MHL-45 - Effect machine BeamZ - Free user manual and instructions
Find the device manual for free MHL-45 BeamZ in PDF.
| Product type | Effect machine (fog machine) |
| Brand | BeamZ |
| Model | MHL-45 |
| Dimensions (L x W x H) | 305 x 240 x 190 mm |
| Weight | 2.8 kg |
| Power supply | 220-240 V~, 50/60 Hz |
| Power consumption | 400 W |
| Fluid type | Water-based fluid for fog machines |
| Tank capacity | 0.5 L |
| Output flow rate | Approximately 80 m³/min |
| Heat-up time | Approximately 3 minutes |
| Main functions | Continuous fog production, manual control and wired remote control |
| Maintenance and cleaning | Rinse the tank after use, use a cleaning liquid for fog machines |
| Safety | Thermal protection against overheating, automatic shut-off in case of fluid shortage |
| Spare parts and repairability | Tank, pump, heating element, remote control available |
| General information | Indoor use, do not expose to rain or humidity |
Frequently Asked Questions - MHL-45 BeamZ
User questions about MHL-45 BeamZ
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Effect machine in PDF format for free! Find your manual MHL-45 - BeamZ and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MHL-45 by BeamZ.
USER MANUAL MHL-45 BeamZ
INSTRUCTION MANUAL
GEBRUIKSAANWIJZING
GEBRAUCHSANLEITUNG
MANUEL D'INSTRUCTIONS
ENGLISH
Congratulations to the purchase of this Beamz light effect. Please read this manual thoroughly prior to using the unit in order to benefit fully from all features.
Read the manual prior to using the unit. Follow the instructions in order not to invalidate the warranty. Take all precautions to avoid fire and/or electrical shock. Repairs must only be carried out by a qualified technician in order to avoid electrical shock. Keep the manual for future reference.
- Prior to using the unit, please ask advice from a specialist. When the unit is switched on for the first time, some smell may occur. This is normal and will disappear after a while.
- The unit contains voltage carrying parts. Therefore do NOT open the housing.
- Do not place metal objects or pour liquids into the unit This may cause electrical shock and malfunction.
- Do not place the unit near heat sources such as radiators, etc. Do not place the unit on a vibrating surface. Do not cover the ventilation holes.
- The unit is not suitable for continuous use.
- Be careful with the mains lead and do not damage it. A faulty or damaged mains lead can cause electrical shock and malfunction.
- When unplugging the unit from a mains outlet, always pull the plug, never the lead.
- Do not plug or unplug the unit with wet hands.
- If the plug and/or the mains lead are damaged, they need to be replaced by a qualified technician.
- If the unit is damaged to such an extent that internal parts are visible, do NOT plug the unit into a mains outlet and DO NOT switch the unit on. Contact your dealer. Do NOT connect the unit to a rheostat or dimmer.
- To avoid fire and shock hazard, do not expose the unit to rain and moisture.
- All repairs should be carried out by a qualified technician only.
- Connect the unit to an earthed mains outlet (220-240Vac/50Hz) protected by a 10-16A fuse.
- During a thunderstorm or if the unit will not be used for a longer period of time, unplug it from the mains. The rule is: Unplug it from the mains when not in use.
- If the unit has not been used for a longer period of time, condensation may occur. Let the unit reach room temperature before you switch it on. Never use the unit in humid rooms or outdoors.
- During operation, the housing becomes very hot. Do not touch it during operation and immediately after.
- To prevent accidents in companies, you must follow the applicable guide lines and follow the instructions.
- Secure the unit with an extra safety chain if the unit is ceiling mount. Use a truss system with clamps. Make sure nobody stands in the mounting area. Mount the effect at least 50cm away from inflammable material and leave at least 1 meter space on every side to ensure sufficient cooling.
- This unit contains high intensity LEDs. Do not look into the LED light to prevent damage to your eyes.
- Do not repeatedly switch the fixture on and off. This shortens the life time.
- Keep the unit out of the reach of children. Do not leave the unit unattended.
- Do not use cleaning sprays to clean switches. The residues of these sprays cause deposits of dust and grease. In case of malfunction, always seek advice from a specialist.
- Only operate the unit with clean hands.
- Do not force the controls.
- If the unit has fallen, always have it checked by a qualified technician before you switch the unit on again.
- Do not use chemicals to clean the unit. They damage the varnish. Only clean the unit with a dry cloth.
- Keep away from electronic equipment that may cause interference.
- Only use original spares for repairs, otherwise serious damage and/or dangerous radiation may occur.
- Switch the unit off prior to unplugging it from the mains and/or other equipment. Unplug all leads and cables prior to moving the unit.
- Make sure that the mains lead cannot be damaged when people walk on it. Check the mains lead before every use for damages and faults!
- The mains voltage is 220-240Vac/50Hz. Check if power outlet match. If you travel, make sure that the mains voltage of the country is suitable for this unit.
- Keep the original packing material so that you can transport the unit in safe conditions

This mark attracts the attention of the user to high voltages that are present inside the housing and that are of sufficient magnitude to cause a shock hazard.

This mark attracts the attention of the user to important instructions that are contained in the manual and that he should read and adhere to.

DO NOT LOOK DIRECTLY INTO THE LENS. This can damage your eyes. Persons who are subject to epileptic attacks should be aware of the effects that this light effect may have on them.
The unit has been certified CE. It is prohibited to make any changes to the unit. They would invalidate the CE certificate and their guarantee!
NOTE: To make sure that the unit will function normally, it must be used in rooms with a temperature between 5° C/41°F and 35° C/95°F.

Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local authorities or your dealer about the way to proceed. The specifications are typical. The actual values can slightly change from one unit to the other. Specifications can be changed without prior notice.
UNPACKING INSTRUCTION
CAUTION! Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damage from shipping or the package itself shows signs of mishandling. Save the package and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
POWERSUPPLY
On the label on the backside of the controller is indicated on this type of power supply must be connected. Check that the mains voltage corresponds to this, all other voltages than specified, the light effect can be irreparably damaged. The controller must also be directly connected to the mains and may be used. No dimmer or adjustable power supply.
INSTALLATION

CAUTION: Please consider the respective national norms during the installation! The installation must only be carried out by an authorized employee or dealers!

Attention:
- The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation.
- The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
• Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing. - The operator has to make sure that safety-relating and machine-technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time.
- The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled person once a year.
- The fixture should be installed in the position where persons cannot reach and where persons may walk by or be seated.

CAUTION: When installing the device, make sure there is no highly in inflammable material (decoration articles, etc.) in between a distance of min 0.5 meter.


DISPLAY

The control board offers several features: you can simple set the starting address, run the pre-program program or make a reset. The main menu is accessed by pressing the Mode/Esc-button, browse through the submenu by pressing Up or Down.
Press the Enter-button in order to select the desired menu.
You can change the selection by pressing Up or Down. Confirm every selection by pressing the Enter-button.
You can leave every mode by pressing the Mode/Esc-button. The functions provided are described in the following schedule.
| DISPLAY MENU | ||
| Mode | Description | |
| ADDR | DMX start address | A001-A512 |
| CHND | Channel Mode | 6Channels |
| 11Channels | ||
| SLND | Master / Slave | NAST |
| SL1 | ||
| SL2 | ||
| SOUN | Sound Sensitivity | 0-100 |
| AUTO | Auto Mode | NO |
| YES | ||
| STBY | Standby / Pause | NO |
| YES | ||
| PAN | Invert X-Motor | NO |
| YES | ||
| TILT | Invert Y-Motor | NO |
| YES | ||
| LED | Digital display off after 10 seconds | ON |
| OFF | ||
| DISP | Rotate Digital display | ON |
| OFF | ||
| TEST | Test function | |
| HOUR | Machine on-time | |
| RSET | Reset | |
DMX-512 CONNECTION
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first unit in a DMX chain. Always connect the output of one unit with the input of the next unit until all units are connected. If you use a controller with 5 pin DMX connection you will need to use a 5-pin to 3-pin adapter.

At the last fixture, the DMX cable has to be terminated. Solder a 120 Ohm resistor between signal (-) and signal (+) into a 3-pin XLR connector and plug this into the DMX output of the last fixture in the chain.

REPLACING THE FUSE
If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.
Procedure:

Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.
FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit's optics.
• Make sure the area below the installation place is free from unwanted persons during servicing.
• Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any deformation.
- The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is detected.
- In order to protect the fixture from overheat the cooling fans (if any) and ventilation openings should be cleaned monthly.
- The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet.
- Clean with soft cloth using normal glass cleaning fluid.
• Always dry the parts carefully.
- Clean the external optics at least every month. Clean the internal optics at least every 30/60 days.
ATTENTION: We strongly recommend internal cleaning to be carried out by qualified worker!
NEDERLANDS
REPLACEMENT DU FUSIBLE
| Channel | Function | Value | Description |
| 1 | Pan | 000-255 | Adjust Pan X-motor movement |
| 2 | Tilt | 000-255 | Adjust Tilt Y-motor movement |
| 3 | Dimmer / Strobe | 000-010 | Close |
| 011-200 | Dimmer | ||
| 201-247 | Strobe | ||
| 248-255 | Full ON | ||
| 4 | Red | 000-255 | Red color adjustment from dark to bright |
| 5 | Green | 000-255 | Green color adjustment from dark to bright |
| 6 | Blue | 000-255 | Blue color adjustment from dark to bright |
11CH Mode
| Channel | Function | Value | Description |
| 1 | Pan | 000-255 | Adjust Pan X-motor movement |
| 2 | Pan Fine | 000-255 | Adjust Pan X-motor fine movement |
| 3 | Tilt | 000-255 | Adjust Tilt Y-motor movement |
| 4 | Tilt Fine | 000-255 | Adjust Tilt Y-motor fine movement |
| 5 | Dimming | 000 | Close |
| 001-255 | Dimming adjustment from dark to bright | ||
| 6 | Red | 000 | No Red |
| 001-255 | Red color adjustment from dark to bright | ||
| 7 | Green | 000 | No Green |
| 001-255 | Green color adjustment from dark to bright | ||
| 8 | Blue | 000 | No Blue |
| 001-255 | Blue color adjustment from dark to bright | ||
| 9 | Color mix | 000-009 | No colors |
| 010-255 | 32 Mixed colors | ||
| 10 | Strobe | 000-009 | No strobe |
| 010-255 | Strobe from slow to fast | ||
| 11 | Auto mode | 000-127 | No function |
| 128-255 | Auto mode |
TECHNICAL SPECIFICATION / TECNISCHE SPECIFICATIE / TECHNISCHE DATEN / ESPECIFICACIONES TÉCNICAS / SPÉCIFICATIONS TECHNIQUE
Rated voltage : AC90-230V, 50Hz-60Hz
Rated power : 50Watt
LED : 3x 15Watt
Color : RGBW color mixture
Channel : 6 / 11 Channels
Pan movement : 540°
Tilt movement : 180°
Function : DMX, Master/Slave, sound activated
Dimensions per unit : 175 x 175 x 243mm
Weight (per unit) : 3 kg
The specifications are typical. The actual values can slightly change from one unit to the other. Specifications can be changed without prior notice.

tronios
Sound & Light
CE Declaration of Conformity
Importer: TRONIOS BV
Regulatory Requirement: EN 60598-1:2008+A11:2009
EN 60598-2-17:1989+A11:2009
EN 62493:2010
EN 62471:2008
EN 55103-1:2009+A1:2012
EN 55103-2:2009
EN 61000-3-2:2006+A2:2009
EN 61000-3-3:2013
The product meets the requirements stated in Directives 2006/95 and 2004/108/EC and conforms to the above mentioned Declarations.
Almelo,
26-05-2015
Signature :

Specifications and design are subject to change without prior notice..
www.tronios.com
Copyright © 2015 by TRONIOS the Netherlands