Product Type Battery Charger/Maintainer/Desulfator
Brand BatteryMINDer
Model 1510-OBD2
Compatibility 12V lead-acid batteries with OBDII port
Input Voltage 100-240V AC, 50/60Hz
Output Voltage 12V DC
Output Current 1.5A (trickle charge/maintenance)
Desulfation Feature Yes, automatic pulse desulfation
Maintenance Mode Yes, float/maintenance after full charge
Reverse Polarity Protection Yes
Short Circuit Protection Yes
Overcharge Protection Yes, automatic shut-off
Connector Type OBD2 (SAE J1962)
Dimensions (L x W x H) 4.5 x 3.0 x 2.0 inches (approx.)
Weight 0.5 lb (approx.)
Power Cord Length 6 ft (approx.)
LED Indicators Yes, charging status and fault
Operating Temperature -20°C to 50°C
Certifications CE, UL listed (assumed)
Warranty 5 years from manufacturer

Frequently Asked Questions - 1510-OBD2 BatteryMINDer

How to use the BatteryMINDer 1510-OBD2?
Plug the unit into a standard AC outlet and connect the OBD2 connector to your vehicle's OBDII port. The charger will automatically detect battery voltage and begin charging/maintaining. No switches needed.
Can I use it on a motorcycle battery?
Yes, as long as the battery is 12V lead-acid and the vehicle has an OBDII port. For motorcycles without OBDII, use standard alligator clips (not included).
What does the desulfation feature do?
It sends high-frequency pulses to break down sulfur crystals on battery plates, restoring capacity and extending battery life. This is automatic and occurs when sulfation is detected.
Is it safe to leave connected for months?
Yes, the BatteryMINDer is designed for long-term maintenance. Once the battery is fully charged, it switches to float mode and monitors voltage to prevent overcharging.
Does it work with AGM batteries?
Yes, it works with all 12V lead-acid batteries including AGM, Gel, and Flooded. The charger adjusts its profile automatically.
How do I know when the battery is fully charged?
The LED indicator will show solid green when the battery is fully charged. Some models also have a 'charge complete' indication. Refer to the manual for exact behavior.
What is the OBD2 connector for?
It allows direct connection to a vehicle's OBDII diagnostic port, providing power and monitoring battery voltage through the vehicle's system without opening the hood.
Can I charge a completely dead battery?
Yes, but if the battery voltage is below 2V, the charger may not detect it. In such cases, use a different charger to bring it up to a minimum voltage, then switch to the BatteryMINDer.
How long does it take to charge?
Charging time depends on battery capacity and discharge level. As a rough estimate, a 50Ah battery takes about 24 hours to full charge at 1.5A. Maintenance mode is indefinite.
What is the warranty period?
BatteryMINDer offers a 5-year limited warranty on the 1510-OBD2 model. Contact their support for details.

User questions about 1510-OBD2 BatteryMINDer

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Battery charger in PDF format for free! Find your manual 1510-OBD2 - BatteryMINDer and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 1510-OBD2 by BatteryMINDer.

USER MANUAL 1510-OBD2 BatteryMINDer

both with SmarTECHnology®

12 Volt 1500 mA Charger - Maintainer - Desulfator

Assessment Fee with Joint Efficiency & 100% Voltage Recommended Fee: The Capacitor

INCLUDES:

• Auto-Temp Compensation Sensor, installed (1500 & 1510)
- Optional Permanent Mounting Tab (1500 & 1510)
- Battery Clips (1500 Standard, Non-fused; 1510 Fully-Insulated Aircraft Grade, 15A replaceable fuse)
- Ring Terminal Assembly with 15A replaceable fuse (1510 only)

\*CAUTION:

• NOT FOR USE WITH AVIATION BATTERIES
• NOT FOR USE WITH LITHIUM TYPE BATTERIES; POTENTIAL FOR EXPLOSION MAY EXIST IF USED

READ AND SAVE THESE

BatteryMINDer® & Plus with SmarTECHnology® Model 1500 Series

TABLE of CONTENTS

REQUIRED SAFETY INSTRUCTIONS .... 3

WIRE GAUGE TABLE....3

PREPARING TO CHARGE....5

CHARGER LOCATION....5

DC CONNECTION PRECAUTIONS....6

LED INDICATION TABLE 8

START-UP OPERATING INSTRUCTIONS 9

SPECIFICATIONS 9

CHARGING STATUS....9

SPECIFICATIONS 9

CHARGING STAGES....10

ADDITIONAL FEATURES....10

VOLTAGE TABLE....10

12-V PARALLEL CONNECTION DIAGRAM 10

12-V SERIES-PARALLEL USING 6-V BATTERIES....10

6-V SERIES CONNECTION DIAGRAM 10

TROUBLESHOOTING....11

MAINTAINING MULTIPLE BATTERIES....11

MODEL CALL-OUTS....12

CHARGING CURVE 13

SAFETY & PROTECTION 14

ELECTRICAL CABLE & PHYSICAL PARAMETERS .... 14

FOR REPAIR OR REPLACEMENT....15

YOUR NOTES....15

REQUIRED IMPORTANT SAFETY INSTRUCTIONS WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON, OBSERVE THE FOLLOWING:

1. SAVE THESE INSTRUCTIONS

This manual contains important safety and operating instructions for BatteryMINDer1500 and BatteryMINDer Plus 1510.

  1. Do not expose charger to rain or snow.
  2. Use of an attachment not recommended or sold by VDC Electronics may result in a risk of fire, electric shock, or injury to persons.
  3. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when disconnecting charger.
  4. An extension cord should not be used unless absolutely necessary. Use of improper extension cord could result in a risk of fire and electric shock. If an extension cord must be used, make sure:

a) That pins on plug of extension cord are the same number, size, and shape as those of plug on charger;

b) That extension cord is properly wired and in good electrical condition; and

c) That wire size is large enough for ac ampere rating of charger as specified in Table below.

TABLE 1

Recommended minimum AWG size for extension cords for battery chargers
AC input rating, amperesaAWG size of cord
Equal to or greater thanBut less thanLength of cord, feet (m)
25(7.6)50(15.2)100(30.5)150(45.6)

BatteryMINDer® & Plus with SmarTECHnology® Model 1500 Series

  1. Do not operate charger with damaged cord or plug – replace the cord or plug immediately.
  2. Do not operate charger if it has received a sharp blow, been dropped, or otherwise damaged in any way; call VDC Electronics Tech Support Dept. 800.379.5579 x6 (ET) for advice.
  3. Do not disassemble charger; call VDC Electronics Tech Support Dept. 800.379.5579 x6 (ET) for advice when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance or cleaning.

10. WARNING - RISK OF EXPLOSIVE GASES

a) WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER.
b) To reduce risk of battery explosion, follow these instructions and those published by manufacturer of any equipment you intend to use in vicinity of battery. Review cautionary marking on these products and on engine.

11. PERSONAL PRECAUTIONS

a) Consider having someone close enough by to come to your aid when you work near a lead-acid battery.
b) Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.
c) Wear complete eye protection and clothing protection. Avoid touching eyes while working near battery.
d) If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eve. Immediately flood eve with running cold

BatteryMINDer® & Plus with SmarTECHnology® Model 1500 Series

It might spark or short-circuit battery or other electrical part that may cause explosion.

g) Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery. A lead-acid battery can produce a short-circuit current high enough to weld a ring or the like to metal, causing a severe burn.

h) Use charger for charging a LEAD-ACID battery only. It is not intended to supply power to a low voltage electrical system. Do not use battery charger for charging dry-cell batteries that are commonly used with home appliances. These batteries may burst and cause injury to persons and damage to property.

i) NEVER charge a frozen battery or a battery at a temperature above 123^ F.

12. PREPARING TO CHARGE

a) If necessary to remove battery from vehicle to charge, always remove grounded terminal from battery first. Make sure all accessories in the vehicle are off, so as not to cause an arc.

b) Be sure area around battery is well ventilated while battery is being charged.

c) Clean battery terminals. Be careful to keep corrosion from coming in contact with eyes.

d) Add distilled water in each cell until battery acid reaches level specified by battery manufacturer. Do not overfill. For a battery without removable cell caps, such as valve regulated lead acid batteries, carefully follow manufacturer's recharging instructions.

e) Study all battery manufacturer's specific precautions while charging and recommended rates of charge.

f) Determine voltage of battery by referring to car owner's manual and make sure it matches output rating of battery charger.

13. CHARGER LOCATION

BatteryMINDer® & Plus with SmarTECHnology® Model 1500 Series

specific gravity or filling battery.

d) Do not operate charger in a closed-in area or restrict ventilation in any way.
e) Do not set a battery on top of charger.

14. DC CONNECTION PRECAUTIONS

a) Connect and disconnect D.C. output clips only after removing A.C. cord from electric outlet. Never allow clips to touch each other.
b) Attach clips to battery and chassis as indicated in 15(e), 15(f), and 16(b) through 16(d).

15. FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE. A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION.

TO REDUCE RISK OF A SPARK NEAR BATTERY:

a) Position ac and D.C. cords to reduce risk of damage by hood, door, or moving engine part.
b) Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to persons.
c) Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually has larger diameter than NEGATIVE (NEG, N,−) post.
d) Determine which post of battery is grounded (connected) to the chassis. If negative post is grounded to chassis (as in most vehicles), see (e). If positive post is grounded to the chassis, see (f).

e) For negative-grounded vehicle, connect POSITIVE (RED) clip from battery charger to POSITIVE (POS, P, +) ungrounded post of battery. Connect NEGATIVE (BLACK) clip to vehicle chassis or engine block away from battery. Do not connect clip to carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gage metal part of the frame or engine block.

f) For positive-grounded vehicle, connect NEGATIVE (BLACK) clip from battery charger to NEGATIVE (NEG. N. -) unarounded post of

BatteryMINDer® & Plus with SmarTECHnology® Model 1500 Series

g) When disconnecting charger, turn switches to off, disconnect AC cord, remove clip from vehicle chassis, and then remove clip from battery terminal.

h) See operating instructions for length of charge information.

  1. FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE. A SPARK NEAR THE BATTERY MAY CAUSE BATTERY EXPLOSION.

TO REDUCE RISK OF A SPARK NEAR BATTERY:

a) Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually has a larger diameter than NEGATIVE (NEG, N, -) post.

b) Attach at least a 24-inch-long 18-gauge (AWG) insulated battery cable to NEGATIVE (NEG, N, -) battery post.
c) Connect POSITIVE (RED) charger clip to POSITIVE (POS, P, +) post of battery.

d) Position yourself and free end of cable as far away from battery as possible – then connect NEGATIVE (BLACK) charger clip to free end of cable.

e) Do not face battery when making final connection.
f) When disconnecting charger, always do so in reverse sequence of connecting procedure and break first connection while as far away from battery as practical.

g) A marine (boat) battery must be removed and charged on shore. To charge it on board requires equipment specially designed for marine use.

BatteryMINDER® & Plus with SmarTECHnology® Model 1500 Series
BatteryMINDER® Plus with SmarTECHNology® 12V Charger - Maintainer Automatic Full-Time Desulfator POWER POLARY REFERENCE DESULATING LOW BATTERY CHARGING MAINTERING TABLE 2 Applies to 1500 & 1510 models

LED INDICATIONSPOWER DESULFATION CHARGING
FAULT LOW BATTERY MAINTAINING
LED ColorGREEN / REDBLUE / YELLOWGREEN
1AC Power connected, Battery disconnectedON OFFOFF
2AC Power connected, battery disconnected >10 sec., charger in sleep modeFLASH OFFOFF
3AC Power connected, battery initial condition detected for 3 sec., initial battery < 10.5VON ONOFF
4AC Power connected, battery initial condition detected for 3 sec., initial battery >10.5VON OFFOFF
5AC Power connected, soft start charging, bulk charging and absorption chargingONFLASHFLASH
6Sulfation check modeON OFFFLASH
7Maintenance charging if battery voltage < 12.5V at sulfation check modeON ONON
8Maintenance charging if battery voltage >12.5V at sulfation check modeONFLASHON

START-UP OPERATING INSTRUCTIONS

  1. Place the positive (RED) connection on the positive battery terminal.
  2. Place the negative (BLACK) connection on the negative battery terminal.
  3. Plug in the BatteryMINDer.
  4. Charging will be GREEN (flashing) (see item #5 in Table 2.) Reverse leads if you do not see this.

TABLE 3
BatteryMINDer 1500 & BatteryMINDer Plus 1510 CHARGING STATUS

Power 100 - 240 VAC Power Connected
Battery ConditionFlashing: Battery ConnectedCorrectlySolid: In Maintenance(Charge Complete)

SPECIFICATIONS

BatteryMINDer 1500 & Plus 15101.5A @ 12VDC
INPUT100-240 VAC • 50/60 Hz • 0.4A
MAINTENANCE CURRENT0 - 1.5A
SIZE (mm)100 L x 65 W x 30 H
WEIGHT1.0 lbs.
TEMPERATURE COMPENSATION-20°C/-4°F to 50°C/122°F

CHARGING STAGES

  • SoftStart Mode: when battery voltage is below 10.5 volts due to deep discharge UNIT WILL ATTEMPT TO RECOVER IT. If successful unit will automatically switch to full power Constant Current mode. If if cannot, due to faulty shorted cell(s) it will shut down and indicate such. Battery MUST be REPLACED for both SAFETY as well as performance reasons.
  • Constant Current: This stage recharges battery to 85% of its present capacity before automatically switching to Absorption stage.
  • Absorption: completes the full charge before unit switches to Maintenance (aka Float) mode
  • Maintenance (aka Float): keeps battery at full charge while continually desulfating it, ensuring full capacity for the longest possible life.

ADDITIONAL FEATURES

  • Desulfation is the removal of sulfate build-up from your battery's plates. It occurs at all times the unit is connected.
  • Short Circuit, Spark and Reverse Polarity Protection prevent the unit from having any output unless it is properly connected to your battery.
  • Ambient Temperature Sensor (ATS-1), comes already installed on the Temperature Sensor input connector. Do not detach.
  • Temperature Protection shuts down the unit if operating temperature is exceeded.

TABLE 4

VOLTAGE TABLE

MV: Minimum Voltage of a battery the unit will accept.
CV: Charge Voltage to move from Constant Current stage into Maintenance
stage.
M: Voltage during the Maintenance stage.

Model Battery Types MV CVM
1500 & 151012V Lead-Acid3.0V14.4V13.4V

All readings must be taken at 77°F (25°C)

BatteryMINDer® & Plus with SmarTECHnology® Model 1500 Series

TROUBLESHOOTING

VDC Electronics Technical Support: (800) 379-5579 x6

- Unit does not have an output unless connected to a battery. In order to test the output using a meter, connect the meter to your battery. When you connect the unit, you will see the voltage rise.

- If the unit is not in maintenance after 72 hours (solid GREEN), check to make sure your battery meets the minimum voltage of 3.0 volts. Unit will not operate if battery is below the minimum voltage of 3.0 volts. If there is a load on your battery, disconnect it and charge again. If the problem persists, your battery may be shorted or too badly sulfated.

Visit our learning center at BatteryMINDers.com for additional battery information.

MAINTAINING MULTIPLE BATTERIES

Batteries should be charged individually. To properly maintain multiple batteries they should all be the same type (gel, flooded or AGM) and condition. It is OK to mix deep cycle and starter. Charge each battery individually before connecting together. Never connect batteries at different states of charge. The charged battery will rapidly transfer energy to the discharged battery possibly causing catastrophic failure. Once the batteries are charged, use 18 gauge or greater wire to connect the batteries or for greatest safety protection and ease of use, consider Investing in the BatteryMINDER Y-Connector Model 210AY with SmarTECHnology*.

See diagram on the Page 13 for the most common multiple battery configuration.

You must connect multiple batteries of the same voltage, wire them in parallel (BatteryMINDER positive to positive A to positive B, BatteryMINDER negative to negative A to negative B). If connecting 2 batteries of half your unit's voltage (example: 6V batteries on a 12V unit), wire them in series (BatteryMINDER positive to positive A, negative A to positive B, negative B to BatteryMINDER negative). When wired in series they act as one large system at the combined voltage (example: 6V+ 6V = 12V). You can connect these systems in a series parallel configuration in order to charge or maintain 4 or batteries in groups of 2.

BatteryMINDer® & Plus with SmarTECHnology® Model 1500 Series

6A 1 2 3 4 5 6B 7 8

FEATURES
1LED Indicators
2A.C. Input plug
3ATS-1 Ambient Temperature Sensor
4Temperature Sensor input connector
5Output cord with quick connect plug
6AStandard Battery Clip cord set with quick connector(Shown connected to output cord) (Model 1500)

BatteryMINDer 1510-OBD2 - MAINTAINING MULTIPLE BATTERIES - 2

flowchart
graph LR
    A["Full time desulphation"] --> B["Battery voltage"]
    B --> C["Off Start 0.3GA (hours timer)"]
    C --> D["Bulk Charging (1.5A) (20 hours time limited)"]
    D --> E["Charging current"]
    E --> F["Absorption Charging (14.4V @25°C) (5 hours timer limited)"]
    F --> G["Sulphated Check (10 minutes)"]
    G --> H["Final Charging (13.4V @25°C)"]
    H --> I["Time"]
    I --> J["Full time desulphation"]

Safety & Protection

Safety standards:Complies with the requirements of the Standard(s) for Battery Chargers (UL-1236) and is identified with the ETL Listed Mark
EMC standard: FCC part15
Input-Output insulation test:1240Vac 60Hz5mAac, no breakdown
Cooling: By natural cooling

Electrical Cable & Physical Parameters

Input socket UL 2 PIN wall mount
Output 110 feet 18AWG X2 105°C with quick connector + 2 feet 18AWG X2 with battery clamp; 2 feet 18AWG X2 with ring terminal (for 1510)
Plastic enclosure dimension100 (L) x 65 (W) x 30 (H) mm
3.34 (L) x 2.56 (W) x 1.18 (H) in.
Operating temperature -10 to 40°C 14 to 104°F
Storage temperature-25 to 85°C-13 to 185°F
Operating humidity range0 to 90% RH
Weight <1 lb.

COMMON MULTIPLE BATTERY CONFIGURATIONS

TO CHARGER + 12V + - TO CHARGER - TO CHARGER + 6V 6V TO CHARGER - TO CHARGER + 6V + - 6V + - TO CHARGER -

BatteryMINDer® & Plus with SmarTECHnology® Model 1500 Series

FOR REPAIR OR REPLACEMENT

All returns must be authorized by VDC Electronics.

In the event that you believe your product may be defective, you MUST speak to a VDC Electronics technician at 1-800-379-5579 x6 (ET) before proceeding further.

NOTES

MODEL BatteryMINDER □1500 or □Plus 1510

SERIAL NUMBER

PLACE OF PURCHASE

DATE OF BUDOUSS

ALL returns must be authorized by VDC Electronics after speaking to a VDC Electronics technician at 800-379-5579 x6 (ET). Please see our "Repair or Replacement" section of this manual for additional information.

BatteryMINDER One-Year 100% Unconditional Money-Back GUARANTEE

This BatteryMINDER product is guaranteed to perform as claimed or WE will refund your full purchase price, including all taxes, shipping or handling cost applicable to the purchase.

Unit must be returned freight prepaid together with Proof of Purchase directly to VDC Electronics, Inc., NOT TO THE DEALER FROM WHICH IT WAS PURCHASED.

BatteryMINDER 1500 Five-Year Limited WARRANTY

VDC Electronics warrants this product for FIVE years from date of purchase at retail against defective material or workmanship and will be repaired or replaced at no charge. We make no warranty other than this limited warranty and expressly exclude any implied warranty including any warranty for consequential damages. This limited warranty is not transferable.

BatteryMINDER Plus 1510 TEN-Year Limited WARRANTY

VDC Electronics, Inc. warrants this product for TEN years from date of purchase at retail against defective material or workmanship and will be replaced with a new product equivalent or the Option to Upgrade at a discounted price. We make no warranty other than this limited warranty and expressly exclude any implied warranty including any warranty for consequential damages. This limited warranty is not transferable.

Unit must be returned freight prepaid together with Proof of Purchase directly to VDC Electronics, Inc., NOT TO THE DEALER FROM WHICH IT WAS PURCHASED.

IMPORTANT NOTICE

BatteryMINDer® Warranty Registration Reminder

Online Registration:

http://batteryminders.com/warranty_reg.php

Please register your unit online within 10 days of purchase. Due to the ever-changing technology associated with this BatteryMINDER® unit, we may be

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : BatteryMINDer

Model : 1510-OBD2

Category : Battery charger