USER MANUAL SC942i-600 Supermicro
natural_image
Line drawing of a server rack cabinet with multiple vertical panels and control panel (no text or labels)
natural_image
Line drawing of a multi-level rack cabinet with multiple compartments and control panel (no text or symbols)SC942S-600 SC942i-600/550
SC942 CHASSIS
INSTALLATION GUIDE
Table of Contents
Chapter I: Unpacking and Check Lists ....1-3
Chapter 2: Installation Procedures....2-1
Section 1: Installing components into the SC942 Chassis.... 2-1
A. Removing the Side Cover of the SC942 Chassis 2-1
B. Removing the SCSI Drive Trays 2-2
C. Removing the Rear Exhaust Fan and Installing the Motherboard..... 2-3
D. Removing the Components from and Installing Devices into the 5.25" Drive Bays....2-4
E. Installing the Rear Chassis Lock 2-5
F. Removing the Front Side Cover to Access the Drives 2-7
Section 2: Installing the SC942 as a Rackmount 2-9
G. Rackmount Rail Kit-CSE-PT26 2-9
H. Removing the Top Chassis Cover and Chassis Feet to install Chassis for Rackmount purpose....2-10
I. Attaching Chassis Ears to the Chassis 2-11
J. Installing Chassis Rails 2-12
K. Rack Installation 2-13
Appendix A: CSE-M35S/CSE-M35T1 Mobile Rack ...... A-1
A. Packaging List ...... A-2
B. Technical Specifications ...... A-2
Appendix B: Power Supply Specifications...... B-1
Appendix C: SCSI (Super) GEM Driver Installation Instructions for Windows OS ...... C-1
Chapter 1- Unpacking and Check Lists
1-A. The SC942S-600 chassis
The SC942S chassis contains the following:
One (1) 5.25" drive bay (for floppy drive)
Two (2) 5.25" drive bays (for peripheral drives)
Ten (10) SCA 1" drive trays
Three (3) Hot-swappable 120mm chassis fans
One (1) 120mm rear exhaust fan
The accessory box contains the following:
One set of motherboard screws
One set of drive screws
One set of HDD (hard disk drive) screws
One (1) chassis lock mechanism
Three (3) AC power cords
One (1) 30" SCSI cable (CBL-028)
One (1) 10" SCSI cable (CBL-043)

text_image
PWR On HDD Activity OH PWR Fail LAN1 LAN2 Reset Button Power Button 5.25" Expansion Bays (SC942S-600)1-B. The SC942i chassis
The SC942i chassis contains the following:
Eight (8) 5.25" peripheral drive bays
One (1) 5.25" drive bay for floppy drive
Three (3) Hot-swappable120mm chassis fans (*SC 942i-600)
Two (2) Hot-swappable120mm chassis fans (*SC 942i-550)
One (1) 120mm Rear Exhaust fan
Two (2) Front accessible USB 2.0 ports
The accessory box contains the following:
One set of motherboard screws
One set of drive screws
One set of HDD (hard disk drive) screws
One (1) chassis lock mechanism
One (1) AC power cord(*SC 942i-550)
Three (3) AC power cords(*SC 942i-600)

text_image
PWR On HDD Act OH PWR Fail LAN1 LAN2 Reset Button Power Button 5.25" Expansion Bays USB 2.0 Ports (*SC 942i only) (SC942i-600/550)Chapter 2: Installation Procedures
Section 1: Installing Components into the SC942 Chassis
A. Removing the Side Cover of the SC942 Chassis
Before installing any components, replacing chassis fans or accessing the motherboard, you will first need to remove the side cover.
Procedures
- Remove the two screws from the back lip of the side cover (-this is the left cover when you looking from the front.)

text_image
Remove the screws- Push in the release tab on the cover and push the cover back to the rear of the chassis about 1/2 inch.

text_image
Push the cover toward the rear of the chassis Push in the Release Tab- You can now lift the side cover up and off the chassis.
B. Removing the SCSI Drive Trays (\*SC942S)
Procedures
- Pull out the SCSI Drive Trays located on the front side of the chassis(*SC942S only)

text_image
Pull the SCSI Drive Trays outwards- Pull the SCSI Drive Bay outwards, and press the release tab located on the SCSI Drive Bay. Then, you can access the SCSI Drive.

text_image
Press the release tab and open the drive bay doorC. Removing the Rear Exhaust Fan and Installing the Motherboard
(You will need to remove the rear exhaust fan before you install the motherboard.)
Procedures
- Remove the side cover from the chassis (refer to Section A).
- Locate the exhaust fan tabs on the back panel (See picture below right.)
- Apply pressure to the tabs (located on the top and the bottom of the rear exhaust fan) to snap the fan out of its locked position.
- Pull the fan away from the chassis.

text_image
Rear Exhaust Fan Apply Pressure to the tabs to loosen the fan, and then, pull the fan out from the chassis.D. Removing Components from and Installing Devices into the 5.25" Drive Bays
After removing the side cover from the chassis, you can remove or install devices into the drive bays (See Section A for removing the side cover).
Procedures
- Remove the side cover to access the 5.25" drive bays.
- Remove the screws of the bay you wish to install or remove a component from. (*The chassis comes with dummy modules in all bays to maintain adequate airflow. These dummy modules should remain in the chassis until you want to add a component. Note that the top two bays are combined into a single module. To add components, you must first remove the four screws corresponding both bays.)
- After removing the screws, push the drive module out from the front of the chassis. For the floppy drive bay, you must first remove the two face plates.
- Attach the dummy rails to the new drive and insert the new drive into the bay. Secure it to the chassis with the screws you've removed. Remember to plug the data and power cables into the drive. When finished, place the chassis side cover to its place and secure it with the screws.

text_image
Remove the screwsE. Installing the Rear Chassis Lock
Follow the procedures listed below to install the Rear Chassis Lock.
Procedures
- Locate the hole at the right bottom corner of the rear side of the chassis. Also locate the lock bracket included in your shipping package.

text_image
Hole for the lock bracket lock bracket- Insert the lock bracket into the hole (*See above) and secure the lock bracket onto the chassis by putting flat screws on holes on the top and bottom of the lock bracket hole as shown below:

text_image
Holes for the screws lock bracket screws- Slide the side cover back to the proper position. Make sure that the lock bracket is easily accessible from the rear of the chassis.

natural_image
Line drawing of a server rack unit with an inset close-up showing internal components (no text or symbols)Lock Bracket
- Secure the system by putting a lock(*not included) on the lock bracket as shown below:

natural_image
Line drawing of a server rack with an inset close-up showing internal components (no text or symbols)Lock (*Not included)
F. Removing the Front Side Cover to Access the Drives
(You do not need to remove the front bezel to access the drives. We do not recommend removing the front cover unless you need to access the control panel circuit board or the floppy drive.)
Procedures
- Remove the side cover from the chassis (See Section A).
- Push on the three tabs located inside the bottom side lip of the front chassis cover.

natural_image
Technical line drawing of a server rack unit with internal components and ventilation ducts (no text or labels)- Locate the 4 notches inside the side lip. Use a flat screw driver to loose the notches and gently pry open the cover until the cover is out about 1/3 inches.

text_image
Notches Push the tabs toward the lip and pry loose the no the room. When found, located / Off and both werePush the tabs toward the lip and pry loose the notches to release the cover. When freed about 1/3", push the cover to other side of the chassis to completely release it.
- Push on the open side of cover to completely remove it from the chassis. (*Do not swing or pull the front cover straight out after opening the left side.)
- You can also remove the control panel's circuit board by removing the screw that fastens the control panel to the chassis.

natural_image
Technical line drawing of a server rack cabinet with visible internal components and mounting feet (no text or labels)Section 2: Installing the SC942 as a Rackmount
G. Rackmount Rail Kit: CSE-PT26
(* CSE-PT26 Sold separately.)
CSE-PT26 Rackmount kit (*For beige chassis), or
CSE-PT26 (B) Rackmount kit(*For black chassis)
Two (2) handle sets for rackmount chassis
Two (2) rack rail assemblies
Two (2) front brackets for mounting rack rails
Two (2) rear brackets for mounting rack rails
One (1) set of mounting screws
H. Removing the Top Chassis Cover and Chassis Feet to Install as Rackmount
Procedures
- Remove the side cover from the chassis (See Section A).
- Press the release tab in the center of the cover lip while pushing the cover toward the rear of the chassis at the same time. After the cover stops, lift it off.

text_image
Press the Release Tab- Each chassis foot has a single screw. Remove the screw, then, depress the foot's locking tab from inside of the chassis. Slide the foot off.

text_image
Push the cover Chassis FeetI. Attaching Chassis Ears to the Chassis
After you have removed chassis feet from the chassis, you can now attach chassis ears to the chassis.
Procedures
- Remove the chassis feet from the chassis (See Section H).
- Locate a pair of chassis ears and two sets of screws (3-each set) included in the shipping package, and lay the chassis on a flat level as shown below.

text_image
Screws Chassis Ears Screws- Align the chassis ears against the top and the bottom of the chassis as shown above. Then, properly attach chassis ears to the chassis by tightening the screws provided as shown above.

natural_image
Line drawing of a server rack unit with front panel and rear panel (no text or symbols)SC942 Chassis with Chassis Ears attached
J. Installing Chassis Rails
After you have attached the chassis ears to the chassis, you can install chassis rails to the chassis for rackmount purpose.
Procedures
- Included in the shipping package are a pair of rail assemblies. In each rail assembly, locate the inner rail and the outer rail.

text_image
Press the Locking Tab Outer rail (*to be installed in the rack) Pull out the Inner rail (*to be attached on the chassis) Rail Assembly- Press the locking tab to release the inner rail from its locking position and pull out the inner rail from the rail assembly. (*The inner rails are to be attached to the chassis and the outer rails are to be installed in the rack.)
- Attach the inner rail to one side of the chassis as shown below. Repeat Steps 2 and 3 to attach another inner rail to the other side of the chassis.

text_image
Attach the Inner rail to the chassis Chassis ears Inner railK. Rack Installation
After you have installed the inner rails and chassis ears to the chassis, you are ready to install the outer rails of rail assemblies to the rack.
Procedures
- In the package, locate a pair of short brackets, and a pair of long brackets. Please note that there are "R"(-Right) and "L"(-Left) marked on the short and long brackets. Use the short bracket marked with "R" for the outer rail that is going to be installed on the right side of the chassis (when facing the front panel of the chassis.) However, use the long bracket marked with "L" on the rear side of the same outer rail that you are going to install on the right side of the chassis (since you are facing the rear panel).
- Align the holes on one of the short bracket against the holes located on the front of the outer rail. Secure the short bracket to the front side of the outer rail by putting two M4 screws through the bracket and the slide. (*Be sure to adjust the distance between the long and short brackets so that the outer rail can snugly fit into the depth of the racks before you tighten the screws.)
- Align the holes on one of the long bracket against the holes located on the rear side of the outer rail. Secure the long bracket to the rear side of the outer rail by putting three M4 screws through the bracket and the slide. (*Be sure to adjust the distance between the long and short brackets so that the outer rail can snugly fit into the depth of the racks before you tighten the screws.)
- Repeat the same steps for the other outer rail.

text_image
Outer Rail Rear side Long Bracket Front side Short Bracket Put two M4 Screws through the bracket and the outer rail Put three M4 Screws through the bracket and the outer rail- Align brackets flush against the racks and tighten two screws through the holes of the rack (as shown below) and repeat the same step to install the rack on the other side.

text_image
M5 screws and to attach the to the rack.-
Once both outside rails are securely installed on the rack, you are ready to mount the SC942 to the rack.
-
To mount the SC942 on the rack, first you need to align both of the inner slides that are attached on the SC942 against the outer rails as shown below:

text_image
Outer rails Inner rails-
Slide the SC942 Assemblies all the way to the back of the slide rails to ensure that the assemblies are securely latched on the ball bearing slides. (The SC942 may not slide in smoothly or easily into the rack when installed the first time. However, some adjustment to the slide assemblies might be needed for easy installation.)
-
Secure the SC942 by tightening the screws on the sides of the SC942 as shown above.

text_image
screwsAppendix A
CSE-M35S/CSE-M35T1
Mobile Rack

natural_image
Technical line drawing of a server rack unit with multiple ports and ventilation slots (no text or symbols)User's Guide
Rev. 1.0
CSE-M35S/CSE-M35T1
Supermicro's CSE-M35S/CSE-M35T1 Mobile Rack Series offers the cutting edge technology with greater flexibility. The CSE-M35T1 supports five Serial ATA hot-swappable hard drives that yield a unparalleled storage capacity without compromising productivity by eliminating possible system downtime. The CSE-M35S also accommodates five SCSI SCA 320/160 Hard drives which provide configuration flexibility and maximum data integrity.
A. Packing List
Please check to see if you have received all the items listed below:
*CSE-M35S/CSE-M35T1 Mobile Rack
*90mm-Exhaust Fan (Fan-0057)
*Screws: Flat Head Screws (13)
Round Head Screws (24)
Round Head Screws with Lock-Washer (7)
*Drive Carrier CSE-PT17/CSE-PT17(B)(-black) (5)
(*For CSE-M35T1 only)
*Serial ATA Backplane (CSE-SATAM35)
*(5)Serial ATA Cables (CBL-0044)
*Serial ATA LED cable (CBL-0057)
(*For CSE-M35S only)
*SCSI Backplane (CSE-SCAM942)
*SCSI cable (CBL-027-U320)
B. Technical Specifications
| Occupancy | Three (3) 5.25" Drive Bays |
| Capacity | Five (5) 1" SCA Ultra320/160 Hard Drives with SAF-TE built-in (*CSE-M35S only)Five (5) 1" Host Receptacle Connectors, SATA hot-swap hard drives (*CSE-M35T-1 only) |
| Cooling Subsystem | One (1) 9cm Exhaust Fan |
| System Monitoring | Fan Fail Detection LED and AlarmOverheat LED indicationDrive Fail Alarm and Indication (*CSE-M35S only)Built-in Termination (*CSE-M35S only) |
| Dimension (WxHxD) | 146mm x 129mm x 245mm(5.7 in x 5.0 in x 9.6 in) |
| Weight | Net: 5.9lb (2.9 kg), Gross: 7.5lb (3.7 kg) |
Chassis supported:
SC762, SC830, SC942
C. Jumper Settings
C-1. Jumper Settings for the CSE-M35S (SCSI):
| Jumper | Description Setting | |
| JP18 | Buzzer Reset | Closed: Enable,Open: Disable (*Default) |
| JP21 SCSI Termination Closed: Enable (*Default),Open: Disable | ||
| JP24 SCSI ID Selection 1-2: SCSI | Ids: 0,1,2,3,4 (*Default),2-3: SCSI Ids: 9,10,11,12,13 | |
| JP29 GE M 318 IDs 1-2: ID6 (*Default),2-3: ID8 | ||
| JP30 Fan Sense Pins 1-2: Enable | (*Default) (If a fan is not present, the alarm will sound.),Pins 2-3: Disable | |
Location of Jumpers

text_image
JP21 JP30 JP29 Pin 1 Pin 1 FAN Pin 1 Pin 1 JP25 ON: EWP OPEN 52°C 1-2 55°C 2-3 62°C JP24: SCS ID SELECT 1-2/SCS ID=0.1/2.6/4 2-3/SCS ID=0.10/11, 12/13 JP1A: DELAY START JP21: SCS TERM ON WITH TERM. OFF AND TERM. SUPERX® SCAM942 IN REV 1.00 Pin 1 JP24 JP18C-2. Jumper Settings for the CSE-M35T1 (SATA):
| Jumper | Description Setting | |
| JP18 | Buzzer Reset | Closed: Enable,Open: Disable (*Default) |
| JP25 | Overheat Temperature | Open: 45°C1-2: 50°C (*Default),2-3: 55°C |
| JP26 | Act#1-Act#5 | Connect this header to CBL-0057(SATA LED Cable) |
| JP28: | Fan Sense | 1-2: Enabled (if a fan is not present,the alarm will sound) (*Default)2-3: Disabled |
Location of Jumpers

text_image
SUPER-SATAM35 Channel #1 Channel #2 Channel #3 Channel #4 Channel #5 Channel #6 Channel #7 Channel #8 Channel #9 Channel #10 Channel #11 Channel #12 Channel #13 Channel #14 Channel #15 Channel #16 Channel #17 Channel #18 Channel #19 Channel #20 Channel #21 Channel #22 Channel #23 Channel #24 Channel #25 Channel #26 JP26 Key COM ACT8 ACT4 ACT7 ACT3 ACT6 ACT2 ACT5 ACT1 Activity LEDs- Pin Definitions Act. LED 1 Channel 1 Act. LED 2 Channel 2 Act. LED 3 Channel 3 Act. LED 4 Channel 4 Act. LED 5 Channel 5D. Installation Procedures
D-1. Accessing Hot Swappable Drives:
- Push the release button located beside the drive LEDs (as shown below:)

natural_image
Technical line drawing of a computer tower case with multiple ventilation slots and mounting holes (no text or symbols)- Swing the handle outward and pull out the unit (as shown below:)

natural_image
Technical line drawing of a multi-chamber electronic device with an open panel and internal components, showing assembly steps (no text or symbols)- Mount a drive in a carrier (as shown below:)

flowchart
graph LR
A["Step 1: Initial component"] --> B["Step 2: Assembly with curved cutout"]
B --> C["Step 3: Final assembled device"]
D-2. Accessing the Exhaust Fan:
- Push the tabs located on both sides of the unit (as shown below:)

natural_image
Technical line drawing of a computer drive casing with fan and mounting bracket (no text or symbols)- Pull out the fan (as shown below:)

natural_image
Technical line drawing of a computer case with fan assembly, showing internal components and mounting bracket (no text or symbols)(*Note: For the SC-942 Chassis, the CSE-M35 Rear Exhaust Fan should not be used. Instead, the hot-swappable 120mm Chassis Fans included with the SC-942 Chassis should be connected to the Backplane of the CSE-M35S/CSE-M35T1 Mobile Rack.)
D-3. Accessing the Drive Backplane:
- Unscrew the screw located on the side of the unit (as shown below:)

natural_image
Technical line drawing of a computer oven with visible internal components and ventilation slots (no text or symbols)- Pull out the Rear Bracket (as shown below:)

natural_image
Technical line drawing of a computer oven with internal fan and ventilation slots (no text or symbols)- Access the Backplane (as shown below:)

natural_image
Technical line drawing of a computer tower case with internal components and an external panel showing internal structure (no text or symbols)Appendix B
Power Supply Specifications
Please refer to the following table for Power Supply Specifications:
| Power Supply Spec SC942S-600 SC942i-600 SC942i-550 | |||
| Model # SP602-TS SP602-TS SP550-RP | |||
| Part # PWS-044 PWS-044 PWS-046 | |||
| Rated AC Input Voltage | 100-240V AC 100-240V AC 100-240V AC | ||
| Rated Input Frequency | 50-60 Hz 50-60 Hz 50-60 Hz | ||
| Rated Input Current 12A (115V) 12A (115V) 9A (115V) | |||
| 6A (230V) 6A (230V) 4.5A (230V) | |||
| Rated Output Power | 600W 600W 550W | ||
| Maximum rated BTU | 3240 BTUs/Hr | 3240 BTUs/Hr | 2800 BTUs/Hr |
| Nominal DC Output | |||
| +3.3V | 36A | 36A | 30A |
| +5V | 30A | 30A | 30A |
| +12V | 24A | 24A | 26A |
| -5V | 0.8A | ||
| -12V | 1A | 1A | 0.8A |
| +5Vsb | 2A | 2A | 2.0A |
Notes
Appendix C
SCSI (Super) GEM Driver Installation Instructions for Windows OS
Please refer to the following instructions to install the SCSI GEM Driver for the Windows OS systems.
(*Note: This driver is not necessary for other Operating Systems.)
If you have two SCA backplanes, you will need to install the driver twice. The driver is located on the Super Micro motherboard driver CD or is available for download from our FTP site: ftp://ftp.supermicro.com/driver/Qlogic/
Follow the procedure below to install this driver to your system.
Installing the driver:
1) Right click on "My Computer" and choose "Property".
2) Select "Hardware" tab and click on "Device Manager".
3) Open "Other Devices" or wherever "GEM318" is on.
4) Right click on this device and choose "Property".
5) Click on "Driver" tab and choose "Update Driver".
6) Click "Next" 2 times, uncheck both "Floppy disk drives" and "CD-ROM drives". Then, select the item- "Specify a location," and choose "Next".
7) Click on "Browse" and choose D drive or wherever Supermicro Setup CD is in.
8) Choose "Qlogic" folder and click on "Open".
9) System will automatically detect GEM318 and install the drive from this point on.
or,
1) Right click the "My Computer" icon on your desktop and choose Properties.
2) Click on the Hardware tab and click on "Device Manager" to bring up the list of system devices.
3) You may see one or two yellow question marks (?) that read QLogic GEM354 or GEM318 SCSI Processor Device. Right click on these, and choose to uninstall. If two such question marks are present, uninstall both.
4) Click on Action tab and choose "Scan for Hardware Changes". The Hardware Wizard program should start up. Click "Next".
5) At the first prompt, choose "Display a list of known device drivers for the device so that I can choose a specific driver" and click "Next".
6) Choose "Other Devices" and click Next.
7) Choose "Have Disk", and specify your floppy drive location in the options box. Then, click "Next".
8) Highlight "Enclosure Services Device" and click "Next".
9) Ignore the warning prompt by clicking "Yes".