, AT790, AT770, AT756, AT753, AT751, AT750:

Battery full

- AT941/AT940/AT897: When the battery is fully charged, the white battery symbol lights up continuously.

- AT899, AT896, AT918, AT896, AT894, AT891, AT890, AT889, AT887, AT886, AT872, AT811, AT799, AT797, AT796, AT790, AT770, AT756, AT753, AT751, AT750: When the battery is fully charged, the charging light stays green.

1 Insert the small plug into the charging stand. 2 Insert the adapter into the wall socket. 3 Place the shaver in the charging stand.

Illustration of a person using a medical or cosmetic device to interact with a bag, showing a hand holding a bottle and a circular button labeled 'Return'.

Illustration of a hand holding a tray with three round objects and upward arrows, no text or symbols present.

Illustration of a mechanical assembly with two parts: one showing a gear-like component being inserted, the other showing a bowl with holes (no text or symbols).

Illustration of a hand holding a small mechanical component with a magnified inset showing a circular component (no text or symbols).

Diagram illustrating a hand holding a container with a magnified view of the lid and a mechanical component, with arrows indicating steps.

OIL

Prohibition sign showing a faucet crossed out by a diagonal line, indicating no fire or water discharge.

Simple line drawing of a showerhead spraying over a water-filled basin.

Low battery

Quick charge (only for models AT941, AT940, AT918, AT897, AT896, AT894, AT891, AT890, AT889, AT887, AT886, AT811)

Charging

- AT899, AT896, AT872, AT799/AT797, AT796, AT790, AT770, AT756, AT753, AT751, AT750:

Battery fully charged

1 Wet your skin with water.

Line drawing of a person applying a sponge to their face (no text or symbols)

Diagram of a medical procedure showing fluid flow from a pipette into a device (no text or labels)

Illustration of a medical procedure showing fluid flow from a bottle onto a patient's foot (no text or symbols)

1 Switch off the shaver.

Replacement reminder

Prohibition sign showing a faucet without shower, enclosed in a circle.

Diagram illustrating battery charging with a lightning bolt icon and power button, showing charging path and safety symbol.

Diagram of a stylized human head with a star-shaped symbol and power button.

Diagram illustrating battery charging with a lightning bolt icon and power button, showing charging path and charging symbol.

Diagram of a stylized smiley face with curved lines and a power button, no text or symbols present.

Low battery

Charging

- AT941/AT940/AT897: When the shaver is charging, the white battery symbol will blink.

Diagram of a stylized smiley face with curved lines and a power button, no text or symbols present.

- AT899, AT896, AT872, AT799/AT797, AT796, AT790, AT770, AT756, AT753, AT751, AT750:

- AT899, AT896, AT918, AT896, AT894, AT891, AT890, AT889, AT887, AT886, AT872, AT811, AT799, AT797, AT796, AT790, AT770, AT756, AT753, AT751, AT750: When the battery is fully charged, the charging light will turn solid green.

Note: After approximately 30 minutes, the charging light will go out to save energy.

Charging

5 Close the trimmer ('click').

1 Switch off the shaver. 2 Press the release button to open the shaving unit.

Diagram of a mechanical component with an arrow indicating direction, showing internal parts and a top view (no text or symbols)

4 Turn the lock counterclockwise (A) and remove the retaining frame (B).

Illustration of a hand holding a tray with three circular objects and upward arrows, no text or symbols present.

Illustration of a mechanical assembly with two views: top shows a gear-like component, bottom shows three bowls (no text or symbols)

Illustration of a hand placing a small bowl into a tray with a downward arrow, no text or symbols present

Diagram illustrating food preparation steps with labeled icons and arrows indicating steps to prepare a turtle.

A B

8 Insert the tabs of the shaving unit into the slots on the top of the shaver. Then close the shaving unit.

  • Reattach the protective cap to the shaver to prevent damage.
  • AT941/AT940/AT897/AT894/AT892/AT891/AT890/AT796/AT790 only: Store the shaver in the pouch provided.

Replacement

Illustration of a hairbrush with a circular icon highlighting the brush tip (no text or symbols present)

8 Insert the shaving unit's tabs into the space at the top of the shaver. Then close the shaving unit.

No sign depicting a faucet with a showerhead, crossed out by a diagonal line (no text or symbols).

PHILIPS AquaTouch AT760 - Replacement - 3

Caution

Diagram of a medical or electrical device with a power button and star-shaped components (no text or symbols).

Diagram illustrating battery charging with a lightning bolt icon and power button, showing charging process flow.

Diagram of a medical or electrical device with a power button and star-shaped stimulus (no text or symbols).

Diagram illustrating battery charging mechanism with labeled components and charging symbol.

Illustration of a hand holding a tray with three small food items, each with an upward arrow indicating growth (no text or symbols present)

Illustration of a mechanical assembly with two parts: one showing a gear-like component being inserted, the other showing a bowl with holes (no text or symbols)

Illustration of a hand holding a small mechanical component with a magnified inset showing a circular component.

Diagram illustrating a hand holding a container with a magnified view of the lid and a turtle-shaped object, with arrows indicating steps.

No smoking sign with faucet symbol.

Simple line drawing of a showerhead spraying over a water-filled basin.

Battery

Diagram of a medical or electrical device with curved lines and a power button. No text or symbols.

Diagram showing a battery icon with lightning bolt and power button, illustrating charging or discharging process.

Diagram of a medical or electrical device with curved lines and a central circular component. No text or symbols.

Charging the battery

A B

Medical illustration showing two views of a surgical instrument with arrows indicating movement (no text or labels).

5 sec. 10% PHILIPS PHILIPS

Prohibition sign showing a faucet without a shower, enclosed in a circle (no text or symbols).

PHILIPS AquaTouch AT760 - Charging the battery - 5

Warning

Diagram of a stylized smiley face with curved lines and a power button, no text or symbols present.

Diagram illustrating battery charging with a lightning bolt icon and power button, showing charging signal paths and power source.

Diagram of a medical or electronic device with a power button and star-shaped stimulus symbol (no text or labels).

Diagram illustrating battery charging with a lightning bolt icon and power button, showing charging process flow.

Battery fully charged

Line drawing of a person applying a product to their face, showing the tooth and mouth area (no text or symbols).

Illustration of a person using a medical device to interact with a device, showing a circular arrow and rope (no text or symbols).

1 Apply some water to your skin.

You can use the trimmer to trim sideburns and mustache.

5 Turn off the trimmer (it clicks).

Cleaning and maintenance

Diagram of a medical procedure showing fluid flow from a tube into a device (no text or labels).

Diagram of a mechanical device pouring liquid into a container (no text or symbols).

3 Pull the shaving head from the shaver.

Diagram showing mechanical assembly with labeled parts A and B, indicating a gear or mechanism.

6 Attach the shaving head back to the shaver.

Diagram illustrating a food preparation step with labeled steps and arrows indicating action

Clean the trimmer after each use.

Replacement reminder

Prohibition sign showing a faucet without a shower, enclosed in a circle (no text or symbols)

PHILIPS AquaTouch AT760 - Replacement reminder - 2

Warning

Diagram of a medical or electrical device with a power button and star-shaped components (no text or symbols).

Diagram illustrating battery charging and power connection with labeled icons and arrows.

Diagram of a stylized smiley face with curved lines and a power button, no text or symbols present.

Diagram illustrating battery charging and power connection with labeled icons and signal paths.

Battery fully charged

Line drawing of a person applying a product to their face, no text or symbols present.

Illustration of a person using a device to interact with a mechanical component (no text or symbols visible).

1 Moisten your skin with water.

You can use the trimmer to trim sideburns and mustache.

5 Switch off the trimmer (you will hear a click).

Cleaning and maintenance

Diagram of a medical procedure showing fluid flow from a tube into a device (no text or labels).

Diagram of a mechanical device pouring liquid into a container (no text or symbols).

3 Pull the shaving head assembly out of the shaver.

Diagram showing mechanical assembly with labeled parts A and B, indicating a gear or component mechanism.

- Clean the outer cutter inside and out with the cleaning brush.

Illustration of a hand placing a small bowl into a tray with a downward arrow, no text or symbols present.

6 Put the shaving head back into the shaving head assembly.

Diagram illustrating a food preparation step with labeled steps and arrows indicating action.

Make sure the protrusions of the shaving head fit exactly into the recesses.

A B

Clean the trimmer after every use.

Replacement reminder

Make sure the protrusions of the shaving head fit exactly into the recesses.

A B

Reminder for replacement

Illustration of a person holding a mechanical component with arrows indicating movement (no text or symbols)

Diagram of a hairdryer with a brush applying material to the jaw (no text or symbols)

Illustration of a hand using a tool to adjust or install a component, with arrows indicating motion (no text or symbols present)

Oil

Diagram of a medical procedure showing a catheter inserted into a tube with internal tubing, no text or labels.

Illustration of a hand using a tool to adjust or install a mechanical component, no text or symbols visible.

Diagram of a hand using a tool to adjust or install a device component, with no visible text or symbols.

Cleaning and maintenance

Dry shaving

/AT756/AT790/AT811/AT890/AT891/AT892/AT894/AT896/AT899

Diagram showing battery charging process with battery icon and power button, illustrating charging sequence.

Diagram of a curved mechanical or electrical component with a power button and a circular component, no text or symbols present.

Close-up of a medical or laboratory device with a downward arrow and label 'Pilot' (no readable text or symbols beyond labels)

Using the shaver

5 sec. (0) PHILIPS PHILIPS

Ordering accessories

Ideal use

Illustration of a mechanical device with internal components and directional arrows indicating movement (no text or symbols)

Diagram of a hairdryer with black arrows indicating direction (no text or symbols)

Illustration of a hand using a tool to adjust or install a component, with arrows indicating motion (no text or symbols present)

OIL

Diagram of a medical procedure showing a tool injecting into a catheter inside a device (no text or labels present)

Illustration of a hand using a tool to adjust or install a component, with arrows indicating motion (no text or symbols present)

Diagram of a mechanical component with a tool inserted, showing internal parts and a downward arrow indicating direction (no text or symbols present)

Cleaning and maintenance

Dry face shaving

(for AT890/AT891/AT894/AT896/AT897/AT918/AT940/AT941) (only) AT756/AT790/AT796/AT797/AT811/AT872/AT886/AT887/AT889

Diagram showing battery charging with lightning bolt icon and power button, illustrating charging process flow

Diagram of a stylized human head with curved lines and a star-shaped symbol, no text or labels present.

Diagram showing battery charging with a power source and lightning bolt symbol, likely illustrating a charging mechanism or safety concept.

Diagram of a medical or electrical device with curved lines and a central star-like symbol, no text or labels present.

Introduction

Prohibition sign showing a faucet crossed out by a diagonal line, indicating no fire or water discharge (no text present).

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PHILIPS

Model : AquaTouch AT760

Category : Razor