Hydro IP Tester - Testeur American DJ - Free user manual and instructions
Find the device manual for free Hydro IP Tester American DJ in PDF.
User questions about Hydro IP Tester American DJ
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Testeur in PDF format for free! Find your manual Hydro IP Tester - American DJ and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Hydro IP Tester by American DJ.
USER MANUAL Hydro IP Tester American DJ
natural_image
Black plastic hard-shell case with visible internal features and a small logo on the front face (no text or symbols on the casing itself)User Manual
©2023 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their respective companies.
ADJ Products, LLC and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.

DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this document may be available online.
Please check www.adj.com for the latest revision/update of this manual before beginning installation and/or programming.
| Date | Document Version | Software Version | DMX Channels Notes |
| 05/08/2023 1 | .0 1.02 Not Applicable Initial Release | ||
Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the environment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
TABLE OF CONTENTS
General Information 4
Limited Warranty (USA Only) 5
Safety Precautions 6
Overview 7
Recommended Tools 8
Connections 9
Operation 11
Functions 12
Testing Example: ADJ Encore LP18IP 18
PC Software - Installation 20
PC Software - Operation 23
Updating Tester Software from PC Software 31
Case Dimensions | Optional Accessories 33
GENERAL INFORMATION
Introduction: Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this device. These instructions contain important safety and use information.
Unpacking: Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all accessories necessary to install and operate the device have arrived intact. In the event that damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this device to your dealer without first contacting customer support. Please do not discard the shipping carton in the trash. Please recycle whenever possible.
Box Contents:
• (1) 3-5 ft Coiled Air Hose/Quick Connect Fitting
• (1) M12 Treaded Brass Nozzle/Push-to-Connect Fitting
• (1) M12x1.5 Hex-Socket Cap-Head A4-70 Stainless Steel Bolt/Washer
• (1) 5 ft Power Cable
• (1) 6 ft USB Cable
• (1) 4GM (min) Micro SD Card
Customer Support: Contact ADJ Service for any product related service and support needs. Also visit forums.adj.com with questions, comments or suggestions.
Parts: To purchase parts online visit:
http://parts.adj.com (US)
http://www.adjparts.eu (EU)
ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST
Voice: 800-322-6337 | Fax: 323-582-2941 | support@adj.com
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 60 | Fax: +31 45 546 85 96 | support@americandj.eu

IMPORTANT NOTICE!
THIS DEVICE MUST ONLY BE USED BY AN AUTHORIZED ELATION TRAINED SERVICE TECHNICIAN. DO NOT ATTEMPT TO USE THIS DEVICE UNLESS YOU HAVE BEEN FULLY TRAINED ON ITS USAGE. ANY DAMAGE OR REPAIRS TO THIS DEVICE OR ANY ELATION AND/OR NON-ELATION LIGHTING FIXTURES CONNECTED TO THIS DEVICE RESULTING FROM IMPROPER USE, INCORRECT PRESSURE/VACUUM SETTINGS, AND/OR THE DISREGARD OF THE SAFETY AND OPERATION GUIDELINES IN THIS USER MANUAL VOIDS THE ELATION WARRANTY AND IS NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS, AND MAY ALSO VOID THE WARRANTY FOR ANY NON-ELATION LIGHTING FIXTURES.
CONSULT WITH YOUR RESPECTIVE LIGHTING MANUFACTURER BEFORE USING THIS DEVICE ON NON-ELATION BRAND FIXTURES! DEVICE SETTINGS CONTAINED IN THIS MANUAL DO NOT APPLY TO NON-ELATION BRAND FIXTURES AND MAY DAMAGE YOUR FIXTURE. PLEASE CONTACT ELATION SERVICE FOR FURTHER DETAILS.
LIMITED WARRANTY (USA ONLY)
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner's responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, you must obtain a Return Authorization number (RA#) before sending the product back—please contact ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All shipping charges must be prepaid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall incur no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because it was not properly maintained as set forth in the product instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include maintenance, cleaning, or periodic check-up. During the period specified above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear identifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty period set forth above. And all warranties, whether expressed or implied, including warranties of merchantability or fitness, are limited in duration to the warranty period set forth above. The consumer's and/or dealer's sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall ADJ Product, LLC be liable for any loss and/or damage, direct and/or consequential arising out of the use of, and/or inability to use this product.
G. This warranty is the only written warranty applicable to ADJ Products, LLC products, and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
MANUFACTURER'S LIMITED WARRANTY PERIODS:
- Non-LED Lighting Products = 1-Year (365 Days) (Including Special Effect Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands, Power/Data Distribution, etc. excluding LED and lamps)
- Laser Products = 1-Year (365 Days) (excluding laser diodes which have a 6-Month Limited Warranty)
- LED Products = 2-Year (730 Days) (excluding batteries which have a 180 Day Limited Warranty)
- NOTE: 2-Year (730 Days) Limited Warranty ONLY applies to product purchased within the United States. StarTec Series = 1-Year (365 Days) (excluding batteries which have a 180 Day Limited Warranty)
• ADJ DMX Controllers = 2 Year (730 Days)
• American Audio Products = 1 Year (365 Days)
SAFETY PRECAUTIONS
This device is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. ADJ Products, LLC is not responsible for injury and/or damages resulting from the misuse of this device due to the disregard of the information printed in this manual. Only the original included parts and/or accessories for this device should be used. Any modifications to the device and/or included accessories will void the original manufacturer's warranty and increase the risk of damage and/or personal injury.

PROTECTION CLASS 1 - DEVICE MUST BE PROPERLY GROUNDED.

THIS DEVICE MUST ONLY BE USED BY AN AUTHORIZED ELATION TRAINED SERVICE TECHNICIAN. DO NOT ATTEMPT TO USE THIS DEVICE UNLESS YOU HAVE BEEN TRAINED ON ITS USAGE. ANY DAMAGE OR REPAIRS TO THIS DEVICE OR ANY ELATION AND/OR NON-ELATION LIGHTING FIXTURES CONNECTED TO THIS DEVICE RESULTING FROM IMPROPER USE, INCORRECT PRESSURE/VACUUM SETTINGS, AND/OR THE DISREGARD OF THE SAFETY AND OPERATION GUIDELINES IN THIS USER MANUAL VOIDS THE ELATION WARRANTY AND IS NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS, AND MAY ALSO VOID THE WARRANTY FOR ANY NON-ELATION LIGHTING FIXTURES.

DO NOT PLUG DEVICE INTO A DIMMER PACK! KEEP FLAMMABLE MATERIALS AWAY FROM DEVICE.

DRY LOCATIONS USE ONLY! DO NOT EXPOSE DEVICE TO RAIN, MOISTURE, AND/OR SEVERE ENVIRONMENTS! DO NOT SPILL WATER AND/OR LIQUIDS ONTO OR INTO THE DEVICE!

IP FIXTURE MUST BE POWERED OFF AND PROPERLY COOLED BEFORE TESTING. PLEASE REFER TO THE IP FIXTURE USER MANUAL FOR PROPER COOLING TIMES.

ENSURE NO DUST, WATER, OR DEBRIS ENTERS THE IP FIXTURE WHEN REMOVING THE AIR RELIEF VALVES! CAREFULLY INSPECT THE AREA AROUND THE AIR RELIEF VALVE OPENINGS BEFORE REPLACING THE AIR RELIEF VALVE AFTER TESTING IS COMPLETE.
- DO NOT connect an external compressor to the device.
- AVOID brute force handling when transporting or operating.
- DO NOT expose any part of the device to open flame or smoke. Keep device away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
- DO NOT use device in extreme and/or severe environments.
- DO NOT operate device if power cord is frayed, crimped, damaged and/or if any of the power cord connectors are damaged and do not insert into the device securely with ease. NEVER force a power cord connector into device. If the power cord or any of its connectors are damaged, replace it immediately with a new connector of the same power rating.
- CAUTION: Device should be operated by qualified and trained professionals ONLY.
- Read user manual carefully to ensure normal operation and lifespan of the device.
- ONLY use the original packaging materials and/or case to transport the Hydro IP Tester in for service.
OVERVIEW

text_image
Pressure/Vacuum Hose Connector Air In/Out Vent Display Screen Micro SD Card Slot USB Port Power Switch Pressure/Vacuum Hose Storage Compartment Pressure / Vacuum In Future AIR ROUT Micro SD IO USB ON/OFF POWER IN Port Mode Button Up Button Right Button Enter Button Down Button Left Button Hydro IP TesterRECOMMENDED TOOLS
Tools pictured below are required to remove and/or replace the pressure relief valves used on most IP fixtures. These are not included with the Hydro IP Tester but can be purchased at any local hardware store.

text_image
M12x1.5 Hex Socket Cap Head A4-70 Stainless Steel Bolt/Washer (included) 6mm Hex Wrench (not included) Socket Wrench (not included) 17mm Socket (not included)CONNECTIONS

natural_image
Close-up of a hand inserting a metallic valve into a black plastic-wrapped device labeled 'Hydro IP Tester' (no readable text beyond label)- Connect the air hose quick-connect fitting to the Hydro IP Tester.

natural_image
Four electronic device modules with labeled buttons and a red circle highlighting a central component (no readable text or symbols beyond branding)- Remove the main pressure relief valve from the fixture.

natural_image
Close-up of a black automotive roof grille with a circular vent and screw base (no text or symbols visible)
natural_image
Close-up of a black mechanical component with a central hole and textured surface (no visible text or symbols)
natural_image
Close-up of hands adjusting a small metallic component on a black surface (no visible text or symbols)
natural_image
Close-up of a black car's front grille with a circular headlight and metallic screw base (no visible text or symbols)- If the fixture has a second pressure relief valve, remove and replace it with an M12x1.5 Hex Socket Cap Head A4-70 Stainless Steel Bolt/Washer (included), and tighten using a 6mm Hex Wrench. NOTE: Make sure the bolt has its O-ring for a proper seal.
CONNECTIONS

natural_image
Close-up of a black electronic device with a hand inserting a cable to its socket (no visible text or symbols)-
Carefully insert the threaded end of brass nozzle into the fixture air relief valve hole and twist it until it is finger tight and slightly compresses the rubber O-ring seal.
-
Connect power cable to the Hydro IP Tester and switch the device on.
NOTE: If a leak is suspected at the nozzle or nylon bolt, check the following items:
- Confirm brass nozzle is properly inserted and secure, and apply an additional 14 -turn if needed.
- Confirm air hose is fully inserted approximately 1-inch (2.5cm). Remove and reinsert if needed.
- Confirm the nylon bolt is properly installed and secure, and apply an additional 14 -turn if needed. Retest fixture again to verify the nozzle or nylon bolt leak no longer exists.

WARNING: DO NOT OVER TIGHTEN BRASS NOZZLE OR NYLON BOLT!
OPERATION
CONTROL PANEL
This device features a keyed control panel, as pictured below. Key functions are as follows:
- UP: Scroll to the previous option.
• DOWN: Scroll to the next option. - LEFT: Scroll to option on the left, or decrease the value of selected field.
- RIGHT: Scroll to option on the right, or increase the value of the selected field.
- ENTER: Confirm or select.
• MODE: Return or cancel.

text_image
MODE UP LEFT ENTER RIGHT DOWNAlternately, this device features touch screen functionality. Touch screen functions are as follows:
- Tap icon or item on screen to select.
- Swipe left to return to the previous menu screen.
- Swipe up/down to vertical scroll.
- Touch screen also includes ability to drag sliders to adjust values.
FUNCTIONS

CONSULT WITH YOUR RESPECTIVE LIGHTING MANUFACTURER BEFORE USING THIS DEVICE ON NON-ELATION BRAND FIXTURES! DEVICE SETTINGS CONTAINED IN THIS MANUAL DO NOT APPLY TO NON-ELATION BRAND FIXTURES AND MAY DAMAGE YOUR FIXTURE. PLEASE CONTACT ELATION SERVICE FOR FURTHER DETAILS.
TEST
![]() | 1. Select “Test” from the main menu. |
![]() | 2. Select the desired test mode. Available options include Auto, Pressure, or Vacuum. Note: Auto will run one of the test settings configured in the Personality menu. |
![]() | 3. If the Pressure or Vacuum test modes are selected, a Manual Test Config menu will open, which will required the user to set the desired test parameters and press the checkmark button to confirm. Note: This menu does not appear if the Auto test mode is selected. |
| CONTINUED ON NEXT PAGE | |
FUNCTIONS
TEST

text_image
Manual Test: Pressure Target Value: 50.0Kpa Min Value: 40.0Kpa Hold Time: 30s Run Time: 0s- Press Enter or touch the Play button on the touch screen to begin the test.

text_image
Fixture 1 Test: Pressure Target Value: 40.3Kpa Min Value: 31.0Kpa Hold Time: 24s Run Time: 15s- Press Enter or touch the Stop button on the touch screen to stop the test. The upper bar indicates the test pressure, and will be colored green if the pressure is within the acceptable range, or red if the pressure is outside the acceptable range. The blue-colored lower bar indicates the hold time.

text_image
Test Report Pressure Vacuum Result Pass Pass Target 40.3 Kpa -37.3 Kpa Min 31.0 Kpa -27.0 Kpa- The device will generate a test report. Results in green are passing results, while results in red are failed results. Please make sure to scroll up and down to make sure you view the entire test report.
FUNCTIONS
PERSONALITY
![]() | 1. Select “Personality” from the main menu. |
![]() | 2. Select the checkbox next to the pressure units that you would like to use, then select the “Fixture Config” button. |
![]() | 3. The “Edit Projects” menu will open. In this menu, you can select existing projects to modify, remove existing projects by selecting a project or projects and pressing the “-” button, or add new projects by pressing the “+” button. Note: The device can accommodate up to 20 projects at a time. |
![]() |
FUNCTIONS
PERSONALITY
CONTINUED ON NEXT PAGE

text_image
Project Name: Up to 16 characters Pressure Target: 0.0Kpa Min: 0.0Kpa Hold Time: 0s
text_image
Project Name: Fixture Pressure Target: 0.0Kpa 1# qw e r t y u i o p ABC a s d f g h j k l - z x c v b n m . . :- If adding a new project or editing an existing project, type in the project name, then use the sliders to configure the desired target value, minimum value, and hold time. Press the Save button to confirm.
FUNCTIONS
UPDATE
![]() | 1. Select “Update” from the main menu. |
![]() | 2. Use the keypad to type in the password, then press the Checkmark button to confirm. Note: The default pass-word is “038”. |
![]() | 3. Select the desired update file from the displayed list. Note: Selecting an incompatible file will result in an error message. |
FUNCTIONS
INFORMATION

text_image
Test Personality Update Information- Select "Information" from the main menu.

text_image
Information ● Manufacture: ADJ ● Software Version: V1.02- Information about the unit manufacturer and software version will now be displayed on the screen. Swipe left or press the Back button to return to the main menu.
TESTING EXAMPLE: ADJ ENCORE LP18IP

natural_image
Black optical equipment with a circular light source and a rectangular case (no visible text or symbols)The following sequence of instructions demonstrates a typical IP fixture test. However, specific testing instructions will vary for each IP fixture.
The ADJ Encore LP28IP, which is used for this testing example, does NOT have a secondary pressure relief valve. Therefore, for testing, it is only required to remove a single valve for this fixture, but other fixture models may require the removal of a secondary valve.
Always review the manual for your IP fixture for specific information about whether your unit features a secondary valve, and for instructions on accessing the pressure relief valves.

natural_image
Close-up of a black handheld device with a red valve inserted into a cylindrical component, labeled 'Hydro IP Tester' (no readable text beyond label)- Connect the air hose quick-connect fitting to the Hydro IP Tester.

natural_image
Four electronic device modules with labeled buttons and a red circle highlighting a central component (no readable text or symbols beyond branding)- Remove the main pressure relief valve from the fixture.
TESTING EXAMPLE: ADJ ENCORE LP18IP

natural_image
Close-up of a black electronic device with a hand inserting a cable to its side, showing internal components and a red arrow indicating a specific part (no text or symbols visible)-
Carefully insert the threaded end of brass nozzle into the fixture air relief valve hole and twist it until it is finger tight and slightly compresses the rubber O-ring seal. Make sure not to over tighten the brass nozzle or nylon bolt!
-
Connect power cable to the Hydro IP Tester and switch the device on.
NOTE: If a leak is suspected at the nozzle or nylon bolt, check the following items:
- Confirm brass nozzle is properly inserted and secure, and apply an additional 14 -turn if needed.
- Confirm air hose is fully inserted approximately 1-inch (2.5cm). Remove and reinsert if needed.
-
Confirm the nylon bolt is properly installed and secure, and apply an additional 14 -turn if needed. Retest fixture again to verify the nozzle or nylon bolt leak no longer exists.
-
Use the directional buttons on the control panel to select "Personality," then press ENTER.
-
Scroll to "Fixtures," then press ENTER.
-
Use the LEFT and RIGHT arrow buttons to scroll through a list of available fixture models, and press ENTER when the desired model is shown on the screen. The fixture name and test parameters will be displayed on the screen. Press ENTER again to confirm and load your selection.
-
Press MODE to return to the main menu, then use the directional buttons on the control panel to select "Test". Press ENTER.
-
Select "Auto" and press ENTER to bring up a screen showing the fixture model and the option to start the test.
-
Scroll to "Start Test" and press ENTER. This brings you to a menu to input the serial number of the fixture. Use the LEFT and RIGHT arrows to highlight each digit of the serial number, and the UP and DOWN arrows to change the value of the selected digit. Press ENTER to start the test. Alternately, you may bypass the serial number input by simply pressing ENTER.
PC SOFTWARE - INSTALLATION
Compatible with Windows 7, 8, 8,1 and 10. Minimum of 52MB of free disk space is required.
Download and install IPTester 1.0.2 setup.
Step 1: Select Destination Location (requires at least 52MB of free disk space).

text_image
Setup - IPTester Select Destination Location Where should IPTester be installed? Setup will install IPTester into the following folder. To continue, click Next. If you would like to select a different folder, click Browse. C:\Program Files (x86)\IPTester Browse... At least 52.0 MB of free disk space is required. Next > CancelStep 2: Select Start Menu Folder. To select a different folder location, click 'Browse...', and then click 'Next >' to continue.

text_image
Setup - IPTester Select Start Menu Folder Where should Setup place the program's shortcuts? Setup will create the program's shortcuts in the following Start Menu folder. To continue, click Next. If you would like to select a different folder, click Browse. IPTester Browse... Don't create a Start Menu folder < Back Next > CancelPC SOFTWARE - INSTALLATION
Step 3: Select Additional Tasks, then select 'Create a desktop shortcut' and click 'Next>'.

text_image
Setup - IPTester Select Additional Tasks Which additional tasks should be performed? Select the additional tasks you would like Setup to perform while installing IPTester, then click Next. Additional shortcuts: ✓ Create a desktop shortcutStep 4: Under the 'Ready to install' section, click 'Install'.

text_image
Setup - IPTester Ready to Install Setup is now ready to begin installing IPTester on your computer. Click Install to continue with the installation, or click Back if you want to review or change any settings. Destination location: C:\Program Files (x86)\IPTester Start Menu folder: IPTester Additional tasks: Additional shortcuts: Create a desktop shortcut < Back Install CancelPC SOFTWARE - INSTALLATION
Step 5: As the program finishes installing, a dialogue window will prompt you to launch the program. Select Run SETUP.EXE, then select Launch IPTester if desired. Click Finish.

text_image
Setup - IPTester Completing the IPTester Setup Wizard Setup has finished installing IPTester on your computer. The application may be launched by selecting the installed shortcuts. Click Finish to exit Setup. ✓ Launch IPTester ✓ Run SETUP.EXE Finish
Click desktop shortcut with icon shown above to launch IPTester software.
PC SOFTWARE - OPERATION
MAIN SOFTWARE INTERFACE

text_image
IP Tester 1.8.2 Setup project Open a project blank Operation Management Update Template Filter: (Input fixture name and press "Enter" key) SZP HDX IP MP HDX IP TP HDX IP 7PZ IP CUEPX 16IP CW Profile HP IP Dyna G HO ExDMX DynaCove Ex HO DynaGrace Ex HO Linear One Ex LOOKING FOR ANY LEAK Profile IP Probus Beam Probus Hybrid Sipar LV 72IP Volt WIFLY EXR HDXS IP Wify EXR QAS IP WW Profile HP IP Blank Import photo Fixture Name: less than 16 characters Unit: kPa Pressure target: 0.00 kPa Pressure min. limit(0, 60) 0.00 kPa Hold Time: 1 sec) Vacuum target: 0.00 kPa Vacuum min. limit(-60, 0) 0.00 kPa Hold Time: 1 sec) Save Cancel UploadStep 1: Click the 'blank' area to upload a new fixture and enter the following new data:
- Import Photo: Upload fixture photo in png. or jpg. format
• Fixture Name: Enter fixture name
• Unit: Choose between kPa and psi. - Pressure Target: Enter maximum pressure value.
- Pressure Min.: Enter minimum pressure value.
- Hold Time: Enter number of seconds for Pressure test.
• Vacuum Target: Enter maximum vacuum value.
• Vacuum Min.: Enter minimum vacuum value. - Hold Time: Enter number of seconds for Vacuum test.
PC SOFTWARE - OPERATION
MAIN SOFTWARE INTERFACE

text_image
x86/IP Tester/templates:Encore LP18IP.png Import photo Fixture Name: Encore LP18IP Unit: psi Pressure target: limit(0, 8.7) 7.98 psi Pressure min. limit(0, 8.7) 6.53 psi Hold Time: 10 (sec) Vacuum target: limit(-8.7, 0) -7.98 psi Vacuum min. limit(-8.7, 0) -6.53 psi Hold Time: 10 (sec) Save Upload Cancel
text_image
Delete Encore LP18IP blank- Save: Saves entered data and lists the fixture.
- Upload: Upload the data to Hydro IP Tester. CONFIG OK displays if upload is successfully. Ensure Hydro IP Tester is connected to PC successfully before clicking Upload.
- Delete: Right click to delete the fixture data you want.
PC SOFTWARE - OPERATION
MAIN SOFTWARE INTERFACE
Step 2: Select fixture for testing, then click "Setup Project". The following image will be displayed:

line
| Time(sec) | Pressure(kPa) | | --------- | ------------- | | 0 | 20.0 | | 10 | 20.0 | | 20 | 20.0 | | 30 | 20.0 | | 40 | 20.0 | | 50 | 20.0 | | 60 | 20.0 | | 70 | 20.0 | | 80 | 20.0 | | 90 | 20.0 | | 100 | 20.0 | | 110 | 20.0 | | 120 | 20.0 | | 130 | 20.0 | | 140 | 20.0 | | 150 | 20.0 | | 160 | 20.0 | | 170 | 20.0 | | 180 | 20.0 | | 190 | 20.0 | | 200 | 20.0 | | 210 | 20.0 | | 220 | 20.0 | | 230 | 20.0 | | 240 | 20.0 | | 250 | 20.0 | | 260 | 20.0 | | 270 | 20.0 | | 280 | 20.0 | | 290 | 20.0 | | 300 | 20.0 | | 310 | 20.0 | | 320 | 20.0 | | 330 | 20.0 | | 340 | 20.0 | | 350 | 20.0 | | 360 | 20.0 | | 370 | 20.0 | | 380 | 20.0 | | 390 | 20.0 | | 400 | 20.0 | | 410 | 20.0 | | 420 | 20.0 | | 430 | 20.0 | | 440 | 20.0 | | 450 | 20.0 | | 460 | 20.0 | | 470 | 20.0 | | 480 | 20.0 | | 490 | 20.0 | | 500 | 20.0 | | 510 | 20.0 | | 520 | 20.0 | | 530 | 20.0 | | 540 | 20.0 | | 550 | 20.0 | | 560 | 20.0 | | 570 | 20.0 | | 580 | 20.0 | | 590 | 20.0 | | 600 | 20.0 | | 610 | 20.0 | | 620 | 20.0 | | 630 | 20.0 | | 640 | 20.0 | | 650 | 20.0 | | 660 | 20.0 | | 670 | 20.0 | | 680 | 20.0 | | 690 | 20.0 | | 700 | 20.0 | | 710 | 20.0 | | 720 | 20.0 | | 730 | 20.0 | | 740 | 20.0 | | 750 | 20.0 | | 760 | 20.0 | | 770 | 20.0 | | 780 | 20.0 | | 790 | 20.0 | | 800 | 20.0 | | 810 | 20.0 | | 820 | 20.0 | | 830 | 20.0 | | 840 | 20.0 | | 850 | 20.0 | | 860 | 20.0 | | 870 | 20.0 | | 880 | 20.0 | | 890 | 20.0 | | 901 | 25.5 | | 911 | -35 | | 921 | -45 | | 931 | -55 | | 941 | -65 | | 951 | -75 | | 961 | -85 | | 971 | -95 | | 981 | -15 | | 991 | -35 | | Note: The actual values for 'Manual test' and 'Auto test' are not provided in the code snippet, so they are left blank in the image.
Click here to return to the main interface.
√ Manual test
□ Auto test



Manual test: Click (+) for Pressure Test, and (-) for Vacuum Test.
□ Manual test
√ Auto test


Auto test: Performs Pressure test first, then Vacuum test.
Current pressure:
Current pressure: Shows current fixture pressure.
Hold Time:
Hold time: Shows hold time for either Pressure test or Vacuum test.
PC SOFTWARE - OPERATION
MAIN SOFTWARE INTERFACE
Step 3: The following 5 test displays are samples of tests run in both Manual Test and Auto Test modes:
Sample Manual Test for Pressure - Pass

line
| Time(sec) | Pressure(psi) | | --------- | ------------- | | 0.0 | 1.5 | | 5.0 | 2.8 | | 10.0 | 2.2 | | 20.0 | 2.2 | | 30.0 | 2.2 | | 40.0 | 2.2 | | 50.0 | 2.2 | | 60.0 | 2.2 | | 70.0 | 2.2 | | 80.0 | 2.2 | | 90.0 | 2.2 |Sample Manual Test for Vacuum - Pass

line
| Time(sec) | Pressure(psi) | | --------- | ------------- | | 0.0 | -2.41818 | | 10.0 | -2.41818 | | 20.0 | -2.41818 | | 30.0 | -2.41818 | | 40.0 | -2.41818 | | 50.0 | -2.41818 | | 60.0 | -2.41818 | | 70.0 | -2.41818 | | 80.0 | -2.41818 | | 90.0 | -2.41818 |PC SOFTWARE - OPERATION
MAIN SOFTWARE INTERFACE
Sample Auto Test - Running

line
| Time(sec) | Pressure(psi) | | --------- | ------------- | | 0 | 1.0 | | 5 | 2.5 | | 10 | 2.3 | | 15 | -2.0 | | 20 | -2.0 | | 25 | -2.0 | | 30 | -2.0 | | 35 | -2.0 | | 40 | -2.0 | | 45 | -2.0 | | 50 | -2.0 | | 55 | -2.0 | | 60 | -2.0 | | 65 | -2.0 | | 70 | -2.0 | | 75 | -2.0 | | 80 | -2.0 | | 85 | -2.0 | | 90 | -2.0 |Sample Auto Test - Pass

line
| Time(sec) | Pressure(psi) | | --------- | ------------- | | 0.0 | 1.5 | | 5.0 | 2.5 | | 10.0 | 2.3 | | 15.0 | -2.0 | | 20.0 | -2.0 | | 25.0 | -2.0 | | 30.0 | -2.0 | | 35.0 | -2.0 | | 40.0 | -2.0 | | 45.0 | -2.0 | | 50.0 | -2.0 | | 55.0 | -2.0 | | 60.0 | -2.0 | | 65.0 | -2.0 | | 70.0 | -2.0 | | 75.0 | -2.0 | | 80.0 | -2.0 | | 85.0 | -2.0 | | 90.0 | -2.0 |PC SOFTWARE - OPERATION
MAIN SOFTWARE INTERFACE
Sample Auto Test - Fail

line
| Time(sec) | Pressure(ml) | | --------- | ------------ | | 0.0 | 1.5 | | 5.0 | 2.5 | | 10.0 | 2.3 | | 15.0 | -1.5 | | 20.0 | -2.0 | | 25.0 | -1.0 | | 30.0 | -0.5 |
Test fail

PC SOFTWARE - OPERATION
MAIN SOFTWARE INTERFACE
Step 4: To save test results, first select your file location and the name of your file. Then click the "Save" button. Test results can be saved in two file formats: .gmv and .xlsx (see below). When saving to .xlsx format, enter the device serial number so it will correctly display in .xlsx table.

text_image
Save Project File name: When saving to .xlsx format, enter serial number here as file name so it will correctly display in .xlsx table. Save as type: GMV File(*.gmv) GMV File(*.gmv) Excel(*.xlsx) Browse Folders Save CancelStep 5:
To check the results that you saved on .gmv:
- The test results saved in .gmv format can be opened from your computer with the IPTester PC software. Click on 'Open a project', then navigate to the location where you saved the project file from Step 4 above. Click 'Open'.
- Depending on the unit setting (psi or kpa), the Hydro IP Tester can work independently of a PC and automatically saves test results in either a .psi or .kpa format on the Micro SD card, which can then be viewed by the IPTester PC software.

text_image
IP Tester 1.0.2 Setup project Template Filter: Input fixture name and press "Enter" key Open a project Open Project IP Tester > IP Test Files > test files in gmv format Search test files in gmv format Organize ▼ New folder Name Date modified Type Size Quick access Serial Number as file name Date IPTester File 2 KB Desktop Downloads Pictures IP Tester IPTester program OneDrive This PC 3D Objects File name: Serial Number as file name GMV File(*.gmv;*.kpa) Open CancelPC SOFTWARE - OPERATION
MAIN SOFTWARE INTERFACE
Step 5 (cont'd):
To check the results that you saved in .xlsx: Test results saved in .xlsx format can be opened with Microsoft Excel. Note that when saving to an .xlsx format, you should enter the serial number of the fixture in the file name box (as highlighted by the red outline below) before saving, so that it will correctly display in the .xlsx table.

line
| Parameter | Value | | ----------------- | ----- | | Device SN# | 3.1 | | Device SN# | 2.9 | | Device SN# | 2.8 | | Device SN# | 2.7 | | Device SN# | 2.6 | | Device SN# | 2.5 | | Device SN# | 2.4 | | Device SN# | 2.3 | | Device SN# | 2.2 | | Device SN# | 2.1 | | Device SN# | 2.0 | | Device SN# | 1.9 | | Device SN# | 1.8 | | Device SN# | 1.7 | | Device SN# | 1.6 | | Device SN# | 1.5 | | Device SN# | 1.4 | | Device SN# | 1.3 | | Device SN# | 1.2 | | Device SN# | 1.1 | | Device SN# | 1.0 | | Device SN# | 0.9 | | Device SN# | 0.8 | | Device SN# | 0.7 | | Device SN# | 0.6 | | Device SN# | 0.5 | | Device SN# | 0.4 | | Device SN# | 0.3 | | Device SN# | 0.2 | | Device SN# | 0.1 | | Device SN# | 0.0 | | Device SN# | -0.1 | | Device SN# | -0.2 | | Device SN# | -0.3 | | Device SN# | -0.4 | | Device SN# | -0.5 | | Device SN# | -0.6 | | Device SN# | -0.7 | | Device SN# | -0.8 | | Device SN# | -0.9 | | Device SN# | -1.0 | | Device SN# | -1.1 | | Device SN# | -1.2 | | Device SN# | -1.3 | | Device SN# | -1.4 | | Device SN# | -1.5 | | Device SN# | -1.6 | | Device SN# | -1.7 | | Device SN# | -1.8 | | Device SN# | -1.9 | | Device SN# | -2.0 | | Device SN# | -2.1 | | Device SN# | -2.2 | | Device SN# | -2.3 | | Device SN# | -2.4 | | Device SN# | -2.5 | | Device SN# | -2.6 | | Device SN# | -2.7 | | Device SN# | -2.8 | | Device SN# | -2.9 | | Device SN# | -3.0 | | Device SN# | -3.1 | | Device SN# | -3.2 | | Device SN# | -3.3 | | Device SN# | -3.4 | | Device SN# | -3.5 | | Device SN# | -3.6 | | Device SN# | -3.7 | | Device SN# | -3.8 | | Device SN# | -3.9 | | Device SN# | -4.0 | The image is not a data table with multiple values for the chart.UPDATING TESTER SOFTWARE FROM PC SOFTWARE
Step 1: With the Hydro IP Tester connected to your computer via the USB cable and the PC software open, click "Update".

text_image
IP Tester 1.0.2 Setup project Open a project Template Filter: Input fixture name and press 'Enter' key 12P HEX IP 18P HEX IP 7P HEX IP 7PZ IP CUEPIX 16P CW Profile HP IP DynarG HO bIXMX DynarCove ExHO DynarGrace Ex HO Linear One Ex LOOKING FOR ANY LEAK Profile IP Proteus Beam Proteus Hybrid Sixpar UV 72P Volt WIFIY EXR HEXS IP WIFIY EXR Q4S IP VW Profile HP IP blank UpdateStep 2: Click "Browse" and navigate to the following location: HydroIPTester > Program > xUxx_Vxxx.gsd, then click "Ok". Note that the .gsd file name will differ depending on the update file name.

text_image
GSD Update GSD Path: Browse Update OKStep 3: Click on "xUxx_Vxxx.gsd" to select IP Hydro Tester software update, then click "Open".

text_image
File Program Files (xdb) > iTester > program Searchprogram Organize * New folder Name Cash modified Type Size 1.001_V102.gsd 15/10/2018 12:52 GSD file 52 KB OneDrive This PC 3D Objects Desktop Documents Downloads Music Pictures Videos file name: 1.001_V102.gsd IGSD file*.gsd Open CancelUPDATING TESTER SOFTWARE FROM PC SOFTWARE
Step 4: With the Hydro IP Tester software update path opened, click "Update".

text_image
GSD Update GSD Path: E:\x86\JFTester\program/1001_V102.gsd Browse Update Choose file: C:/Program Files (x86)\JFTester\program/1001_V102.gsd OKStep 5: After 'Update' is selected, the Hydro IP Tester PC Software will update the software of the-Hydro IP Tester unit, with the status of the update progress displayed in real time. When the update has been completed, the status message "Update completely!" will be shown.

text_image
GSD Update GSD Path: s (x86)/IPTester/program/1001_V102.gsd Browse Update Choose file: C:/Program Files (x86)/IPTester/program/1001_V102.gsd Cid file size: 134320 bytes File is uploading,please wait for a moment. Send count: 4198 Update completely: OKStep 6: During the update process, the Hydro IP Tester screen displays the image on the left. Once the update has been completed, it automatically resorts to the default Mode selection screen menu shown below on the right.

text_image
Software Update Online 1. Long Wait 2. Product Code Correct 3. User Code Correct 4. Software Version Correct Now Update is Pcb: 01 IC: 001 Count: 01000 Boot: U1.1.2 Data Check...
text_image
Test Personality Update InformationDISPLAY NEWLY UPDATED (CURRENT) SOFTWARE:
- Go to the Hydro IP Tester's main menu, scroll to "Info", and press the ENTER button.
- Scroll to "Software Ver" and press ENTER. The current software version will now be displayed.
- Press the MODE button to return to the main menu.
CASE DIMENSIONS
Weight: 15.4 lbs / 7 Kg

natural_image
Black plastic case with internal compartments and a 6.5-inch diameter dimension label (no text or symbols on the casing itself)
natural_image
Black plastic device with attached cable and side strap, labeled 14.25" (362mm) in dimension (no other text or symbols)
text_image
11.0" (279.4mm) 16.5" (419.1mm) 12.5" (317.5mm)
text_image
5.2" (132mm) 15.25" (387.4mm)OPTIONAL ACCESSORIES
| ORDER CODE DESCRIPTION | |
| 50501990323 3-5 ft Coiled | Air Hose/Quick Connect Fitting |
| 9900010723 M12 Threaded | d Brass Nozzle/Push-to-Connect Fitting |
| IP TESTER PLUG M12x1.5 | Hex Socket Cap Head A4-70 Stainless Steel Bolt/Washer |
| NEU007 Power Cable | |