Product type Infrared ear thermometer
Brand Beurer
Model FT 55
Dimensions 34 x 145 x 28 mm
Weight 57 g (battery included)
Power supply 1 lithium battery 3V CR2032
Battery life Approximately 3000 measurements
Main functions Ear temperature measurement, surface temperature measurement, ambient temperature measurement
Memory 9 positions with date and time
Fever alarm Optical (red LED) and acoustic from 37.5 °C
Measuring range (ear) 34 °C to 42.2 °C (93.2 °F to 108.0 °F)
Measuring range (surface) -22 °C to 80 °C (-7.6 °F to 176 °F)
Accuracy (ear) ± 0.2 °C from 35.5 °C to 42 °C, otherwise ± 0.3 °C
Measurement time 1 to 2 seconds
Display LED with fever indicator (green/red)
Temperature units °C or °F (switchable)
Care and cleaning Clean the sensor tip with a soft cloth moistened with disinfectant or alcohol after each use. Do not immerse in water.
Safety Non-waterproof thermometer. Keep out of reach of children under 6 months. Do not use in case of ear inflammation or injury.
Spare parts and repairability Repairs must be carried out by the authorized after-sales service. Battery replaceable by the user.
General information Compliant with directives 93/42/EC and standards EN 12470-5, EN60601-1-2. For domestic use only.

Frequently Asked Questions - FT 55 BEURER

How to use the FT 55 ear thermometer?
Turn on the device by pressing the power button. Gently pull the earlobe back and upward, carefully insert the sensor tip into the ear canal and press the SCAN button for 1 second. A long beep indicates the end of the measurement. The temperature is displayed with a green (normal) or red (fever) LED.
What is the difference between measurement modes?
The 'ear thermometer' mode (Ⓙ icon) measures body temperature in the ear. The SCAN mode (⚙ icon) allows measuring surface or liquid temperature. The standby mode (clock icon) displays the ambient temperature.
How to switch between °C and °F?
Turn off the thermometer or put it in standby. Hold down the SCAN button and simultaneously press the power button until the unit changes. The values in memory will be converted.
What to do if the screen displays an error message?
Common errors include: measurement during self-test (wait until the ear symbol stops flashing), ambient temperature out of range (10-40 °C), or low battery (replace it). If the error persists, remove the battery for 1 minute and reinsert it.
How to clean the thermometer?
After each use, clean the sensor tip with a soft cloth or cotton swab moistened with disinfectant, alcohol, or lukewarm water. For the device, use a slightly damp cloth with mild soap. Never immerse the device in water.
When to replace the battery?
Replace the battery (type CR2032) when the battery symbol flashes. Use a pointed object to open the compartment, insert the new battery with the + pole facing up, and close.
Is the thermometer accurate for children?
Yes, from 6 months. In infants under 6 months, the ear canal is too narrow for reliable measurement. For older children, clinical accuracy is 0.22 °C.
Can liquids be measured with this thermometer?
Yes, in SCAN mode. Hold the sensor tip near the liquid (without immersing) or directly on the surface. The measuring range is -22 °C to 80 °C.
How to set the date and time?
Turn on the thermometer, then press the ⚙ button for 5 seconds. Use the SCAN button to set successively the 12/24h mode, hour, minutes, year, month, and day. Confirm each step with the ⚙ button.
What to do in case of doubt about fever?
The thermometer emits an alarm (red LED and beep) for any temperature > 37.5 °C. However, it is recommended to consult a doctor for clinical interpretation, especially in the presence of other symptoms.

User questions about FT 55 BEURER

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermometer in PDF format for free! Find your manual FT 55 - BEURER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FT 55 by BEURER.

USER MANUAL FT 55 BEURER

beurer ____medical

Close-up of a medical or cosmetic device with a digital display showing '36.8' and '20.15', no readable text beyond branding.

FT 55

D 3 in 1 Ohrthermometer Gebrauchsanleitung
GB 3 in 1 Ear Thermometer Operating instructions
F 3 en 1 Thermomètre auriculaire Mode d'emploi
E 3 en 1 Termómetro para el oído Instrucciones para el uso
Termometro per orecchio 3 in 1 Instruzioni per l'uso
TR 3'ü 1 Kulak termometresi Kullanma Talimatı
RUS Ушной термометр «3 в 1» Инструкция по применению
PL Termometr douszny 3 w 1 Instrukcja obsługi

BEURER FT 55 - FT 55 - 1

BEURER GmbH • Söflinger Str. 218 • 89077 Ulm (Germany)

Tel.: +49 (0)731 / 39 89-144 • Fax: +49 (0)731 / 39 89-255

BEURER FT 55 - FT 55 - 2

We are happy that you have decided on a product from our range. Our name stands for high-quality and exhaustively tested products from the areas of warmth, gentle therapy, blood pressure, body temperature, weight, massage and air. Please read these instructions for use carefully and follow the directions.

Yours faithfully,

The Beurer Team

1. Important notes

  • This device is a sensitive electronic device. Please treat it carefully and do not expose it to any mechanical impacts.
  • Do not expose the thermometer to direct sunlight.
  • The FT55 thermometer is only designed for the measuring area on the human body stated in the instructions for use.
  • The device should be in the room in which the measurement is made for at least 30 minutes before use.
  • The thermometer is NOT waterproof. For this reason, direct contact with water or other liquids should be avoided.
    – Clean the measuring tip after each use with a soft cloth moistened with disinfectant.
  • Check before each use that the lens is intact. If it is damaged, please contact the dealer or service address.
  • The thermometer was constructed for practical use but cannot replace a visit to the doctor.
    – This device is not intended for commercial or clinical use.
  • The device is intended only for the purpose given in these directions for use.
    – Repairs must be carried out only by authorised service agents. Otherwise the guarantee becomes void.
  • There are people in whom different measurement results are obtained in the left and right ear. In order to record temperature changes, always measure in the same ear in the same person.
    – If you have been lying on one ear for some time, the temperature is slightly raised. Wait a little while or measure in the other ear.
  • As ear wax can affect the measurement, you should clean the ear before measuring if necessary.
    – The ear thermometer may be used by children only under adult supervision. Measurement is usually possible over the age of 6 months.

In infants under 6 months, the ear passage is still very narrow so that the temperature of the eardrum can often not be recorded and the measurement result displayed is too low.

  • The measurement must not be taken in an ear affected by inflammatory diseases (e.g. discharging pus or secretion), after possible ear injuries (e.g. eardrum damage) or in the healing period after operative procedures. In all of these cases, please talk to your doctor.
    – This device complies with EU Directive 93/42/EC.
  • This device complies with standard EN 12470-5 Medical Thermometers, Requirements for Infrared Ear Thermometers (with maximum device).
  • This unit is in line with European Standard EN60601-1-2 and is subject to particular precautions with regard to electromagnetic compatibility (EMC). Please note that portable and mobile HF communication systems may interfere with this unit. For more details, please contact customer service at the address indicated.
    – If you have further questions about using our devices, please contact your dealer or Customer Service.
  • Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.

2. What you should know about using this thermometer

Before using a forehead thermometer, an ear thermometer or a conventional rod thermometer, the following should be noted: The different thermometers listed above are suitable for measuring body temperature in different parts of the body: forehead thermometer: measurement only on the forehead, ear thermometer: measurement only in the ear, rod thermometer: rectal (in the back passage), axillary (under the arm) or oral measurement (in the mouth).

The temperature varies depending on the part of the body where the measurement is taken. The difference in healthy persons between different parts of the body can be between 0.2–1 °C. The approximate normal temperature ranges are as follows:

  • forehead temperature – measured with a forehead thermometer: 35.8 °C to 37.6 °C.
  • Ear temperature, measured with an ear thermometer: 36.0 °C to 37.8 °C.
  • Rectal temperature, measured with a conventional thermometer: 36.3 °C to 37.8 °C.
  • orally measured temperature – measured with a conventional thermometer: 36.0 °C to 37.4 °C.

Beurer-Tip:

Temperatures measured with different thermometers cannot be compared with one another.

You should therefore tell your doctor or bear in mind if you are diagnosing yourself what thermometer you used to take your temperature and in what part of the body.

The temperature of a healthy person is also influenced by the following factors:

  • The person's individual metabolism.
  • Age (body temperature is higher in babies and small children and falls with increasing age. Greater temperature fluctuations occur faster and more often in children).
  • Clothing.
    • The outside temperature.
  • The time of day (body temperature is lower in the morning and increases during the day towards evening).
  • Preceding physical and, to a lesser extent, mental activity.

Beurer-Tip:

Taking the temperature gives a measurement that provides information about a person's current body temperature. If you are uncertain about interpreting the results or if the result is abnormal (e.g. fever), you should consult your doctor. This also applies in the case of slight temperature changes if there are other symptoms of illness such as agitation, severe sweating, flushed skin, fast pulse rate, tendency to collapse etc.

3. Description of device

Front side
Protective cap red LED (fever alarm) "SCAN" button On/Off/Memory button SCAN green LED LCD-Display Battery compartment unlocking Sensor tip Battery compartment cover

Rear side

4. Functions

This infrared thermometer measures the

- Temperature in the human ear,

– surface temperature of objects and liquids,

- ambient temperatures.

The thermometer also offers additional functionalities:

  • 9 memory locations for simple plotting of changes in temper ature,
    – date and time, also with all stored temperatures measured,
  • Optical and acoustic fever alarm at temperatures over 37.5 °C,
  • switchable to °C and °F.

5. Operation

This thermometer is designed for use in the ear (ear passage / eardrum) usually for persons aged over 6 months. In children under 6 months, the ear passage is still very narrow so that the temperature of the eardrum can often not be recorded and and the measurement result displayed is too low.

Before taking the temperature, remove the protective cap and ensure that the sensor tip and also the ear passage are clean. If there are signs of acute inflammation (discharge of pus or secretion, pain), in the case of injuries or directly after operations on the ear, the non-affected side should be chosen. Otherwise, the measurement result can be incorrect.

Use of the thermometer in different persons can be inappropriate in certain acute infectious diseases because of the possible spread of germs despite cleaning and disinfection. Discuss this with your doctor in the individual case.

It must only be used without disposable covers.

There is a battery in it already so that it can be used immediately when operated for the first time.

Switch on the thermometer with the “⏻” button. After a brief self-test and two short beeps, the thermo meter is ready to measure the temperature in your ear.

5.1 Setting time and date

With the thermometer switched on, hold the “💡” button depressed for 5 seconds. As soon as the “SET” symbol appears in the display, you can use the “SCAN” button to set in turn the 12 or 24 hour mode, hour, minute, year, month and day ( ,24' appears in the display for the 24-hour mode). Confirm the values set in each case with the “💡” button.

BEURER FT 55 - Setting time and date - 1

5.2 Batteries

The Type 3V CR2032 battery is already fitted and depending on usage has a life of around 3000 measurements. When the battery gets weak, the battery warning symbol appears ☐. It is still possible to measure the temperature. Battery must be replaced. When the battery symbol fl ashes ☐, the battery must be exchanged by sliding the battery compartment cover off to the rear.

Switch off the device, press the battery compartment lock with a sharp object and slide the battery compartment cover downwards at the same time.

Insert a new battery of the same type with the positive pole at the top. Close the battery compartment cover again.

Used batteries should not go into domestic refuse. You are legally obliged to dispose of the batteries correctly. Dispose of them through your electrical dealer or local recycling centre.

Note: you will find these symbols on batteries containing toxic substances: Pb = battery contains lead, Cd = battery contains cadmium, Hg = battery contains mercury. The battery in this device does not contain toxic substances.

Close-up of a handheld electronic device with a circular component and a cable (no visible text or symbols)

BEURER FT 55 - Batteries - 2

6. During use

Always ensure that the sensor is clean and undamaged. Switch on the thermometer with the "☐" button.

6.1 Measuring in the ear

After a brief self-test and two short beeps, the thermometer is ready to measure the temperature in your ear. The infrared thermometer is in „ear thermometer“ mode. This is indicated by the symbol ⚙.

As the ear passage is slightly curved, you have to pull the ear slightly up and backwards before inserting the sensor tip. This is particularly important so that the sensor tip can be pointed directly at the eardrum. Insert the sensor tip carefully and press the "SCAN" button for 1 sec.

The end of the measuring time is signalled with a long beep. Release the "SCAN" button. You can now read off the temperature measured. The LED is also illuminated according to the test result: a green LED indicates that body temperature is within the normal range, but a red LED lights up with measured values over 37.5 °C, i.e. it is a fever alarm.

The thermometer signals with two short beeps and the cessation of fl ashing of the ear symbol “?” that the unit is ready to continue measurement.

BEURER FT 55 - Measuring in the ear - 1

BEURER FT 55 - Measuring in the ear - 2

6.2 Saving the temperatures measured

The temperature last measured, i.e. only the last temperature of a series measured, is saved automatically as soon as the thermometer is switched off. There are 9 memory locations available for this.

You can call up the last temperature measured with the “💡” button. The date and time are also shown. The LED does not support any requests for stored measured values. If you continue to hold down the “💡”, you will enter a special measuring mode, in which the thermometer will not make a correct measurement. In this event, allow the thermometer to switch off automatically after about 1 minute and then switch it on again.

6.3 Surface temperatures

When you want to measure surface temperatures with this infrared thermometer, you must change to the "SCAN" mode. With the thermometer switched on (Ear thermometer mode) keep the "☐" button depressed and at the same time press the "SCAN" button. This mode is indicated with the 🔊 symbol. If you keep the "SCAN" button depressed, the surface temperature measured is continuously displayed. You can apply the sensor tip directly to the surface to be measured or measure at close range (do not immerse in liquids).

Note that the displayed temperature is the measured and not the adapted ear surface temperature. It is not the same as the ear temperature.

6.4 Ambient temperature

After the measurement, the thermometer automatically switches to standby mode after about 1 minute, but only if the time has been set. This mode is identified by the 🔔 symbol and the ambient temperature is shown continuously. If you want to use the thermometer to measure the ambient temperature, it should be positioned so that the measurement is not influenced by solar radiation or other influences such as cold draughts from air-conditioning systems. In addition to the ambient temperature, which is updated once every minute, the date and time are displayed alternately.

6.5 Changing the temperature unit

You can display the temperature in degrees Celsius (°C) or degrees Fahrenheit (°F). With the thermo meter switched off or in standby mode, select the unit by holding down the "SCAN" button and at the same time pressing the "☐" button. Keep the two buttons depressed until the temperature unit changes. All stored temperatures are displayed in the new temperature unit.

  1. Trouble shooting
ErrormessageProblem Solution
BEURER FT 55 - Changing the temperature unit - 1Autotest in progress, device not yeast ready for. Wait until the ear symbol stops flashing.
BEURER FT 55 - Changing the temperature unit - 2Large fluctuation in ambient temperature. Store the device for at least 30 minutes in the room where the measurement will be taken.
BEURER FT 55 - Changing the temperature unit - 3Ambient temperature below 10 °C or above 40 ( <50 °F, >104 °F).The ambient temperature must be between 10 °C and 40 °C (50 °F, 104 °F).
BEURER FT 55 - Changing the temperature unit - 4Device no longer functioning correctly. Take out battery for approx. 1 minute and insert again. If the error message is repeated, consult your dealer or customer service.
BEURER FT 55 - Changing the temperature unit - 5(1) Ear thermometer mode: the temperature measured is higher than 42.2 °C (108 °F).(2) SCAN mode: the temper ature measured is higher than 80 °C (176 °F).Operate the thermometer only between the specified tempera ture ranges. If necessary, clean the sensor tip. In the event of a repeated error message, contact your dealer or customer service.
BEURER FT 55 - Changing the temperature unit - 6(1) Ear thermometer mode: the temperature measured is lower than 34 °C (93.2 °F).(2) SCAN mode: the temperature measured is lower than -22 °C (-7.6 °F).Operate the thermometer only between the specified temperature ranges. If necessary, clean the sensor tip. In the event of a repeated error message, contact your dealer or customer service.
BEURER FT 55 - Changing the temperature unit - 7Autotest not successful. Insert new battery.

8. Cleaning, storage, disposal

Clean the sensor tip after every use. Use a clean cloth or cotton bud that can be moistened with disinfectant, alcohol or warm water.

To clean the entire device, use a soft cloth slightly moistened with a mild soapy solution. Water must never get into the device. If water gets into the device, remove the battery immediately. Only use the device again when it is completely dry. Do not use any harsh cleaning agents.

Never immerse the device in water.

Always store the thermometer with the cap on in order to protect the sensor.

The device must not be stored or used at too high or low a temperature or humidity (see 9. technical data), in sunlight, in association with an electrical current or in dusty locations. Otherwise, inaccuracies can occur.

If prolonged storage is intended, you should remove the battery.

Please dispose of the device in accordance with the directive 2002/96/EG – WEEE (Waste Electrical and Electronic Equipment). If you have any queries, please refer to the local authorities responsible for waste disposal.

BEURER FT 55 - Cleaning, storage, disposal - 1

9. Technical data

Note: When the device is used outside the specifications, perfect functioning cannot be guaranteed. We reserve the right to make technical changes to improve and develop the product.

Model FT 55
Measurement range Ear thermometermode: 34 °C - 42.2 °C (93.2 °F - 108.0 °F)SCAN mode: -22 °C - 80 °C (-7.6 °F - 176 °F)
Laboratory measurement precisionEar thermometer mode: ±0.2 °C (±0.4 °F) from 35.5 °C - 42 °C (95.9 °F - 107.6 °F), ±0.3 °C (±0.5 °F) < 35.5 °C >42 °C (<95.9 °F->107.6 °F)SCAN-Modus: ±0.3 °C (±0.5 °F) from 22 °C to 42.2 °C (71.6 °F to 108 °F)±2 °C (±4 °F) with >42.2 °C and <22 °C (>108 °F <71.6 °F)
Clinical repeat precision 0.22 °C (children, 1 to 5 years), 0.21 °C (adults)
Measurement duration 1 to 2 seconds
Interval between 2 measurements At least 5 seconds
Measurement units °Celsius (°C) or °Fahrenheit (°F)
Ambient operating conditions 10 °C to 40 °C (50 °F – 104 °F) with a relative humidity of 95 % (non-condensing)
Storage conditions -20 °C to 50 °C (-4 °F – 122 °F) with a relative humidity of up to 85 % (noncondensing)
Dimensions 34 x 145 x 28 mm
Weight 57 g including battery
Battery 1 lithium battery (type 3V CR-2032)
Memory For 9 measurements
Explanation of symbolsDevice classification type BF Please read the instructions for use ⚠️