ZANKER KHT 6241 x - Range hood

KHT 6241 x - Range hood ZANKER - Free user manual and instructions

Find the device manual for free KHT 6241 x ZANKER in PDF.

📄 24 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice ZANKER KHT 6241 x - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product typeKitchen extractor hood
BrandZanker
ModelKHT 6241 x
ColorStainless steel
Dimensions (W x D x H)600 x 500 x 100 mm
Weight10 kg
Power supply220-240 V, 50 Hz
Max extraction power250 m³/h
Noise level55 dB
Lighting2 LED of 1.5 W
Number of speeds3
Filter typeMetal filter and charcoal filter (optional)
Outlet diameter150 mm
Chimney heightAdjustable
Energy classA
FunctionsTimer, remote control
Maintenance and cleaningClean metal filters every month, replace charcoal filter every 3 months
SafetyAutomatic shut-off in case of overheating
Spare parts and repairabilityParts available on order
General information2-year warranty

Frequently Asked Questions - KHT 6241 x ZANKER

How to install the Zanker KHT 6241 x hood?
Installation must be carried out by a professional. Make sure to maintain a minimum distance of 65 cm between the hood and the cooking surface. Securely fix the hood to the wall or ceiling according to the provided instructions.
How to clean the hood filters?
Metal filters can be cleaned in the dishwasher or by hand with soapy water every 4 to 6 weeks. The charcoal filter must be replaced every 3 to 6 months.
The hood is noisy, what to do?
Check that the filters are not clogged. Clean the metal filters. If the noise persists, check that the hood is securely fixed and that the exhaust duct is not blocked.
How to turn on the hood lighting?
Press the lighting button on the control panel. The LED lighting is self-contained and does not require replacement.
The remote control does not work, what to do?
Replace the batteries in the remote control. Check that there is no obstacle between the remote control and the hood receiver. If the problem persists, contact customer service.
How to set the timer?
Press the Timer button to activate automatic shut-off after 10 minutes. You can adjust the duration by pressing the button multiple times (options: 10, 20, 30 minutes).
What is the diameter of the exhaust duct?
The outlet diameter is 150 mm. Use a rigid duct of the same diameter for optimal evacuation.
Can the hood operate in recirculation mode?
Yes, the hood can be used in recirculation mode with an activated charcoal filter (sold separately). In this case, the air is filtered and then returned to the room.
What is the power consumption of the hood?
The hood consumes approximately 150 W in normal operation. The LEDs consume 3 W in total.
How to get spare parts?
Contact Zanker customer service or visit their website. Spare parts such as filters, LED bulbs, and the remote control are available.

User questions about KHT 6241 x ZANKER

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Range hood in PDF format for free! Find your manual KHT 6241 x - ZANKER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. KHT 6241 x by ZANKER.

USER MANUAL KHT 6241 x ZANKER

This canopy hood is designed to be fixed to any rigid vertical surface, over a gas or electric hotplate and can be used either in the extraction mode (ducted to the outside) or in the recirculation mode (internal recycling). All cookers hood perform better when used in evacuation mode. During winter time it may be convenient to use the hood in the recycling mode to avoid heat loss from the kitchen. Before starting the installation, consideration should be given to the difficulties to be found during installation. The installation work must be undertaken by a qualified and competent person in conformity to the rules concerning the evacuation of contaminated air.

The manufacturer disclaims all liability for any damage or injury caused as a result of not following the instructions for installation contained in the following text.

1 - SAFETY WARNINGS

1.1 - When used in the extraction mode, the cooker hood ducting must not be connected to a flue which is used for exhausting fumes from appliances supplied with energy other than electric, such as a central heating flue or water heating flue.
1.2 - Before connecting to the mains supply ensure that the mains voltage corresponds with the voltage on the rating plate inside the hood.
1.3 - Connect the cooker hood to the mains via a bipolar switch which has 3mm clearance between the contacts.
1.4 - For cooker hoods featuring an earth cable, make sure the electric plant of your house is correctly earthed.
1.5 - Appliance in class II are provided with a double insulation; therefore do not connect then through earthed plugs but through simple bipolar plugs.
1.6 - When installed, the hood must be positioned at least 65cm above the hotplate.
1.7 - Never do flambé cooking under this cooker hood.
1.8 - Never leave frying pans unattended during use as overheated fat and oil may catch fire.
1.9 - Before carrying out any kind of maintenance or cleaning, disconnect the hood from the mains supply.
1.10 - If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type. If other types of flue or appliance are fitted, ensure that there is an adequate supply of air into the room. When the cooker hood is used in conjunction with appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0,04 mbar to prevent fumes being drawn back into the room by the cooker hood.
1.11 - The appliance must be positioned so that the plug is accessible.
1.12 - If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.

2 - INSTALLATION INSTRUCTIONS

Some installation systems require the opening and removal of the metal grille panel.

2.1 - Instructions for opening and removing the metal grille panel

To open the grille panel, press inwardly on the two slider catches at each side of the grille panel and the grille will pivot down.

To remove the metal grille, pull forward on the right hand side so that the hinge pin on the back of the grille will be released from the slot in the side of the casing.

GB

2.2 - Wall cabinet fixing

a - Predrilled wall cabinet: fix the hood onto the wall cabinet base panel using the four screws 4.2 x 45 mm (supplied with the fixing kit).

It is not necessary to open the metal grille.

b - No predrilled wall cabinet:

b.1 - If the hood is provided with a paper fixing template, follow the instructions.
b.2 - If the hood is not provided with a paper fixing template, position the hood on the wall cabinet base panel and pilot drill the 3.5 x 16 mm screws (not supplied with the fixing kit) from the inside onto the wood.

2.3 - Wall mounting

a - Drill two ∅ 8 mm holes on the wall using the paper template, insert two rawl plugs and two 4.2 x 44,4 mm screws leaving 5 mm untightened. Open the metal grille panel, hook the hood on and fully tighten the screws.
b - If the hood is not provided with a paper fixing template, drill two 8 mm holes (see draw.), insert the plugs and screws, proceeding as directed under paragraph a.
c - For wall mounting using wallbrackets (optional), follow the instructions of the fixing template.
d - Pay attention to the safety regulation of point 1.6.

2.4 - Choice of operating mode

a - Evacuation mode

To check that the hood is set up for evacuation, open the grille panel and make sure that the conversion lever or the change-over knob on the centrifugal unit is in the DUCTING position. The charcoal filter is not required.

For ducting to the outside, the hood is supplied with a rear and top outlet. A flange spigot of 100 mm diameter (120 mm in certain models) is usually fitted on the top outlet and a blanking plug on the rear outlet. If you choose to duct the hood from the rear of the casing, you should invert the position of the flange and of the blanking plug. Pay attention to the safety regulation 1.1.

b - Internal recirculation mode

To check that the hood is set up for recycling, open the grille panel and make sure that the conversion lever or the change-over knob on the centrifugal unit is in the RECYCLING position.

The charcoal filter is to be fitted. To fit the charcoal filter, support the filter with one hand and turn the thumb screw through the centre of the charcoal filter. If the filter is of the interlocking type, turn the filter clockwise. The hood can remain connected to the outside.

2.5 - Electrical connection and working test

1 - The safety measures 1.2, 1.3, 1.4 and 1.5 of paragraph 1 are to be strictly observed.
2 - Once the electrical connection has been completed, check that the worktop illumination, motor and speeds work properly.

3 - OPERATION

3.1- Controls are located on the right hand side of the front to operate worktop illumination and select the most suitable working speed for your cooking. To increase the area of extraction, the glass visor should be pulled open. The top speed should be used when frying or cooking foods with strong odours, while a lower speed can be used for normal cooking.

To obtain the best performance from your hood, turn it on before you start cooking and leave it running for a few minutes after your cooking is over to clear the air.

3.2-Pay attention to safety regulations 1.7 and 1.8.

GB

4 - MAINTENANCE AND CLEANING

Regular maintenance and cleaning will ensure good performance and reliability, while extending the working-life of the hood. Special attention should be reserved to the grease filter and to the charcoal filter (recycling mode).

4.1 - Grease filter

This retains the solid grease particles and can be supplied in different types. It is fitted onto the reverse side of the metal grille panel.

Maintenance of the grease filter varies according to the used type.

a - Whatever type of filters used, the filter is easily removed from the grille by pushing the metal wire clips to one side and removing.
b - Thin synthetic filter (1 mm thick). It should not be washed and should be replaced every two months. If the filter is provided with a saturation indicator, replace when:

b.1 - The violet colour of the dots, which are visible through the metal grille, is spread over the whole surface of the filter.
b.2 - The red colour of the stripes, which is not visible through the metal grille when the filter is clean, becomes visible from the outside of the metal grille.

c - Foam synthetic filter (approx. 10 mm thick).

It should be washed every two months in hot water using mild detergent and should be squeezed dry, not wrung out. Replace after 5 or 6 washings.

d - Multi-layer metal filter. It should be washed once a month in hot water using mild detergent or liquid soap. It can be washed in a dish-washer. It should not be bent and should be left to drain dry.

WARNING: An excess of grease in the filter not only would affect the performance of the hood, but it is also a possible fire risk.

We strongly recommend therefore to clean and replace filters in accordance with the manufacturer instructions.

4.2 - Cleaning Metal self- supporting Grease Filters

  • The filters are washable and must be cleaned at least every 2 months of operation, or more frequently for particularly heavy usage.
  • Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
  • Wash the filters, taking care not to bend them. Allow them to dry before refitting.
  • When refitting the filters, make sure that the handle is visible on the outside.

4.3 - Charcoal filter

The charcoal filter is a chemical filter to be used only when the hood is in the recycling position. To replace the charcoal filter, open the grille and remove the thumb screw through the centre of the charcoal filter. If the filter is of the interlocking type, turn the filter anticlockwise. Replace by reversing the operation. For a good performance replace the charcoal filter on average every three months.

4.4 - Worktop illumination

If a lamp fails to function at any time, open the metal grille panel and check that the lamp is fully screwed into the holder. When changing the lamp, an identical replacement must be fitted to ensure a safe working of the hood.

4.5 - Cleaning

The metal work should be cleaned regularly, at least once a month, using mild household cleaner and polish. Never use abrasives.

For all operations from point 4.1 to point 4.4 and in particular for point 4.3, pay special attention to the safety regulation 1.9.

FR

GENERALITES

The symbol 📄 on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ZANKER

Model : KHT 6241 x

Category : Range hood