Hikvision

DS-D4215FI-CBFC/A - Surveillance Hikvision - Free user manual and instructions

Find the device manual for free DS-D4215FI-CBFC/A Hikvision in PDF.

📄 70 pages English EN Download 💬 AI Question
Notice Hikvision DS-D4215FI-CBFC/A - page 1
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about DS-D4215FI-CBFC/A Hikvision

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Surveillance in PDF format for free! Find your manual DS-D4215FI-CBFC/A - Hikvision and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DS-D4215FI-CBFC/A by Hikvision.

USER MANUAL DS-D4215FI-CBFC/A Hikvision

Full-Color LED Splicing Display Unit

Installation Guide

© 2022 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.

About this Manual

The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website

(https://www.hikvision.com/).

Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.

Trademarks

HIKVISION and other Hikvision's trademarks and logos are the properties of

Hikvision in various jurisdictions.

Other trademarks and logos mentioned are the properties of their respective owners.

HDMI™: The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI

Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. in the United States and other countries.

Disclaimer

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.

YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.

YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF

PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.

IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.

Symbol Conventions

The symbols that may be found in this document are defined as follows.

SymbolDescription
Hikvision DS-D4215FI-CBFC/A - Symbol Conventions - 1Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury.
Hikvision DS-D4215FI-CBFC/A - Symbol Conventions - 2Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.
Hikvision DS-D4215FI-CBFC/A - Symbol Conventions - 3Provides additional information to emphasize or supplement important points of the main text.

Safety Instruction

For safety concerns, the device has been strictly tested before shipment. However, incorrect installation or usage may lead to hazardous results such as electric shock and fire. To ensure the service life and best performance of the device, please read the notice and plate signs carefully and follow the safety instructions. Keep this guide properly for later use.

Caution

  • To ensure safety, the installation parts and the wall should support four times the weight of the device.
  • Install the device no more than 5 mm away from the wall or other metal racks in case of lamp board drop resulting in electric shock.
  • Please set the brightness of the LED display within 500 nits to avoid power overload.
  • The device may generate radio interference in indoor environment. Necessary precautions may be required.
  • To reduce the risk of fire or electric shock, please do not expose the device to rain or humid environment.
  • Electric discharge may last for a short period of time after the power is shut down. Please wait two minutes after the power is shut down before operating the device.
  • To avoid the risk of electric shock, please do not operate when the power is on.
  • Please do not plug and unplug the power cable when the power is on.
  • Ensure the correct wire sequence of the terminals connected to the AC power supply.
  • Do not place anything containing liquid on the device to avoid the risk of fire or electric shock caused by liquid-splashing.
  • The device is only suitable for installation on the concrete or non-flammable surfaces, to prevent molten material from dripping to the bottom during fire caused by internal failure.
  • Keep 90 degrees when moving and using the device.

- After installation, there should be no openings around the LED module. The bottom bracket under the wire outlet position should completely cover the bottom hole only to let the wire out, to prevent the molten material from dripping to the bottom during fire caused by internal failure.

Hikvision DS-D4215FI-CBFC/A - Caution - 1

text_image Warning Do Not Open Warning: to reduce the risk of electric shock, do not open the equipment cover. Component providing direct service does not exist in the equipment internal. You can contact professional maintenance person for corresponding service.

Warning

  • In the use of the product, you must be in strict compliance with the electrical safety regulations of the nation and region.
  • Disconnect the power plug before maintenance.
  • Make sure the power supply is well-grounded.
  • The protective grounding of the device should be reliably connected to the building protective grounding.
  • To reduce the risk of electric shock, install protective shield on the exposed connector after installing LED screen.
  • Disconnect the power plug before installing the protective shield.
  • A disconnecting device should be provided on the outside of the equipment. A single device is recommended for AC 220 V / 230 V / 240 V, 6 A circuit breakers. When multiple devices are superimposed, a suitable circuit breaker should be selected according to the total rated current, but it must not exceed the building equipped circuit specifications.
  • To prevent injury, the device must be securely fixed to the ground, wall, ceiling, or steel frame. The all-in-one rack should be fixed to the ground with expansion screws.
  • The supporting rack can only be used with the device. Using it with other devices may cause instability and injury.
  • The device can only be used with the supporting rack. Using it with other equipment (such as a cart, shelf, or handling device) may cause instability and injury.
  • Please strictly follow the installation method in this guide.
  • The external wire connection between device and hazardous electronic terminals should be operated by professionals.
  • This is a class A product and may cause radio interference in which case the user may be required to take adequate measures.
  • The socket-outlet shall be installed near the device and easily accessible.
  • This equipment is not suitable for use in locations where children are likely to be present.
  • This product can work normally only at the altitude below 5000 meters.

• WARNING

  1. Do not ingest battery. Chemical Burn Hazard!
  2. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death.
  3. Keep new and used batteries away from children.
  4. If the battery compartment does not close securely, stop using the product and keep it away from children.
  5. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
  6. CAUTION: Risk of explosion if the battery is replaced by an incorrect type.
  7. Improper replacement of the battery with an incorrect type may defeat a safeguard (for example, in the case of some lithium battery types).
  8. Do not dispose of the battery into fire or a hot oven, or mechanically crush or cut the battery, which may result in an explosion.
  9. Do not leave the battery in an extremely high temperature surrounding environment, which may result in an explosion or the leakage of flammable liquid or gas.
  10. Do not subject the battery to extremely low air pressure, which may result in an explosion or the leakage of flammable liquid or gas.
  11. Dispose of used batteries according to the instructions.

Contents

Chapter 1 Product Introduction....1

1.1 Overview....1
1.2 Product Components....1

Chapter 2 Rack Installation....2

2.1 About Rack....2
2.2 Install the Rack .... 2

2.2.1 Precautions....2
2.2.2 Install the Wall-Mounted Rack....2
2.2.3 Install the Ultrathin Rack .... 10
2.2.4 Install the All-in-One Rack 24

Chapter 3 Cabinet Installation ....43

3.1 Introduction....43
3.2 Install the Cabinets....43

3.2.1 Precautions....43
3.2.2 Stitch Cabinet Frames 43
3.2.3 Wiring 47
3.2.4 Install Lamp Boards on the Cabinets 54

Chapter 4 Software Debugging ....57

4.1 Activation....57
4.2 Login....59
4.3 Configure Signal Cables....59
4.4 Configure Screen Splicing....60

Chapter 5 Installation Guide QR Code....62

Chapter 1 Product Introduction

1.1 Overview

The full-color LED splicing display unit adopts thin and die-casting cabinet design. The four cabinets can be spliced into a 2K standard resolution display quickly. The large cabinet design can not only reduce the spliced seams and installation difficulty, but also make the display surface flatter. The device simulates the display application mode with embedded and integrated control system, making it easy to debug. The input signal can be displayed instantly after the corresponding input signal is connected. The remote controller can control the device conveniently. The humanized user interface makes it easy to operate. The device is widely applicable to the medium and small-sized splicing video wall scenes including monitoring centers, seminar rooms, commercial chains places, government and enterprise exhibition halls, etc.

1.2 Product Components

An LED control system includes sending and receiving cards. The sending card packages images and sends them to the receiving card. The receiving card unpackages and processes the images, and then displays the images on the LED display unit.

The center distance between two pixels is called pixel pitch. The smaller pixel pitch results in higher pixel density per unit area, higher resolution and higher cost. For example, P1.2 indicates 1.2 mm pixel pitch.

The product are rack-mount system. Its installation process consists rack installation and cabinet installation. The following two chapters describe how to install the rack and cabinets in details.

Chapter 2 Rack Installation

2.1 About Rack

There are three types of racks for installing our full-color LED products: wall-mounted rack, ultrathin rack and all-in-one rack. The wall-mounted rack is used for installing front-maintenance cabinets only. The ultrathin rack and all-in-one rack can be used for installing both front-maintenance cabinets and back-maintenance cabinets. Different rack models are applied to different project scales and installation environment. Thus, the illustrations of racks in this manual are for reference only.

2.2 Install the Rack

2.2.1 Precautions

  • Installation personnel must wear protective gear.
  • Take safety measures when working at height.
  • Make sure that the rack is mounted vertically to the flat ground without tilting or twisting.
  • Check that all structural parts and fasteners are fully mounted without missing.
  • After all the accessories are mounted, clean all the debris in the rack and avoid metal debris being remained.

2.2.2 Install the Wall-Mounted Rack

The wall-mounted rack is used for installing front-maintenance cabinets only.

Install the Base Frame

Steps

  1. Use header corners to connect aluminum extrusion rods from bottom to top.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Header Corner Aluminum Extrusion Rod

Figure 2-1 Assemble the Base Frame

Hikvision DS-D4215FI-CBFC/A - Steps - 2

natural_image Technical line drawing of a mechanical component with two parallel grooves and mounting holes (no text or symbols)

Figure 2-2 Base Frame Assembled

  1. Use expansion bolts, T-Shaped bolts, and fixing plates to fix the base frame onto the wall.

Hikvision DS-D4215FI-CBFC/A - Steps - 3

text_image Fixing Plate b — Expansion Bolt — T-Shaped Bolt

Figure 2-3 Fix the Base Frame onto the Wall

Install the Rack Frame

Steps

  1. Use the header corners to connect aluminum extrusion rods to the base frame from left to right.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Header Corner Aluminum Extrusion Rod

Figure 2-4 Assemble the Rack Frame

  1. Use expansion bolts, T-Shaped bolts and fixing plates to fix the rack frame onto the wall.

Hikvision DS-D4215FI-CBFC/A - Steps - 2

text_image Fixing Plate Rack Frame

Figure 2-5 Fix the Rack Frame onto the Wall

Install Cabinets into the Rack Frame

After the base frame and rack frame are well installed, take the following steps to install the cabinets into the rack frame:

Steps

  1. Place the mounting screws in the holes on the front side of the cabinet and lock the floating nuts on the rack frame.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

natural_image Technical line drawing of a modular solar panel structure with mounting holes and internal compartments, shown with magnified insets (no text or symbols)

Figure 2-6 Fix the Screen

Hikvision DS-D4215FI-CBFC/A - Steps - 2

natural_image Technical line drawing of a 3D rectangular panel with multiple square cutouts and mounting holes (no text or symbols)

Figure 2-7 Screen Fixed

  1. Install the cabinets from middle to both sides until the first row of cabinets are installed.

Hikvision DS-D4215FI-CBFC/A - Steps - 3

natural_image Technical line drawing of a 3D rectangular panel with internal grid layout and mounting holes (no text or symbols)

Figure 2-8 Screens Fixed

  1. Repeat the above steps to install other cabinets on the above rows.
  2. Use a level to measure and ensure that the cabinets are flat and vertical.

Hikvision DS-D4215FI-CBFC/A - Steps - 4

Note

  • Do not fix the screws between the connectors in case that cabinets are too tight for future adjustment.
  • In normal cases, lock out LED lamp boards after they are adjusted horizontally or vertically as the boards will probably be moved during the installation of other lamp boards.
  • Ensure that the screen is flat and there is no obvious gap between screens. Otherwise, make some adjustments.

Hikvision DS-D4215FI-CBFC/A - Note - 1

text_image Rack Frame Screen Base Frame

Figure 2-9 First Row of Fixed Screens

Hikvision DS-D4215FI-CBFC/A - Note - 2

Note

  • For details about cabinet stitching, see 3.2.2 Stitch Cabinet Frames.
  • For details about lamp boards installation, see 3.2.4 Install Lamp Boards on the Cabinets.

  • Repeat the above steps to install other cabinets.

Hikvision DS-D4215FI-CBFC/A - Note - 1

text_image Screen Base Frame

Figure 2-10 Screen Installation Finished

iNote

  • Install the device no more than 5 mm away from the wall or other metal racks, in case of lamp board drop resulting in electric shock.
  • After installation, there should be no openings around the LED modules. The bottom bracket under the wire outlet should completely cover the bottom hole only to let the wire out, to prevent the molten material from dripping to the bottom in case of fire caused by internal failure.
  • To ensure safety, the installation parts and the wall should support four times the weight of the device.

2.2.3 Install the Ultrathin Rack

The ultrathin racks are used for mounting front-maintenance products and back-maintenance products.

Install the Bottom Chassis

Steps

  1. Use header corners to connect aluminum extrusion rods from bottom to top.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Aluminum Extrusion Rod Header Corner

Figure 2-11 Assemble the Base Frame Unit

Hikvision DS-D4215FI-CBFC/A - Steps - 2

natural_image Technical line drawing of a rectangular metal frame structure (no text or symbols)

Figure 2-12 Base Frame Unit Assembled

  1. Use wedge-locking collector bolts to connect the base frame units.

Hikvision DS-D4215FI-CBFC/A - Steps - 3

text_image Base Frame Unit Wedge-locking Collector Bolts Base Frame Unit

Figure 2-13 Connect the Base Frame Units

  1. Insert the anchor bolts into the base frame and tighten the bolts.

Hikvision DS-D4215FI-CBFC/A - Steps - 4

text_image Base Chassis Anchor Bolts

Figure 2-14 Assemble the Base Frame

  1. Level the bottom chassis and then tighten the bolts.

Hikvision DS-D4215FI-CBFC/A - Steps - 5

natural_image Pure architectural or structural line drawing with no text, numbers, or symbols

Figure 2-15 Leveled Bottom Chassis

Install the Rack Frame

Steps

  1. Use header corners to connect aluminum extrusion rods from bottom to top.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Header Corner Aluminum Extrusion Rod

Figure 2-16 Assemble the Rack Frame Unit

  1. Use wedge-locking collector bolts to connect the rack frame units.

Hikvision DS-D4215FI-CBFC/A - Steps - 2

text_image Rack Frame Unit Wedge-locking Collector Bolts Rack Frame Unit

Figure 2-17 Connect the Rack Frame Units

  1. Align the rack frame to the base chassis and use wedge-locking collector bolts to fix the frames.

Hikvision DS-D4215FI-CBFC/A - Steps - 3

text_image Rack Frame Wedge-locking Collector Bolts Bottom Chassis

Figure 2-18 Align the Rack Frame to the Base Chassis

Hikvision DS-D4215FI-CBFC/A - Steps - 4

natural_image Structural diagram of a multi-story building facade with vertical panels and horizontal beams (no text or symbols)

Figure 2-19 Frames Aligned

Install the Rear Pulling Rods (for Large-scale Projects)

Steps

  1. Use the wedge-locking collector bolts to fix the rear pulling rods into the rack frame.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Rack Frame Wedge-locking Collector Bolt Rear Pulling Rod

Figure 2-20 Fix the Rear Pulling Rods into the Rack frame

Hikvision DS-D4215FI-CBFC/A - Steps - 2

natural_image Technical line drawing of a multi-level metal shelving unit (no text or symbols)

Figure 2-21 Rear Pulling Rods Fixed

  1. Use the expansion bolts to fix the rear pulling rods onto the bearing wall.

Hikvision DS-D4215FI-CBFC/A - Steps - 3

text_image Expansion Bolt Aluminum Extrusion Rod Bearing Wall

Figure 2-22 Fix the Rear Pulling Rods onto the Bearing Wall

Install the Connectors

The connectors are divided into two parts: customized front joint piece which is used to connect the screens, and back connecting component which is used to connect the rack frame. The following figures list three types of connectors and the locating positions of the connectors respectively.

Hikvision DS-D4215FI-CBFC/A - Install the Connectors - 1

natural_image Technical line drawing of a metal bracket with bolts and mounting holes (no text or symbols)

Type A Connector

Hikvision DS-D4215FI-CBFC/A - Install the Connectors - 2

natural_image Technical line drawing of a metal bracket with three bolts and mounting holes (no text or symbols)

Type B Connector

Hikvision DS-D4215FI-CBFC/A - Install the Connectors - 3

natural_image Technical line drawing of a metal bracket with bolts and mounting holes (no text or symbols)

Type C Connector
Figure 2-23 Connectors

Hikvision DS-D4215FI-CBFC/A - Install the Connectors - 4

text_image Type C Connector Type A Connector Type B Connector Type A Connector Type B Connector

Figure 2-24 Connectors Installed

iNote

Please pay attention to the types of outermost connectors between rack frame and bottom chassis.

Steps

  1. Twist the hexagonal screws into the T-Shaped nuts.
  2. Insert the T-Shaped nuts into the slots of aluminum extrusion rods, and move the connectors to the suitable place.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image T-Shaped Bolt Hexagonal Screw

Figure 2-25 Install the Connectors

  1. Secure the connectors to the rack frame with screws.

Install Cabinets into the Rack Frame

After the bottom chassis, rack frame and connectors are well installed, take the following steps to install the cabinets into the rack frame:

Steps

  1. Install the first cabinet from the lower middle part. Level and secure the cabinet to the connectors on the rack frame. For screens do not have connectors near the rear, use joint pieces to fix the screens.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Joint Pieces

Figure 2-26 Fix the Screen with Joint Pieces

Hikvision DS-D4215FI-CBFC/A - Steps - 2

Note

• Install the cabinets from the bottom to the top, from the middle to the sides.
- Do not fix the screws between the connectors in case that cabinets are too tight for future adjustment.
- In normal cases, lock out LED lamp boards after they are adjusted horizontally or vertically as the boards will probably be moved during the installation of other lamp boards.
- Ensure that the screen is flat and there is no obvious gap between screens. Otherwise, make some adjustments.

  1. Repeat the above steps to install the other cabinets in the lowest row.

Hikvision DS-D4215FI-CBFC/A - Note - 1

text_image Use joint pieces to fix the screens in the middle parts between two frame units. Use connectors to secure the screens to the rack frame.

Figure 2-27 Fix the Screens

  1. Use a level to measure and ensure that the cabinets are flat and vertical.

iNote

When there is a deviation in height, simply place a thin iron sheet under the bottom. Do not try to resolve the deviation by hitting the cabinets on the top because it will result in larger deviation afterwards.

  1. Repeat the above steps to complete the installation of other cabinets.

Hikvision DS-D4215FI-CBFC/A - iNote - 1

text_image Screens in the middle parts between two frame units are fixed with joint pieces. Screens are secured to the connectors on the rack frame.

Figure 2-28 Screens Fixed

  1. Ensure that all the cabinets are flat and vertical and the seams between the cabinets are even. Then tighten the screws to complete the installation.

Hikvision DS-D4215FI-CBFC/A - iNote - 2

natural_image Technical line drawing of a metal-framed wall structure with vertical supports and horizontal panels (no text or symbols)

Figure 2-29 Screen Installation Finished

Hikvision DS-D4215FI-CBFC/A - iNote - 3

Note

  • For details about cabinet stitching, see 3.2.2 Stitch Cabinet Frames.
  • For details about lamp boards installation, see 3.2.4 Install Lamp Boards on the Cabinets.

2.2.4 Install the All-in-One Rack

The all-in-one racks are used for mounting front-maintenance products and back-maintenance products.

Install the Bottom Chassis

Steps

  1. Use header corners to connect aluminum extrusion rods.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

Note

It is recommended to assemble the base frame units from bottom to top.

Hikvision DS-D4215FI-CBFC/A - Note - 1

text_image Aluminum Extrusion Rod Header Corner

Figure 2-30 Assemble the Base Frame Unit

Hikvision DS-D4215FI-CBFC/A - Note - 2

natural_image Line drawing of a 3D wireframe frame structure with no text or symbols

Figure 2-31 Base Frame Unit Assembled

  1. Use wedge-locking collector bolts to connect the base frame units.

Hikvision DS-D4215FI-CBFC/A - Note - 3

text_image Base Frame Unit Base Frame Unit Wedge-locking Collector Bolts

Figure 2-32 Connect the Base Frame Units

Hikvision DS-D4215FI-CBFC/A - Note - 4

natural_image Technical line drawing of a rectangular frame structure with internal supports and an inset close-up showing mechanical components (no text or symbols)

Figure 2-33 Base Frame Units Connected

  1. Repeat the above steps to connect other base frame units.

Hikvision DS-D4215FI-CBFC/A - Note - 5

natural_image Technical line drawing of a multi-story rectangular frame structure (no text or symbols)

Figure 2-34 Base Frame

  1. Insert the anchor bolts into the base frame and tighten the bolts.

Hikvision DS-D4215FI-CBFC/A - Note - 6

text_image Base Frame Anchor Bolt

Figure 2-35 Assemble the Base Frame

  1. Level the bottom chassis and then tighten the bolts.

Hikvision DS-D4215FI-CBFC/A - Note - 7

natural_image Pure architectural line drawing of a rectangular frame with corner supports and no text or symbols

Figure 2-36 Leveled Bottom Chassis

Install the Rack Frame

Steps

  1. Use header corners to connect aluminum extrusion rods.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

It is recommended to assemble the rack frame units from bottom to top.

Hikvision DS-D4215FI-CBFC/A - Steps - 2

text_image Aluminum Extrusion Rod Header Corner

Figure 2-37 Assemble the Rack Frame Unit

  1. Use wedge-locking collector bolts to connect the rack frame units.

Hikvision DS-D4215FI-CBFC/A - Steps - 3

text_image Rack Frame Unit Rack Frame Unit Wedge-locking Collector Bolt

Figure 2-38 Connect the Rack Frame Units

  1. Repeat the above steps to connect the other rack frame units.

Hikvision DS-D4215FI-CBFC/A - Steps - 4

natural_image Technical line drawing of a multi-panel metal-framed cabinet or enclosure structure (no text or symbols)

Figure 2-39 Rack Frame

  1. Align the rack frame to the base chassis and use wedge-locking collector bolts to fix the frames.

Hikvision DS-D4215FI-CBFC/A - Steps - 5

text_image Rack Frame Wedge-locking Collector Bolt Bottom Chassis

Figure 2-40 Align the Rack Frame to the Base Chassis

Hikvision DS-D4215FI-CBFC/A - Steps - 6

natural_image Technical line drawing of a multi-level metal shelving unit with structural supports (no text or symbols)

Figure 2-41 Frames Aligned

Install the Rear Pulling Rods (for Large-scale Projects)

Steps

  1. Use the wedge-locking collector bolts to fix the rear pulling rods into the rack frame.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Real Pulling Rod Wedge-locking Collector Bolts Rack Frame

Figure 2-42 Fix the Rear Pulling Rods into the Rack Frame

Hikvision DS-D4215FI-CBFC/A - Steps - 2

natural_image Technical line drawing of a multi-level metal shelving unit with no visible text or symbols

Figure 2-43 Rear Pulling Rods Fixed

  1. Use the expansion bolts to fix the rear pulling rods onto the bearing wall.

Hikvision DS-D4215FI-CBFC/A - Steps - 3

text_image Expansion Bolt Rear Pulling Rod Bearing Wall

Figure 2-44 Fix the Rear Pulling Rods onto the Bearing Wall

Install the Connectors

The connectors are divided into two parts: customized front joint piece which is used to connect the screens, and back connecting component which is used to connect the rack frame. The following figures list three types of connectors and the locating positions of the connectors respectively.

Hikvision DS-D4215FI-CBFC/A - Install the Connectors - 1

natural_image Technical line drawing of a mechanical bracket assembly (no text or symbols)

Type A Connector

Hikvision DS-D4215FI-CBFC/A - Install the Connectors - 2

natural_image Technical line drawing of a mechanical assembly with mounting flanges and bolts (no text or symbols)

Type B Connector

Hikvision DS-D4215FI-CBFC/A - Install the Connectors - 3

natural_image Technical line drawing of two mechanical components with mounting holes and bolts (no text or symbols)

Type C Connector
Figure 2-45 Connectors

Hikvision DS-D4215FI-CBFC/A - Install the Connectors - 4

text_image Type C Connector Type A Connector Type B Connector Type A Connector Type B Connector

Figure 2-46 Connectors Installed

i Note

Please pay attention to the types of outermost connectors between rack frame and bottom chassis.

Steps

  1. Twist the hexagonal screws into the screw thread plates.
  2. Insert the screw thread plates into the slots of aluminum extrusion rods, and move the connectors to the suitable place.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Screw Thread Plate Hexagonal Screws

Figure 2-47 Install the Connectors

  1. Secure the connectors to the rack frame with screws.

Install Cabinets into the Rack Frame

After the bottom chassis, rack frame and connectors are well installed, take the following steps to install the cabinets into the rack frame:

Steps

  1. Install the first cabinet from the lower middle part. Level and secure the cabinet to the connectors on the rack frame. For the screens without connectors near the rear, use joint pieces to fix the screen.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Joint Pieces

Figure 2-48 Fix the Screen with Joint Pieces

Hikvision DS-D4215FI-CBFC/A - Steps - 2

Note

• Install the cabinets from the bottom to the top, from the middle to the sides.
- Do not fix the screws between the connectors in case that cabinets are too tight for future adjustment.
- In normal cases, lock out LED lamp boards after they are adjusted horizontally or vertically as the boards will probably be moved during the installation of other lamp boards.
- Ensure that the screen is flat and there is no obvious gap between screens. Otherwise, make some adjustments.

  1. Repeat the above steps to install other cabinets in the lowest row.

Hikvision DS-D4215FI-CBFC/A - Note - 1

text_image Use joint pieces to fix the screens in the middle parts between two frame units. Use connectors to secure the screens to the rack frame.

Figure 2-49 Fix the Screens

  1. Use a level to measure and ensure that the cabinets are flat and vertical.

Hikvision DS-D4215FI-CBFC/A - Note - 2

Note

When there is a deviation in height, simply place a thin iron sheet under the bottom. Do not try to resolve the deviation by hitting the cabinets on the top because it will result in larger deviation afterwards.

  1. Repeat the above steps to complete the installation of other cabinets.

Hikvision DS-D4215FI-CBFC/A - Note - 1

text_image Screens are secured to the connector on the rack frame. Screens in the middle parts between two frame units are fixed with joint pieces.

Figure 2-50 Screens Fixed

  1. Ensure that all the cabinets are flat and vertical and the seams between the cabinets are even. Then tighten the anchor bolts to complete the installation.

Hikvision DS-D4215FI-CBFC/A - Note - 2

natural_image Technical line drawing of a multi-story industrial or warehouse structure with vertical supports and horizontal beams (no text or symbols)

Figure 2-51 Screen Installation Finished

Hikvision DS-D4215FI-CBFC/A - Note - 3

Note

  • For details about cabinet stitching, see 3.2.2 Stitch Cabinet Frames.
  • For details about lamp boards installation, see 3.2.4 Install Lamp Boards on the Cabinets.

Install the Cover Plates and Door Plates for Bottom Chassis

Steps

  1. Use T-Shaped bolts to install the front cover plates and lateral cover plates for bottom chassis respectively.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Lateral Cover Plate Front Cover Plate

Figure 2-52 Install the Cover Plates

  1. Use T-shaped bolts or door hinge to install the door plates including upper fixing plates, lower fixing plates, left door plates and right door plates.

Hikvision DS-D4215FI-CBFC/A - Steps - 2

text_image Upper Fixing Plate Lower Fixing Plate Left Door Plate Right Door Plate

Figure 2-53 Install the Door Plates

Chapter 3 Cabinet Installation

3.1 Introduction

A cabinet is a basic unit for LED engineering installation in which LED modules are neatly mounted on a metal sheet (cast aluminum) box, with a built-in independent receiving card and switching power supply, an engineering installation structure, and independent display.

3.2 Install the Cabinets

3.2.1 Precautions

Read the following precaution tips before you install the LED screens:

  • Install the LED screens after the decoration construction is completed.
  • Avoid humid or high-pH environment to prevent damage to the LED lamps.
  • Do not expose the device to rain or humid environment to reduce the risk of fire or electric shock.
  • Electric discharge may last for a short period of time after the power is shut down. Please wait two minutes after the power is shut down to operate the device.
  • Only use the original power cable delivered with the device. Contact authorized dealer to purchase power cable with same specifications.
  • Please do not frequently plug and unplug the power cable when the power is on.

3.2.2 Stitch Cabinet Frames

Before installing the cabinets, you need to stitch the cabinet frames first.

Locate Cabinet Frames

Align two cabinet frames with the locating studs and installation holes. Each cabinet frame is equipped with three locating studs and eight installation holes. Positions of the locating studs and installation holes are shown as follows.

Hikvision DS-D4215FI-CBFC/A - Locate Cabinet Frames - 1

text_image Installation Hole Locating Stud Installation Hole Locating Stud Installation Hole Locating Stud Installation Hole Installation Hole Installation Hole Installation Hole

Figure 3-1 Locating Studs and Installation Holes

Stitch Cabinet Frames Horizontally

Steps

  1. Align the installation holes in the horizontal direction of the two adjacent cabinet frames, and adjust the cabinet frames horizontally against each other.
  2. Insert M6 screws into the installation holes to lock the cabinet frames.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image M6 Screws Installation Holes

Figure 3-2 Align the Cabinet Horizontally

Hikvision DS-D4215FI-CBFC/A - Steps - 2

Note

  • You can insert the screws from left to right or from right to left according to the actual situation.
  • Adjust the flatness of the cabinet frames to ensure the horizontal and vertical alignment between the cabinet frames.

Stitch Cabinet Frames Vertically

Steps

  1. Align the locating studs vertically to the locating holes of the adjacent cabinet frame, and adjust the cabinet frames vertically against each other.
  2. Insert M6 screws into the installation holes to lock the cabinet frames.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image M6 Screws Installation Holes

Figure 3-3 Stitch Cabinet Frames Vertically

Hikvision DS-D4215FI-CBFC/A - Steps - 2

Note

  • There are five installation holes reserved for stitching the cabinet frames vertically. Stitch the cabinet frames from top to bottom.
  • Adjust the flatness of the cabinet frames to ensure the horizontal and vertical alignment between the cabinet frames.

- Four VESA holes for M8 screws are reserved on the back of the cabinet, which makes the standard bracket installation compatible.

Hikvision DS-D4215FI-CBFC/A - Note - 1

text_image Four VESA Holes for M8 Screws

Figure 3-4 Cabinet Back

3.2.3 Wiring

After the cabinet frames are stitched, connect network cables, signal lines, and power cords before further installation.

About the Cabinets

Load Capability of Network Interfaces

The load capability of a single network interface of the sending card is limited. You can calculate the max load of a single network interface by the following formula.

Max Load of a Network Interface = Pixel Capacity of a Network Interface/Cabinet Resolution

Example

If equipped with a sending card of 650,000 pixels, the max load of a single network interface for a P1.2 cabinet of 480 × 270 resolution is five cabinets.

iNote

You can choose sending cards of different pixels and cabinets of different resolution, and calculate the load capability by the formula.

Load Capability of Power Cords

The load capability of a single power cord is limited. You can calculate the max load of a single power cord by the following formula.

Max Load of a Single Power cord = Power of the Cord/Power of the Cabinet

iNote

You can choose power cords and cabinets of different specifications, and calculate the load capability by the formula.

Interfaces of Embedded Sending Card

An embedded sending card is installed at the center of each cabinet. Refer to the figure and the table below for the interfaces on the sending card.

Hikvision DS-D4215FI-CBFC/A - Interfaces of Embedded Sending Card - 1

text_image 1 2 3 4 HDMI HDBT HDMI HDBT IR USB LAN 2 LAN 1 5 6 7 8

Figure 3-5 Interfaces on Sending Card

Table 3-1 Interface Description

No.NameDescription
1HDMI INHDMI signal input
2HDBT INHDBT signal input
3HDMI OUTHDMI signal output
4HDBT OUTHDBT signal output
5IRInfrared interface
6USBUSB interface
7LAN 2LAN 2 for network access
8LAN 1LAN 1 for network access

Cabinet Cable Holes

There are five cable holes on the top and at the bottom of the cabinet frame respectively.

Hikvision DS-D4215FI-CBFC/A - Cabinet Cable Holes - 1

text_image Technical schematic diagram of an electronic device with labeled components and wiring connections

Figure 3-6 Cabinet Cable Holes

Table 3-2 Usage Suggestion for Cable Holes

No.Description
1For HDMI/HDBT cables.
2Reserved holes.
3, 4For power cords.
5For network cables/IR lines.

Connect Network Cables

iNote

The connection of network cables and signal lines should be consistent with the sending card configuration on the software client. For more details, see 4.3 Configure Signal Cables.

Steps

  1. There are eight ways to connect network cables. Choose one according to your actual needs.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

flowchart
graph TD
    A["5"] --> B["i"]
    B --> C["5"]
    C --> D["2"]
    D --> E["i"]
    E --> F["2"]
    F --> G["i"]
    G --> H["2"]
    H --> I["i"]

Figure 3-7 Network Cable Connection Mode

  1. Pull network cables through the cable holes to connect to the LAN interfaces of sending cards in different cabinets.

Hikvision DS-D4215FI-CBFC/A - Steps - 2

text_image Network Cable Connection Positions Cable Holes

Figure 3-8 Network Cable Connection

  1. Connect all cabinets in cascade.

Hikvision DS-D4215FI-CBFC/A - Steps - 3

flowchart
graph TD
    subgraph LeftPanel
        A1["LAN 2\nLAN 1"] --> B1["LAN 2\nLAN 1"]
        B1 --> C1["LAN 2\nLAN 1"]
        C1 --> D1["LAN 2\nLAN 1"]
        D1 --> E1["LAN 2\nLAN 1"]
    end
    subgraph MiddlePanel
        F1["LAN 2\nLAN 1"] --> G1["LAN 2\nLAN 1"]
        G1 --> H1["LAN 2\nLAN 1"]
        H1 --> I1["LAN 2\nLAN 1"]
        I1 --> J1["LAN 2\nLAN 1"]
    end
    subgraph RightPanel
        K1["LAN 2\nLAN 1"] --> L1["LAN 2\nLAN 1"]
        L1 --> M1["LAN 2\nLAN 1"]
        M1 --> N1["LAN 2\nLAN 1"]
        N1 --> O1["LAN 2\nLAN 1"]
    end

Figure 3-9 Network Cable Connection Diagram

iNote

This figure above takes for example.

Connect Signal Lines

Hikvision DS-D4215FI-CBFC/A - Connect Signal Lines - 1

Note

The display is stitched by 16 cabinets of 4 × 4 layout. You can stitch the cabinets and divide them into groups according to your actual needs. For example, you can divide the display into four groups of 2 × 2 layout for each group, and these groups will display images from four different signals respectively.

Steps

  1. Choose the screen splicing mode.

  2. Automatic splicing: After you set the splicing scale, the screen will be divided into groups at your settings automatically. The division will start from the screen in the upper left corner.

  3. Manual splicing: Set the splicing scale and groups manually.
  4. Pull the signal lines through the cable holes and connect to the signal input interfaces of sending cards in different cabinet groups.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image Cable Holes Line Connection Positions

Figure 3-10 Signal Line Connection

  1. Connect all cabinets. Make sure that every cabinet group is connected to a signal input and all the cabinets in one group are connected in cascade.

Hikvision DS-D4215FI-CBFC/A - Steps - 2

flowchart
graph TD
    subgraph_Group1["Input Signal of Cabinet Group 1"]
        A1["IN OUT"] --> B1["IN OUT"]
        B1 --> C1["IN OUT"]
        C1 --> D1["IN OUT"]
        D1 --> E1["IN OUT"]
    end
    subgraph_Group2["Input Signal of Cabinet Group 2"]
        A2["IN OUT"] --> B2["IN OUT"]
        B2 --> C2["IN OUT"]
        C2 --> D2["IN OUT"]
        D2 --> E2["IN OUT"]
    end
    subgraph_Group3["Input Signal of Cabinet Group 3"]
        A3["IN OUT"] --> B3["IN OUT"]
        B3 --> C3["IN OUT"]
        C3 --> D3["IN OUT"]
        D3 --> E3["IN OUT"]
    end
    subgraph_Group4["Input Signal of Cabinet Group 4"]
        A4["IN OUT"] --> B4["IN OUT"]
        B4 --> C4["IN OUT"]
        C4 --> D4["IN OUT"]
        D4 --> E4["IN OUT"]
    end
    A1 --> B1 --> C1 --> D1 --> E1 --> F1 --> G1 --> H1 --> I1 --> J1 --> K1 --> L1 --> M1 --> N1 --> O1 --> P1 --> Q1 --> R1 --> S1 --> T1 --> U1 --> V1 --> W1 --> X1 --> Y1 --> Z1 --> A2 & B2 & C2 & D2 & E2 & F2 & G2 & H2 & I2 & J2 & K2 & L2 & M2 & N2 & O2 & P2 & Q2 & R2 & S2 & T2 & U2 & V2 & W2 & X2 & Y2 & Z2 & A3 & B3 & C3 & D3 & E3 & F3 & G3 & H3 & I3 & J3 & K3 & L3 & M3 & N3 & O3 & P3 & Q3 & R3 & S3 & T3 & U3 & V3 & W3 & X3 & Y3 & Z3 & A4 & B4 & C4 & D4 & E4 & F4 & G4 & H4 & I4 & J4 & K4 & L4 & M4 & N4 & O4 & P4 & Q4 & R4 & S4 & T4 & U4 & V4 & W4 & X4 & Y4 & Z4 & A5 & B5 & C5 & D5 & E5 & F5 & G5 & H5 & I5 & J5 & K5 & L5 & M5 & N5 & O5 & P5 & Q5 & R5 & S5 & T5 & U5 & V5 & W5 & X5 & Y5 & Z5 & A6 & B6 & C6 & D6 & E6 & F6 & G6 & H6 & I6 & J6 & K6 & L6 & M6 & N6 & O6 & P6 & Q6 & R6 & S6 & T6 & U6 & V6 & W6 & X6 & Y6 & Z6 |
    end

Figure 3-11 Signal Line Connection Diagram (4 × 4)

Hikvision DS-D4215FI-CBFC/A - Steps - 3

flowchart
graph TD
    subgraph_Input_Signal_1["Input Signal of Cabinet Group 1"]
        A1["IN OUT"] --> B1["IN OUT"]
        B1 --> C1["IN OUT"]
        C1 --> D1["IN OUT"]
        D1 --> E1["IN OUT"]
    end

    subgraph_Input_Signal_2["Input Signal of Cabinet Group 2"]
        A2["IN OUT"] --> B2["IN OUT"]
        B2 --> C2["IN OUT"]
        C2 --> D2["IN OUT"]
        D2 --> E2["IN OUT"]
    end

    subgraph_Input_Signal_3["Input Signal of Cabinet Group 3"]
        A3["IN OUT"] --> B3["IN OUT"]
        B3 --> C3["IN OUT"]
        C3 --> D3["IN OUT"]
        D3 --> E3["IN OUT"]
    end

    subgraph_Input_Signal_4["Input Signal of Cabinet Group 4"]
        A4["IN OUT"] --> B4["IN OUT"]
        B4 --> C4["IN OUT"]
        C4 --> D4["IN OUT"]
        D4 --> E4["IN OUT"]
    end

    subgraph_Input_Signal_5["Input Signal of Cabinet Group 5"]
        A5["IN OUT"] --> B5["IN OUT"]
        B5 --> C5["IN OUT"]
        C5 --> D5["IN OUT"]
        D5 --> E5["IN OUT"]
    end

    subgraph_Input_Signal_6["Input Signal of Cabinet Group 6"]
        A6["IN OUT"] --> B6["IN OUT"]
        B6 --> C6["IN OUT"]
        C6 --> D6["IN OUT"]
        D6 --> E6["IN OUT"]
    end

    subgraph_Input_Signal_7["Input Signal of Cabinet Group 7"]
        A7["IN OUT"] --> B7["IN OUT"]
        B7 --> C7["IN OUT"]
        C7 --> D7["IN OUT"]
        D7 --> E7["IN OUT"]
    end

    A1 --> B1
    B1 --> C1
    C1 --> D1
    D1 --> E1
    E1 --> F1
    F1 --> G1
    G1 --> H1
    H1 --> I1
    I1 --> J1
    J1 --> K1
    K1 --> L1
    L1 --> M1
    M1 --> N1
    N1 --> O1
    O1 --> P1
    P1 --> Q1
    Q1 --> R1
    R1 --> S1
    S1 --> T1
    T1 --> U1
    U1 --> V1
    V1 --> W1
    W1 --> X1
    X1 --> Y1
    Y1 --> Z1
    Z1 --> A2
    A2 --> B2
    B2 --> C2
    C2 --> D2
    D2 --> E2
    E2 --> F2
    F2 --> G2
    G2 --> H2
    H2 --> I2
    I2 --> J2
    J2 --> K2
    K2 --> L2
    L2 --> M2
    M2 --> N2
    N2 --> O2
    O2 --> P2
    P2 --> Q2
    Q2 --> R2
    R2 --> S2
    S2 --> T2
    T2 --> U2
    U2 --> V2
    V2 --> W2
    W2 --> X2
    X2 --> Y2

Figure 3-12 Signal Line Connection Diagram (5 × 5)

iNote

- The splicing scale is recommended to be set as 4 × 4 . If you need other settings, please

contact our technical support.

  • Figures above are for reference. You can adjust the connection within each cabinet group, as long as the output interface of a cabinet is connected to the input interface of its adjacent cabinet.
  • For automatic splicing, connect the input signal from the cabinet in the upper left corner.

Connect Power Cords

Within Max. Load

If the number of cabinets is within the maximum load of the power cord, one power cord is enough to connect the cabinets.

  • Internal Connection: Pull the power cords through the cable holes and connect the power cords between two cabinets.
  • External Connection: Pull the power cords through the cable holes on the bottom of the first row of cabinets, and connect one end of the cords to the power cords in the upper cabinets and the other end to the external power supply.

Hikvision DS-D4215FI-CBFC/A - Within Max. Load - 1

text_image Connect Power Cords Cable Holes

Figure 3-13 Power Cord Connection

Beyond Max. Load

If the number of cabinets exceeds the maximum load of the power cord, you need to pull extra power cords through the reserved holes next to the original power cords and connect other cabinets in the same way.

iNote

After the power cords are connected, attach the electrical warning label next to the cable hole for external power supply at the bottom of the first row of cabinets. The label is packed with the device.

Connect Infrared Lines

Pull the infrared line through the hole on the first bottom cabinet from the left or the right.

Hikvision DS-D4215FI-CBFC/A - Connect Infrared Lines - 1

text_image Infrared Line

Figure 3-14 Infrared Connection

3.2.4 Install Lamp Boards on the Cabinets

Fix the lamp boards on the cabinet frames by magnetic attraction.

Hikvision DS-D4215FI-CBFC/A - Install Lamp Boards on the Cabinets - 1

text_image Locating Stud Connector Direction Indicator

Figure 3-15 Lamp Board

Steps

  1. Place the lamp boards on the front of the cabinet frames. Align the lamp boards and the edges of the cabinet frames.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

natural_image Technical schematic of an electrical enclosure with multiple panels and wiring (no text or labels visible)

Figure 3-16 Adsorb Lamp Board

Hikvision DS-D4215FI-CBFC/A - Steps - 2

Note

Please align the connectors and keep the arrow sign upright when adsorbing the lamp boards.

  1. Align and adsorb the lower edges of the lamp boards with the cabinet frames, and then align the locating studs on the lamp boards to the locating holes on the cabinets. Absorb the remaining three sides of the lamp boards. The lamp board adsorbs to the cabinet automatically.
  2. Optional: If you need to remove lamp boards, use LED vacuum pump to remove the first lamp board, and remove other lamp boards by hand.

Hikvision DS-D4215FI-CBFC/A - Note - 1

natural_image Technical line drawing of a mechanical device with internal components and mounting base (no text or symbols)

Figure 3-17 LED Vacuum Pump

Chapter 4 Software Debugging

4.1 Activation

The client can only control the screen when it is used in conjunction with the sending card. Please activate the corresponding sending card in the client first when using it for the first time.

Before You Start

  • The client software has been installed correctly.
    • PC and the device are in the same LAN.

Steps

  1. Run the client.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

natural_image Abstract digital globe illustration with network nodes and icons, no readable text or symbols

Hikvision DS-D4215FI-CBFC/A - Steps - 2

text_image User Login IP Address Port No User Name Password Login Remember Password Auto Login Distribution Cabinet

Figure 4-1 Client Interface

  1. Click Online Device to show all online devices in the current network segment.

Hikvision DS-D4215FI-CBFC/A - Steps - 3

text_image Online Device Total Devices(6) Refresh Device Information MAC Address Software Version Serial No 1 2 3 4 5 6 Activation Activation Activation Non-activated Activation Activation Network Parameter IP Address Port No Subnet Mask Gateway Address Password Modify Network Security Activate Reset Pass... Device Upgrade Upgrade Login Cancel

Figure 4-2 Activate Online Device

  1. Select the device to be activated and click Activate.
  2. Enter Password and confirm the password in the popup window.

Hikvision DS-D4215FI-CBFC/A - Steps - 4

text_image Activation User Name admin Password ********** Weak Valid password range [8-16]. You can use a combination of numbers, lowercase, uppercase and special character for your password with at least two kinds of them contained. Confirm Passw... ********** Apply Cancel

Figure 4-3 Activation

  1. Click Apply to activate the device.
  2. Select the activated device on Online Device interface. Modify network parameters and enter Password. Click Modify to save the modifications.

iNote

If the device network segment has DHCP function, it will allocate the IP address by default. You can skip step 6.

4.2 Login

Before any operation, you need to log in to the LED client.

Steps

  1. Run the client to enter the login interface.
  2. Enter IP Address, User Name, and Password.
  3. Click Login.
  4. Optional: Check remember password to remember the login password, so there is no need to enter password for the next login.
  5. Optional: Check Auto Login to Log into the client automatically.

4.3 Configure Signal Cables

Configure signal cables according to the actual receiving card connection between LED cabinets.

Steps

iNote

After configuring the screen scale, LED screen will show the signal cable connection. The connection of signal cables set via the client should be consistent with that of the actual screen connection.

  1. Go to the Signal Cable Configuration interface.

  2. Click Next in the Display Attribute interface.

  3. Click Basic Configuration → Signal Cable Configuration.

  4. Check Display Actual Lines on Screen. You need to connect the cable according to the position prompt on the screen.

  5. Select sending port below Please select sending port to connect.

iNote

The location prompt of each screen will indicate you to connect the signal cable. If the position prompt is 2-1, the screen is the first screen to connect to No. 2 sending port.

Hikvision DS-D4215FI-CBFC/A - iNote - 1

text_image Basic Configuration Display Attribute Signal Cable Configuration Please select sending port to connect 1 3 5 7 2 4 6 8 9 11 13 15 10 12 14 16 Line Type Custom Display Actual Lines on Screen Cancel Restore 1 2 E ← 1 Signal Backup Active Standby Network Interface Relationship 1 - 3 5 - 10 2 - 4 11 - 12 3 - 5 12 - 14 + 100 % Reset Current Port Reset All Ports OK

Figure 4-4 Signal Cable Connection

  1. Connect signal lines.

  2. Click the screen on the right side of the interface to connect signal lines.

  3. Select Line Type, and select starting port and end port on the right side of the interface.

  4. Right click on the right side of the interface after connection.

  5. Select Complete Signal Cable Connection.
  6. Click OK.

4.4 Configure Screen Splicing

You can configure splicing scale and cabinet groups via manual splicing.

Steps

  1. Go to Multi-screen Display Configuration > Manual Splicing.

Hikvision DS-D4215FI-CBFC/A - Steps - 1

text_image (1,1) Online IP: Serial No: Device Type: Resolution: 480 * 270 (1,2) Online IP: Serial No: Device Type: Resolution: 480 * 270 1 2 Sending Card Splicing Scale 1 2 Display location... Routing Mode Control No Automatic Splicing Manual Splicing Configure splice group: Delete 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Online Device dear splice IP Device T... Gui OK HideDeviceMes... Refresh

Figure 4-5 Screen Splicing Configuration

  1. Click to choose the cabinets and add them to corresponding cabinet groups.
  2. Click OK. The display will be set according to your splicing configuration.
  3. Optional: Click Delete to remove the cabinets you do not need in the cabinet groups.

Chapter 5 Installation Guide QR Code

Scan the QR code to read the installation guide online.

Hikvision DS-D4215FI-CBFC/A - Chapter 5 Installation Guide QR Code - 1

text_image HIKVISION

Figure 5-1 Installation Guide QR Code

Hikvision DS-D4215FI-CBFC/A - Chapter 5 Installation Guide QR Code - 2

See Far, Go Further

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Hikvision

Model : DS-D4215FI-CBFC/A

Category : Surveillance