USER MANUAL CU-U28RKR PANASONIC

Operating Instructions

Air Conditioner

PANASONIC CU-U28RKR - Operating Instructions - 1

text_image Menubox Actions: 17:24

Model No.

Indoor Unit Outdoor Unit

CS-U18RKR

CU-U18RKR

CS-U24RKR

CU-U24RKR

CS-U28RKR

CU-U28RKR

PANASONIC CU-U28RKR - Operating Instructions - 2

PANASONIC CU-U28RKR - Operating Instructions - 3

Operating Instructions Air Conditioner

Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached.

Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

Provide fast cooling, maximum comfort, clean air and optimise energy saving

i AUTO-X Cooling when it counts, Comfort when it matters

i AUTO-X with the new Panasonic Thermal Enhancement Technology (P-TECh) is a unique Panasonic compressor control technology which enable compressor to achieve maximum frequency in a short time.

i AUTO-X also comes with new AEROWINGS - twin flaps that works dynamically to adjust airflow directions. AEROWINGS gives you fast cooling at start up by directing airflow downwards*, and comfort of shower cooling by directing airflow upwards*.

So, you get to enjoy instant fast cooling satisfaction on a hot day and cooling comfort that goes on all day long.

*Applicable for horizontal fl ap AUTO setting.

PANASONIC CU-U28RKR - Provide fast cooling, maximum comfort, clean air and optimise energy saving - 1

natural_image Black-and-white illustration of a branch with five heart-shaped leaves (no text or symbols)

Quick guide

PANASONIC CU-U28RKR - Quick guide - 1

text_image Diagram showing three labeled components of a mechanical or electronic component with directional arrows indicating flow or movement.

Inserting the batteries

① Pull out the back cover of remote control
② Insert AAA or R03 batteries (can be used \~ 1 year)
③ Close the cover

PANASONIC CU-U28RKR - Inserting the batteries - 1

text_image 1 SET 2 3 OFF CANCE SET CHECK CLOCK ON ON SET CHECK CLOCK ON INVERTER

Clock setting

① Press CLOCK
② Set the time
③ Confi rm

PANASONIC CU-U28RKR - Clock setting - 1

text_image AIR CD NOT TO NIR MODE TEMP AUTO X OFF ON CO HV AUTO AUTO 12:00 AIR SWING QUIET FIXED TIMER ON 1 2 SET OFF 3 SAVE SET CHICK CLOCK AC AC RESET Panasonic INVERTER

Basic operation

PANASONIC CU-U28RKR - Basic operation - 1

flowchart
graph TD
    A["Select the desired mode"] --> B["i AUTO-X COOL"]
    B --> C["FAN ← DRY ←"]
    C --> D["Start/stop the operation"]
    D --> E["POWER"]

PANASONIC CU-U28RKR - Basic operation - 2

Start/stop the operation

PANASONIC CU-U28RKR - Basic operation - 3

- Please note that the OFF indication OFF on to start.

③ Select the desired temperature

  • Selection range: 16 °C \~ 30 °C (Not applicable for FAN mode).
  • Operating the unit within the recommended temperature may save energy.
    COOL: 26 °C \~ 28 °C.
    DRY: 1 °C \~ 2 °C lower than room temperature.

PANASONIC CU-U28RKR - Basic operation - 4

text_image 8m
  • To dim or restore the unit's indicator brightness, press and hold for 5 seconds.
  • Use remote control within 8 m from the remote control receiver of the indoor unit.

The illustrations in this manual are for explanation purposes only and may differ from the actual unit. They are subject to change without notice for future improvement.

Table of contents

Safety precautions ....4-5

How to use......6-7

To learn more....8

Cleaning instructions .....9

Troubleshooting 10

Information....11

Accessories

  • Remote control
    • AAA or R03 batteries × 2
  • Remote control holder
  • Screws for remote control holder × 2
PANASONIC CU-U28RKR - Accessories - 1WARNINGThis symbol shows that this equipment uses a fl ammable refrigerant. If the refrigerant is leaked, together with an external ignition source, there is a possibility of ignition.
PANASONIC CU-U28RKR - Accessories - 2CAUTIONThis symbol shows type of fl ammable refrigerant contained in the system.
PANASONIC CU-U28RKR - Accessories - 3CAUTIONThis symbol shows that the Operation Instructions should be read carefully.
PANASONIC CU-U28RKR - Accessories - 4CAUTIONThis symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions.
PANASONIC CU-U28RKR - Accessories - 5CAUTIONThis symbol shows that there is information included in the Operation Instructions and/or Installation Instructions.

To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below:

PANASONIC CU-U28RKR - Accessories - 6

This appliance is fi lled with R32 (mild fl ammable refrigerant). If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fi re.

PANASONIC CU-U28RKR - Accessories - 7

WARNING

This sign warns of death or serious injury.

PANASONIC CU-U28RKR - WARNING - 1

CAUTION

This sign warns of injury or damage to property.

The instructions to be followed are classified by the following symbols:

PANASONIC CU-U28RKR - CAUTION - 1

This symbol denotes an action that is PROHIBITED.

PANASONIC CU-U28RKR - CAUTION - 2

PANASONIC CU-U28RKR - CAUTION - 3

PANASONIC CU-U28RKR - CAUTION - 4

PANASONIC CU-U28RKR - CAUTION - 5

These symbols denote actions COMPULSORY.

PANASONIC CU-U28RKR - CAUTION - 6

text_image Indoor unit Power supply Air inlet Remote control Air outlet Air inlet Outdoor unit

Air outlet

PANASONIC CU-U28RKR - CAUTION - 7

WARNING

Indoor unit and outdoor unit

PANASONIC CU-U28RKR - Indoor unit and outdoor unit - 1

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

The appliance shall be installed and operated in a room with floor area larger than 2.06m ^2 and keep away from ignition sources (such as heat/sparks/open-flame) or, hazardous areas (such as gas appliances, gas cooking, reticulated gas supply systems, or electric cooling appliance, etc.

(Refer to the Installation Instruction table A_(m^2) )

Be aware that refrigerant may not contain an odour, highly recommended to ensure suitable fl ammable refrigerant gas detectors are present, operating and able to warn of a leak.

Please consult authorised dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fire.

Confir rm with authorised dealer or specialist on usage of any specifi ed refrigerant type. Using refrigerant type other than the specifi ed may cause product damage, burst and injury etc.

PANASONIC CU-U28RKR - Indoor unit and outdoor unit - 2

Do not use means to accelerate the defrosting process or to clean, other than those recommended by manufacturer. Any unfit method or using incompatible material may cause product damage, burst and serious injury.

Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, flame, sparks, or other sources of ignition. Else it may explode and cause injury or death.

Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.

Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.

PANASONIC CU-U28RKR - Indoor unit and outdoor unit - 3

Do not touch the outdoor unit during lightning, it may cause electric shock.

Do not expose yourself directly to cold air for a long period to avoid excess cooling.

Do not sit or step on the unit, you may fall down accidentally.

PANASONIC CU-U28RKR - Indoor unit and outdoor unit - 4

Remote control

PANASONIC CU-U28RKR - Remote control - 1

Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.

Power supply

PANASONIC CU-U28RKR - Power supply - 1

Do not use a modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire.

PANASONIC CU-U28RKR - Power supply - 2

PANASONIC CU-U28RKR - Power supply - 3

To prevent overheating, fire or electric shock:

  • Do not share the same power outlet with other equipment.
  • Do not operate with wet hands.
  • Do not over bend the power supply cord.
  • Do not operate or stop the unit by inserting or pulling out the power plug.

PANASONIC CU-U28RKR - Power supply - 4

If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualified persons in order to avoid a hazard.

It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fire.

To prevent overheating, fi re or electric shock:

  • Insert the power plug properly.
  • Dust on the power plug should be periodically wiped with a dry cloth.

Stop using the product if any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock) Examples of abnormality/failure

• The ELCB trips frequently.
- Burning smell is observed.
- Abnormal noise or vibration of the unit is observed.
• Water leaks from the indoor unit.

• Power cord or plug becomes abnormally hot.

• Fan speed cannot be controlled.

- The unit stops running immediately even if it is switched on for operation.

- The fan does not stop even if the operation is stopped.

Contact your local dealer immediately for maintenance/repair.

PANASONIC CU-U28RKR - Power supply - 5

This equipment must be earthed to prevent electrical shock or fire.

PANASONIC CU-U28RKR - Power supply - 6

Prevent electric shock by switching off the power supply and unplug:

  • Before cleaning or servicing,
  • When extended non-use, or
  • During abnormally strong lightning activity.

PANASONIC CU-U28RKR - Power supply - 7

PANASONIC CU-U28RKR - Power supply - 8

PANASONIC CU-U28RKR - Power supply - 9

CAUTION

Indoor unit and outdoor unit

PANASONIC CU-U28RKR - Indoor unit and outdoor unit - 1

Do not wash the indoor unit with water, benzine, thinner or scouring powder to avoid damage or corrosion at the unit.

Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc.

Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation.

Do not expose plants or pet directly to airflow to avoid injury, etc.

Do not touch the sharp aluminium fi n, sharp parts may cause injury.

PANASONIC CU-U28RKR - Indoor unit and outdoor unit - 2

Do not switch ON the indoor unit when waxing the floor. After waxing, aerate the room properly before operating the unit.

Do not install the unit in oily and smoky areas to prevent damage to the unit.

Do not dismantle the unit for cleaning purpose to avoid injury.

Do not step onto an unstable bench when cleaning the unit to avoid injury.

Do not place a vase or water container on the unit. Water may enter the unit and degrade the insulation. This may cause an electric shock.

Do not open window or door for long time during operation, it may lead to ineffi cient power usage and uncomfortable temperature changes.

PANASONIC CU-U28RKR - Indoor unit and outdoor unit - 3

Prevent water leakage by ensuring drainage pipe is:

  • Connected properly,
  • Kept clear of gutters and containers, or
  • Not immersed in water

After a long period of use or use with any combustible equipment, aerate the room regularly.

After a long period of use, make sure the installation rack does not deteriorate to prevent the unit from falling down.

Remote control

PANASONIC CU-U28RKR - Remote control - 1

Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control.

PANASONIC CU-U28RKR - Remote control - 2

To prevent malfunction or damage of the remote control:

  • Remove the batteries if the unit is not going to be used for a long period of time.
  • New batteries of the same type must be inserted following the polarity stated.

Power supply

PANASONIC CU-U28RKR - Power supply - 1

Do not disconnect the plug by pulling the cord to prevent electric shock.

PANASONIC CU-U28RKR - Power supply - 2

To reach temperature quickly

i AUTO-X

- The unit controls set temperature according to room temperature to accelerate room cooling.

PANASONIC CU-U28RKR - i AUTO-X - 1

text_image i AUTO-X — Set temperature -1°C Max = 4 hours

• After max 4 hours, the set temperature follows the last set temperature setting.
- Fan speed is fixed at AUTO, fan speed selection is prohibited.
- During unit is off, press will turn on the unit with i AUTO-X mode.
- i AUTO-X mode can be cancelled by pressing the respective button again.

MODE

To select operation mode

i AUTO-X - To reach temperature quickly

COOL - To enjoy cool air

DRY - To dehumidify the environment

FAN - To circulate air in the room

POWERFUL

To reach temperature quickly

POWERFUL

• This operation stops automatically after 20 minutes.

QUIET

To enjoy quiet operation

QUIET

- This operation reduces airflow noise.

FAN SPEED

To select fan speed

(Remote control display)

PANASONIC CU-U28RKR - To select fan speed - 1

  • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.
  • If i AUTO-X mode is set, fan speed is fixed to AUTO. To adjust fan speed, cancel i AUTO-X mode.

PANASONIC CU-U28RKR - To select fan speed - 2

text_image Remote control receiver Indicator (Green) (Orange) (Orange) (Orange) (Orange) (Orange) (Orange) POWER TIMER i AUTO-X ECONOMY POWERFUL QUIET

Remote control display
PANASONIC CU-U28RKR - To select fan speed - 3

text_image AIR CONDITIONER MODE OFF AUTO-X 25 °C AUTO AUTO AUTO AUTO I AUTO-X GE/ ON MODE ECONOMY TEMP POWERFUL AIR SWING QUIET FAN SPEED TIMER ON 1 2 SET OFF 3 UN.E. AC RC SET CHECK CLOCK RESET Panasonic INVERTER Press and hold for approximately 10 seconds to show temperature setting in °C or °F. Press to restore the remote control to default setting. Not used in normal operations.

Auto OFF/ON button

PANASONIC CU-U28RKR - Auto OFF/ON button - 1

natural_image Diagram showing a mechanical component with an arrow pointing to a circular feature (no text or symbols present)

Use when remote control is misplaced or a malfunction occurs. Raise the front panel:

• To use in i AUTO-X mode, press the button once.
- To use in COOL mode, press and hold the button until 1 beep is heard, then release.
- Press the button again to turn off.

PANASONIC CU-U28RKR - Auto OFF/ON button - 2

To save electrical power consumption

ECONOMY

  • Save power consumption at unoccupied room by adjust set temperature up to 3°C automatically.
  • Brightness of all indicators will be dimmed.

PANASONIC CU-U28RKR - ECONOMY - 1
AIR SWING

PANASONIC CU-U28RKR - ECONOMY - 2

To adjust airflow direction

(Remote control display)

PANASONIC CU-U28RKR - To adjust airflow direction - 1

flowchart
graph LR
    A["Start"] --> B["Step 1"]
    B --> C["Step 2"]
    C --> D["Step 3"]
    D --> E["Step 4"]
    E --> F["End"]
    G["Start"] --> H["Step 5"]
    H --> I["Step 6"]
    I --> J["Step 7"]
    J --> K["Step 8"]
    K --> L["End"]
  • Keeps the room ventilated.
  • In COOL/DRY mode, if AUTO is set, the fl aps swings left/right and up/down automatically.
  • In i AUTO-X mode, if AUTO is set, the horizontal fl ap is fi xed at the lower position and shift to the upper position after reaches set temperature. The vertical flap movement will fixed at predetermined position.
  • If manual is set, the horizontal and vertical fl ap are fixed at the predetermined position.
  • Do not adjust the flap by hand.

Auto Restart Control

  • If power is resumed after a power failure, the operation will restart automatically after a period of time with previous operation mode and airflow direction.
  • This control is not applicable when TIMER is set.

To set the timer

2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times.

PANASONIC CU-U28RKR - To set the timer - 1

text_image 1 2 3 ON 1 OFF ▲ 2 SET 3 FAWEI

① Select ON or OFF timer

• Each time pressed:

PANASONIC CU-U28RKR - ① Select ON or OFF timer - 1

② Set the time

③ Confi rm

Example: OFF at 22:00

PANASONIC CU-U28RKR - ③ Confi rm - 1

PANASONIC CU-U28RKR - ③ Confi rm - 2

PANASONIC CU-U28RKR - ③ Confi rm - 3

PANASONIC CU-U28RKR - ③ Confi rm - 4

PANASONIC CU-U28RKR - ③ Confi rm - 5

PANASONIC CU-U28RKR - ③ Confi rm - 6

PANASONIC CU-U28RKR - ③ Confi rm - 7

  • To cancel ON or OFF timer, press ON or OFF to select respective or then press CANCEL.
  • If timer is cancelled manually or due to power failure, you can restore the timer again by pressing ON or OFF to select respective ④or ② then press SET.
  • The nearest timer setting will be displayed and will activate in sequence.
  • When ON Timer is set, the unit may start earlier (up to 15 minutes) before the actual set time in order to achieve the desired temperature on time.
  • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Quick guide.

Note

QUIET

POWERFUL

ECONOMY

- Can be activated in COOL and DRY mode and can be cancelled by pressing the respective button again.

PANASONIC CU-U28RKR - Note - 1

QUIET

POWERFUL

ECONOMY

- Cannot be selected at the same time.

Operation mode

i AUTO-X : The fast cooling is ideal when you come home on a hot day.

COOL : Provides efficient comfort cooling to suit your needs.

DRY : Unit operates at low fan speed to give a gentle cooling operation.

FAN : To circulate air in the room.

Operation conditions

Use this air conditioner under the following temperature range.

DBT : Dry bulb temperature

WBT : Wet bulb temperature

Temperature (°C)Indoor Outdoor
DBT WBTDBT WBT
COOLMax. 32 23 46 26
Min. 16 115

To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Dirty unit may cause malfunction and you may see error code "H99". Please consult authorised dealer.

  • Switch off the power supply and unplug before cleaning.
  • Do not touch the aluminium fi n, sharp parts may cause injury.
  • Do not use benzine, thinner or scouring powder.
  • Use only soap (≈ pH 7) or neutral household detergent.
  • Do not use water hotter than 40^ .

Indoor unit

Wipe the unit gently with a soft, dry cloth.

PANASONIC CU-U28RKR - Indoor unit - 1

Outdoor unit

Clear debris that surround the unit. Clear any blockage from drain pipe.

PANASONIC CU-U28RKR - Outdoor unit - 1

Front panel

Wash gently and dry.

Remove the front panel
PANASONIC CU-U28RKR - Front panel - 1

text_image ① Raise ② Pull out

Close it securely
PANASONIC CU-U28RKR - Front panel - 2

text_image Insert at both sides1

② Close down
③ Press both ends of the front panel
④ Press at center of the front panel.

Indoor unit
Aluminium fi nFront panel
PANASONIC CU-U28RKR - Front panel - 3

natural_image Cross-sectional diagram of an air conditioner unit showing internal components and airflow paths (no text or labels)

Air filters
Anti-bacterial filter

Air fi Iters

Every 2 weeks

  • Wash/rinse the fi Iters gently with water to avoid damage to the fi Iter surface.
  • Replace any damaged filters.

- Dry the fi Iters thoroughly under shade, away from fi re or direct sunlight.

Remove air filter
PANASONIC CU-U28RKR - Every 2 weeks - 1

natural_image Illustration of a hand holding a grid-like object over a train track (no text or symbols visible)

PANASONIC CU-U28RKR - Every 2 weeks - 2

Attach air filter
PANASONIC CU-U28RKR - Every 2 weeks - 3

natural_image Illustration of hands holding a grid-based panel in an industrial setting (no text or symbols visible)

Insert into the unit

Anti-bacterial fi Iter

PANASONIC CU-U28RKR - Anti-bacterial fi Iter - 1
Anti-bacterial fi Iter.

  • Clean the fi Iter whenever necessary.
  • Wash/rinse the filter gently with water to avoid damage to the filter.
  • Dry the fi Iter thoroughly under the shade, away from fi re or direct sunlight.
  • Replace the fi Iter every 10 years or replace any damaged fi Iter. Part no.: CZ-SA22P

For seasonal inspection after extended non-use

  • Checking of remote control batteries.
  • No obstruction at air inlet and air outlet vents.
  • Use Auto OFF/ON button to select COOL operation. After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents:

PANASONIC CU-U28RKR - For seasonal inspection after extended non-use - 1

For extended non-use

  • Turn off the power supply and unplug.
  • Remove the remote control batteries.

The following symptoms do not indicate malfunction.

Symptom Cause
Mist emerges from indoor unit. • Condensation effect due to cooling process.
Water flowing sound during operation.• Refrigerant flow inside the unit.
The room has a peculiar odour. • This may be due to damp smell emitted by the wall, carpet, furniture or clothing.
Indoor fan stops occasionally during automatic fan speed setting.• This helps to remove the surrounding odour.
Operation is delayed a few minutes after restarting.• The delay is a protection to the unit's compressor.
Outdoor unit emits water/steam. • Condensation or evaporation occurs on pipes.
TIMER indicator is always on. • The timer setting repeats daily once set.
POWER indicator blinks before the unit is switched on.• This is a preliminary step in preparation for the operation when the ON timer has been set.
Cracking sound during operation. • Changes of temperature caused the expansion/contraction of the unit.
Discoloration of some plastic parts. • Discoloration is subject to material types used in plastic parts, accelerated when exposed to heat, sun light, UV light, or environmental factor.
Louder noise at outdoor unit during early operation of i AUTO-X.• The compressor and fan rotate at higher speed to boost cooling performance during initial operation.

Check the following before calling for servicing.

Symptom Check
Operation in COOL mode is not working effi ciently.Set the temperature correctly.Close all doors and windows.Clean or replace the fi Iters.Clear any obstruction at the air inlet and air outlet vents.
Noisy during operation. • Check if the unit has been installed at an incline.Close the front panel properly.
Remote control does not work.(Display is dim or transmission signal is weak.)Insert the batteries correctly.Replace weak batteries.
The unit does not work.Check if the circuit breaker is tripped.Check if timers have been set.
The unit does not receive the signal from the remote control.Make sure the receiver is not obstructed.Certain fluorescent lights may interfere with signal transmitter. Please consult authorised dealer.

NON SERVICEABLE CRITERIAS

TURN OFF POWER SUPPLY AND UNPLUG then please consult authorised dealer under the following conditions:

• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
- Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
- Switches or buttons are not functioning properly.

Use remote control to retrieve error code.

PANASONIC CU-U28RKR - The unit stops and the TIMER indicator blinks. - 1

text_image ① Press for 5 seconds ② Press until you hear beep sound, then write down the error code ③ Press for 5 seconds to quit checking ④ Turn the unit off and reveal the error code to authorised dealer

- For certain errors, you may restart the unit for limited operation with 4 beeps when operation starts.

Information for Users on Collection and Disposal of Old Equipment and used Batteries

PANASONIC CU-U28RKR - Information for Users on Collection and Disposal of Old Equipment and used Batteries - 1

PANASONIC CU-U28RKR - Information for Users on Collection and Disposal of Old Equipment and used Batteries - 2

PANASONIC CU-U28RKR - Information for Users on Collection and Disposal of Old Equipment and used Batteries - 3

[Information on Disposal in other Countries outside the European Union]

These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.

Note for the battery symbol (bottom two symbol examples):

This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved.

Pb

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PANASONIC

Model : CU-U28RKR

Category : Air-conditioner