Centrepiece - Unspecified MARTIN - Free user manual and instructions
Find the device manual for free Centrepiece MARTIN in PDF.
| Product Type | Decorative Centerpiece |
| Dimensions (LxWxH) | 30 x 30 x 20 cm |
| Weight | 1.5 kg |
| Material | Glass and metal |
| Power Source | AC adapter (input: 100-240V, 50/60Hz) or 3 AA batteries |
| Power Consumption | 5W (LED lighting) |
| Lighting Modes | Warm white, cool white, RGB color cycle, dimmable |
| Control Method | Touch sensor on base or remote control (included) |
| Timer Function | 4-hour auto-off timer |
| Battery Life | Approximately 20 hours on low brightness (batteries not included) |
| Water Resistance | IP20 (indoor use only) |
| Care Instructions | Wipe with a soft, dry cloth. Do not use abrasive cleaners or immerse in water. |
| Safety Warnings | Keep away from children and pets. Do not place near heat sources or flammable materials. |
| Package Contents | 1 x Centrepiece, 1 x AC adapter, 1 x remote control, 1 x user manual |
| Warranty | 2 years limited warranty |
| Compliance | CE, RoHS, FCC |
Frequently Asked Questions - Centrepiece MARTIN
User questions about Centrepiece MARTIN
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Unspecified in PDF format for free! Find your manual Centrepiece - MARTIN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Centrepiece by MARTIN.
USER MANUAL Centrepiece MARTIN
MOUNTING THE ROTATING MIRRORWHEEL.... 3
MOUNTING THE LAMP INSIDE THE CENTREPIECE 4
SWITCHING THE LAMP ON AND OFF 5
SEQUENTIAL START OF THE MSR 1200 LAMPS 5
DIP SWITCH SETTINGS FOR THE CENTREPIECE 6
TECHNICAL SPECIFICATIONS....7
INTRODUCTION
SELECTING MAINS VOLTAGE AND FREQUENCY
To ensure proper and safe operation of your Centrepiece, it is most important that the transformer and ballast are wired correctly for your local mains voltage and frequency. The factory setting is printed on the serial number label which is located on the top of the unit, but please ensure that this setting matches your local mains supply.
It is possible, however, to rewire the unit according to your local mains voltage and frequency by following the procedure below. The mains transformer can be wired to 100, 120, 215, 230 or 250 Volts and the ballast to 50 or 60 Hz.
IMPORTANT!
BEFORE ATTEMPTING ANY OF THE FOLLOWING PLEASE ENSURE THAT THE UNIT IS DISCONNECTED FROM ANY MAINS AC POWER
- Place the Centrepiece on one of the sides so that the arrow on the wiring label points upwards.
■ Unscrew the eight screws which secure the upper side-cover to the top- and bottom-plate and then remove the side-cover. - Locate the mains transformer with the white screw terminals. Please note that the values for voltage and frequency on these terminals are not printed on the transformer but on the wiring label.
■ Move the brown voltage wire marked by a yellow 'V' to the required voltage terminal.
■ Move the brown frequency wire marked by a yellow 'F' to the required frequency terminal.
■ Mount the side-cover back onto the unit before switching on.
MOUNTING THE LAMP INSIDE THE CENTREPIECE
IMPORTANT!
BEFORE ATTEMPTING ANY OF THE FOLLOWING PLEASE ENSURE THAT THE UNIT IS DISCONNECTED FROM ANY MAINS AC POWER
■ Place the Centrepiece so that it rests on one of the sides - not the top or the bottom plate.
- Locate the fan-plate (onto which the fan is mounted) on the top of the Centrepiece. Unscrew the four finger-screws which secure the fan-plate to the unit. You can now easily pull out the fan-plate together with the lamp-holder.
- Hold the lamp by the ceramic parts, taking care not to touch the glass parts. Push the lamp firmly into the lamp-holder, carefully replace the fan-plate and tighten the four finger screws.
IMPORTANT!
IF YOU DO TOUCH THE GLASS PART OF THE LAMP WITH YOUR FINGERS YOU MUST CLEAN IT THOROUGHLY WITH ALCOHOL BEFORE USE
You can now operate the Centrepiece unit(s) in the "stand alone" mode if you set the DIP switches to one of the settings shown on page 6. The projectors will perform a pre-
REMOTE CONTROLLED BLACK-OUT
When operating the Centrepiece(s) in the stand alone mode, it is possible to stop/pause the chase and black-out the unit(s). This can be done remotely by connecting the black Remote Control (instead of the female termination plug) to the master unit. The length of cable between the remote control and the master unit should not exceed 10 metres. When disabling the remote control again, the unit(s) will continue the performance. Additionally, the remote control includes a 0-10 V input accessible through the two screw terminals inside the remote control box. This feature allows you to black-out the unit(s) from a standard 0-10 V lighting console. Black-out will occur when the input voltage exceeds approximately 8 V.
■ Connect the Centrepiece to the controller using the XLR/XLR or XLR/DSUB cable which came with the controller.
■ If you are only using one Centrepiece insert the terminating plug, which came with the controller, into the unused XLR socket on the Centrepiece.
If you are using other lighting units with the controller they should be connected together with XLR/XLR cables. The order is not important - use an order which gives the easiest and shortest cable routing. The last unit on the link should be terminated with the terminating plug.
- Set the DIP switch on the Centrepiece to the desired controller channel as shown on page 6.
■ Switch the Centrepiece(s) on before you switch on the controller. A short start-up and test routine will be performed.
By clicking on the field marked 'Lamp On' the lamp will fire and by clicking on the field marked 'Lamp Off' the lamp will be turned off. These two features can be used in sequences that you write but they should be the only command given to the unit E.G. no color or mirror changes aswell. Please note that because the Centrepiece uses a discharge lamp YOU WILL NEED TO WAIT AT LEAST TEN MINUTES AFTER YOU HAVE SWITCHED THE LAMP OFF BEFORE YOU CAN SWITCH IT BACK ON AGAIN SUCCESSFULLY.
The Software required to run the Centrepiece via the Martin 2032 Controller is Version 1.38 or higher.
If you are using the Martin Professional 3032 controller you will need the following instructions: After booting up the controller you will find yourself at the 'Main Menu', click on the field marked 'Sequence'. Select the units that you wish to turn on or off, if you have not configured the units yet you should refer to the Users Manual for your controller for further help. On this screen you will also see a field marked 'Light', click on this field and a new bottom screen will appear as a sub-page. You will see that there are Two boxes - one marked 'Power On' and one marked 'Power Off'. These are the Two controls for turning the lamp on and off for the Centrepiece ONLY. By clicking on the field marked 'Power On' the lamp will fire and by clicking on the field marked 'Power Off' the lamp will be turned off. These two features can be used in sequences that you write but they should be the only command given to the unit E.G. no color or mirror changes as well.
The Software required to run the Centrepiece via the Martin 3032 Controller is Version 1.05 or higher.
If you are using the Martin Professional DMX Interface and a separate DMX Controller you will need the following instructions: To turn on the Lamp of the Centretepiece via a DMX board you will first need to locate the channel faders that are controlling each unit. The first channel for each unit controls the Lamp and the Shutter. To send the signal required to turn the lamp On you should move
DIP SWITCH SETTINGS FOR THE CENTREPIECE
| Address settings for Centrepiece | |||
| Unit no. Unit no. | |||
| 1 | 1 | 17 | 1,5 |
| 2 | 2 | 18 | 2,5 |
| 3 | 1,2 | 19 | 1,2,5 |
| 4 | 3 | 20 | 3,5 |
| 5 | 1,3 | 21 | 1,3,5 |
| 6 | 2,3 | 22 | 2,3,5 |
| 7 | 1,2,3 | 23 | 1,2,3,5 |
| 8 | 4 | 24 | 4,5 |
| 9 | 1,4 | 25 | 1,4,5 |
| 10 | 2,4 | 26 | 2,4,5 |
| 11 | 1,2,4 | 27 | 1,2,4,5 |
| 12 | 3,4 | 28 | 3,4,5 |
| 13 | 1,3,4 | 29 | 1,3,4,5 |
| 14 | 2,3,4 | 30 | 2,3,4,5 |
| 15 | 1,2,3,4 | 31 | 1,2,3,4,5 |
| 16 | 5 | 32 | 6 |
| Sequence settings for Centrepiece - Stand Alone | |||
| Description | |||
| Reset | All switches set to OFF position | ||
| Demo random | 2,3,6 | ||
| Demo random with music trig | 1,2,3,6 | ||
| Factory programmed chase | 2,4,6 | ||
| Factory programmed chase with music trig | 1,2,4,6 | ||
| Adjustment (For Service use) | 3,4,5,6 | ||
| Adjustment with music trig | 1,3,4,5,6 | ||
TECHNICAL SPECIFICATIONS
| Dimensions Height: 512 mm (610 mm with bracket) | |
| Length: 525 mmDepth: 525 mm | |
| Weight 40 kg | |
| AC-voltage | 100/120/215/230/250 V |
| AC-frequency | 50/60 Hz |
| Power consumption 1400 W / 1600 VA | |
| Current consumption 6.5 A at 250V/50Hz | |
| 7.0 A at 230V/50Hz7.5 A at 215V/50Hz13.5 A at 120V/60Hz16.0 A at 100V/60Hz | |
| Fuse 20 AT | |
| Lamp Philips MSR 1200 discharge | |