USER MANUAL QU-KD2N-HF QUIO
I. Features & Specification
Feature:
● Multi-mode access control
● Support ISO15693 / ISO14443A (Mifare) / ISO14443B / DESFire / NTAG203
2.42 inch OLED Display
● Multi communication interface
● Provide protocol to develop.
Specification:
| Frequency | 13.56MHz |
| Interface | RS485 / Wiegand / Ethernet / Wi-Fi |
| Wiegand Wiegand (support 26/32/34/35/37/42/66 bits) | |
| RS485 baud rate | 19,200 bits/sec (4,800~460,800) |
| Ethernet | 10M/100M Ethernet Port |
| Wi-Fi 802.11 b/g/n | |
| Display 2.42 inch 128 x 64 OLED display | |
| Status Indicator | Tricolor LED(RGB) & Beeper |
| Keypad | 13 capacitive touch button |
| IR Sensor | 1 IR sensor for waving hand to access door (adjustable range 0~10cm) |
| Digital Input | Up to 3(1 DI+2 no -voltage DI share the same port with Wiegand) |
| Digital Output Up to 4 | (2 Relay output+ 2 open collector DO share the same port with Wiegand) |
| HF Protocols ISO15693 / ISO14443A / ISO14443B / DESFire / NTAG203 | |
| HF Read range | Up to 5 cm |
| ID | 0001~9999 |
| Number of Cards | 10000 |
| Capacity of Records | 100000 |
| Power Supply | 9 ~28 VDC (12 VDC) |
| Power consumption | 1W~6W |
| Operating temperature | -10°C to 60°C |
| Dimensions (mm) | 124 x 90 x 27mm |
II. Wiring Diagram

flowchart
graph LR
A["Wi-Fi"] --> B["Ethernet"]
B --> C["HUB"]
C --> D["PC"]
D --> E["Link with SY86 device"]
subgraph Ethernet
F["1"]
G["+8=28V(Red+红色)"]
H["GROUND*(Black+黑色)"]
I["4R=(Green+绿色)"]
J["4R+(Yellow+黄色)"]
K["DI 3 /DO 4(White 白色) (Wiegand) (DATA 0)"]
L["DI-2/DO-3-(Brown+棕色) (DATA-1)"]
M["DI-1+(Blue+蓝色)"]
end
subgraph PC
N["DC Power"]
O["GROUND"]
P["Doorbell"]
Q["Door Sensor"]
R["Door Button"]
end
F --> G
H --> I
I --> J
J --> K
K --> L
L --> M
M --> N
style F fill:#f9f,stroke:#333
style H fill:#f9f,stroke:#333
style I fill:#f9f,stroke:#333
style J fill:#f9f,stroke:#333
style K fill:#f9f,stroke:#333
style L fill:#f9f,stroke:#333
style M fill:#f9f,stroke:#333
Relay COM

text_image
DO1 1 NG1-(Brown-棕色) -GND COM1-(Orang-橘色) +12V DC NO1-(Yellow-黄色) - + DO2 NG2-(Green-绿色) - + GOM2-(Blue-蓝色) +12V DC - -GND E-Lock
text_image
Ethernet RED 8V TO 28VDC BLACK GROUND GREEN 4R- RS485 YELLOW 4R+ (WEGAND) WHITE DI3/DO 4 (DATA 0) BROWN DI2/DO 3 (DATA 1) BLUE DI 1 BROWN NC 1 DO 1 ORANGE COM 1 YELLOW NO 1 GREEN NC 2 DO 2 BLUE COM 2 PURPLE NO 2 Micro USBMicro USB For setup only
III. Network Parameter Setting
- Execute "NET_Discover_V0110.exe" and press to search QUIO series product.
- Factory default IP is "192.168.1.101". User can check the MAC address from product sticker with IP to confirm the device.

text_image
NET_Discover Version 1.1 NUM IP MAC INFO 3 192.168.1.221 44:33:4C:C4:8A:26 HLK-RM04(V1.78(Jul 23 2013)) 2 192.168.1.101 AC:A2:13:B5:5A:71 HLK-RM04(V1.78(Jul 23 2013)) 1 192.168.1.181 AC:A2:13:B5:5A:D9 HLK-RM04(V1.78(Jul 23 2013)) DiscoverQU-KD2N TCP/IP OLED Display Reader Operation Manual
- Double click IP (192.168.1.101) to open the web configure page(http://192.168.1.101)
Default login ID / Password : admin / admin

- Default Net Mode is the same as the following. User can modify Net Mode and other parameters. If device cannot communicate properly after setting, user can reset NET module via Micro USB.
| Settings | Network | Serial 0 | Serial 1 | |
| Current | Updated | |||
| Baudrate | 230400 | 230400 | ||
| Data Width | 8 | 8▼ | ||
| Parity | NONE | NONE▼ | ||
| Stop Bit | 1 | 1▼ | ||
| Flow Control | Disable | Disable▼ | ||
| Socket Protocol Type | Tcp Server | Tcp Server▼ | ||
| Locale Port | 5001 | 5001 | ||
| Packet Framing Lenth | 1050 | 1050 | ||
| Packet Framing Timeout | 3 | 3 | ||
| Packet Framing Interval | 3 | 3 | ||
| TCP Timeout | 0 | 0 | ||
| Reconnect Interval | 200 | 200 | ||
| TCP Keep Alive | 1 | 1 | ||
| TCP Max Connect | 100 | 100 | ||
| Without data Timeout | 60 | 60 | ||
| Communication Parameter | Factory Default |
| Serial Configure | 230400,8,n,1 |
| Serial Framing Length | 1050 |
| Locale/Remote Port Number | 5001 |
IV. Network Mode Switch
QUIO device support 4 network modes: Default、ETH(Ethernet)、Wi-Fi(STA)
| Default Ethernet (DHCP) +Wi-Fi AP mode | |
| ETH | Ethernet only |
| WIFI(STA) Wi-Fi client | mode |
1
. ETH : Factory default is ETH-SERIAL. ( Standard TCP/IP Reader )

text_image
WELCOME 2017/03/28 [TUE] 13:52:43 1 2 3 4 5 6 7 8 9 * 0 # SYRIS Ethernet only Switch / RouterWhen user modify the IP and click on Apply button, device will reboot and apply the setting after 30 seconds.
| Current | Updated | |
| Network Mode | Default | ETH |
| IP Type | Static | Static |
| IP Addr | 192.168.1.101 | 192.168.1.101 |
| Mask | 255.255.255.0 | 255.255.255.0 |
| Gateway | 192.168.1.254 | 192.168.1.254 |
| Dns | 192.168.1.254 | 192.168.1.254 |
QU-KD2N TCP/IP OLED Display Reader Operation Manual
- WIFI(STA) : QUIO can be set to communicate via Wireless AP without Ethernet.

text_image
WELCOME 2017/03/28 [TUE] 13:52:43 1 2 3 4 5 6 7 8 90 #
SYRISWi-Fi client mode



natural_image
Illustration of a gray wireless router with two antennas (no text or symbols)Wi-Fi AP
| Settings | Network | Serial 0 | Serial 1 |
| Current | Updated | |
| Network Mode | Default | WIFI(STA)▼ |
| STA SSID | Delta-IoT | Delta-IoT Scan |
| STA EncType | Open | Open▼ |
| STA Passwd | ||
| IP Type | Static | Static▼ |
| IP Addr | 192.168.1.101 | 192.168.1.101 [IMAGE] |
| Mask | 255.255.255.0 | 255.255.255.0 |
| Gateway | 192.168.1.254 | 192.168.1.254 |
| Dns | 192.168.1.254 | 192.168.1.254 |
STA SSID: Enter the SSID from AP you will connect to network.
Scan: User can scan AP in range of device and select one to connect. But user cannot scan the AP after changing default network mode (Ethernet only) to Wi-Fi (Client). Device need to power off / on to enable the scan function.
STA EncType : Select Encrypt type for AP connection.
Password: Enter password for AP.
IP Type: DHCP is default mode. If user have to setup a static IP, please select Static.
PS: Wi-Fi MAC address is Ethernet MAC subtract 1.
Ex. Ethernet MAC : AC:A2:13:B5:5A:B5, Wi-Fi MAC : AC:A2:13:B5:5A:B4
QU-KD2N TCP/IP OLED Display Reader Operation Manual
3
Default mode: Ethernet (DHCP) ±Wi-Fi AP mode. It's Dual-Mode (Ethernet and Wi-Fi AP, but Ethernet only support DHCP.)

flowchart
graph TD
A["Default mode"] --> B["DHCP"]
B --> C["Switch / Router"]
C --> D["Computer or Smart phone"]
style A fill:#f9f,stroke:#333
style B fill:#ccf,stroke:#333
style C fill:#cfc,stroke:#333
style D fill:#fcc,stroke:#333
QU-KD2N TCP/IP OLED Display Reader Operation Manual
| Settings | Network | Serial 0 | Serial 1 | |
| Current | Updated | |||
| Network Mode | Default | Default | ||
| IP Type | Static | Static | ||
| IP Addr | 192.168.1.101 | 192.168.1.101 | ||
| Mask | 255.255.255.0 | 255.255.255.0 | ||
| Gateway | 192.168.1.254 | 192.168.1.254 | ||
| Dns | 192.168.1.254 | 192.168.1.254 | ||
| AP Enable | Enable | Enable | ||
| AP SSID | SerialWiFi_0EA0 | SerialWiFi_0EA0 | ||
| AP EncType | WPA2AES | WPA2AES | ||
| AP Passwd | 12345678 | 12345678 | ||
| LAN IP Addr | 192.168.16.254 | 192.168.16.254 | ||
| LAN Mask | 255.255.255.0 | 255.255.255.0 | ||
| DHCP Server | Enable | Enable | ||
AP SSID: Setup device's SSID.
AP Passwd: Device's Wi-Fi password. (Default is 12345678)
V. USB Connection
Setup parameters via Micro USB.

text_image
Micro USB Ethernet AM MS F1- Install USB driver "CDC_USB_Driver_VCP_V1.4.0_Setup.exe"
- System will generate a virtual COM port.
For example. Check port in device manager.(below picture is COM 3)

text_image
Computer Management File Action View Help Computer Management (Local) System Tools Task Scheduler Event Viewer Shared Folders Local Users and Groups Performance Device Manager Storage Disk Management Services and Applications Mice and other pointing devices Monitors Network adapters Portable Devices Ports (COM & LPT) Communications Port (COM1) STMicroelectronics Virtual COM Port (COM3) Print queues Printers Processors Software devices Sound, video and game controllers Storage controllers System devices Universal Serial Bus controllers WSD Print ProviderQU-KD2N TCP/IP OLED Display Reader Operation Manual
User also can update driver manually. The driver is saved in the folder that is same as following.

text_image
Virtual comport driver File Home Share View C:\Program Files (x86)\STMicroelectronics\Software\Virtual comport driver Search Virtual comport driver Favourites None Data modified Type Size Desktop Win7 7/27/2015 9:43 AM File folder Downloads Win8 7/27/2015 9:43 AM File folder Recent places.version 10/19/2014 12:13 ... TXT File 3 KB 3 items 1 item selected 2.31 KB Type: TXT File, Size: 2.31 KB, Date modified: 10/19/2014 12:13 PM 2.31 KB Computer- Get device Model information and serial number by using V8 Tools with correct COM port or Ethernet connection.

text_image
V7 Tools V0771 File Language About COM | NET | Port 1 COM3 Speed: 19200 Even Parity 8 Data Bits 1 Stop Bits 19200.E.8.1 2 Open Response ID 1 S/N 12345678 PIN 0000 CRC BCC Encrypt(None) Direct COMMON COMM. DI/DO READER KEYPAD 86 Serial BT Card Controller CARD LOG CLOCK/MASTER MIFARE ISC 3 Get S/N 4 Model: 0608 SYSR86N-HBX1 S/N: 12345678 Get ID ID: 1 Special: 0000 Set ID ID: 1 Get Version Name: SYSR86N-HBX1 F/W version: 0715 Warm Start Initial NET Initial(6 Sec) Port open COM3 19200.E.8.1 DefaultVI. V8 Tools Tool Parameter Setting
1. Basic:

text_image
V8 Tools V0871 File Language About COM NET IP: 192.168.1.101 NET Search Web Config Account = admin Password = admin Port 5001 Connect Response ID 1 S/N 20470011 PID/CID: 00000000 CRC-16 AES-128 Direct COMMON COMM DI/DO READER CPU CARD QRCode KEYPAD SY86/SY2 BT Card CARD LOG CONTROLLER C Get S/N Model: 06D6 SYQR86N-H1 S/N: 20470011 Get ID ID: 1 Special Set ID ID: 1 Get Version Name: SYQR86N-H1 F/W version: 0861 Warm Start FRAM: FLASH: Initial NET Initial(10 Sec) NET IP:101 NET DHCP Memory Connect IP: 192.168.1.101:5001 DefaultBasic: Get device serial number, device ID and firmware version
Warm Start: Reboot device
Initial: Restore device to factory default (It is NOT including network setting).
NET Initial (6 sec): Restore network parameter of device to Default mode.
2. Reader

text_image
V8 Tools V0871 File Language About COM NET IP: 192.168.1.101 NET Search Web Config Account = admin Password = admin Port: 5001 Close Response ID 1 S/N 20470011 PID/CID: 00000000 CRC-16 AES-128 Direct COMMON COMM DI/DO READER CPU CARD ORCode KEYPAD SY86/SY2 BT Card CARD LOG CONTROLLER C Set Interface Interface: RS485 WIEGAND: 26 bits RS485: 64 bits R-UID Get Set Message Mode Active Blue(Power) LED Card LED: 30 x10ms Card BEEP: 30 x10ms Get ISO14443A/B/ISO15693 Same Card Delay: 10 x100ms Green Mode Reset Card Type: UID(A) Block UID(B) GUID(B) ISO15693 Use 7 Byte CPU Set Card Mode Get Card test DI: TYPE: ID: Delay: 100 ms Auto Read None Test Messgae Command ok Connect IP: 192.168.1.101.5001 DefaultSet Interface: Setup reader's communication interface. Default is "RS485".
Set Message Mode:
Card LED: Time for read card LED ON, default is 30 x 10ms
Card Beep: Time for read card beep on, default is 30 x 10ms
ISO14443A/B/ISO15693 :
Same Card Delay: Setup time gap for reading the same card, default is 10 x100ms (1 second)
Green Mode: Slow down the card read speed to power saving.
Reset: Reset RF IC after read card.
Card Type: Choose card type to enable device's read specific card.
UID(A): Read ISO14443A Card UID.
Block: Read Block data (Must disable other card type).
UID(B): Read ISO14443B Card UID.
GUID(B): Read the China second generation of resident identification card.
ISO15693: Read ISO15693 Card UID
7 byte: Read 7byte format Card UID
Card Test: Test the reader function.
QU-KD2N TCP/IP OLED Display Reader Operation Manual
Display : Set up display language and encode for different country. 3.

text_image
V8 Tools V0871 File Language About COM | NET | Port: COM10 Speed: 19200 Even Parity 8 Data Bits 1 Stop Bits 19200,E,B,1 Open Response ID S/N 18039001 PID/CID: 00000000 CRC-16 AES-128 Direct UHF UHF TID KEYPAD SY86/SY2 BT Card CARD LOG CONTROLLER DISPLAY CLOCK/MASTER SECURITY COI ▶ Display Setting English Set Language Get UNICODE Set Encode Get 24H Set Hour Mode Get YYYY/MM/DD Week Date Type Get Title_Message Title Status Message Action Meeting Notice Set Title Message Clear Title Message Get Good morning Show Message Beeper LED Green LED Red Show Delay: 30 0.1s Off Message Show Always Port open COM10 19200,E,8,1 DefaultTest send message command with tools.

text_image
Title_Message Title | Status | Message | Action | Meeting Notice Set Title Message | Clear Title Message | Get Good morning. Show Message Beeper ✓ LED Green ✓ LED Red Show Delay: 30 0.1s Show Always Off MessageAuto send reader mode
- Un-Select "Controller Mode" and then click "Set DI/DO Mode" to disable controller mode.

text_image
V8 Tools V0871 File Language About COM NET IP: 192.168.1.241 NET Search Web Config Account = admin Password = admin Port: 5001 Connect Response ID 1 S/N 20470003 PID/CID: 00000000 CRC-16 AES-128 Direct COMMON COMM DI/DO READER CPU CARD QRCode KEYPAD SY86/SY2 BT Card CARD LOG CONTROLLER C Touch IR Sensor HF/LF Read: Auto Touch Key: CALL IR Sensor: DI4 IR Power: 10% Set Touch IR Sensor Get Xtive TAG/BT BT Xtive Xtive TAG: Key Exciter ID: 0 0 Mute Same: 50 Gain: 13 RSSI: 120 Set Xtive TAG/BT Get DI/DO Mode Set DI/DO Mode Get RS485 Mode WIEGAND Mode Controller Controller Mode BCard Free Mode Patrol Mode Xtive Direct Mode RS485 Master Mode Wiegand Reader Mode DO Time (Unit:0.1 Sec) DO1: 50 DO3: 50 DO5: 50 DO2: 50 DO4: 50 DO6: 50 Connect IP: 192.168.1.241.5001 Default- Select "EN" (means enable), "S/N", "CLR", "CRC" and set heartbeat to 50 (means 5 sec) and then click "Auto Mode" to finish configure.