USER MANUAL EHR 14.1 SK Eibenstock

natural_image Black EIBENSTOCK electric shaver with visible brand logo and handle (no text or symbols on body)

EHR 14.1 SK

Wichtige Hinweise

natural_image Symbol of a trash bin crossed with no text or numbers, representing waste sorting or disposal (no text present)

Nur für EU-Länder

text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Lothar Lässig

General Manager

10.08.2022

text_image Handwritten signature or scribble on white background

Frank Markert

Head of Engineering

Important Instructions

Important instructions and warning notices are allegorated on the machine by means of symbols:

Eibenstock EHR 14.1 SK - Important Instructions - 1

text_image Three black-and-white warning symbols: a person reading, a warning triangle with an exclamation mark, and a person wearing glasses.

Before you start working, read the operating instructions of the machine.

Work concentrated and carefully. Keep your work-place clean and avoid dangerous situations.

In order to protect the user, take precautions.

During work you should wear goggles, ear protectors, dust mask, protective gloves and sturdy work clothes.

Eibenstock EHR 14.1 SK - Important Instructions - 2

natural_image Three circular icons showing a person wearing headphones, a face with sunglasses, and a hand gesture (no text or symbols)

wear ear protectors

wear goggles

wear protective gloves

Technical Data

Stirrer EHR 14.1 SK

Rated voltage:230 V ~110 V ~
Rated power input:960 W900 W
Rated current:4,4 A8,8 A
Frequency:50 / 60 Hz
No Load Speed:500 rpm
Load Speed:0 – 390 rpm
Max. basket diameter:120 mm
Thread connection:M 14
Protection class:II
Degree of protection:IP 20
Net weight:about. 2,9 kg
Order number:07753000

Interference suppression: EN 55014 and EN 61000

Special Accessory:

ArticleOrder No.
Round Stirring Rod RG 12031124000
Helicon Ribbon Stirring Rod WG 12031224000
Disc Stirring Rod SG 12031524000
Mortar Stirring Rod MG 12031324000
... with M 14 thread connection

Supply

Stirrer with stirring rod and operating instructions in a set cardboard box.

Application for Intended Purpose

The Stirrer EHR 14.1 SK is designed for use in mixing paint, glue, tile cement and other media in batches up to about 30 kg.

The diameter of the used stirring rods should not exceed 120 mm.

Safety Instructions

Eibenstock EHR 14.1 SK - Safety Instructions - 1

Safe work with the machine is only possible, if you read these operating instructions completely and strictly follow the instructions contained herein.

In addition, the general safety instructions in the enclosed brochure have to be observed. Take part in a practical introduction before the first use. Save all warnings and instructions for future reference.

Eibenstock EHR 14.1 SK - Safety Instructions - 2

If the connection cable is getting damaged or cut during the work, don't touch it, but instantly pull the plug out of the socket. Never use the machine with damaged connection cable.

Eibenstock EHR 14.1 SK - Safety Instructions - 3

The machine must neither be wet, nor be used in humid ambient conditions.

  • Do not use the tool for mixing materials either in danger of explosion or easily inflammable.
  • Do not mix food.
  • Do not carry the tool at its cable.
  • Always check the tool, cable and plug before use. Have damages only repaired by specialists. Only insert the plug into the socket when the tool switch is OFF.
    ■ Modifications of the tool are prohibited.
  • When the machine runs outside, always use a protection switch (30 mA max.) against fault current.
  • The machine should only run under supervision of somebody.
  • Pull the plug and switch the machine off if it is not under supervision, e.g. in case of setting up and stripping down the machine, in case of voltage drop or when fixing or mounting an accessory.
  • Switch the machine off if it stops for whatever reason. This way, you avoid that it starts suddenly and not under supervision.
  • Always lead the cable to the back, away from the machine.
  • Do not use the machine if a part of the housing is damaged or in case of damages on the switch, the connection cable or plug.
    ■ Power tools have to be inspected by a specialist in regular intervals.
  • Keep the handles dry, clean and free of oil and grease.
  • Do not touch rotating parts.
  • Be careful with long hair. Only work with close-fitting clothes.
  • Persons under 16 years of age are not allowed to use the machine.
  • When working with this machine wear ear protectors, goggles and protective gloves.

Eibenstock EHR 14.1 SK - Safety Instructions - 4

Eibenstock EHR 14.1 SK - Safety Instructions - 5

Eibenstock EHR 14.1 SK - Safety Instructions - 6

During use, always hold the machine with both hands and maintain a safe standing position. Pay attention to the reaction moment of the machine.

For further safety instructions, please refer to the enclosure.

Electrical Connection

Before starting the machine check the correspondence between voltage and frequency according to the data mentioned on the identification plate. Voltage differences from +6% and -10% are allowed. The mixer is made in protection class II. Only use extension cables with a sufficient cross-section. A cross-section which is too small could lead to an excessive power loss and to an overheating of motor and cable.

Tool Change

Eibenstock EHR 14.1 SK - Tool Change - 1

Eibenstock EHR 14.1 SK - Tool Change - 2

Eibenstock EHR 14.1 SK - Tool Change - 3

Attention!

Before any work on the tool, disconnect the plug from the mains! When inserting the tool, you could catch your hands. For this reason, always wear protective gloves for changing the tool.

The work spindle of the machine has a M 14 - internal thread. Keep threads and front surface clean.

Please hold up with a jaw wrench 22 to remove the stirring rod.

Tool Protection

Wrong handling can cause damages on the tool. Therefore, please always observe the following instructions:

Only use stirring rods with M14 - internal thread which are recommended by the producer.

Please consider the max. basket diameters.

Do not allow blocking of the tool.

Only use original accessories made by EIBENSTOCK.

Switching on and off

To start the power tool, first press the lock-off button, then press the on/off switch and keep it pressed.

Note: For safety reasons, the on/off switch cannot be locked; it must remain pressed during the entire operation.

To switch off the power tool, release the on/off switch.

The stirrer is equipped with an electronic switch. With this switch the speed can be regulated according to the pressure on the button. Only use the electronic switch when you want to start or stop the machine in order to

avoid material splashing around. Permanent use with reduced speed can cause an overload because the motor then gets less cooling air and therefore the machine will be overheated much faster.

Care and Maintenance

Eibenstock EHR 14.1 SK - Care and Maintenance - 1

Before the beginning of maintenance or repair works you have to disconnect the plug from the mains.

Repairs may be executed only be appropriately qualified and experienced personnel. After every repair the machine has to be inspected by an electric specialist. Due to its design, the machine needs a minimum of care and maintenance. However, the following points always have to be observed:

■ Always keep the power tool and the ventilation slots clean.
■ During work, please pay attention that no particles get inside the machine.
- In case of failure, a repair has to be carried out by an authorised service workshop.

Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare parts.

EIBENSTOCK's application service team will gladly answer questions concerning our products and their accessories.

Environmental Protection

Eibenstock EHR 14.1 SK - Environmental Protection - 1

Raw Material Recycling instead of Waste Disposal

In order to avoid damages on transportation, the tool has to be delivered in solid packaging. Packaging as well as unit and accessories are made of recyclable materials and can be disposed accordingly.

The tool's plastics components are marked according to their material, which makes it possible to remove environmentally friendly and differentiated because of available collection facilities.

Only for EU countries

Eibenstock EHR 14.1 SK - Only for EU countries - 1

natural_image Symbol of a trash bin crossed with no text or labels

Do not dispose of electric tools together with household waste material!

In observance of the European Directive 2012/19/EU on waste electrical and electronic equipment and its implementation in accordance with national law, electric tools that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility.

The indication of noise emission is measured according to EN 62841. The level of acoustic pressure on the work place could exceed 85 dB (A); in this case protection measures must be taken.

Eibenstock EHR 14.1 SK - Only for EU countries - 2

Wear ear protectors!

The typical hand-arm vibration is below 2.5 m/s ^4 .

Measured values determined according to EN 62841.

The declared vibration emission level represents the main applications of the tool. However, if the tool is used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase the exposure level over the total working period

An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period.

Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep the hands warm, organisation of work patterns.

Warranty

According to the general supply conditions for business dealings, suppliers have to provide to companies a warranty period of 12 months for redhibitory defects. (to be documented by invoice or delivery note)

Damage due to natural wear, overstressing or improper handling are excluded from this warranty.

Damages due to material defects or production faults shall be eliminated free of charge by either repair or replacement.

Complaints will be accepted only if the tool was returned in non-dismantled condition to the manufacturer or an authorized Eibenstock service centre.

EU - Declaration of Conformity

We declare under our sole responsibility that the product described under "Technical Data" is in conformity with the following standards or standardization documents:

EN 62841-1, EN 62841-2-10, EN 55014-1, EN 55014-2

EN IEC 61000-3-2, EN 61000-3-3, EN IEC 63000

according to the provisions of the directives 2011/65/EU, 2014/30/EU, 2006/42/EG

Technical file (2006/42/EC) at:

text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Lothar Lässig

General Manager

10.08.2022

Eibenstock EHR 14.1 SK - EU - Declaration of Conformity - 1

text_image Handwritten signature or scribble on a wavy line, possibly from a document or form

Frank Markert

Head of Engineering

GB - Declaration of Conformity

We declare as the manufacturer under our sole responsibility that the product described under “Technical Data” fulfills all the relevant provisions of the following regulations S.I. 2008/1597 (as amended), S.I. 2017/1206 (as amended), S.I. 2012/3032 (as amended) and that the following designated standards have been used:

BS EN 62841-1, BS EN 62841-2-10, BS EN 55014-1, BS EN 55014-2

BS EN 61000-3-2, BS EN 61000-3-3, BS EN IEC 63000

Technical file (S.I. 2008/1597) at:

text_image Handwritten signature or scribble with three curved lines and a period, possibly indicating a signature or annotation.

Lothar Lässig

General Manager

10.08.2022

Subject to change without notice.

Eibenstock EHR 14.1 SK - GB - Declaration of Conformity - 1

text_image Handwritten signature or scribble on white background

Frank Markert

Head of Engineering

natural_image Symbol of a trash bin with crossed lines indicating no waste or discharge (no text or labels)
text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Lothar Lässig

General Manager

10.08.2022

text_image Handwritten signature or scribble on a wavy line, possibly from a document or form

Frank Markert

Head of Engineering

natural_image Symbol of a trash bin crossed with no text or numbers, representing waste sorting or disposal (no text present)
text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Lothar Lässig

General Manager

Eibenstock EHR 14.1 SK - GB - Declaration of Conformity - 2

text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Frank Markert

Head of Engineering

10.08.2022

text_image Three black-and-white warning symbols: a person reading, a warning triangle with an exclamation mark, and a person wearing glasses.
natural_image Symbol of a trash bin crossed with no text or numbers, representing waste sorting or recycling (no text present)
text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Lothar Lässig

General Manager

Eibenstock EHR 14.1 SK - GB - Declaration of Conformity - 3

text_image Handwritten signature or scribble on white background

Frank Markert

Head of Engineering

10.08.2022

text_image Three black-and-white warning symbols: a person reading, a warning triangle with an exclamation mark, and a person wearing glasses.
natural_image Four circular icons showing different human and safety symbols: headphones, glasses, hand gesture, and mask (no text or labels)

Use auriculares protectores

natural_image Close-up of a mechanical component with two directional arrows labeled 1 and 2 (no text or symbols beyond labels)
natural_image Symbol of a trash bin crossed with no text or labels
text_image Handwritten signature or scribble on a wavy line, possibly from a document or form

Frank Markert

Head of Engineering

text_image Three black-and-white warning symbols: a person reading, a warning triangle with an exclamation mark, and a person wearing sunglasses.
natural_image Three circular icons showing head, face, and hand symbols (no text or labels)

Anvend høreværn

natural_image Symbol of a trash bin with crossed lines indicating no waste or discharge (no text or labels)
text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Lothar Lässig

General Manager

10.08.2022

text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Frank Markert

Head of Engineering

Důležité pokyny

natural_image Symbol of a trash bin crossed with diagonal lines, representing waste sorting or disposal (no text or labels)

Jenom pro země EU

text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Lothar Lässig

General Manager

10.08.2022

Změny vyhrazeny.

Eibenstock EHR 14.1 SK - Jenom pro země EU - 1

text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Frank Markert

Head of Engineering

Önemli Talimatlar

natural_image Symbol of a trash bin crossed with no text or labels
text_image Handwritten signature or scribble on white background, possibly a signature or artistic mark

Lothar Lässig

General Manager

10.08.2022

text_image Handwritten signature or scribble on white background

Frank Markert

Head of Engineering

Ihr Fachhändler Your distributor Votre marchand spécialisé Il vostro revenditore specializzato Uw distributeur Su distribuidor especializado Din forhandler Váš prodejce Sizin bayi

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Eibenstock

Model : EHR 14.1 SK

Category : Paint mixer