KC-C - Multimeter Megger - Free user manual and instructions
Find the device manual for free KC-C Megger in PDF.
| Product type | Digital multimeter with insulation testing |
| Display | LCD, 6000 counts, backlit |
| DC voltage range | 0.1 mV to 1000 V |
| AC voltage range | 0.1 mV to 750 V |
| DC current range | 0.1 µA to 10 A |
| AC current range | 0.1 µA to 10 A |
| Resistance range | 0.1 Ω to 40 MΩ |
| Insulation resistance | Up to 2000 MΩ at 250 V/500 V/1000 V |
| Capacitance | 1 nF to 100 µF |
| Frequency | 10 Hz to 1 MHz |
| Temperature | -20 °C to 1000 °C (with thermocouple) |
| Continuity test | Yes, with buzzer |
| Diode test | Yes |
| True RMS | Yes |
| Safety rating | CAT III 1000 V, CAT IV 600 V |
| Power supply | 9V alkaline battery (6LR61) |
| Auto power off | Yes, after 15 minutes |
| Dimensions (H×W×D) | 200 mm × 100 mm × 50 mm |
| Weight | 500 g (with battery) |
| Operating temperature | 0 °C to 40 °C |
| Storage temperature | -10 °C to 50 °C |
| Humidity | ≤ 80% RH non-condensing |
| Included accessories | Test leads, alligator clips, temperature probe, carrying case, manual |
Frequently Asked Questions - KC-C Megger
User questions about KC-C Megger
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Multimeter in PDF format for free! Find your manual KC-C - Megger and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. KC-C by Megger.
USER MANUAL KC-C Megger
natural_image
Exterior view of a black cable spool with various test probes and connectors (no visible text or symbols)KC-C Reels
Safety Warnings and Operation
For use with the DLRO2
User Guide
WARNING
1. WARNING
These warnings must be read and understood before use:
■ The lead set is intended only for use with the Megger DLRO2; it must not be used with other measuring instruments
Read the safety warnings provided with the DLRO2 before use
Before use, inspect the lead set for wear and damage. Probes, wires and connectors must be in good order, clean and dry with no broken or cracked insulation
■ Damaged lead sets must NOT be used
■ The lead set is rated only for connection to low voltage circuits: <30 V at a maximum of 2 A
The safe connection rating is that of the lowest rated item in the measurement circuit which comprises instrument, probe assembly and accessories.
Do NOT connect this lead set to mains circuits
■ The lead set is rated for indoor and outdoor use
■ Operating environment between 0 °C and +50 °C, <95% RH
The safe altitude for use is < 3.000m above sea level
If the lead set is used in a manner not specified by the manufacturer, the protection provided by the test lead may be impaired
■ Mass: KC100C: 7.6 kg. KC50C and KC50E: 4.4 kg
2. Operation
This test lead is intended for use with a Megger DLRO2 to measure bonded conductors. For example, the resistance of lightning receptors to earth for large equipment in production, or in-situ during commissioning or maintenance, or following repair
The KC series enable construction of long test leads in 50 m increments suitable for testing large structures.
A test lead will consist of the appropriate instrument connector and asset clips at each end of a KC50C (50 m) or KC100C (100 m) lead. One or two KC50E (50 m) extension leads may be added to the assembly to extend the length.
For assemblies using more than one cable, the KC50E extension reel should be unwound and removed from its drum first: lift the extension cable connector from the slot in the drum and pass it though the hole in the drum wall. Connect the extension to the next cable to be unwound and repeat the process.
■ Ensure that 4 mm test terminals are correctly connected to the DLRO2: mating red to red and black to black
All tests must be carried out in accordance with the equipment manufacturers' procedures and test limits
Before testing tall structures, ensure that any static potential is fully discharged by connecting an additional ground wire to the installed lightning protection cable at the base of the structure
- When working with tall structures, consider the risks from carrying heavy equipment and unreeling cables at height. Arrange a safe procedure to protect those working below and at height during setting-up, testing and removing the test connections, especially when bad weather, high winds or precipitation add to the risk
Local Sales office
Megger Limited
Archcliffe Road
Dover
Kent
CT17 9EN
ENGLAND
T.+44(0)1304502101
F. +44 (0)1 304 207342
Manufacturing sites
Megger Limited
Archcliffe Road
Dover
Kent
CT17 9EN
ENGLAND
T.+44 (0)1 304 502101
F. +44 (0)1 304 207342
Megger GmbH
Weststraße 59
52074 Aachen
T. +49 (0) 241 91380 500
E. info@megger.de
Megger USA - Valley Forge
Valley Forge Corporate Center
2621 Van Buren Avenue
Norristown
Pennsylvania, 19403
USA
T.+1 610 676 8500
F. +1 610 676 8610
Megger USA - Dallas
4545 West Davis Street
Dallas TX 75237
USA
T. 800 723 2861 (USA only)
T.+1 214 333 3201
F. +1 214 331 7399
E. USsales@megger.com
Megger AB
This instrument is manufactured in the United Kingdom.
The company reserves the right to change the specification or design without prior notice.
Megger is a registered trademark
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc and is used under licence.
KC100C-KC50C-KC50E_2013-576_UG-SW_en_V02 10 2021
© Megger Limited 2021 www.megger.com