XPower

X-39AR - Heating XPower - Free user manual and instructions

Find the device manual for free X-39AR XPower in PDF.

📄 16 pages English EN Download 💬 AI Question
Notice XPower X-39AR - page 4
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about X-39AR XPower

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Heating in PDF format for free! Find your manual X-39AR - XPower and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. X-39AR by XPower.

USER MANUAL X-39AR XPower

natural_image Line drawing of a multi-free fan with visible blades and mounting base (no text or symbols)

Axial Fan Owner's Manual

Model:

X-39AR, X-47ATR

(115V 60HZ)

Read and save these instructions before use

XPower X-39AR - Axial Fan Owner's Manual - 1

text_image ETL C LISTED US

Intertek

www.xpower.com | 1-(855)-855-8868 | info@xpower.com

Safety Instructions

XPower X-39AR - Safety Instructions - 1

WARNING - READ AND SAVE THIS INSTRUCTION BEFORE USING THIS PRODUCT.

The user of electrical products may create hazards that include, but are not limited to injury, fire, electrical shock. Failure to follow these instructions may damage and/or impair its operation and void the warranty.

  • Before operating, remove all packaging material and check for any damage that may have occurred during shipping or any missing items.
  • Check household power supply to ensure it matches the appliance's specification.
  • DO NOT operate any fan with a damaged cord or plug. Discard fan or return it to an authorized service facility for examination and/or repair.
  • Use only on GFCI protected receptacles. Please contact a qualified electrician for verification and / or installation of a GFCI receptacle if necessary.

- DO NOT run cord under carpeting. DO NOT cover cord with throw rugs, runners, or similar coverings. DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.

- Suitable for use with solid state speed control.

- DO NOT touch this appliance or the plug with wet hands or while standing in water.

- DO NOT operate the appliance in any pooled water.

- DO NOT use the product in areas where gasoline, paint or other flammable goods and objects are used or stored.

- DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the appliance and void the warranty.

- DO NOT cover the air inlet or outlet on the appliance.

- DO NOT direct the air flow at human faces or bodies.

- DO NOT allow children to play with this appliance.

- AUTOMATICALLY OPERATED DEVICE – To reduce the risk of injury, disconnect from power supply before servicing.

- Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug-end only, DO NOT pull the cord directly.

- DO NOT attempt to repair or adjust any electrical or mechanical functions of this appliance, as this may cause danger and void the warranty.

- If the appliance is damaged or it malfunctions, DO NOT continue to use it. Unplug the product from the electrical outlet. Refer to troubleshooting guide or contact XPOWER.

- Store in a dry area, away from exposure to sunlight, extreme temperature and humidity, or other extreme environments, when not in use.

- DO NOT stack more than five units of this appliance.

- An electronic instruction manual can be obtained through manufacturer's website www.xpower.com.

Items Included

XPower X-39AR - Items Included - 1

natural_image Technical line drawing of a mechanical fan or impeller assembly (no text or symbols)

XPower X-39AR - Items Included - 2

natural_image Line drawing of a multi-free fan with visible blades and mounting base (no text or symbols)

XPower X-39AR - Items Included - 3

- Owner's Manual x 1 • Axial F

XPower X-39AR - Items Included - 4

natural_image Technical line drawing of a mechanical clamp or bracket (no text or symbols)

XPower X-39AR - Items Included - 5

XPower X-39AR - Items Included - 6

- Rack x 1* • Rack Handle x 2* • Rubber Washer x 2*

* For model X-39AR only. ** For model X-47ATR only.

Parts Description

XPower X-39AR - Parts Description - 1

text_image Exploded view diagram of a fan assembly with numbered parts for identification

(1) Front Grille Cover
(2) Motor
(3) Housing
(4) Additional Electrical Receptacle
(5) Capacitor

(6) Housing Handle
(7) Switch Plate
(8) Rack Handle
(9) Rubber Washer
(10) Rack
(11) Circuit Board

(12) Fan
(13) Rear End Cover
(14) Rear Grille Cover
(15) Power Cord

Axial Fan Introduction

  • XPOWER Axial Fans are designed to offer efficient air circulation and ventilation with its high and long-distance focused airflow.
  • It's perfect for air circulation and ventilation in janitorial/sanitation jobs, water damage restoration and more.

XPower X-39AR - Axial Fan Introduction - 1

natural_image Line drawing of a multi-free fan with visible blades and mounting base (no text or symbols)

Installation and Operation Guide

Installing the Rack\*

XPower X-39AR - Installing the Rack\* - 1

text_image Technical diagram of a fan assembly with numbered components and directional arrows indicating motion or flow.

① Fit both rubber washers onto bolts on both sides of unit.
② Align the rack onto the axial fan.
③ Fasten the connection with the rack handle.

* For model X-39AR only.

Switch Plate

XPower X-39AR - Switch Plate - 1

pie | Category | Value | | -------- | ----- | | MAX | 1 | | OFF | 1 | | LOW | 1 |

Variable Speed Switch

  • Turn to "OFF" position to switch the Axial Fan OFF. Turn clock-wisely to any position between "MAX" and "LOW" to switch the Axial Fan ON.
  • You can adjust to any desired speed variably. "MAX" is the highest speed and "LOW" is the lowest speed.

Installation and Operation Guide (Continued)

Additional Electrical Receptacle (Daisy Chain)

XPower X-39AR - Additional Electrical Receptacle (Daisy Chain) - 1

text_image CIRCUIT BREAKER 12A TOTAL OUTPUT 12 AMPS MAX WITH THIS UNIT OFF 10 AMPS MAX WITH THIS UNIT ON
  • Other appliances can be plugged in the additional electrical receptacles and work whether the Axial Fan is on or off. However, the total amperage must be lower than the amperage instructed. Different models may have varying instructions.
  • If the Axial Fan or the plugged in appliance stops working, press the RESET BUTTON to reset the circuit.

Timer Switch\*

XPower X-39AR - Timer Switch\* - 1

text_image 0 60 120 180 ON

Timer Switch

  • Turn clockwise to set timer for minutes count down to an automatic stop.
  • The timer can be set for up to 180 minutes (3 hours).
  • When the timer reaches "0" position, the unit stops working. On "ON" position, it will work constantly.

Installation and Operation Guide (Continued)

Adjust Operation Position

XPower X-39AR - Adjust Operation Position - 1

natural_image Line drawing of a multi-free fan with visible blades and mounting base, showing rotational motion arrows (no text or symbols)

XPower X-39AR - Adjust Operation Position - 2

natural_image Technical line drawing of a mechanical device with bidirectional arrows indicating rotation or assembly (no text or symbols)

- The Axial Fan features 360° Rotation. Tilt the Axial Fan to desired angle and screw on rack handles to secure the fan's position.

XPower X-39AR - Adjust Operation Position - 3

flowchart
graph TD
    A["Start"] --> B{Loop Back}
    B -->|Yes| C["Process Unit"]
    B -->|No| D["End"]

XPower X-39AR - Adjust Operation Position - 4

natural_image Abstract diagram of a mechanical component with multiple directional arrows radiating outward (no text or symbols)

XPower X-39AR - Adjust Operation Position - 5

flowchart
graph TD
    A["Device with top panel"] --> B{Return Path}
    B -->|Upward Arrow| C["Process"]
    B -->|Downward Arrow| D["End"]
    C --> E["Return Path"]
    D --> F["End"]

XPower X-39AR - Adjust Operation Position - 6

natural_image Technical line drawing of a mechanical fan or fan assembly with helical blades (no text or symbols)

Use without Rack\*

- Uninstall the rack and place the Axial Fan on a level surface.

* For model X-47ATR only.

Installation and Operation Guide (Continued)

Transportation

XPower X-39AR - Transportation - 1

natural_image Line drawing of a fan with internal blades and a hand holding the top handle (no text or symbols)

Lift with Handle

- Lift the Axial Fan with the handle on the top.

User Maintenance Instructions

Frequent maintenance is recommended on this appliance. Failure to follow the maintenance instructions may cause failure of the appliance and void the warranty.

  • When not in use, unplug and store the appliance in a dry and cool indoor place. Make sure it's out of reach of children.
  • Before performing any maintenance or cleaning, always disconnect the Axial Fan from its power source.
  • Use a damp cloth to wipe the surface of the housing. Do not clean the unit with water directly.
  • Check if the grille covers are clean. Remove dirt or any other objects that could block the air inlet and air outlet.

User Maintenance Instructions (Continued)

XPower X-39AR - User Maintenance Instructions (Continued) - 1

natural_image Line drawing of a multi-free fan with visible blades and rotating blades (no text or symbols)

Fasten the Rack Handles

• To prevent possible injury, when you finish using this appliance, please position the Axial Fan UPRIGHT.

- Fasten the rack handle to lock the position of the Axial Fan.

XPower X-39AR - Fasten the Rack Handles - 1

natural_image Diagram of a fan with rotating blades and a black spiral motion arrow (no text or symbols)

XPower X-39AR - Fasten the Rack Handles - 2

natural_image Two identical diagrams showing a plug with pins and wires, one increasing and the other decreasing (no text or symbols)

Organize the Power Cord

  • Wrap the power cord around the housing.
  • Clip the cord to the cord clip on the plug shown above.

User Maintenance Instructions(Continued)

XPower X-39AR - User Maintenance Instructions(Continued) - 1

natural_image Technical line drawing of a multi-tiered mechanical assembly with no visible text or symbols

Stack Multiple Units

- Stack the Axial Fans on the sides. Align the air inlets of both Axial Fans.

! WARNING

  • Do not stack more than five units of this appliance.
  • Stacking function is not secure during transportation.

Troubleshooting Guide

PROBLEM POSSIBLE CAUSE SOLUTION

Axial fan does not startNo electricity. Check for power supply.
The power cord is not properly plugged in.Remove and reconnect the power cord.
The circuit breaker on the additional electrical receptacle (Daisy chain) jumps.Remove all appliance on the additional electrical receptacle and press “Reset”.
The timer switch is set to “0” position.*Set the timer switch to “ON” position.
Unit runs but the speed is abnormalAir inlet or air outlet is blocked. Remove blockage.

* The timer function does not apply to all models mentioned in this manual.

If troubleshooting does not resolve your problem, please contact XPOWER or other parties authorized by XPOWER for further instructions.

Technical Specification

MODEL NUMBER X-39AR X-47ATR
Voltage/Frequency 115 V~60 Hz
Amperage 1.6 A 2.8 A
Motor Power 1/4 HP 1/3 HP
Rated Airflow 2100 CFM 3600 CFM
Speed Control Variable Speeds
Timer N/A 3 hours (OFF)
Additional Electrical Receptacles (Daisy Chain)Yes
Cord Length20 ft. / 6.1 m
HousingABS
Unit Dimension (L) x (W) x (H)18.6 x 9.4 x 19.2 in. / 47.2 x 23.9 x 48.8 cm21.9 x 9.8 x 22.5 in. / 55.6 x 24.9 x 57.1 cm
Unit Weight16.5 lbs. / 7.5 kg22.2 lbs. / 10.1 kg
Safety CertificationETL/C-ETL

If your product(s) is not listed above, please visit www.xpower.com for more information.

XPOWER Limited Warranty (USA)

1 YEAR LIMITED WARRANTY

XPOWER-branded products purchased in the U.S. from authorized distributors include a 1-year limited warranty. Contact XPOWER to confirm warranty information about your product(s).

This limited warranty covers defects in materials and workmanship in your XPOWER-branded products, purchased in the U.S. ONLY. Local warranty policy (if any) in your country will cover products purchased outside the U.S.

XPower X-39AR - YEAR LIMITED WARRANTY - 1

IMPORTANT:

(1) Please finish the online warranty registration before usage. Visit www.xpower.com/service-support/warranty-registration.
(2) This Limited Warranty applies with its own timeliness. Contact XPOWER or visit www.xpower.com for more information.

Items mentioned but not limited to below are not covered by warranty:

(1) Power cord, filters or any other components considered as a “consumable parts” by XPOWER.
(2) Normal wear and tear.
(3) Problems that result, directly or indirectly, at XPOWER's sole discretion, from:

(3.1) External causes such as accident, abuse, misuse or problems with electrical power supply.
(3.2) Disassembling, servicing or modification not authorized by XPOWER.
(3.3) Usage that is not accordant with product instructions stated in Owner's Manual.
(3.4) Failure to follow the product instructions or lack of necessary maintenance stated in Owner's Manual.

Before contacting XPOWER, please try one or more of the following:

(1) Consult this Owner's Manual and follow the instructions of troubleshooting guide.
(2) Access www.xpower.com for more advice and information that could be helpful to address your problems.

If you need additional assistance from XPOWER, please:

(1) Email info@xpower.com.
(2) Call XPOWER U.S. Customer Service Department at 855-855-8868 or other numbers provided on www.xpower.com.
(3) Visit XPOWER U.S. Head Office at 240 Clary Ave., San Gabriel, CA 91776 or the most current address provided on www.xpower.com.

Please also have your original proof of purchase and the serial number(s) of your product(s) ready when you contact XPOWER.

XPOWER Limited Warranty (USA) (Continued)

If you are instructed to return the unit for service or replacement, please:

(1) Request a RMA (Return-Merchandise-Authorization) number.
(2) Use the original or an equivalent packaging, prepay shipping charges at your own expense to the address provided by XPOWER, with the RMA number on the shipping label or the packaging.
(3) Include all the original parts and components.

XPOWER will inspect, assess and advise the repairs needed and applicable cost, if any. For products under warranty, we will pay to ship the repaired or replaced product(s) to you if you use an address within the Contiguous United States. Otherwise, we will ship the product(s) to you at your own expense.

XPower X-39AR - If you are instructed to return the unit for service or replacement, please: - 1

XPOWER®

XPOWER Manufacture, INC.

240 Clary Avenue

San Gabriel, CA 91776 USA

www.xpower.com | 1-(855)-855-8868 | info@xpower.com

Read and save these instructions before use

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : XPower

Model : X-39AR

Category : Heating