P-130A - Heating XPower - Free user manual and instructions
Find the device manual for free P-130A XPower in PDF.
User questions about P-130A XPower
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Heating in PDF format for free! Find your manual P-130A - XPower and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. P-130A by XPower.
USER MANUAL P-130A XPower
natural_image
Gray industrial fan or air purifier device with control panel and ventilation slots (no visible text or symbols)
Intertek

XPOWER®
PROFESSIONAL AIR MOVER
OWNER'S MANUAL
Model: P-100A / P-130A
(115V / 60Hz)
XPOWER Manufacture, Inc.
240 Clary Avenue
San Gabriel, CA 91776, USA
Tel: 626-285-3301, Fax: 626-285-3302
website: xpower.com
PLEASE READ AND SAVE THESE INSTRUCTIONS
Index
Introduction 2
Operation 3
Safety Instructions 4
Maintenance Instructions/ Troubleshooting 5
Specification 6
Warranty / Service 7
Parts List 8
Warranty Registration Form 10
Introduction
XPOWER Mini Air Movers P-100A and P-130A are certified professional level multifunctional utility blower fans with the most efficient engineering design for retail market.
Features:
- Low power draw with high velocity air flow from 500 to 700 CFM.
• Super quiet motor and super lightweight. - Easy carrying handle and stackable up to 4 units high.
- Easy and quick to disassemble for thorough cleaning and service.
- Safety certified 10' power cord.
- Easy cord wrap on handle.
- 3-speed switch.
• Durable and rugged housing. - 4 air flow positions (0°, 20° Kickstand, 45° and 90°).

natural_image
Four grayscale images of a fan-shaped object at 0°, 20°, 45°, and 90° angles (no text or symbols on the objects themselves)AIR MOVER STORAGE:
Air Movers can be stacked (up to 4) on their sides for storage.
NOTICE:
Stacking feature is not secure for transportation.

natural_image
Close-up of a mechanical device with multiple ports and buttons (no visible text or symbols)Operation
XPOWER Mini Air Movers are intended to move air and to dry small areas where the large air mover is not applicable such as crawl spaces, inside cabinets, under counters, inside ceilings, basements, etc. The Mini Air Mover can also be used as a high velocity fan for household use.
- XPOWER air movers are shipped ready-to-use. Prior to plugging the unit into the power source, inspect completely for any shipping damage.
- Plug the electrical cord into the power outlet.
- Carefully place the Air Mover on a stable, flat, dry surface.
- The unit is capable to be used at 4 different angles to direct airflow.
- Turn the switch to select desired speed, while making sure the unit operates normally.
- To reduce the risk of injury, close supervision is necessary when the appliance is used near children. Do not allow children to play with or around an air mover at any time.

text_image
CIRCUIT BREAKER 12A TOTAL OUTPUT 12 AMPS MAX WITH THIS UNIT OFF 3.5 AMPS MAX WITH THIS UNIT ON AUXILIARY OUTLET 119 VOLTS ACDaisy-chain Feature
If utilizing the Daisy-chain feature, only allow up to two additional air movers or other devices running together on total 12 AMPs circuit. P-100A & P-130A air movers have an on-board circuit breaker. If the auxiliary outlet overloads, the circuit breaker will trip. If the breaker does trip, unplug the units and press the circuit breaker Reset button. Plug the units back into the power source and turn on the switch.
Safety Instructions
- To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug the unit with wet hands or while standing in water.
- To avoid risk of injury, do not direct air flow at face or body.
- To reduce the risk of fire or electric shock, do not use the Mini Air Mover with any solid-state speed control device.
- Use only with GFCI protected receptacles. Please contact a qualified electrician for verification and / or installation of a GFCI receptacle if necessary.
- Do not operate the Mini Air Mover with a damaged cord or plug. Discard the unit or return it to an authorized service facility for examination and/or repair.
- Unplug the Mini Air Mover from the power supply before servicing or cleaning. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs, runners, or similar coverings. Place the power cord away from traffic area to prevent tripping.
- Do not allow children to play with or around the Mini Air Mover at any time.
- Do not move or carry the Mini Air Mover while the unit is operating.
- To reduce the risk of injury, close supervision is necessary when an appliance is used near children.
- An electronic instruction manual can be obtained through manufacture's website: xpower.com.
Maintenance Instructions
- Always disconnect the air mover from its power source before performing any maintenance or cleaning.
- Never clean the unit with water directly.
- When not in use, unplug and store the air mover in a dry indoor place out of reach of children.
- To keep the Mini Air Mover clean, use a damp cloth to wipe the surface of the housing.
Troubleshooting
For any problems not listed below, call your local distributor or contact our Service Department at 1-855-855-8868
| PROBLEM | POSSIBLE CAUSE | SOLUTION |
| Air Mover not running | No power input | Plug in the Air Mover; check circuit breaker |
| Switch not turned on | Turn on switch | |
| Air Mover fan wheel jammed | Remove material jamming fan wheel | |
| Intake or exhaust blocked | Turn unit off and allow to cool, then remove blockage | |
| Air Mover vibrates | Accumulation of dirt on fan blades | Clean Air Mover fan blades |
Specifications
| Model P-100A P-130A | ||
| Volt / Frequency 115V / 60Hz 115V / 60Hz | ||
| Power 1/8 HP 1/5 HP | ||
| Amp 1.5 Amps 2.0 Amps | ||
| Rated Airflow (On High) | 500 CFM | 700 CFM |
| RPM (Low / Medium / High) | 650 / 950 / 1200 | 1000 / 1250 / 1500 |
| Speeds Three | Three | |
| Built-In Power Outlet / Daisy Chain | Yes | Yes |
| Positions | 4 (0°, 20° Kickstand, 45°, 90°) | 4 (0°, 20° Kickstand, 45°, 90°) |
| Unit / Box Weight | 9.5 Lbs. / 11.2 Lbs. | 9.3 Lbs. / 11.0 Lbs. |
| Unit / Box Size (L x W x H) | 10.7"x12.4"x13.3" / 13.6"x12.8"x11" | 10.7"x12.4"x13.3" / 13.6"x12.8"x11" |
| Power Cord (Length/Size) | 10'/14AWG | 10'/14AWG |
| Overheating Protection | Thermally Protected | Thermally Protected |
| Housing | Injection Mold / Polypropylene (PP) | Injection Mold / Polypropylene (PP) |
| Safety Certificates | ETL / C-ETL | ETL / C-ETL |
XPOWER Limited Warranty (USA)
XPOWER's Limited Warranty covers the unit (excluding POWER CORD) from defects in material and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. Non-contiguous states must pay for roundtrip freight. A purchase receipt must be provided.
Important!
This warranty does not cover or apply to defects due directly or indirectly to misuse, abuse, disassembly, alteration, corrosive chemicals, improper voltage, fire, flood, negligence, accident, improperly or incorrectly performed maintenance or repair, or failure to perform necessary maintenance or repair, or if the use of this product is not in compliance with the instructions and specifications for its use.
Service
For Warranty service and parts replacement (US users only), you must:
A. Call 1-855-855-8868 for a RMA (Return-Merchandise-Authorization) number.
B. Have original proof of purchase.
C. Use the original undamaged packaging or an industrial certified packaging method.
End user will be responsible to ship the unit (with RMA Number showing on the shipping label) to the XPOWER Service Department. XPOWER will inspect, assess and advise the repairs needed and the applicable cost, if any. For users outside the US, please contact an XPOWER Distributor in your country or region for Warranty service and parts replacement.
100 Series Parts List
| Item No. | Parts Name | Item No. | Parts Name |
| 1 | Grid Cover (Motor Side) | 2 | Left Housing |
| 3 | Switch Knob | 4 | Switch Plate |
| 5 | Switch | 6 | Motor |
| 7 | Fan | 8 | Power Cord |
| 9 | Right Housing | 10 | Grid Cover (Fan Side) |
| 11 | Air Outlet Grid Cover | 12 | Kick Stand |
| 13 | Rubber Feet (Not Shown) | 14 | Screws and Nuts (Not Shown) |
| 15 | Capacitor |

text_image
Technical diagram of an electric motor assembly with numbered components and directional arrows indicating parts of each part.XPOWER Retail Product Line
Airrow Pro Multi-Use Duster: A-2
Pet Dryers: B-2, B-53, B-55
Air Pump: AP-1031A, AP-1131, AP-138A, AP-145A
Air Movers: P-100A, P-130A, P-200AT, P-230AT

natural_image
Exterior view of a gray XPOWER handheld tool with black handle and spout (no text or symbols on body)A-2
Scented Air Movers: P-150N, P-250AT, P-250NT, P-260AT, P-260NT
Inflatable Blowers: BR-2C01A, BR-201A, BR-232A, BR-252A

natural_image
Black industrial fan or motor housing with ventilation grille (no visible text or symbols)BR-2C01A

natural_image
Close-up of a black cylindrical device with attached wires and a connector, no visible text or symbols.AP-1031A

natural_image
Exterior view of a gray XPOWER air purifier with black hose (no text or symbols visible)B-55
Warranty Registration (for US user only)
For your product warranty, please complete and mail / fax this form to XPOWER MANUFACTURE, INC.
Address: 240 Clary Ave., San Gabriel, CA 91776.
Tel: 626-285-3301
Fax: 626-285-3302
(For your convenience, register your product online at xpower.com
Company Name / Contact Person / Title
Address
City
State / Province ____ Zip Country ____
Phone ____ Fax ____ E-mail
Model # ____ Serial #:
Date of Purchase ____/____/____ Purchased From
Additional Comments / Suggestions
From:

natural_image
Empty white square with black border (no text or symbols)TO:
XPOWER Manufacture, Inc.
240 Clary Avenue
San Gabriel, CA 91776, USA

XPOWER®
