SuperServer 5019A-FTN10P - Server Supermicro - Free user manual and instructions
Find the device manual for free SuperServer 5019A-FTN10P Supermicro in PDF.
User questions about SuperServer 5019A-FTN10P Supermicro
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Server in PDF format for free! Find your manual SuperServer 5019A-FTN10P - Supermicro and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SuperServer 5019A-FTN10P by Supermicro.
USER MANUAL SuperServer 5019A-FTN10P Supermicro
natural_image
Front view of a network equipment rack with ports, connectors, and a supermic device (no visible text or symbols)USER'S MANUAL
Revision 1.0
The information in this User's Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our website at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL Super Micro Computer, Inc. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO COMPUTER, INC. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer's instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate".

WARNING: This product can expose you to chemicals including lead, known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and proceedings of any kind arising out of or related to such ultra-hazardous use or sale.
Manual Revision 1.0
Release Date: April 03, 2019
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2019 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
Preface
About this Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 5019A-FTN10P. Installation and maintenance should be performed by experienced technicians only.
Please refer to the 5019A-FTN10P server specifications page on our website for updates on supported memory, processors, and operating systems (http://www.supermicro.com).
Notes
For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user's manual for your server.
• Supermicro product manuals: http://www.supermicro.com/support/manuals/
- Product drivers and utilities: https://www.supermicro.com/wftp/driver
- Product safety info: http://www.supermicro.com/about/policies/safety_information.cfm
If you have any questions, contact our support team at:
support@supermicro.com
This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level.
Warnings
Special attention should be given to the following symbols used in this manual.

Warning! Indicates important information given to prevent equipment/property damage or personal injury.

Warning! Indicates high voltage may be encountered when performing a procedure.
Contents
Chapter 1 Introduction
1.1 Overview....8
1.2 Unpacking the System 8
1.3 System Features 9
1.4 Server Chassis Features....10
Control Panel 10
Front Features....11
1.5 Motherboard Layout....12
Quick Reference Table....13
Chapter 2 Server Installation
2.1 Overview....16
2.2 Preparing for Setup....16
Choosing a Setup Location....16
Rack Precautions....16
Server Precautions....17
Rack Mounting Considerations....17
Ambient Operating Temperature....17
Airflow 17
Mechanical Loading....18
Circuit Overloading....18
Reliable Ground....18
2.3 Installing the System into a Rack....19
Installing the Chassis into a Rack....19
Chapter 3 Component Installation and Maintenance
3.1 Removing Power....20
3.2 Accessing the System....20
3.3 Motherboard Components....22
Installing Memory 22
Memory Support....22
DIMM Installation....23
DIMM Removal....23
Motherboard Battery ....24
3.4 Chassis Components ....25
Hard Drives ....25
Installing 3.5" Fixed Hard Drives....26
Installing 2.5" Fixed Hard Drives....27
Expansion Card....28
System Cooling....29
System Fan Failure ....29
Checking the Chassis Airflow....30
Power Supply 30
Chapter 4 Motherboard Connections
4.1 Power Connections ....32
4.2 Headers and Connectors ....34
Control Panel 39
4.3 Ports 42
4.4 Jumpers....44
Explanation of Jumpers....44
4.5 LED Indicators....47
Chapter 5 Software
5.1 Microsoft Windows OS Installation....48
5.2 Driver Installation....50
5.3 SuperDoctor ^® 5....51
5.4 IPMI....52
Chapter 6 UEFI BIOS
6.1 Introduction....53
6.2 Main Setup ....54
6.3 Advanced Setup Configurations....56
6.4 Event Logs ....78
6.5 IPMI 80
6.6 Security....83
6.7 Boot....87
6.8 Save & Exit....89
Appendix A BIOS Codes
Appendix B UEFI BIOS Recovery
Appendix C System Specifications
Appendix D Standardized Warning Statements for AC Systems
Appendix E Standardized Warning Statements (Traditional Chinese)
Appendix F Dual Boot Block
Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Website: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Website: www.supermicro.nl
Asia-Pacific
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3992
Email: support@supermicro.com.tw
Website: www.supermicro.com.tw
Chapter 1
Introduction
1.1 Overview
This chapter provides a brief outline of the functions and features of the 5019A-FTN10P. The 5019A-FTN10P is based on the A2SDV-8C-LN10PF motherboard and the SC505-203B chassis.
In addition to the motherboard and chassis, several important parts that are included with the system are listed below.
| Main Parts List | ||
| Description Part Number Quantity | ||
| Riser Card RSC-RR1U-E8 1 | ||
| System Fans (third fan is optional) FAN-0065L4 2 | ||
| Fan Holder MCP-320-81302-0B 3 | ||
| I/O Shield MCP-260-00135-0N 1 | ||
| Rack Mount Kit (optional) MCP-290-50404-0N 1 | ||
| Single 2.5" fixed HDD Bracket MCP-220-00051-0N 2 | ||
| Dual 2.5" fixed HDD Bracket* (optional) | MCP-220-00044-0N | 2 |
*Note: Required for configurations with four 2.5" HDDs.
1.2 Unpacking the System
Inspect the box that the SuperServer 5019A-FTN10P was shipped in and note if it was damaged in any way. If any equipment appears damaged, file a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the server. It should be situated in a clean, dust-free area that is well-ventilated. Avoid areas where heat, electrical noise, and electromagnetic fields are generated. A grounded AC power outlet is also required. Read the precautions and considerations noted in Appendix D.
1.3 System Features
The following table provides an overview of the main features of the 5019A-FTN10P. Refer to Appendix C for additional specifications.
| System Features |
| Motherboard |
| A2SDV-8C-LN10PF |
| Chassis |
| SC505-203B |
| CPU |
| Intel Atom processor C3758 |
| Socket Type |
| FCBGA1310 |
| Memory |
| Supports up to 256GB of ECC RDIMM or 64GB of ECC/non-ECC UDIMM DDR4 memory in four DIMM slots |
| Chipset |
| Intel Atom SoC chipset |
| Expansion Slots |
| One PCI Express 3.0 x4 slotsTwo M.2 PCI Express 3.0 x2 slots (1 x M-Key 2242/2280, 1 x B-Key 3042/2280) |
| Hard Drives |
| Up to two 3.5" or four 2.5" hard-disk drives |
| Power |
| 200W Low Noise AC-DC power supply module with PFC (p/n PWS-203-1H) |
| Form Factor |
| 1U rackmount |
| Dimensions |
| (WxHxD) 17.2 x 1.7 x 9.8 in. (437 x 43 x 249 mm) |
1.4 Server Chassis Features
Control Panel
The switches and LEDs located on the control panel are described below. The control panel is located next to the left handle of the chassis. See Chapter 4 for details on the control panel connections.

text_image
i 2 1 灯 RESET 1Figure 1-1. Control Panel View
| Control Panel Features | ||
| Item Feature Description | ||
| 1 Power Button | The main power button is used to apply or remove power from the power supply to the server. Turning off system power with this button removes the main power but maintains standby power. To perform maintenance tasks, you must also unplug the system before servicing. | |
| 2 Reset Button The reset button is used | to reboot the system. | |
| 3 Power LED | Indicates power is being supplied to the system power supply. This LED should normally be illuminated when the system is operating. | |
| 4 HDD LED Indicates hard drive activity when flashing. | ||
| 5 | NIC1 LED | Indicates network activity on LAN port 1 when flashing. |
| 6 | NIC2 LED | Indicates network activity on LAN port 2 when flashing. |
| 7 Information LED | Indicates one of multiple conditions. Refer to the following table for more information. | |
| Information LED | |
| Status Description | |
| Continuously on and red | An overheat condition has occurred (possibly caused by cable congestion). |
| Blinking red (1Hz) Fan failure. Check for an inoperative fan. | |
| Blinking red (0.25Hz) Power supply failure. | |
| Solid blue | Local UID is active. Use this function to identify the server in a rack mount environment. |
| Blinking blue | Remote UID is active. Use this function to identify the server from a remote location. |
Front Features
The SC505-203B is a 1U chassis. See the illustration below for the features included on the front of the chassis.

text_image
① ② ③ ④ SUPERMIX®Figure 1-2. Chassis Front View
| Front Chassis Features | ||
| Item Feature | Description | |
| 1 Control Panel | Front control panel with LEDs and buttons (see preceding page) | |
| 2 I/O Front Panel | Front I/O ports (see Section 4.3) | |
| 3 PCI-E Expansion | Slot Slot for PCI-E expansion card | |
| 4 Expansion | Card Clip Clip for cover of PCI-E expansion slot | |
| 5 Rack Ear | Brackets Secures the server chassis to the rack | |
1.5 Motherboard Layout
Below is a layout of the A2SDV-8C-LN10PF with jumper, connector, and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information, and jumper settings, refer to Chapter 4.

text_image
JPG1 SLOT6 USB2/3 eUSB SRW2 COM1 JD1 JWD1 JMD2 JIPMB1 JTPM1 JI2C1 JI2C2 I-SATA1 I-SATA2 I-SATA3 I-SATA4 SRW4 JMD1 JLANLED2 JLANLED1 JLANLED3 JPH1 JSFPLED1 JFPCLED1 JBR1 JL1 FANB JPL2 JPL3 JPL4 UIDLED1 JUIDB VGA SFP1 LAN1-2 VGA LAN3-10 IPMI LAN USB0/1 (3.1 Gen 1) JPL1 IPMI LAN USB X1 (3.1 Gen 1) JGP1 JSMB1 JPME2 JPI2C1 JBT1 JSD1 JSEL1 BT1 I-SATA0 JMD2 JPW1 SRW3 JPV1 FAN1 SAPTORA A2SDV-8C-LN10PF REV: 01 DESIGNED IN USA CPU ALWAYS POR LATE DIMMA FRS1 JPN2 DIMMA2 DIMMA1 DIMMB2 DIMMB1 USB4 (3.1 Gen 1)Figure 1-3. Motherboard Layout
Note: Components not documented are for internal testing only.
Quick Reference Table
Jumper Description Default Setting
| JBR1 BIOS Recovery Pins 1-2 (Normal) | ||
| JBT1 CMOS Clear Open (Normal) | ||
| JI2C1, JI2C2 SMB to PCI-E Slots Enable/Disable Pins 2-3 (Disabled) | ||
| JPG1 Onboard VGA Enable/Disable Pins 1-2 (Enabled) | ||
| JPL1 LAN1 SFP Port Enable/Disable Pins 1-2 (Enabled) | ||
| JPL2 LAN2 SFP Port Enable/Disable Pins 1-2 (Enabled) | ||
| JPL3 LAN3-6 Ports Enable/Disable Pins 1-2 (Enabled) | ||
| JPL4 LAN7-10 Ports Enable/Disable Pins 1-2 (Enabled) | ||
| JPME2 | ME Manufacturing Mode | Pins 1-2 (Normal) |
| JSEL1 | PCI-E Slot 6/7 Selection | Pins 1-2: Slot 7 |
| JWD1 | Watch Dog Timer | Pins 1-2 (Reset) |
| LED Description | Status | |
| LED1 Power LED | Solid Green: Power On | |
| LEDM1 | BMC Heartbeat | Blinking Green: BMC Normal |
| UIDLED1 | UID LED | Solid Blue: Unit Identified |
| Connector | Description |
| BT1 | Onboard Battery |
| COM1 | COM Header |
| FAN1 - FAN3, FANA, FANB | CPU/System Fan Headers |
| IPMI LAN | IPMI LAN Port |
| I-SATA0-4 | SATA 3.0 Ports |
| JD1 | Speaker (Pins 1-4) |
| JF1 | Front Control Panel Header |
| JFPCLED1 | RJ45 LAN LED Board Cable Connector for FPB-FPE300-LED10 |
| JGP1 | General Purpose I/O Header |
| JIPMB1 | System Management Bus Header (for IPMI card) |
| JL1 | Chassis Intrusion Header |
| JLANLED1 | LAN3-6 Activity LED |
| JLANLED2 | LAN7-8 Activity LED |
| JLANLED3 | LAN9-10 Activity LED |
| JMD1 | M.2 B-Key PCI-E3.0/SATA3.0/USB3.0 Slot |
| JMD2 | M.2 M-Key PCI-E3.0/SATA3 Slot |
Connector Description
| JPI^2C1 Power Supply SMBus I | ^2C Header |
| JPH1 4-pin Power Connector for HDD use | |
| JPW1 24-pin ATX Power Connector | |
| JPV1 | 4-pin 12V DC Power Connector (To provide alternative power for a special enclosure when the 24-pin ATX power is not in use.) |
| JRT3 Thermal Diode 1 | |
| JRT4 Thermal Diode 2 | |
| JSD1 SATA DOM Power Connector | |
| JSFPLED1 SFP LAN LED Board Cable Connector for FPB-FPE300-LED10 | |
| JSMB1 System Management Bus Header | |
| JTPM1 Trusted Platform Module (TPM) | |
| JUIDB Unit ID Button | |
| LAN1 - LAN10 LAN1-2 Gigabit Ethernet SFP Port, LAN3-10 Gigabit Ethernet RJ45 Port | |
| SLOT6, SLOT7 Single PCI-E Expansion Slot (Slot6 or Slot7 selectable with JSEL1)PCI-E 3.0 x4 | |
| SRW1 - SRW4 M.2 Holding Screws | |
| USB0/1 Back Panel USB 3.1 Gen 1 Ports | |
| USB2/3 Front Accessible USB 2.0 Header | |
| USB4 USB 3.1 Gen 1 Type A Header | |
| VGA | VGA Port |

flowchart
graph TD
A["BMC AST2400"] -->|USB 2.0["0"]| B["CPU"]
A -->|LPCHSIO["14"], PCIE X1| C["VR13"]
A -->|RTL8211F| D["GIGALAN"]
A -->|TPM Header| E["TPM Header"]
A -->|VGA| F["VGA"]
A -->|FAN X5| G["FAN X5"]
A --> H["CPLD 1.CMXO2-1.20CHC"]
A --> I["COM1 HEADER"]
A --> J["RTL8211F"]
A --> K["RJ45"]
A --> L["PCIE X4 SLOT 6 (OPTION)"]
A --> M["PCIE X4 SLOT 7"]
M --> N["PCIe 3.0_x4 8GT/s"]
M --> O["PCIe 3.0_x2 (8GT/s)"]
M --> P["SATA 3.0 x1 (6GT/s)"]
M --> Q["5X SATA-III"]
Q --> R["SATA-III 6Gb/s"]
M --> S["M.2 2242/2280 M KEY PCIE/SATA SSD"]
M --> T["M.2 3042/2280 B KEY PCIE/SATA SSD USB 3.0/2.0"]
M --> U["PCIe 3.0_x2 (8GT/s)"]
M --> V["SATA 3.0 x1 (6GT/s)"]
A --> W["HSIO[3:0"], PCIE x4]
A --> X["HSIO[5:4"], PCIE x2]
A --> Y["HSIO[9/11/15/16/17"], SATA III]
A --> Z["HSIO[7:6"], PCIE x2]
A --> AA["HSIO[12:11"], PCIE x2]
A --> AB["HSIO[18"], USB 3.0 USB2.0["2"]]
A --> AC["HSIO[19"], USB 3.0 USB2.0["3"]]
A --> AD["KR X4"]
A --> AE["RSU 3.0 x1 USB 2.0 x1"]
A --> AF["RSU 3.0 x1 USB 2.0 x1"]
A --> AG["RSU 3.0 x1 USB 2.0 x1"]
A --> AH["RSU 3.0 x1 USB 2.0 x1"]
A --> AI["RSU 3.0 x1 USB 2.0 x1"]
A --> AJ["RSU 3.0 x1 USB 2.0 x1"]
A --> AK["RSU 3.0 x1 USB 2.0 x1"]
A --> AL["RSU 3.0 x1 USB 2.0 x1"]
A --> AM["RSU 3.0 x1 USB 2.0 x1"]
A --> AN["RSU 3.0 x1 USB 2.0 x1"]
A --> AO["RSU 3.0 x1 USB 2.0 x1"]
A --> AP["RSU 3.0 x1 USB 2.0 x1"]
A --> AQ["RSU 3.0 x1 USB 2.0 x1"]
A --> AR["RSU 3.0 x1 USB 2.0 x1"]
A --> AS["RSU 3.0 x1 USB 2.0 x1"]
A --> AT["RSU 3.0 x1 USB 2.0 x1"]
A --> AU["RSU 3.0 x1 USB 2.0 x1"]
A --> AV["RSU 3.0 x1 USB 2.0 x1"]
A --> AW["RSU 3.0 x1 USB 2.0 x1"]
A --> AX["RSU 3.0 x1 USB 2.0 x1"]
A --> AY["RSU 3.0 x1 USB 2.0 x1"]
A --> AZ["RSU 3.0 x1 USB 2.0 x1"]
A --> BA["RSU 3.0 x1 USB 2.0 x1"]
A --> BB["RSU 3.0 x1 USB 2.0 x1"]
A --> BC["RSU 3.0 x1 USB 2.0 x1"]
A --> BD["RSU 3.0 x1 USB 2.0 x1"]
A --> BE["RSU 3.0 x1 USB 2.0 x1"]
A --> BF["RSU 3.0 x1 USB 2.0 x1"]
A --> BG["RSU 3.0 x1 USB 2.0 x1"]
A --> BH["RSU 3.0 x1 USB 2.0 x1"]
A --> BI["RSU 3.0 x1 USB 2.0 x1"]
A --> BJ["RSU 3.0 x1 USB 2.0 x1"]
A --> BK["RSU 3.0 x1 USB 2.0 x1"]
A --> BL["RSU 3.0 x1 USB 2.0 x1"]
A --> BM["RSU 3.0 x1 USB 2.0 x1"]
A --> BN["RSU 3.0 x1 USB 2.0 x1"]
A --> BO["RSU 3.0 x1 USB 2.0 x1"]
A --> BP["RSU 3.0 x1 USB 2.0 x1"]
A --> BQ["RSU 3.0 x1 USB 2.0 x1"]
A --> BR["RSU 3.0 x1 USB 2.0 x1"]
A --> BS["RSU 3.0 x1 USB 2.0 x1"]
A --> BT["RSU 3.0 x1 USB 2.0 x1"]
A --> BU["RSU 3.0 x1 USB 2.0 x1"]
A --> BV["RSU 3.0 x1 USB 2.0 x1"]
A --> BW["RSU 3.0 x1 USB 2.0 x1"]
A --> BX["RSU 3.0 x1 USB 2.0 x1"]
A --> BY["RSU 3.0 x1 USB 2.0 x1"]
A --> BZ["RSU 3.0 x1 USB 2.0 x1"]
Figure 1-4. System Block Diagram
Note: This is a general block diagram and may not exactly represent the features on your motherboard. See the System Specifications appendix for the actual specifications of your motherboard.
Chapter 2
Server Installation
2.1 Overview
This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory, etc., refer to Chapter 4 for details on installing those components.
Caution: Electrostatic Discharge (ESD) can damage electronic components. To prevent such damage to PCBs (printed circuit boards), use a grounded wrist strap, handle all PCBs by their edges, and keep them in anti-static bags when not in use.
2.2 Preparing for Setup
The box in which the system was shipped includes the screws needed to install the server into a rack. Read this section in its entirety before you begin the installation.
Choosing a Setup Location
- The system should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise, and electromagnetic fields are generated.
- Leave at least 25 inches of clearance in front of the rack so that you can open the front door completely. Leave approximately 30 inches of clearance behind the rack to allow sufficient space for airflow and access when servicing.
- This product should be installed only in a Restricted Access Location (dedicated equipment rooms, service closets, etc.).
- This product is not suitable for use with visual display workplace devices according to §2 of the German Ordinance for Work with Visual Display Units.
Rack Precautions
- Verify that the leveling jacks on the bottom of the rack are extended to the floor so that the full weight of the rack rests on them.
- In single-rack installations, stabilizers should be attached to the rack. In multi-rack installations, the racks should be coupled together.
- Always verify that the rack is stable before extending a server or other component from the rack.
- You should extend only one server or component at a time. Extending two or more simultaneously might cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Appendix D.
- Determine the placement of each component in the rack before you install the rails.
- Install the heaviest server components at the bottom of the rack first. Subsequent components should be installed in decreasing order of weight with the lightest component at the top.
- Use a regulating uninterruptible power supply (UPS) to protect the server from power surges and voltage spikes and to keep your system operating in case of a power failure.
- Allow any drives and power supply modules to cool before touching them.
- When not servicing, always keep the front door of the rack and all covers and panels closed to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment might be greater than the room's ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer's maximum rated ambient temperature (TMRA).
Airflow
Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).

To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
- This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
- When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.
- If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack.

Mounted equipment is not to be used as a shelf or a work space.

Warning: Do not pick up the server with the front handles. They are designed to pull the system from a rack only.
2.3 Installing the System into a Rack
This section provides information on installing the 505-203B chassis into a rack unit. Due to the variety of rack units on the market, the assembly procedure might differ slightly. Also refer to the installation instructions that came with the rack unit you are using.
Installing the Chassis into a Rack
The system can be directly installed into a rack using screws.
- Gather the four mounting screws shipped with the system.
-
Align the mounting holes of the chassis with the through-holes of the rack.
-
Insert the mounting screws into the through-holes in the front of the chassis, and tighten the screws until the chassis is secured to the rack.

natural_image
Technical line drawing of a mechanical assembly with a conical component inserted into a housing (no text or symbols)Figure 2-1. Installing the Chassis into a Rack

Warning: Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over.
Chapter 3
Component Installation and Maintenance
This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and part numbers given.
Remove power from the system and remove the top cover before installing or replacing components. Refer to Section 3.1 and Section 3.2.
3.1 Removing Power
Use the following procedure to verify that power has been removed from the system. This step is required when removing or installing non hot-swap components or when replacing a non-redundant power supply.
- Use the operating system to power down the system.
- After the system has fully shut down, disconnect the AC power cord(s) from the power strip or outlet. (If your system has more than one power supply, remove the AC power cords from all power supply modules.)
- Disconnect the power cord(s) from the power supply module(s).
3.2 Accessing the System
The SC505-203B features a removable top cover, which allows easy access to the inside of the chassis.
Removing the Top Cover
- Remove power from the system as described in Section 3.1.
- Remove the screws securing the cover to the chassis (two on each side, one on the rear).
- Lift the cover off the chassis.
Warning: Except for short periods of time, do not operate the server without the cover in place. The chassis cover must be in place to allow for proper airflow and to prevent overheating.

natural_image
Technical diagram of a server rack with internal components and directional arrows indicating assembly (no text or labels)Figure 3-1. Removing the Chassis Cover
3.3 Motherboard Components
Installing Memory
Memory Support
The A2SDV-8C-LN10PF supports up to 256GB of ECC RDIMM or 64GB of Non-EC/ECC UDIMM DDR4 memory in four DIMM slots. Refer to the table below for additional memory information.
| Memory Population (Balanced) | ||||
| DIMMA1 | DIMMB1 | DIMM | MA2 DIMMB2 | Total System Memory |
| 4GB 4GB | 8GB | |||
| 4GB 4GB | 4GB 4GB | 16GB | ||
| 8GB 8GB | 16GB | |||
| 8GB 8GB | 8GB 8GB | 32GB | ||
| 16GB 16GB | 32GB | |||
| 16GB 16GB | 16GB 16GB | 64GB | ||
| 32GB 32GB | 64GB | |||
| 32GB 32GB | 32GB 32GB | 128GB | ||
| 64GB 64GB | 128GB | |||
| 64GB 64GB | 64GB 64GB | 256GB | ||
DIMM Installation
Begin by removing power from the system as described in Section 3.1 and removing the cover as described in Section 3.2.
- Insert DIMM modules in the following order: DIMMA1, DIMMB1, DIMMA2, DIMMB2. For the system to work properly, use memory modules of the same type and speed.
- Push the release tabs outwards on both ends of the DIMM slot to unlock it.
- Align the key of the DIMM module with the receptive point on the memory slot.
- Align the notches on both ends of the module against the receptive points on the ends of the slot.
- Seat the module firmly into the slot, pushing down evenly on both sides of the module until it snaps into place.
- Press the release tabs to the lock positions to secure the DIMM module into the slot.
DIMM Removal
Press both release tabs on the ends of the DIMM module to unlock it. Once the DIMM module is loosened, remove it from the memory slot.

natural_image
Technical illustration of a mechanical component with a highlighted section and label 'Notches' (no readable text or symbols beyond label)
text_image
Release Tabs
text_image
Press both ends straight down into the memory slot.Figure 3-3. Installing DIMMs
Note: Visit the product page on the Supermicro website for possible updates to memory support (www.supermicro.com).
Motherboard Battery
The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard.
Replacing the Battery
Begin by removing power from the system as described in Section 3.1 and removing the cover as described in Section 3.2.
- Using a tool such as a small screwdriver, push the battery lock outwards. Once unlocked, the battery pops out from the holder.
- Remove the battery.
- To insert a new battery, slide one edge under the lip of the holder with the positive (+) side facing up. Then, push the other side down until the clamp snaps over it.
Warning: There is a danger of explosion if the onboard battery is installed upside down (which reverses its polarities). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032).

text_image
LITHIUM BATTERY BATTERY HOLDER OR LITHIUM BATTERY BATTERY HOLDERFigure 3-4. Installing the Onboard Battery
Note: Handle used batteries carefully. Do not damage the battery in any way. A damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly.
3.4 Chassis Components
Hard Drives
The chassis supports up to two 3.5" or four 2.5" HDDs, and one PCI-E expansion card. The following configurations are supported:
• One 3.5" HDD and a low-profile PCI-E expansion card.
- Two 3.5" HDDs and no expansion card.
- Two 2.5" HDDs and a full-height, half-length PCI-E expansion card.
- Four 2.5" HDDs and no expansion card. (Requires dual 2.5" fixed HDD bracket. Refer to the parts list table in Section 1.1.)
Installing 3.5" Fixed Hard Drives
You can install one 3.5" HDD and a PCI-E expansion card, or you can install two 3.5" HDDs and no expansion card.
Installing 3.5" Hard Drives
Begin by removing power from the system as described in Section 3.1 and removing the cover as described in Section 3.2.
- Place the hard drives into the chassis as illustrated in Figure 3-5 or Figure 3-6. Orient the drives with the cable connections facing the rear of the chassis.
- Secure the drives to the chassis floor by inserting the screws upward through the underside of the chassis.
- Connect the drive wiring.
- Reinstall the chassis cover and restore power to the server.

natural_image
Technical line drawing of a server rack with internal components and mounting bracket (no text or symbols)Figure 3-5. One 3.5" HDD and One Low-Profile Expansion Card

text_image
Technical diagram of an internal server rack with labeled components and structural annotationsFigure 3-6. Two 3.5" HDDs and No Expansion Card
Installing 2.5" Fixed Hard Drives
You can install between one and four 2.5" HDDs in various configurations. If two or fewer 2.5" HDDs are installed, you can also add a full-height, half-length PCI-E expansion card.
If you want to install four 2.5" HDDs, two dual 2.5" fixed HDD brackets are required. Refer to the parts list table in Section 1.1.
Installing 2.5" Hard Drives
Begin by removing power from the system as described in Section 3.1 and removing the cover as described in Section 3.2.
-
Install the hard drives into the hard drive brackets and secure them with the screws provided.
-
Place the hard drives and brackets into the chassis as illustrated in Figure 3-7 or Figure 3-8. Orient two or more drives with the cable connections facing the inside of the chassis.
-
Secure the hard drive brackets to the chassis floor by inserting the screws upward through the underside of the chassis.
-
Connect the hard drive wiring.
-
Reinstall the chassis cover and restore power to the server.

natural_image
Technical line drawing of a server rack with internal components and mounting hardware (no text or symbols)Figure 3-7. Two 3.5" HDDs and One Full-Height, Half-Length Expansion Card

text_image
Technical diagram of a server rack with labeled components and an arrow indicating assembly or connectionFigure 3-8. Four 2.5" HDDs in Two Brackets, No Expansion Card
Expansion Card
The chassis supports one PCI-E expansion card installed with one 3.5" or two 2.5" HDDs. Refer to the supported configurations list in Section 3.4.
Only install expansion cards after the HDDs are installed.
Installing an Expansion Card
Begin by removing power from the system as described in Section 3.1 and removing the cover as described in Section 3.2.
- Locate the expansion card clip on the front of the chassis. Remove the screws holding the expansion card clip and the shield that covers the PCI-E slot opening in the chassis.
- Remove the expansion card clip and the PCI-E slot cover from the chassis.
- Outside the chassis, insert the expansion card into the riser card.
- Insert the riser card into the expansion slot on the motherboard while aligning the PCI-E slot bracket of the expansion card into the open PCI-E slot in the chassis.

text_image
Riser Card Expansion Card Clip PCI-E Slot Cover Riser Card SlotFigure 3-9. Expansion Card and Riser Card
- Replace the expansion card clip and screw it onto the chassis to hold the expansion card in place.
- Reinstall the chassis cover and restore power to the server.
System Cooling
Up to three fans provide cooling for the system (third fan is optional). The chassis top cover must be installed properly and form a tight seal so that the cooling air can circulate properly through the chassis.
System Fan Failure
Fan speed is controlled by system temperature via IPMI. Replace any failed fan with the same type and model.
Replacing Fans
Begin by removing power from the system as described in Section 3.1 and removing the cover as described in Section 3.2.
- Disconnect the fan power cable from the motherboard and remove the broken fan.
- Replace the failed fan with an identical 4028mm 13K RPM 4-pin PWM fan (available from Supermicro).
-
Position the new fan into the space vacated by the failed fan previously removed. An audible click indicates that the fan is fully installed.
-
Reconnect the fan cables to the motherboard.
-
Reinstall the chassis cover and restore power to the server.

text_image
Dual Fans Single FanFigure 3-10. Installing System Fans
Checking the Chassis Airflow
- Verify that no objects or wires are obstructing airflow into or out of the server.
- Only use recommended server parts.
- The control panel LED indicates if a fan has failed. Refer to Section 1.4.
Power Supply
The SC505 chassis includes a single 200W power supply module. The power supply module has an auto-switching capability that enables it to automatically sense and operate at a 100V - 240V input voltage.
If the power supply module fails, the system shuts down and you must replace the module. Replacement units can be ordered directly from Supermicro.
Replacing the Power Supply
Begin by removing power from the system as described in Section 3.1 (even if the server is offline) and removing the cover as described in Section 3.2.
- Disconnect all wires from the power supply.
- Remove the four mounting screws that hold the power supply in the chassis. There are two rear mounting screws and two underside mounting screws.
- Remove the power supply from the chassis.
- Align the mounting through-holes on the new power supply with the mounting holes in the chassis. Reattach the power supply to the chassis using the four mounting screws.
- Reconnect all wires to the power supply, replace the cover, and restore power to the server.

text_image
Mounting Through-Holes Power Supply Module Rear Mounting Screws Insert Bottom Mounting Screws from UndersideFigure 3-11. Replacing the Power Supply
Chapter 4
Motherboard Connections
This section describes the connections on the motherboard and provides pinout definitions. Depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. A motherboard layout indicating component locations can be found in Chapter 1.
Review the Safety Precautions in Appendix D before installing or removing components.
4.1 Power Connections
Three power connections on the A2SDV-8C-LN10PF must be connected to the power supply. The wiring is included with the power supply.
Main ATX Power Supply Connector
The primary power supply connector (JPW1) meets the ATX SSI EPS 12V specification.
Important: To provide adequate power to the motherboard, connect the 24-pin and the 4-pin power connectors to the power supply. Failure to do so may void the manufacturer's warranty on your power supply and motherboard.
| ATX Power 24-pin Connector Pin Definitions | ||
| Pin# Definition Pin# Definition | ||
| 13 +3.3V 1 +3.3V | ||
| 14 -12V 2 +3.3V | ||
| 15 Ground 3 Ground | ||
| 16 PS_ON 4 +5V | ||
| 17 Ground 5 Ground | ||
| 18 Ground 6 +5V | ||
| 19 Ground 7 Ground | ||
| 20 Res (NC) 8 PWR_OK | ||
| 21 +5V 9 5VSB | ||
| 22 +5V 10 +12V | ||
| 23 +5V 11 +12V | ||
| 24 Ground 12 +3.3V | ||
12V DC Power Connector
The 4-pin (JPV1) connector is used to provide alternative power for a special enclosure when the 24-pin ATX power is not in use.
| +12V 4-pin Power Pin Definitions | |
| Pin# | Definition |
| 1-2 Ground | |
| 3-4 +12V | |

HDD Power Connector
JPH1 is a 4-pin power connector for HDD use. It provides power from the motherboard to the onboard HDD.
| 4-pin HDD Power Pin Definitions | |
| Pin# | Definition |
| 1 +12V | |
| 2-3 Ground | |
| 4 +5V | |

4.2 Headers and Connectors
Fan Headers
The A2SDV-8C-LN10PF has three 4-pin fan headers (FAN1-3). These headers are backward compatible with the traditional 3-pin fans. However, fan speed control is available for 4-pin fans only by Thermal Management via the IPMI 2.0 interface. Refer to the table below for pin definitions.
| Fan HeaderPin Definitions |
| Pin# Definition |
| 1 Ground (Black) |
| 2 2.5A/+12V (Red) |
| 3 Tachometer |
| 4 PWM_Control |
Speaker Header
JD1 is the speaker header. Connect the cable of the external speaker to pins 1-4.
| Speaker ConnectorPin Definitions | |
| Pin Setting Definition | |
| Pins 1-4 Speaker |
Chassis Intrusion
A Chassis Intrusion header is located at JL1 on the motherboard. Attach the appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened. Refer to the table below for pin definitions.
| Chassis Intrusion Pin Definitions |
| Pin# Definition |
| 1 Intrusion Input |
| 2 Ground |
General Purpose I/O Header
JGP1 is a 10-pin general purpose I/O header. Each pin can be configured to be an input or output pin. The GPIO is controlled via the PCA9554 8-bit GPIO expansion. The base address is 0xF040(D31:F4).
| JGP1 HeaderPin Definitions | ||
| Pin# Definition | ||
| 1 +5V | +5V | |
| 2 Ground Ground | ||
| 3 GP0 | GPP_E0 | |
| 4 GP1 | GPP_F1 | |
| 5 GP2 | GPP_E1 | |
| 6 GP3 | GPP_F2 | |
| 7 GP4 | GPP_E2 | |
| 8 GP5 | GPP_F3 | |
| 9 GP6 | GPP_F0 | |
| 10 GP7 | GPP_F4 | |
Disk On Module Power Connector
The Disk-On-Module (DOM) power connector at JSD1 provides 5V power to a solid-state DOM storage device connected to one of the SATA ports. Refer the table below for pin definitions.
| DOM Power Pin Definitions | |
| Pin# Definition | |
| 1 +5V | |
| 2 Ground | |
| 3 Ground | |
System Management Bus Header
A System Management Bus header for additional slave devices or sensors is located at JSMB1. See the table below for pin definitions.
| SMBus HeaderPin Definitions | |
| Pin# Definition | |
| 1 Data | |
| 2 Ground | |
| 3 Clock | |
| 4 NC | |
BMC External I2C Header
A System Management Bus header for IPMI 2.0 is located at JIPMB1. Connect the appropriate cable here to use the IPMB I²C connection on your system. Refer to the table below for pin definitions.
| External I2C Header Pin Definitions | |
| Pin# Definition | |
| 1 Data | |
| 2 Ground | |
| 3 Clock | |
| 4 NC | |
Power SMB (I²C) Header
The Power System Management Bus ( I^2C ) connector (JPI ^2 C1) monitors the power supply, fan, and system temperatures. Refer to the table below for pin definitions.
| Power SMB Header Pin Definitions | |
| Pin# Definition | |
| 1 Clock | |
| 2 Data | |
| 3 PMBUS_Alert | |
| 4 Ground | |
| 5 NC |
TPM/Port 80 Header
A Trusted Platform Module (TPM)/Port 80 header is located at JTPM1 to provide TPM support and a Port 80 connection. Use this header to enhance system performance and data security. Refer to the table below for pin definitions.
| Trusted Platform Module HeaderPin Definitions | ||
| Pin# Definition Pin# Definition | ||
| 1 LCLK 2 GND | ||
| 3 LFRAME# 4 No Pin | ||
| 5 LRESET# 6 +5V (X) | ||
| 7 LAD3 8 LAD2 | ||
| 9 +3.3V 10 LAD1 | ||
| 11 LAD0 12 GND | ||
| 13 SMB_CLK (X) 14 SMB_DAT (X) | ||
| 15 P3V3_STBY 16 SERIRQ | ||
| 17 GND 18 LPC_CLKRUN (X) | ||
| 19 SUS_STAT_N 20 | LDRQ# (X) | |

text_image
20 20 19 2 1SATA Ports
Five SATA 3.0 ports (I-SATA0/1/2/3/4) are available.
| SATA 3.0 PortPin Definitions | |
| Pin# Signal | |
| 1 Ground | |
| 2 SATA_TXP | |
| 3 SATA_TXN | |
| 4 Ground | |
| 5 SATA_RXN | |
| 6 SATA_RXP | |
| 7 Ground |
M.2 B-Key
JMD1 is a B-key connector supporting a PCI-E 3.0 x2/SATA/USB device in 3042 or 2280 lengths.


text_image
Press in here Rectangle hole on MB Hole Location on the MB 42 M.2 Card 60 A+B+C M.2 Card 80 A+B+C M.2 Card 110 A+B+D A+B+C A+B+D Copyright © 2017 by Super Micro Computer, Inc. All rights reserved.M.2 M-Key
JMD2 is a M-key connector supporting a PCI-E 3.0 x2/SATA device in 2042 or 2280 lengths.
Thermal Diode Headers
JRT3 is the thermal diode 1 header, and JRT4 is the thermal diode 2 header. They are thermal sensor headers that provide additional system temperature monitoring.
| Thermal Diode 1Pin Definitions |
| Pin# Definition |
| 1 TD1 P |
| 2 TD1 N |
| Thermal Diode 2Pin Definitions |
| Pin# Definition |
| 1 TD1 P |
| 2 TD1 N |
LAN Port Activity LED
JLANLED1
Activity LED for LAN ports 3/4/5/6.
JLANLED2
Activity LED for LAN ports 7/8.
JLANLED3
Activity LED for LAN ports 9/10.
Front RJ45 Link and Activity LED Header
JFPCLED1 is the 1GbE RJ45 link and activity LED header. Attach a cable from this header to the Supermicro LED board (Part Number: FPB-FPE300-LED10) to display the status of the RJ45 LAN link and activity LED.
Front SFP Link and Activity LED Header
JSPFLED1 is the 1GbE SFP link and activity LED header. Attach a cable from this header to the Supermicro LED board (Part Number: FPB-FPE300-LED10) to display the status of the SFP link and activity LED.
Control Panel
JF1 contains header pins for various buttons and indicators that are normally located on a control panel at the front of the chassis. These connectors are designed specifically for use with Supermicro chassis. See the figure below for the descriptions of the front control panel buttons and LED indicators.

text_image
PWR Power Button Reset Reset Button 3.3V UID LED 3.3V Stby 3.3V Stby 3.3V Stby 3.3V X NMI 19 20 Ground Ground Power Fail LED OH/Fan Fail LED LAN2 Activity LED LAN1 Activity LED HDD LED PWR LED X GroundFigure 4-1. JF1: Control Panel Pins
Power Button
The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be configured to function as a suspend button (with a setting in the BIOS - see Chapter 4). To turn off the power when the system is in suspend mode, press the button for 4 seconds or longer. Refer to the table below for pin definitions.
| Power ButtonPin Definitions (JF1) |
| Pin# Definition |
| 1 Signal |
| 2 Ground |
Reset Button
The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset switch on the computer case. Refer the table below for pin definitions.
| Reset ButtonPin Definitions (JF1) |
| Pin# Definition |
| 3 Reset |
| 4 Ground |
Power Fail LED
Connect an LED cable to Power Fail connections on pins 5 and 6 of JF1 to provide warnings for a power failure. Refer to the table below for pin definitions.
| Power Indicator Status |
| Pin# Definition |
| 5 +3.3V |
| 6 PWR Fail |
Overheat (OH)/Fan Fail
Connect an LED cable to pins 7 and 8 to use the Overheat/Fan Fail LED connections. The LED on pin 8 provides warnings of overheat or fan failure. Refer to the tables below for pin definitions.
| OH/Fan Fail Indicator Status | |
| State Definition | |
| Off Normal | |
| On Overheat | |
| Flashing Fan Fail | |
| OH/Fan Fail LEDPin Definitions (JF1) | |
| Pin# Definition | |
| 7 UID | LED |
| 8 OH/Fan Fail LED | |
LAN1/LAN2 Activity LED
The LAN LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN port 2 is on pins 9 and 10. Attach the NIC LED cables here to display network activity. Refer to the table below for pin definitions.
| LAN1/LAN2 LEDPin Definitions (JF1) |
| Pin# Definition |
| 9 3.3V Stby |
| 10 LAN2 Active LED |
| 11 3.3V Stby |
| 12 LAN1 Active LED |
HDD LED
The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable to show hard drive activity status. Refer to the table below for pin definitions.
| HDD LEDPin Definitions (JF1) |
| Pin# Definition |
| 13 +3.3V |
| 14 HDD LED |
Power LED
The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table below for pin definitions.
| Power LEDPin Definitions (JF1) |
| Pin# Definition |
| 15 +3.8V |
| 16 PWR LED |
NMI Button
The non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table below for pin definitions.
| NMI ButtonPin Definitions (JF1) |
| Pin# Definition |
| 19 NMI |
| 20 Ground |
4.3 Ports

text_image
1 2 3 4 5 6 7 8 9 10 11 12 13 14 Figure 4.3 H2 PortsFigure 4-2. I/O Ports
| Rear I/O Ports | |||
| # Description # | Description | ||
| 1. | IPMI LAN | 8. | LAN8 |
| 2. | USB1 | 9. | LAN7 |
| 3. | USB0 | 10. | LAN10 |
| 4. | LAN4 | 11. | LAN9 |
| 5. | LAN3 | 12. | LAN2 |
| 6. | LAN6 | 13. | LAN1 |
| 7. | LAN5 | 14. | VGA |
VGA Port
A VGA port is located on the I/O back panel. Use this port to connect to a compatible VGA display.
LAN Ports
There are 10 LAN ports on the motherboard. LAN1-2 support two SFP connectors and LAN3-10 support eight RJ45 connectors. The motherboard also offers one IPMI LAN port.
COM Header
The motherboard has one COM header for front access to provide a serial connection.
| COM HeaderPin Definitions | |||
| Pin# Definition Pin# Definition | |||
| 1 DCD | 6 DSR | ||
| 2 RXD | 7 RTS | ||
| 3 TXD | 8 CTS | ||
| 4 DTR | 9 RI | ||
| 5 Ground | 10 N/A | ||
Universal Serial Bus (USB) Ports
There are three USB 3.1 Gen 1 Type-A (USB0/1 rear and USB4 header) and one USB 2.0 header (USB2/3). The onboard header can be used to provide front side USB access with a cable (not included). USB 3.1 Gen 1 is also referred to as USB 3.0.
| Type A USB 3.1 Gen 1 Pin Definitions | |
| Pin# Definition | |
| 1 VBUS | |
| 2 D- | |
| 3 D+ | |
| 4 Ground | |
| 5 StdA_SSRX- | |
| 6 StdA_SSRX+ | |
| 7 GND_DRAIN | |
| 8 StdA_SSTX- | |
| 9 StdA_SSTX+ | |
| USB 2.0 Header (USB2/3)Pin Definitions | ||
| Pin# Definition Pin# Definition | ||
| 1 +5V | 2 +5V | |
| 3 USB_N | 4 USB_N | |
| 5 USB_P | 6 USB_P | |
| 7 Ground | 8 Ground | |
| 9 Key | 10 NC | |
Unit Identifier Button/UID LED Indicator
A Unit Identifier button and an LED indicator are located on the motherboard. The UID button (JUIDB) is located next to the VGA port on the back panel. The UID LED is located at UIDLED1, next to the UID button. When you press the UID button, the UID LED will be turned on. Press the UID button again to turn off the LED indicator. The LED indicator provides easy identification of a system unit that may be in need of service.
Note: UID can also be triggered via IPMI on the motherboard. For more information on IPMI, please refer to the IPMI User's Guide posted on our website at https://www.supermicro.com/support/manuals/.
| UID ButtonPin Definitions | |
| Pin# Definition | |
| 1 Ground | |
| 2 Ground | |
| 3 Button In | |
| 4 Button In |
| UID LEDPin Definitions |
| Color Status |
| Blue: On Unit Identified |
4.4 Jumpers
Explanation of Jumpers
To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit board. See the diagram below for an example of jumping pins 1 and 2. Refer to the motherboard layout page for jumper locations.
Note: On two-pin jumpers, Closed means the jumper is on and Open means the jumper is off the pins.

text_image
Connector Pins Jumper Setting 3 2 1 3 2 1CMOS Clear
JBT1 is used to clear the CMOS. Instead of pins, this jumper consists of contact pads to prevent accidental clearing of the CMOS. To clear the CMOS, use a metal object such as a small screwdriver to touch both pads at the same time to short the connection.
Note: Shut down the system and then short JBT1 to clear the CMOS.

JBT1 contact pads
LAN Port Enable/Disable
JPL1
Use JPL1 to enable/disable LAN1 SFP port.
JPL2
Use JPL1 to enable/disable LAN2 SFP port.
JPL3
Use JPL3 to enable/disable LAN3-6 RJ45 ports.
JPL4
Use JPL4 to enable/disable LAN7-10 RJ45 ports.
| LAN Enable/DisableJumper Settings |
| Jumper Setting Definition |
| Pins 1-2 Enabled (Default) |
| Pins 2-3 Disabled |
Watch Dog
JWD1 controls the Watch Dog function. Watch Dog is a monitor that can reboot the system when a software application hangs. Jumping pins 1-2 will cause Watch Dog to reset the system if an application hangs. Jumping pins 2-3 will generate a non-maskable interrupt signal for the application that hangs. Watch Dog must also be enabled in the BIOS. The default setting is Reset.
Note: When Watch Dog is enabled, users need to write their own application software to disable it.
| Watch DogJumper Settings | |
| Jumper Setting Definition | |
| Pins 1-2 Reset (Default) | |
| Pins 2-3 NMI | |
| Open Disabled | |
SMBus to PCI Slots
Jumpers JI^2C1 and JI^2C2 allow you to connect the System Management Bus ( I^2C ) to the PCI-E slots. Both jumpers must be set to the same setting (JC1 controls the clock and JI^2C2 controls the data).
| SMBus to PCI SlotsJumper Settings | |
| JfC1 Setting JI | ^2 C2 Setting Definition |
| JfC1: Pins 1-2 JI | ^2 C2: Pins 1-2 Enabled |
| JfC1: Pins 2-3 JI | ^2 C2: Pins 2-3 Disabled (Default) |
Manufacturing Mode Select
Close pins 2-3 of jumper JPME2 to bypass SPI flash security and force the system to operate in the manufacturing mode, which will allow the user to flash the system firmware from a host server for system setting modifications. Refer to the table below for jumper settings.
| Manufacturing ModeJumper Settings | |
| Jumper Setting Definition | |
| Pins 1-2 Normal | (Default) |
| Pins 2-3 Manufacturing Mode | |
VGA Enable/Disable
Use jumper JPG1 to enable or disable the onboard VGA connector. Refer to the table below for jumper settings.
| VGA Enable/DisableJumper Settings | |
| Jumper Setting Definition | |
| Pins 1-2 Enabled (Default) | |
| Pins 2-3 Disabled |
BIOS Recovery
Close pins 2-3 of jumper JBR1 for BIOS recovery. The default setting is on pins 1 and 2 for normal operation. Refer to the table below for jumper settings. The default setting is Normal.
| BIOS RecoveryJumper Settings | |
| Jumper Setting Definition | |
| Pins 1-2 Normal | |
| Pins 2-3 BIOS Recovery | |
PCI-E Slot Selection
Use jumper JSEL1 to select between PCI-E 3.0 x4 slot 6 or slot 7. Only one PCI-E slot can be used at a time.
| PCI-E Slot SelectionJumper Settings | |
| Jumper Setting Definition | |
| Pins 1-2 Slot 7 (Default) | |
| Pins 2-3 Slot 6 | |
4.5 LED Indicators
LAN LEDs
Eight RJ45 LAN ports and two SFP LAN ports are located on the I/O back panel. Each Ethernet LAN port has two LEDs. One LED indicates activity, while the other Link LED may be green, amber, or off to indicate the speed of the connection. Refer to the tables below for more information. When the system is in the S1/S3/S4/S5 states, the LAN Link LED will be in the solid on state.
| Activity Indicator | |
| Color Status Definition | |
| Off No Connection | |
| Yellow Flashing Active | |
| 1G RJ45 LAN Link | |
| Color Definition | |
| Off No Connection or 10 Mb/s | |
| Green 100 Mb/s | |
| Amber 1 Gb/s |

| 1G SFP LAN Link LED (LAN9 - LAN10) | |
| Color Definition | |
| Off No Connection | |
| Amber 1G | |

text_image
Link LED Activity LED| Activity Indicator | |
| Color Status Definition | |
| Off No Connection | |
| Yellow Flashing Active | |
Power LED
LED1 is an onboard power LED. When this LED is lit, it means power is present on the motherboard. In suspend mode, this LED will blink on and off. Be sure to turn off the system and unplug the power cord(s) before removing or installing components.
| Onboard Power LED Indicator | |
| Color Definition | |
| Off | System Off(power cable not connected) |
| Green System | On |
BMC Heartbeat LED
LEDM1 is the BMC heartbeat LED. When the LED is blinking green, BMC is working. Refer to the table below for the LED status.
| BMC Heartbeat LED Indicator | |
| Color Definition | |
| BlinkingGreen | BMC Normal |
Chapter 5
Software
After the hardware has been installed, you can install the Operating System (OS), configure RAID settings and install the drivers.
5.1 Microsoft Windows OS Installation
If you will be using RAID, you must configure RAID settings before installing the Windows OS and the RAID driver. Refer to the RAID Configuration User Guides posted on our website at www.supermicro.com/support/manuals.
Installing the OS
- Create a method to access the MS Windows installation ISO file. That might be a DVD, perhaps using an external USB/SATA DVD drive, or a USB flash drive, or the IPMI KVM console.
- Retrieve the proper RST/RSTe driver. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities", select the proper driver, and copy it to a USB flash drive.
- Boot from a bootable device with Windows OS installation. You can see a bootable device list by pressing F11 during the system startup.

text_image
Please select boot device: ATEN Virtual CDROM YSOJ → IPMI virtual drive (Legacy) ASUS SDRW-08D2S-U F601 → USB DVD device (Legacy) USB FLASH DRIVE PMAP → USB flash drive with OS installation (Legacy) IBA 40-10G Slot 1900 v1060 → PXE boot (Legacy) UEFI: ATEN Virtual CDROM YSOJ → IPMI virtual drive (UEFI) UEFI: ASUS SDRW-08D2S-U F601 → USB DVD device (UEFI) UEFI: Built-in EFI Shell Enter Setup ↑ and ↓ to move selection ENTER to select boot device ESC to boot using defaults- During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on "Load driver" link at the bottom left corner.

text_image
Where do you want to install Windows? Name Total size Free space Type Refresh Delete Format New Load driver Extend We couldn't find any drives. To get a storage driver, click Load driver. NextFigure 5-2. Load Driver Link
To load the driver, browse the USB flash drive for the proper driver files.
- For RAID, choose the SATA/sSATA RAID driver indicated then choose the storage drive on which you want to install it.
-
For non-RAID, choose the SATA/sSATA AHCI driver indicated then choose the storage drive on which you want to install it.
-
Once all devices are specified, continue with the installation.
- After the Windows OS installation has completed, the system will automatically reboot multiple times.
5.2 Driver Installation
The Supermicro website contains drivers and utilities for your system at https://www.supermicro.com/wftp/driver. Some of these must be installed, such as the chipset driver.
After accessing the website, go into the CDR_Images (in the parent directory of the above link) and locate the ISO file for your motherboard. Download this file to a USB flash drive or a DVD. (You may also use a utility to extract the ISO file if preferred.)
Another option is to go to the Supermicro website at http://www.supermicro.com/products/. Find the product page for your motherboard, and "Download the Latest Drivers and Utilities". Insert the flash drive or disk and the screenshot shown below should appear.

text_image
SUPERMICRO A2SDV-4C-LN8F Motherboard Drivers & Tools (Win10) Intel C3000 Chipset A2SDV-4C/ 8C-LN8F/LN10F SUPERMICRO Computer Inc. Intel Chipset INF files Microsoft .Net Framework (Optional) ASPEED Graphics Driver Intel USB 3.0 Drivers Intel PRO Network Connections Drivers Trusted Platform Module Driver (Optional) SUPERMICRO SuperDoctor 5 Build driver diskettes and manuals Browse CD Auto Start Up Next Time For more information, please visit SUPERMICRO's web site.Figure 5-1. Driver & Tool Installation Screen
Note: Click the icons showing a hand writing on paper to view the readme files for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After installing each item, you must re-boot the system before moving on to the next item on the list. The bottom icon with a CD on it allows you to view the entire contents.
5.3 SuperDoctor® 5
The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs. With SuperDoctor 5 Management Server (SSM Server), you can remotely control power on/off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI. SuperDoctor 5 Management Server monitors HTTP, FTP, and SMTP services to optimize the efficiency of your operation.
Note: The default User Name and Password for SuperDoctor 5 is ADMIN / ADMIN.

text_image
SuperDoctor 5 Home info: www.humanlab.com Certificate error: localhost:1044/superdoctor SuperDoctor 5 Select Language: English (ADMIN) Language Motherboard: C78366-CB-ML Voltage 0.0V 12.0V 14.0V 16.0V 18.0V 20.0V 22.0V 24.0V 26.0V 28.0V 30.0V 32.0V 34.0V 36.0V 38.0V 40.0V 42.0V 44.0V 46.0V 48.0V 50.0V 52.0V 54.0V 56.0V 58.0V 60.0V 62.0V 64.0V 66.0V 68.0V 70.0V 72.0V 74.0V 76.0V 78.0V 80.0V 82.0V 84.0V 86.0V 88.0V 90.0V 92.0V 94.0V 96.0V 98.0V 100.0V 102.0V 104.0V 106.0V 108.0V 110.0V 112.0V 114.0V 116.0V 118.0V 120.0V 122.0V 124.0V 126.0V 128.0V 130.0V 132.0V 134.0V 136.0V 138.0V 140.0V 142.0V 144.0V 146.0V 148.0V 150.0V 152.0V 154.0V 156.0V 158.0V 160.0V 162.0V 164.0V 166.0V 168.0V 170.0V 172.0V 174.0V 176.0V 178.0V 180.0V 182.0V 184.0V 186.0V 188.0V 190.0V 192.0V 194.0V 196.0V 198.0V 200.0V 202.0V 204.0V 206.0V 208.0V 210.0V 212.0V 214.0V 216.0V 218.0V 220.0V 222.0V 224.0V 226.0V 228.0V 230.0V 232.0V 234.0V 236.0V 238.0V 240.0VFigure 5-4. SuperDoctor 5 Interface Display Screen (Health Information)
5.4 IPMI
The A2SDV-8C-LN10PF supports the Intelligent Platform Management Interface (IPMI). IPMI is used to provide remote access, monitoring and management. There are several BIOS settings that are related to IPMI.
For general documentation and information on IPMI, please visit our website at: http://www.supermicro.com/products/nfo/IPMI.cfm.
Chapter 6
UEFI BIOS
6.1 Introduction
This chapter describes the AMIBIOS™ Setup utility for the motherboard. The BIOS is stored on a chip and can be easily upgraded using a flash program.
Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the Manual Download area of our website for any changes to the BIOS that may not be reflected in this manual.
Starting the Setup Utility
To enter the BIOS Setup Utility, hit the
The Main BIOS screen has two main frames. The left frame displays all the options that can be configured. "Grayed-out" options cannot be configured. The right frame displays the key legend. Above the key legend is an area reserved for a text message. When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note that the BIOS has default text messages built in. We retain the option to include, omit, or change any of these text messages.) Settings printed in Bold are the default values.
A "▶" indicates a submenu. Highlighting such an item and pressing the
The BIOS setup utility uses a key-based navigation system called hot keys. Most of these hot keys (
6.2 Main Setup
When you first enter the AMI BIOS setup utility, you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS setup screen is shown below and the following features will be displayed:

text_image
Action Setup Utility - Copyright (C) 2018 American Megatrends, Inc. Main Advanced Event Logs IPMI Security Boot Save & Exit System Date [Red 05/16/2018] System Time [16:41:17] Supermicro A2SDV-4C-LN10PF BICO Version 1.0c Build Date 05/09/2018 CPLD Version 04.21.15 Memory Information Total Memory 6192 MB Memory Speed 2133 MHz Set the Date. Use Tab to switch between Date elements. Default Ranges: Year: 2005-2009 Months: 1-12 Days: dependent on month +: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.19.1266. Copyright (C) 2018 American Megatrends, Inc.System Date/System Time
Use this feature to change the system date and time. Highlight System Date or System Time using the arrow keys. Enter new values using the keyboard. Press the
Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00. The date's default value is the BIOS build date after RTC reset.
Supermicro A2SDV-8C-LN10PF
BIOS Version
This feature displays the version of the BIOS ROM used in the system.
Build Date
This feature displays the date when the version of the BIOS ROM used in the system was built.
CPLD Version
This feature displays the Complex Programmable Logic Device (CPLD) version.
Memory Information
Total Memory
This feature displays the total size of memory available in the system.
Memory Speed
This feature displays the default speed of the memory modules installed in the system.
6.3 Advanced Setup Configurations
Use this menu to configure Advanced settings.

text_image
Boot Feature CPU Configuration Chipset Configuration SATA Configuration Intel Server Platform Services PCIe/PCI/FnP Configuration Super ID Configuration Serial Port Console Redirection ACPI Settings Trusted Computing Iscs1 Configuration Intel(R) I210 Gigabit Fiber Network Connection - OC:C4:7A:... Intel(R) I210 Gigabit Fiber Network Connection - OC:C4:7A:... Intel(R) I350 Gigabit Network Connection - OC:C4:7A:FC:F2:BE Intel(R) I350 Gigabit Network Connection - OC:C4:7A:FC:F2:BF Intel(R) I350 Gigabit Network Connection - OC:C4:7A:FC:F2:C0 Intel(R) I350 Gigabit Network Connection - OC:C4:7A:FC:F2:C1 Intel(R) Ethernet Connection X553 1GbE - OC:C4:7A:FC:F2:C2 Intel(R) Ethernet Connection X553 1GbE - OO:C4:7A:FC:F2:C3 Intel(R) Ethernet Connection X553 1GbE - OC:C4:7A:FC:F2:C4 Intel(R) Ethernet Connection X553 1GbE - OO:C4:7A:FC:F2:C5 Boot Feature Configuration Page +: Select Screen ↑↓: Select Item Enter: Select +/-: Change Dot. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit version 2.19.1266, Copyright (C): 2018 American Megatrends, Inc.Warning: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency or an incorrect BIOS timing setting may cause the system to malfunction. When this occurs, restore to default manufacturer settings.
▶Boot Feature
Quiet Boot
Use this feature to select the screen display between POST messages or the OEM logo at bootup. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages. The options are Disabled and Enabled.
Bootup NumLock State
Use this feature to set the Power-on state for the Numlock key. The options are Off and On.
Wait For "F1" If Error
This feature forces the system to wait until the F1 key is pressed if an error occurs. The options are Disabled and Enabled.
Power Configuration
Watch Dog Function
If enabled, the Watch Dog timer will allow the system to reboot when it is inactive for more than five minutes. The options are Disabled and Enabled.
Power Button Function
This feature controls how the system shuts down when the power button is pressed. Select 4 Seconds Override for the user to power off the system after pressing and holding the power button for four seconds or longer. Select Instant Off to instantly power off the system as soon as the user presses the power button. The options are 4 Seconds Override and Instant Off.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Power Off for the system power to remain off after a power loss. Select Power On for the system power to be turned on after a power loss. Select Last State to allow the system to resume its last power state before a power loss. The options are Stay Off, Power On, and Last State.
▶CPU Configuration
The following CPU information will display:
• Displays the CPU model
- Processor ID
- Microcode Revision
- Processor Frequency
• CPU BCLK Frequency
- L1 Cache RAM
- L2 Cache RAM
EIST (GV3)
EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically adjust processor voltage and core frequency to reduce power consumption and heat dissipation. The options are Disable and Enable.
BIOS Request Frequency
Use this feature to instruct how much frequency will be delivered to the processor. The options are Disable and Enable.
TM1
Select Enable to activate TM1 support for system thermal monitoring. TM1 allows the CPU to regulate its power consumption based upon the modulation of the CPU Internal clock when the CPU temperature reaches a pre-defined overheating threshold. The options are Disable and Enable.
TM2 Mode
Use this feature to select the throttling mode for TM2. The options are LFM Throttling and Adaptive Throttling.
*The feature above is not available when EIST (GV3) or TM1 is disabled.
Dynamic Self Refresh
Select Enable to support Dynamic Self-Refreshing for the onboard memory controller. The options are Disable and Enable.
CPU C State
Select Enabled to enhance the Cx state of the CPU. Reboot the system for this feature to take effect. The options are Disable and Enable.
Package C State limit
Use this item to set the limit on the C-state package register. The options are No Pkg C-State, No S0lx, and No Limit. This feature is not available when CPU C State is disabled.
Max Core C State
Use this feature to select the CPU C-state. The options are C1 and C6. This feature is not available when CPU C State is disabled.
Enhanced Halt State (C1E)
Select Enable to enable Enhanced Halt State support, which will significantly reduce the CPU's power consumption by minimizing its clock cycles and voltage use during a Halt State. The options are Disable and Enable. This feature is not available when CPU C State is disabled.
Monitor/Mwait
Select Enable to enable the Monitor/Mwait instructions. The Monitor instructions monitors a region of memory for writes, and MWait instructions instruct the CPU to stop until the monitored region begins to write. The options are Disable and Enable. This feature is not available when CPU C State is disabled.
L1 Prefetcher
If enabled, the hardware prefetcher will prefetch streams of data and instructions from the main memory to the L1 cache to improve CPU performance. The options are Enable and Disable.
L2 Prefetcher
If enabled, the hardware prefetcher will prefetch streams of data and instructions from the main memory to the L2 cache to improve CPU performance. The options are Enable and Disable.
ACPI 3.0 T-States
Select Enable to support ACPI (Advanced Configuration and Power Interface) 3.0 T-States to determine how the processor will report to the operating system during CPU-Throttling states. The options are Disable and Enable.
*If the feature above is enabled, T-State Throttle will be available for configuration:
T-State Throttle
Use this feature to select the On-Die thermal throttling. The options are default, 12.5%, 25.0%, 37.5%, 50.0%, 62.5%, 75.0%, and 87.5%.
Max CPUID Value Limit
Use this feature to set the maximum CPU ID value. Enable this feature to boot the legacy operating systems that cannot support processors with extended CPUID functions. The options are Disable and Enable.
Execute Disable Bit
Set to Enable for Execute Disable Bit support, which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot, thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damaging the system during a virus attack. The options are Disable and Enable. (Refer to the Intel and Microsoft websites for more information.)
Virtualization Technology
Select Enable to use Intel Virtualization Technology to allow one platform to run multiple operating systems and applications in independent partitions, creating multiple virtual systems in one physical computer. The options are Disable and Enable.
Extended APIC (Advanced Programmable Interrupt Controller)
Based on the Intel Hyper-Threading technology, each logical processor (thread) is assigned 256 APIC IDs (APIDs) in 8-bit bandwidth. When this item is set to Enable, the APIC ID will be expanded from 8 bits to 16 bits to provide 512 APIDs to each thread to enhance CPU performance. The options are Disable and Enable.
AES-NI
Select Enable to use the Intel Advanced Encryption Standard (AES) New Instructions (NI) to ensure data security. The options are Disable and Enable.
Lock PACKAGE\_RAPL\_LIMIT
Use this feature to lock the MSR 0x610 bit. The options are Disable and Enable.
*If the feature above is set to Disable, the next three features will be available for configuration:
PL1 Time Window
Use this feature to define the Running Average Power Limit (RAPL) time window 1 in milliseconds. The default setting is 45. Use the "+" or "-" keys to define the setting.
PL1 Power Level (This feature is dependent on the CPU)
Use this feature to define the Running Average Power Limit (RAPL) power limit 1 in Watts.
The default setting is 31. Use the "+" or "-" keys to define the setting.
PL2 Power Level (This feature is dependent on the CPU)
Use this feature to define the Running Average Power Limit (RAPL) power limit 2 in Watts.
The default setting is 37. Use the "+" or "-" keys to define the setting.
Active Processor Cores
Use this feature to set the number of processor cores that will be activated for each CPU.
Select 0 to activate all processor cores.
▶Chipset Configuration
Warning: Setting the wrong values in the following sections may cause the system to malfunction.
▶North Bridge Configuration
North Bridge Configuration
Memory Information
- MRC Version
- Total Memory
• Memory Frequency
VT-d
Select Enabled to enable Intel Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to VMM through the DMAR ACPI Tables. This feature offers fully-protected I/O resource-sharing across the Intel platforms, providing the user with greater reliability, security, and availability in networking and data-sharing. The options are Disabled and Enabled.
VT-d Interrupt remapping
Use this feature to enable Interrupt Remapping support, which detects and controls external interrupt requests. The options are Disabled and Enabled.
Fast Boot
Use this feature to enable or disable fast path through the memory reference code. The options are Disabled and Enabled.
Command Address Parity
Use this feature to address the DDR4 command parity. The options are Disabled and Enabled.
Memory Frequency
Use this feature to set the maximum memory frequency for onboard memory modules. The options are DDR-1600, DDR-1867, DDR-2133, and DDR-2400.
MMIO Size / BMBOUND Base
Use this feature to select the memory mapped IO size and BMBOUND base setting. The low for the two settings will always be 4GB. The options are Auto, 1024M/3072M, and 3072M/1024M.
TCL performance
Use this feature to enable the CAS Latency (tCL) to increase memory performance. The options are Disabled and Enabled.
Memory Preservation
Enable this feature for the memory content to be preserved through a warm reset. The options are Disabled and Enabled.
Patrol Scrub Enable
Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected in a memory module and send the correction to the requestor (the original source). When this item is set to Enable, the IO hub will read and write back one cache line every 16K cycles if there is no delay caused by internal processing. By using this method, roughly 64GB of memory behind the IO hub will be scrubbed every day. The options are Enabled and Disabled.
Patrol Scrub Period
Use this feature to select the Patrol Scrub period. The options are 24 hours, 10 hours, 4 hours, and 1 hour.
Demand Scrub Enable
Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found in a memory module. When the CPU or I/O issues a demand-read command, and the read data from memory turns out to be a correctable error, the error is corrected and sent to the requestor (the original source). Memory is corrected as well. Select Enable to use Demand Scrubbing for ECC memory correction. The options are Disabled and Enabled.
Write Data Early Enable
Use this feature to enable or disable write data early. The options are Disabled and Enabled.
Select Refresh Rate
Use this feature to select the memory refresh rate. The options are 1x/2x and 1x/2x/4x.
CKE Power Down
Clock enable (CKE) Power Down controls the low power down for the memory. The options are Disabled, Active Power Down, and Precharge Power Down.
Memory Thermal Throttling
Memory thermal throttling is a power management feature that monitors read and write activities to control power consumption. The options are Auto and Disabled.
*If the feature above is set to Auto, CLTT Mode and MEMTRIP will be available for configuration:
CLTT Mode
Use this feature to select the Closed Loop Thermal Throttling (CLTT) mode. The default option is Passthru.
MEMTRIP
Use this feature to enable or disable MEMTRIP. The options are Disabled and Enabled.
Scrambler
This feature scrambles data in the memory and makes it inaccessible. The options are Disabled and Enabled.
Slow Power Down Exit
Use this feature to enable or disable the slow power down exit from pre-charge. The options are Disabled and Enabled.
▶ South Bridge Configuration
South Bridge Configuration
- USB Module Version
- USB Controllers:
- USB Devices:
Legacy USB Support
Select Enabled to support onboard legacy USB devices. Select Auto to disable legacy support if there are no legacy USB devices present. Select Disable to have all USB devices available for EFI applications only. The options are Enabled, Disabled, and Auto.
XHCI Hand-Off
This is a work-around solution for operating systems that do not support XHCI (Extensible Host Controller Interface) hand-off. The XHCI ownership change should be claimed by the XHCI driver. The settings are Enabled and Disabled.
Port 60/64 Emulation
Select Enabled for I/O port 60h/64h emulation support, which in turn will provide complete legacy USB keyboard support for the operating systems that do not support legacy USB devices. The options are Disabled and Enabled.
▶ IQAT Configuration
IQAT
Select Enabled to hide IQAT devices from the operating system. The options are Disabled and Enabled.
Set 64B MRR/MPL
Use this feature to enable setting for the 64B MRR/MPL in IQAT DevCTL register. The options are Disabled and Enabled.
*The following feature is displayed if an M.2 device is detected by the system:
M.2 (B-Key) I/O Selection
Use this feature to select the type of M.2 interface. The options are SATA, PCIe, PCIe/USB, and SATA/USB.
Flexible I/O Selection
Use this feature to configure the port to be PCI-E or SATA. The options are PCIe x2 and SATA [2:1].
▶SATA Configuration
▶ SATA0
SATA 0 Enable controller
This item enables or disables the onboard SATA controller supported by the processor. The options are Enabled and Disabled.
SATA 0 ALPM
When this feature is set to Enabled, the SATA AHCI controller manages the power usage of the SATA link. The controller will put the link in a low power mode during extended periods of I/O inactivity and will return the link to an active state when I/O activity resumes. The options are Enabled and Disabled.
*If the feature above is set to Enabled, SATA 0 ALPM will be available for configuration:
SATA 0 LPM
Use this feature to enable or disable Aggressive Link Power Management. The options are Enabled and Disabled.
SATA 0 SGPIO/LED
Use this feature to select SATA SGPIO or SATA LED. The options are SATA SGPIO and SATA LED.
▶I-SATA (M.2 - B Key)
This following information is displayed for each M.2 drive entry:
• Device Information:
- Device Size:
I-SATA (M.2 - B Key) Enable/disable port
Use this feature to disable or enable the SATA port number. The options are Enabled and Disabled.
I-SATA (M.2 - B Key) Spin up
When the value of an edge detect or the value of an image binary (pixel) of a device is from 0 to 1, select Enabled to allow the PCH to start a COMRESET initialization sequence on this device. The options are Enabled and Disabled.
▶ SATA1
SATA 1 Enable controller
This item enables or disables the onboard SATA controller supported by the processor. The options are Enabled and Disabled.
SATA 1 ALPM
When this feature is set to Enabled, the SATA AHCI controller manages the power usage of the SATA link. The controller will put the link in a low power mode during extended periods of I/O inactivity and will return the link to an active state when I/O activity resumes. The options are Enabled and Disabled.
*If the feature above is set to Enabled, SATA 1 ALPM will be available for configuration:
SATA 1 ALPM
Use this feature to enable or disable Aggressive Link Power Management. The options are Enabled and Disabled.
SATA 1 SGPIO/LED
Use this feature to select SATA SGPIO or SATA LED. The options are SATA SGPIO and SATA LED.
▶I-SATA0 - I-SATA2
This following information is displayed for each SATA drive entry:
• Device Information
- Device Size
Enable/disable port
Use this feature to disable or enable the SATA port number. The options are Enabled and Disabled.
Spin up
When the value of an edge detect or the value of an image binary (pixel) of a device is from 0 to 1, select Enabled to allow the PCH to start a COMRESET initialization sequence on this device. The options are Enabled and Disabled.
▶Intel Server Platform Services
General ME Configuration
• Operational Firmware Version
• ME Firmware Type
• Backup Firmware Version
• Recovery Firmware Version
• ME Firmware Features
• ME Firmware Status #1
• ME Firmware Status #2
- Current State
- Error Code
▶PCIe/PCI/PnP Configuration
Platform Mode - A5.01.12
PCI Devices Common Settings:
Above 4G Decoding
Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address. The options are Disabled and Enabled.
SR-IOV Support
Select Enabled for Single-Root IO Virtualization (SR-IOV) support. SR-IOV is an extension of the PCI Express interface and consists of two functions: physical functions (PF) and virtual functions (VF). PF is the primary function and is used to control and configure PCI Express devices, whereas VF is the lightweight function that offers limited configuration. The options are Disabled and Enabled.
Maximum Payload
Select Auto for the system BIOS to automatically set the maximum payload value for a PCI-E device to enhance system performance. The options are Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
Maximum Read Request
Select Auto for the system BIOS to automatically set the maximum size for a read request for a PCI-E device to enhance system performance. The options are Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
ASPM Support
Use this item to set the Active State Power Management (ASPM) level for a PCI-E device. Select Auto for the system BIOS to automatically set the ASPM level based on the system configuration. Select Disabled to disable ASPM support. Select Force L0s to force all links to L0s state. The options are Disabled, Auto, and Force L0s.
Warning: Enabling ASPM support may cause some PCI-E devices to fail!
ARI Forwarding
Select Enabled to lift a traditional Device Number restriction when turning a Type1 Configuration request into a Type0 Configuration request to permit access to extended functions in an ARI Device immediately below the port. The options are Disabled and Enabled.
CPU SLOT7 PCI-E 3.0 X4 OPROM
Use this item to select the firmware type for the add-on card for this slot. The options are Disabled, Legacy, and EFI.
KEY-B SATA3/USB3 OPROM
Use this item to select the firmware type for the add-on card for this slot. The options are Disabled, Legacy, and EFI.
Onboard LAN OPROM Type
Use this feature to select the Onboard LAN Option ROM type. The options are Disabled, Legacy, and EFI.
Onboard Video OPROM
Use this feature to select the Onboard Video Option ROM type. The options are Disabled, Legacy, and EFI.
VGA Priority
Use this feature to select the active video type. The options are Onboard and Offboard.
Network Stack
Select Enabled to enable PXE (Preboot Execution Environment) or UEFI (Unified Extensible Firmware Interface) for network stack support. The options are Enabled and Disabled.
*If "Network Stack" is set to Enabled, the next four features will be available for configuration:
Ipv4 PXE Support
Use this feature to enable lpv4 PXE Boot Support. If this feature is disabled, it will not create the lpv4 PXE Boot option. The options are Disabled and Enabled.
Ipv6 PXE Support
Use this feature to enable lpv6 PXE Boot Support. If this feature is disabled, it will not create the lpv6 PXE Boot option. The options are Disabled and Enabled.
PXE boot wait time
Use this feature to select the wait time to press the ESC key to abort the PXE boot. The default is 0.
Media Detect Count
Use this feature to select the wait time in seconds to detect LAN media. The default is 1.
▶Super IO Configuration
Super IO Configuration
Super IO Chip AST2400
▶ Serial Port 1 Configuration
Serial Port 1 Configuration
Serial Port 1
Select Enabled to enable the onboard serial port specified by the user. The options are Disabled and Enabled.
Device Settings
This feature displays the base I/O port address and the Interrupt Request address of a serial port specified by the user. This feature is hidden when Serial Port 1 is disabled.
Serial Port 1 Change Settings
This feature specifies the base I/O port address and the Interrupt Request address of Serial Port 1. Select Auto for the BIOS to automatically assign the base I/O and IRQ address to a specified serial port. The options are Auto, (IO=3F8h; IRQ=4), (IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), (IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12); (IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), and (IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12).
▶Serial Port Console Redirection
COM 1 Console Redirection
Select Enabled to enable COM Port 1 for Console Redirection, which will allow a client machine to be connected to a host machine at a remote site for networking. The options are Enabled and Disabled.
*If the feature above is set to Enabled, the following items will become available for configuration:
▶COM1 Console Redirection Settings
COM1 Terminal Type
This feature allows the user to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support. Select ANSI to use the Extended ASCII Character Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are VT100, VT100+, VT-UTF8, and ANSI.
COM1 Bits per second
Use this item to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600, and 115200 (bits per second).
COM1 Data Bits
Use this feature to set the data transmission size for Console Redirection. The options are 7 and 8.
COM1 Parity
A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark, and Space.
COM1 Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2.
COM1 Flow Control
Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None and Hardware RTS/CTS.
COM1 VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Disabled and Enabled.
COM1 Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server. The options are Disabled and Enabled.
COM1 Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Disabled and Enabled.
COM1 Putty KeyPad
This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SCO, ESCN, and VT400.
SOL
SOL Console Redirection
Select Enabled to use the SOL port for Console Redirection. The options are Disabled and Enabled.
*If the feature above is set to Enabled, the following items will become available for configuration:
▶SOL Console Redirection Settings
Use the features in this submenu to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user.
SOL Terminal Type
Use this feature to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support. Select ANSI to use the Extended ASCII Character Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are VT100, VT100+, VT-UTF8, and ANSI.
SOL Bits per second
Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600, and 115200 (bits per second).
SOL Data Bits
Use this feature to set the data transmission size for Console Redirection. The options are 7 and 8.
SOL Parity
A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark, and Space.
SOL Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2.
SOL Flow Control
Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None and Hardware RTS/CTS.
SOL VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Disabled and Enabled.
SOL Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server. The options are Disabled and Enabled.
SOL Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Disabled and Enabled.
SOL Putty KeyPad
This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SCO, ESCN, and VT400.
Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS)
Use the features in this submenu to configure Console Redirection settings to support Out-of-Band Serial Port management.
EMS (Emergency Management Services) Console Redirection
Select Enabled to use a COM port selected by the user for EMS Console Redirection. The options are Disabled and Enabled.
*If the feature above is set to Enabled, the following items will become available for configuration:
▶EMS Console Redirection Settings
This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user.
Out-of-Band Mgmt Port
The feature selects a serial port in a client server to be used by the Microsoft Windows Emergency Management Services (EMS) to communicate with a remote host server. The options are COM1 and SOL.
Terminal Type
Use this feature to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII character set. Select VT100+ to add color and function key support. Select ANSI to use the extended ASCII character set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are VT100, VT100+, VT-UTF8, and ANSI.
Bits per second
This item sets the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 57600, and 115200 (bits per second).
Flow Control
Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None, Hardware RTS/CTS, and Software Xon/Xoff.
Data Bits
Parity
Stop Bits
▶ ACPI Settings
ACPI Settings
WHEA Support
Select Enabled to support the Windows Hardware Error Architecture (WHEA) platform and provide a common infrastructure for the system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monitoring. The options are Disabled and Enabled.
Headless Support
Select Enabled for the system to function without a keyboard, mouse, or monitor. The options are Disabled and Enabled.
▶Trusted Computing (Available when a TPM device is installed and detected by the BIOS)
*The features from here to Current Status Information are displayed if a TPM 1.2 module is detected:
Security Device Support
If this feature and the TPM jumper on the motherboard are both set to Enabled, onboard security devices will be enabled for TPM support to enhance data integrity and network security. Reboot the system for a change in this setting to take effect. The options are Disable and Enable.
TPM State
Select Enabled to use TPM (Trusted Platform Module) settings to enhance system data security. Reboot your system for any change in the TPM state to take effect. The options are Disable and Enable.
Pending operation
Use this item to schedule a TPM-related operation to be performed by a security device for system data integrity. Your system will reboot to carry out a pending TPM operation. The options are None and TPM Clear.
Note: Reboot the computer to change the state of the security device.
Device Select
Use this feature to select the TPM version. TPM 1.2 will restrict support to TPM 1.2 devices. TPM 2.0 will restrict support to TPM 2.0 devices. Select Auto to enable support for both versions. The default setting is Auto.
Current Status Information
This item displays the status of the TPM support on this motherboard.
- TPM Enabled Status
- TPM Active Status
- TPM Owner Status
*The features from here to Device Select on the next page are displayed if a TPM 2.0 module is detected:
TPM20 Device Found
Vendor: IFX
Firmware Version: 5.51
Configuration
Security Device Support
If this feature and the TPM jumper on the motherboard are both set to Enabled, onboard security devices will be enabled for TPM support to enhance data integrity and network security. Reboot the system for a change in this setting to take effect. The options are Disable and Enable.
The following TPM information will be displayed:
• Active PCR banks
• Available PCR banks
*If the feature "Security Device Support" is set to Enable, the following features will become available for configuration:
SHA-1 PCR Bank
Use this item to disable or enable the SHA-1 Platform Configuration Register (PCR) bank for the installed TPM device. The options are Disabled and Enabled.
SHA256 PCR Bank
Use this item to disable or enable the SHA256 Platform Configuration Register (PCR) bank for the installed TPM device. The options are Disabled and Enabled.
Pending operation
Use this item to schedule a TPM-related operation to be performed by a security device for system data integrity. Your system will reboot to carry out a pending TPM operation. The options are None and TPM Clear.
Platform Hierarchy
Use this item to disable or enable platform hierarchy for platform protection. The options are Disabled and Enabled.
Storage Hierarchy
Use this item to disable or enable storage hierarchy for cryptographic protection. The options are Disabled and Enabled.
Endorsement Hierarchy
Use this item to disable or enable endorsement hierarchy for privacy control. The options are Disabled and Enabled.
TPM2.0 UEFI Spec Version
Use this feature to specify the TPM UEFI spec version. TCG 1.2 has support for Windows® 2012, Windows 8, and Windows 10. TCG 2 has support for Windows 10 or later. The options are TCG_1_2 and TCG_2.
Physical Presence Spec Version
Use this feature to select the PPI spec version. The options are 1.2 and 1.3.
Device Select
Use this feature to select the TPM version. TPM 1.2 will restrict support to TPM 1.2 devices. TPM 2.0 will restrict support to TPM 2.0 devices. Select Auto to enable support for both versions. The default setting is Auto.
▶iSCSI Configuration
iSCSI Initiator Name
This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format. Once the name of the iSCSI Initiator is entered into the system, configure the proper settings for the following items.
▶ Add an Attempt
▶ Delete Attempts
▶ Change Attempt Order
Intel® I210 Gigabit Fiber Network Connection - 0C:C4:7A:...
Intel® I210 Gigabit Fiber Network Connection - 0C:C4:7A:...
Intel® I350 Gigabit Network Connection - 0C:C4:7A:XX:XX:XX
Intel® I350 Gigabit Network Connection - 0C:C4:7A:XX:XX:XX
Intel® I350 Gigabit Network Connection - 0C:C4:7A:XX:XX:XX
Intel® I350 Gigabit Network Connection - 0C:C4:7A:XX:XX:XX
Intel® Ethernet Connection X553 1GbE - 0C:C4:7A:XX:XX:XX
Intel® Ethernet Connection X553 1GbE - 0C:C4:7A:XX:XX:XX
Intel® Ethernet Connection X553 1GbE - 0C:C4:7A:XX:XX:XX
Intel® Ethernet Connection X553 1GbE - 0C:C4:7A:XX:XX:XX
These features display the following information:
NIC Configuration (Dependent on the LAN chipset)
Link Speed
Use this feature to change the link speed and duplex for the current port. The options are Auto Negotiated, 10Mbps Half, 10Mbps Full, 100Mbps Half, and 100Mbps full.
SFP LAN
This feature is grayed out and cannot be selected.
Wake On LAN
Select enabled to wake the system with a magic packet. The options are Enabled and Disabled.
Blink LEDs
This feature allows the user to specify the duration for LEDs to blink. The range is from 0 to 15 seconds. The default setting is 0.
UEFI Driver
This feature displays the UEFI driver version.
Adapter PBA
This feature displays the Processor Bus Adapter (PBA) model number. The PBA number is a nine digit number (i.e., 010B00-000) located near the serial number.
Device Name
This feature displays the adapter device name.
Chip Type
This feature displays the network adapter chipset name.
PCI Device ID
This feature displays the device ID number.
PCI Address
This feature displays the PCI address for this computer. PCI addresses are three two-digit hexadecimal numbers.
Link Status
This feature displays the connection status.
MAC Address
This feature displays the MAC address for this computer. MAC addresses are six two-digit hexadecimal numbers.
Virtual MAC Address
This feature displays the Virtual MAC address for this computer. MAC addresses are six two-digit hexadecimal numbers.
6.4 Event Logs
Use this menu to configure Event Log settings.

text_image
Auto Setup Utility - Copyright (C) 2018 American Megatrends, Inc. Main Advanced Event Logs IPMI Security Boot Save & Exit Change SMBIOS Event Log Settings View SMBIOS Event Log Press▶Change SMBIOS Event Log Settings
Enabling/Disabling Options
PCIe ELog Support
Use this feature to enable or disable PCIe error logging support. The options are Disabled and Enabled.
Memory ELog Support
Use this feature to enable or disable memory error logging support. The options are Disabled and Enabled.
Error Threshold
Use this feature to modify the MCI error threshold from 1 to 32768. The default is 100.
SMBIOS Event Log
Change this feature to enable or disable all features of the SMBIOS Event Logging during system boot. The options are Disabled and Enabled.
Erasing Settings
Erase Event Log
Select Enabled to erase all error events in the SMBIOS (System Management BIOS) log before an event logging is initialized at bootup. The options are No, Yes, Next reset, and Yes, Every reset.
When Log is Full
Select Erase Immediately to immediately erase all errors in the SMBIOS event log when the event log is full. Select Do Nothing for the system to do nothing when the SMBIOS event log is full. The options are Do Nothing and Erase Immediately.
SMBIOS Event Log Standard Settings
Log System Boot Event
Select Enabled to log system boot events. The options are Enabled and Disabled.
MECI (Multiple Event Count Increment)
Enter the increment value for the multiple event counter. Enter a number between 1 and 255. The default setting is 1.
METW (Multiple Event Count Time Window)
This feature is used to determine how long (in minutes) the multiple event counter should wait before generating a new event log. Enter a number between 0 and 99. The default setting is 60.
Note: All values here that have been changed do not take effect until the computer is restarted.
▶View SMBIOS Event Log
This item allows the user to view the event in the SMBIOS event log. The following categories are displayed:
DATE/TIME/ERROR CODE/SEVERITY
6.5 IPMI
Use this menu to configure Intelligent Platform Management Interface (IPMI) settings.

text_image
Action Setup Utility - Copyright (C) 2018 American Megatrends, Inc. Main Advanced Event Logs IFMI Security Boot Save & Exit BMC Firmware Revision 3.71 IPMI STATUS Working ► System Event Log ► BMC Network Configuration IPMI Extended Instruction [Enabled] PressBMC Firmware Revision
This feature indicates the IPMI firmware revision used in your system.
IPMI Status
This feature indicates the status of the IPMI firmware installed in your system.
▶System Event Log
Enabling/Disabling Options
SEL Components
Select Enabled for all system event logging at bootup. The options are Disabled and Enabled.
Erasing Settings
Erase SEL
Select Yes, On next reset to erase all system event logs upon next system reboot. Select Yes, On every reset to erase all system event logs upon each system reboot. Select No to keep all system event logs after each system reboot. The options are No, Yes, On next reset, and Yes, On every reset.
When SEL is Full
This feature allows the user to determine what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full. The options are Do Nothing and Erase Immediately.
Note: All values here that have been changed do not take effect until the computer is restarted in the BIOS setup menu.
▶BMC Network Configuration
The following features will be displayed:
IPMI LAN Selection
This feature displays the IPMI LAN setting. The default setting is Failover.
IPMI Network Link Status:
This feature displays the IPMI Network Link status. The default setting is Shared LAN.
Update IPMI LAN Configuration
Select Yes for the BIOS to implement all IP/MAC address changes at the next system boot. The options are No and Yes.
\*If the feature above is set to Yes, Configuration Address Source and VLAN will become available for configuration:
Configuration Address Source
Use this feature to select the source of the IP address for this computer. If Static is selected, you will need to know the IP address of this computer and enter it to the system manually in the field. If DHCP is selected, the BIOS will search for a DHCP (Dynamic Host Configuration Protocol) server in the network that it is attached to and request the next available IP address for this computer. The options are DHCP and Static.
The following features are assigned IP addresses automatically if DHCP is selected, or they can be configured manually if Static is selected.
Station IP Address
This feature displays the Station IP address for this computer. This should be in decimal and in dotted quad form (i.e., 192.168.10.253).
Subnet Mask
This feature displays the sub-network that this computer belongs to. The value of each three-digit number separated by dots should not exceed 255.
Station MAC Address
This feature displays the Station MAC address for this computer. MAC addresses are six two-digit hexadecimal numbers.
Gateway IP Address
This feature displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i.e., 192.168.10.253).
VLAN
This feature is configurable if the Update IPMI LAN Configuration feature is set to Yes. Use this feature to enable or disable the IPMI VLAN function. The options are Disable and Enable.
IPMI Extended Instruction
Use this feature to enable IPMI extended function support. The options are Enabled and Disabled. When Disabled, the system powers on quickly by removing BIOS support for extended IPMI features. The Disable option is for applications that require faster power on time without using Supermicro Update Manager (SUM) or extended IPMI features. The BMC network configuration in the BIOS setup will also be invalid when IPMI Extended Instruction is disabled. The general BMC function and motherboard health monitor such as fan control will still function even when this option is disabled.
6.6 Security
Use this menu to configure Security settings.

text_image
Aotio Setup Utility - Copyright (C) 2018 American Megatrends, Inc. Main Advanced Event Logs IFHI Security Boot Save & Exit Password Description If ONLY the Administrator's password is set, then this only limits access to Setup and is only asked for when entering Setup. If ONLY the User's password is set, then this is a power on password and must be entered to boot or enter Setup. In Setup the User will have Administrator rights. The password length must be in the following range: Minimum length 3 Maximum length 20 Password Check [setup] Administrator Password Secure Boot Setup: Check password while invoking setup. Always: Check password while invoking setup as well as on each boot. +: Select Screen +: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.19.1266. Copyright (C) 2018 American Megatrends, Inc.Password Check
Select Setup for the system to check for a password at Setup. Select Always for the system to check for a password at bootup or upon entering the BIOS Setup utility. The options are Setup and Always.
Administrator Password
Use this feature to set the administrator password, which is required to enter the BIOS setup utility. The length of the password should be from 3 characters to 20 characters long.
*The feature below is displayed if an Administrator Password is set:
User Password
Use this feature to set a user password.
▶ Secure Boot
Platform Mode - Setup
Secure Boot - Not Active
Vendor Keys - Not Active
Enable Secure Boot
Select Enable for secure boot support to ensure system security at bootup. The options are Disabled and Enabled.
Secure Boot Mode
This feature allows the user to select the desired secure boot mode for the system. The options are Standard and Custom.
*If Secure Boot Mode is set to Custom, Key Management features will be available for configuration:
CSM Support
This feature is for manufacturing debug purposes.
▶ Reset to Setup Mode
Select Yes to delete all Secure Boot key databases and force the system to Setup Mode. The options are Yes and No.
Select Yes to restore all factory keys to the default settings. The options are Yes and No.
▶Key Management
This submenu allows the user to configure the following Key Management settings.
Provision Factory Defaults
Select Enabled to install the default Secure Boot keys set by the manufacturer. The options are Disabled and Enabled.
▶Enroll Efi Image
This feature allows the image to run in Secure Boot mode.
▶ Save All Secure Boot Variables
This feature allows the user to decide if all secure boot variables should be saved.
▶ Platform Key (PK)
Save to File
Select Yes to save the PK to a storage device.
Set New
Select Yes to load the new PK from the manufacturer's defaults. Select No to load the platform keys from a file. The options are Yes and No.
Erase
Select Yes to delete the PK from NVRAM. The options are Yes and No.
▶Key Exchange Keys
Save to File
Select Yes to save the KEK to a storage device.
Set New
Select Yes to load the KEK from the manufacturer's defaults. Select No to load the KEK from a file. The options are Yes and No.
Append
Select Yes to add the KEK from the manufacturer's defaults list to the existing KEK. Select No to load the KEK from a file. The options are Yes and No.
Erase
Select Yes to delete the KEK from NVRAM. The options are Yes and No.
▶ Authorized Signatures
Save to File
Select Yes to save the db to a storage device.
Set New
Select Yes to load the db from the manufacturer's defaults. Select No to load the db from a file. The options are Yes and No.
Append
Select Yes to add the database from the manufacturer's defaults to the existing db. Select No to load the db from a file. The options are Yes and No.
Erase
Select Yes to delete the db from NVRAM. The options are Yes and No.
▶Forbidden Signatures
Save to File
Select Yes to save the dbx to a storage device.
Set New
Select Yes to load the dbx from the manufacturer's defaults. Select No to load the dbx from a file. The options are Yes and No.
Append
Select Yes to add the dbx from the manufacturer's defaults to the existing dbx. Select No to load the dbx from a file. The options are Yes and No.
Erase
Select Yes to delete the dbx from NVRAM. The options are Yes and No.
▶ Authorized TimeStamps
Set New
Select Yes to load the dbt from the manufacturer's defaults. Select No to load the dbt from a file. The options are Yes and No.
Append
Select Yes to add the dbt from the manufacturer's defaults list to the existing dbt. Select No to load the dbt from a file. The options are Yes and No.
▶OsRecovery Signatures
Set New
Select Yes to load the dbr from the manufacturer's defaults. Select No to load the dbr from a file. The options are Yes and No.
Append
Select Yes to add the dbr from the manufacturer's defaults list to the existing dbr. Select No to load the dbr from a file. The options are Yes and No.
6.7 Boot
Use this menu to configure Boot settings:

text_image
Auto Setup Utility - Copyright (C) 2018 American Megatrends, Inc. Main Advanced Event Logs IFMI Security Boot Save & Exit Boot Configuration Boot Mode Select [UEFI] FIXED BOOT ORDER Priorities UEFI Boot Option #1 [UEFI Hard Disk] UEFI Boot Option #2 [UEFI AP:UEFI: BuI...] UEFI Boot Option #3 [UEFI CD/DVD] UEFI Boot Option #4 [UEFI USB Hard Disk] UEFI Boot Option #5 [UEFI USB CD/DVD] UEFI Boot Option #6 [UEFI USB Key] UEFI Boot Option #7 [UEFI USB Floppy] UEFI Boot Option #8 [UEFI USB Lan] UEFI Boot Option #9 [UEFI Network:UEFI...] UEFI Application Boot Priorities UEFI NETWORK Drive BBS Priorities Delete Boot Option Select which boot device type to list in FIXED BOOT ORDER Priorities. +: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.19.1266, Copyright (C) 2018 American Megatrends, Inc.Boot mode select
Use this feature to select the boot mode for bootable devices in the system. The options are LEGACY, UEFI, and DUAL.
Fixed Boot Order Priorities
This option prioritizes the order of bootable devices that the system boots from. Press
• LEGACY/UEFI/DUAL Boot Option #1
• LEGACY/UEFI/DUAL Boot Option #2
• LEGACY/UEFI/DUAL Boot Option #3
• LEGACY/UEFI/DUAL Boot Option #4
• LEGACY/UEFI/DUAL Boot Option #5
• LEGACY/UEFI/DUAL Boot Option #6
• LEGACY/UEFI/DUAL Boot Option #7
• LEGACY/UEFI/DUAL Boot Option #8
• LEGACY/UEFI/DUAL Boot Option #9
▶UEFI Application Boot Priorities
- Boot Option # - This feature sets the system boot order of detected devices. The options are [the list of detected boot device(s)] and Disable.
▶UEFI Network Drive BBS Priorities
- Boot Option # - This feature sets the system boot order of detected devices. The options are [the list of detected boot device(s)] and Disable.
▶ Delete Boot Option
Use this feature to select a boot device to delete from the boot priority list.
6.8 Save & Exit
Use this menu to save settings and exit the BIOS.

text_image
Auto Setup Utility - Copyright (C) 2018 American Megatrends, Inc. Main Advanced Event Logs IPNI Security Boot Save & Exit Save Options Save Changes and Reset Discard Changes and Exit Save Changes Discard Changes Default Options Restore Optimized Defaults Save as User Defaults Restore User Defaults Boot Override UEFI: Built-In EFI Shell UEFI: PXE IP4 Intel(R) I350 Gigabit Network Connection UEFI: PXE IP4 Intel(R) I350 Gigabit Network Connection UEFI: PXE IP4 Intel(R) I350 Gigabit Network Connection UEFI: PXE IP4 Intel(R) I350 Gigabit Network Connection UEFI: PXE IP4 Intel(R) Ethernet Connection X553 1GbE UEFI: PXE IP4 Intel(R) Ethernet Connection X553 1GbE UEFI: PXE IP4 Intel(R) I210 Gigabit Fiber Network Connection UEFI: PXE IP4 Intel(R) I210 Gigabit Fiber Network Connection UEFI: PXE IP4 Intel(R) Ethernet Connection X553 1GbE UEFI: PXE IP4 Intel(R) Ethernet Connection X553 1GbE ubuntu Reset the system after saving the changes. +: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.19.1266. Copyright (C) 2018 American Megatrends, Inc.Save Options
Save Changes and Reset
When you have completed the system configuration changes, select this option to save all changes made and reset the system.
Discard Changes and Exit
Select this option to quit the BIOS Setup without making any permanent changes to the system configuration and reboot the computer. Select Discard Changes and Exit from the Exit menu and press
Save Changes
When you have completed the system configuration changes, select this option to save all changes made. This will not reset (reboot) the system.
Discard Changes
Select this option and press
Default Options
Restore Optimized Defaults
To set this feature, select Restore Optimized Defaults and press
Save as User Defaults
To set this feature, select Save as User Defaults from the Exit menu and press
To set this feature, select Restore User Defaults from the Exit menu and press
Boot Override
Other boot options are listed in this section. The system will boot to the selected boot option.
UEFI: Built-in EFI Shell
UEFI: PXE IP4 Intel® I210 Gigabit Fiber Network Connection
UEFI: PXE IP4 Intel® I210 Gigabit Fiber Network Connection
UEFI: PXE IP4 Intel® I350 Gigabit Network Connection
UEFI: PXE IP4 Intel® I350 Gigabit Network Connection
UEFI: PXE IP4 Intel® I350 Gigabit Network Connection
UEFI: PXE IP4 Intel® I350 Gigabit Network Connection
UEFI: PXE IP4 Intel® Ethernet Connection X553 1GbE
UEFI: PXE IP4 Intel® Ethernet Connection X553 1GbE
UEFI: PXE IP4 Intel® Ethernet Connection X553 1GbE
UEFI: PXE IP4 Intel® Ethernet Connection X553 1GbE ubuntu
Windows Boot Manager
Appendix A
BIOS Codes
A.1 BIOS Error POST (Beep) Codes
During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue the bootup process. Error messages normally appear on the screen.
Fatal errors are those which will not allow the system to continue the boot-up procedure. If a fatal error occurs, consult your system manufacturer for possible repairs.
Fatal errors are usually communicated through a series of audible beeps. The table shown below lists some common errors and their corresponding beep codes.
| BIOS Beep (POST) Codes | ||
| Beep Code Error | Message Description | |
| 1 beep Refresh Circuits have been reset (Ready to power up) | ||
| 5 short, 1 long Memory error No memory detected in system | ||
| 5 long, 2 short Display memory read/write error Video adapter missing or with faulty memory | ||
| 1 long continuous System OH System overheat condition | ||
A.2 Additional BIOS POST Codes
The AMI BIOS supplies additional checkpoint codes, which are documented online at http://www.supermicro.com/support/manuals/ ("AMI BIOS POST Codes User's Guide").
When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20).
For information on AMI updates, please refer to http://www.ami.com/products/.
Appendix B
UEFI BIOS Recovery
Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you need to update the BIOS, do not shut down or reset the system while the BIOS is updating to avoid possible boot failure. The UEFI BIOS recovery doesn't support the Ctrl+home function.
B.1 Overview
The Unified Extensible Firmware Interface (UEFI) provides a software-based interface between the operating system and the platform firmware in the pre-boot environment. The UEFI specification supports an architecture-independent mechanism for add-on card initialization to allow the UEFI OS loader, which is stored in the add-on card, to boot the system. The UEFI offers clean, hands-off control to a computer system at bootup.
B.2 Recovering the UEFI BIOS Image
A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block (a main BIOS image). The boot block contains critical BIOS codes, including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupted. When the system power is first turned on, the boot block codes execute first. Once this process is completed, the main BIOS code will continue with system initialization and the remaining POST (Power-On Self-Test) routines.
Note 1: Follow the BIOS recovery instructions below for BIOS recovery when the main BIOS boot crashes.
Note 2: When the BIOS boot block crashes, you will need to follow the procedures to make a Returned Merchandise Authorization (RMA) request. Also, you may use the Supermicro Update Manager (SUM) Out-of-Band (OOB) (https://www.supermicro.com.tw/products/nfo/SMS_SUM.cfm) to reflash the BIOS.
B.3 Recovering the BIOS Block with a USB Device
This feature allows the user to recover a BIOS image using a USB-attached device without additional utilities used. A USB flash device such as a USB Flash Drive, or a USB CD/DVD ROM/RW device can be used for this purpose. However, a USB Hard Disk drive cannot be used for BIOS recovery at this time.
The file system supported by UEFI is FAT (including FAT12, FAT16, and FAT32), which is installed on a bootable or non-bootable USB-attached device. However, the BIOS might need several minutes to locate the SUPER.ROM file if the media size becomes too large due to the huge volumes of folders and files stored in the device.
To perform UEFI BIOS recovery using a USB-attached device, follow the instructions below.
- Using a different machine, copy the "Super.ROM" binary image file into the disc Root "\" directory of a USB device or a writable CD/DVD.
Note: If you cannot locate the "Super.ROM" file in your driver disk, visit our website at www.supermicro.com to download the BIOS image into a USB flash device and rename it to "Super.ROM" for BIOS recovery use.
- Insert the USB device that contains the new BIOS image ("Super.ROM") into your USB drive and power on the system
- While powering on the system, please keep pressing
and simultaneously on your keyboard until the following screen (or a screen similar to the one below) displays.
Warning: Please stop pressing the

text_image
CPU 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CPU: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CPU: I/O/1.4 CPU: I/O/1.4 CPU: I/O/1.4 CPU: I/O/1.4 BMC IP:18,132,161,59 System initializing...Note: On the other hand, if the following screen displays, please load the "Super.ROM" file to the root folder and connect this folder to the system. (You can do so by inserting a USB device that contains the new "Super.ROM" image to your machine for BIOS recovery.)

text_image
Action Setup Utility - Copyright (C) 2017 American Megatrendo, Inc. Main Advanced Event Logs IPMS Recovery Security Cost Save & Exit AOM Image is not loaded AOM Image update denied +: Select Screen #: Select Item Enter: Select +/-: Change Dot, F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESE: Exit Version 2.19.1266, Copyright (C) 2017 American Megatrendo, Inc.- After locating the new BIOS binary image, the system will enter the BIOS Recovery menu as shown below.

text_image
Aptio Setup Utility - Copyright (C) 2017 American Nepatrends, Inc. Help Advanced Event Logs PDF Recovery Security Boot Save & Exit Please select blocks you want to update Reset Window (Enabled) Boot Stock Update (Enabled) ► Proceed with flash update Set this option to reset NVRAM to default values +/- Select Screen TL: Select Item Enter: Select +/-: Change Dot... F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESD: Exit Version 2.19.1266, Copyright (C) 2017 American Nepatrends, Inc.Note: At this point, you may decide if you want to start the BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below.
- When the screen as shown above displays, use the arrow keys to select the item "Proceed with flash update" and press the
key. You will see the BIOS recovery progress as shown in the screen below.
Note: Do not interrupt the BIOS flashing process until it has completed.

text_image
Auto Setup Utility - Copyright (C) 2017 American Megatrends, Inc. WARNING System firmware is being updated. Keyboard is locked. DO NOT TURN THE POWER OFF III Drive firmware update is completed press any key to reboot the system Program new data Write new boot block... 178 +: Select Screen T4: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save a Exit ESC: Exit Version 2.15.1266. Copyright (C) 2017 American Megatrends, Inc.- After the BIOS recovery process is completed, press any key to reboot the system.

text_image
Auto Setup Utility - Copyright (C) 2017 American Regatrends, Inc. Recovery WARNING System firmware is being updated. Keyboard is locked. DO NOT TURN THE POWER OFF !!! Once firmware update is completed press any key to reboot the system Flash update Flash update completed. Press any key to reset the system #: Select Screen T#: Select Item Enter: Select +/-t Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.15.1266. Copyright (C) 2017 American Regatrends, Inc.- Using a different system, extract the BIOS package into a USB flash drive.
- When a DOS prompt appears, enter FLASH.BAT BIOSname.### at the prompt.
- Press
continuously to enter the BIOS setup utility. Set the item, Boot Option #1, to [UEFI AP:UEFI: Built-in EFI Shell]. Pressto save the settings and exit the BIOS setup utility.

text_image
Boot Configuration Boot mode select [DUAL] LESACY to EFI support [Disabled] FIXED BOOT OK/OK Priorities Boot Option #1 [UEFI MP/UEPI: Max...] Boot Option #2 [CD/DVD] Boot Option #3 [USB Hard Disk] Boot Option #4 [USB CD/DVD] Boot Option #5 [USB Key/SenDisk] Boot Option #6 [USB Floppy] Boot Option #7 [USB Lan] Boot Option #8 [Network: IBM GE SI...] Boot Option #9 [UEFI Hard Disk] Boot Option #10 [UEFI CD/DVD] Boot Option #11 [UEFI USB Hard Disk] Boot Option #12 [UEFI USB CD/DVD] Boot Option #13 [UEFI USB Key/UEFI...] Boot Option #14 [UEFI USB Floppy] Boot Option #15 [UEFI USB Lan] Boot Option #16 [UEFI Network] Boot Option #17 [Hard Disk] Add New Boot Option Sets the system boot order **: Select Screen T4: Select Item Enter Select +/-: Change Opt. F1: General Hold F2: Previous Values P3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.19.1266. Copyright 4C 2017 American Megatrends, Inc.- When the UEFI Shell prompt appears, type fs# to change the device directory path. Go to the directory which contains the BIOS package extracted earlier from Step 7. Enter flash.nsh BIOSname.### at the prompt to start the BIOS update process.

text_image
UEFI Interactive Shell v2.1 ESK II UFI v2.50 (American Regatrends, 0x00s000c) Mapping table F50: Ailo(s):HD(0x0):BLK1; Pc(Aoort(x0):Pci(0x14,x0):/USB(0x11,x0):HD(II,HER,x0)79b1D72,0x806,0x1 (X3532) BLK0: Ailo(s): Pc(Aoort(x0):Pci(0x14,x0):/USB(0x11,x0): Press log is 1 seconds to skip startup.msh or any other key to continue. Shell: F50 F50: CD BLDOG F50:VWLOOS> CD SKPMEZ_03562017 F50:VWLOOS/SKPMEZ_03562017\ flash.msh X13FM7.5XNote: Do not interrupt this process until the BIOS flashing is complete.

text_image
Done. [Access Oms Part Ex] Index 8x51: 0x18 Done. ********************************************************************** * Program BIOS and ME (including RDT) regions... ********************************************************************** AVI Firmware Update Utility v5.09.01.1317 Copyright ©2017 American Registrends Inc. All Rights Reserved. OPUD = 50662 Reading Flash ....... done - ME Data Size checking . ok - PFS checksums ....... ok - Check BookLayout ....... ok, Erasing Boot Block ....... done Updating Boot Block ....... done Verifying Boot Block ....... done Zrading Boot Block ....... 0x00/32000 (OD)- The screen below indicates that the BIOS update process is complete. Unplug the AC power cable from the power supply, clear the CMOS, and plug the AC power cable in the power supply again to power on the system.

text_image
Verifying Boot Block ......... done Erasing Main Block ......... done Updating Main Block ......... done Verifying Main Block ......... done Erasing NRAM Block ......... done Updating NRAM Block ......... done Verifying NRAM Block ......... done Erasing NCB Block ......... done Updating NCB Block ......... done Verifying NCB Block ......... done - FOR is locked, skip updating. - OBEA is locked, skip updating. - GBEB is locked, skip updating. - Successful Update Recovery Loader to OPRx!! - Successful Update MRSB((-) - Successful Update FTPR((-) - Successful Update factory data partitions!! - NE Entire Image update success!! WARNING : System must power-off to have the changes take effect! flash.nshv mv AfuEfix64.efi AfuEfix64.swc mv: moving fs0:\AfuEfix64.efi -> \AfuEfix64.swc - [ok] fs0:>- Press
continuously to enter the BIOS setup utility. - Press
to load the default settings. - After loading the default settings, press
to save the settings and exit the BIOS setup utility.
Appendix C
System Specifications
Processors
Intel Atom processor C3758
Chipset
Intel Atom SoC chipset
BIOS
AMI® UEFI BIOS
Memory
Supports up to 256GB of ECC RDIMM or 64GB of ECC/non-ECC UDIMM DDR4 memory in four DIMM slots
On select SKUs, 2400MHz modules can be used but will operate at a lower speed.
Note: See the memory section in Chapter 3 for details and our website for updates to supported memory.
SATA Controller
SoC controller for five SATA3 (6Gbps) ports
Hard Drives
Up to two 3.5" or four 2.5" fixed internal hard-disk drives
PCI Expansion Slots
One PCI Express 3.0 x4 slot
Two M.2 PCI Express 3.0 x2 slots (1 M-Key 2242/2280,1 B-Key 3042/2280)
Motherboard
A2SDV-8C-LN10PF; FlexATX form factor (9" x 7.25") (228.6 mm x 184.15 mm)
Chassis
SC505-203B (1U rackmount), (WxHxD) 17.2 x 1.7 x 9.8 in. (437 x 43 x 249 mm)
System Cooling
Up to three 4028mm 13K RPM 4-pin PWM fans
Power Supply
Model: PWS-203-1H
AC Input Voltages: 100-240 VAC
Rated Input Current: 15-12A (100-127 VAC) / 825-7A (200-240 VAC)
Rated Input Frequency: 50-60 Hz
Rated Output Power: 200W
Rated Output Voltages: +12V (16A), +5Vsb (2A), +5V (8A), +3.3V (8A), -12V (0.5A max.)
Operating Environment
Operating Temperature: 0° to 40° C (32° to 104° F)
Non-operating Temperature: -40^ to 70^ C ( -40^ to 158^ F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55032 Class A, EN 61000-3-2/3-3, CISPR 32 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe)
Other: VCCI-CISPR 32 and AS/NZS CISPR 32
Environmental: Directive 2011/65/EU and Delegated Directive (EU) 2015/863 and Directive 2012/19/EU
Perchlorate Warning
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate"
Appendix D
Standardized Warning Statements for AC Systems
D.1 About Standardized Warning Statements
The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components.
Read this appendix in its entirety before installing or configuring components in the Supermicro chassis.
These warnings may also be found on our website at http://www.supermicro.com/about/policies/safety_information.cfm.
Warning Definition

Warning! This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
警告の定義
この警告サインは危険を意味します。
Installation Instructions

Warning! Read the installation instructions before connecting the system to the power source.
設置手順書
Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A.
サーキット・ブレーカー
Power Disconnection Warning

Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components.
電源切断の警告
Equipment Installation

Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
機器の設置
Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. (This warning does not apply to workstations).
アクセス制限区域
Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
電池の取り扱い
Redundant Power Supplies

Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit.
冗長電源装置
Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing.
バックプレーンの電圧
Comply with Local and National Electrical Codes

Warning! Installation of the equipment must comply with local and national electrical codes.
地方および国の電気規格に準拠
Warning! Ultimate disposal of this product should be handled according to all national laws and regulations.
製品の廃棄
Warning! Hazardous moving parts. Keep away from moving fan blades. The fans might still be turning when you remove the fan assembly from the chassis. Keep fingers, screwdrivers, and other objects away from the openings in the fan assembly's housing.
ファン・ホットスワップの警告
Power Cable and AC Adapter

Warning! When installing the product, use the provided or designated connection cables, power cables, and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA-certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only.
電源コードとACアダプター
Standardized Warning Statements (Traditional Chinese)
Traditional Chinese versions of warning statements are included in this appendix.
安全警告(注意這些警告標誌)
問限用物質會情濾標,聲聲暗書
Declaration of the Presence Condition of the Restricted Substances Marking
| 設備名稱:工作站/Server 型號(型式):505-2(系列型號:SYS-5019A-FTN4)Equipment name Type designation (Type) | ||||||
| 單元(Unit) | 現物質及其化學符號Restricted substances and its chemical symbols | |||||
| 鉛Lead(Pb) | 汞Mercury(Hg) | 錸-Cadmium(Cd) | 六維錸Hexavalent chromium( Cr^16 ) | 多溴聯苯Polybrominated biphenyls(PBB) | 多溴二苯醚Polybrominated diphenyl ethers(PBDE) | |
| 機器(Chassis) | ○ ○ | ○ ○ ○ | ||||
| 機器壓器(Chassis Fan) | - | ○ ○ | ○ ○ | |||
| 銅材(Cable) | ○ ○ | ○ ○ ○ | ||||
| 主機板(Motherboard) | - | ○ ○ | ○ ○ | |||
| 電源供應器(Power Supply) | - | ○ ○ | ○ ○ | |||
| 硬碟(Hard Disk) | - | ○ ○ | ○ ○ | |||
| 備考1.“超出0.1 wt%”及“超出0.01 wt%”係指現物質之百分比含量超出百分比含量基準值。Note 1.“Exceeding 0.1 wt%”and“exceeding 0.01 wt%”indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.備考2.“○”係指該項現物質之百分比含量大超出百分比含量基準值。Note 2.“○”indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence.備考3.“-”係指該項現物質為排除項目。Note 3.The “-”indicates that the restricted substance corresponds to the exemption. | ||||||
Appendix F
Dual Boot Block
F.1 Introduction
This motherboard supports the Dual Boot Block feature, which is the last-ditch mechanism to recover the BIOS boot block. This section provides an introduction to the feature.
BIOS Boot Block
A BIOS boot block is the minimum BIOS loader required to enable necessary hardware components for the BIOS crisis recovery flash that will update the main BIOS block. An on-call BIOS boot-block corruption may occur due to a software tool issue (see image below) or an unexpected power outage during BIOS updates.
| AMI Firmware Update Utility vX.XX.XX Copyright (C)XXXX American Megatrends Inc. All Rights Reserved. |
| Reading flash . . . . . . . . . . . . . . . . . . . done -- ME Data Size checking . ok -- FFS checksums . . . . . . . ok Erasing Boot Block . . . . . . . . . . . . . done __Updating Boot Block . . . . . . . 0x00A91000 (13%) |
BIOS Boot Block Corruption Occurrence
When a BIOS boot block is corrupted due to an unexpected power outage or a software tool malfunctioning during BIOS updates, you can still reboot the system by closing pins 2 and 3 using a cap on jumper JBR1. When JBR1 is set to pins 2 and 3, the system will boot from a backup boot block pre-loaded in the BIOS by the manufacturer.
F.2 Steps to Reboot the System by Using Jumper JBR1
- Power down the system.
- Close pins 2-3 on jumper JBR1 and power on the system.
- Follow the BIOS recovery SOP listed in Appendix B.
- After completing the steps above, power down the system.
- Close pins 1-2 on jumper JBR1 and power on the system.