Download the instructions for your Heating in PDF format for free! Find your manual P-260AT - XPower and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. P-260AT by XPower.

USER MANUAL P-260AT XPower

P-150N, P-250NT, P-260NT, P-450NT (115V/60Hz)

XPOWER MANUFACTURE, INC.

240 Clary Avenue

San Gabriel, CA 91776, USA

Tel: 626-285-3301 Fax: 626-285-3302

www.xpower.com

PLEASE READ AND SAVE THESE INSTRUCTIONS

XPower P-260AT - 1

natural_image Blue industrial fan with control panel and cooling unit, no visible text or symbols on device body

XPower P-260AT - 2

Intertek

INDEX

Introduction 2

Operation 3

Safety Instructions 4

Specifications 5

Parts List 6

Maintenance/Troubleshooting 7

Products & Accessories 8

Warranty/Service 9

Warranty Registration Form 10

INTRODUCTION

Use XPOWER Scented Air Movers with Anion switch to enhance ambiance and indoor air quality. A patented scent cartridge quickly fragrances the air and is easily refilled with a scented bead fragrance of your choice. The unit's built in ionizer generates revitalizing negative ions to reduce pollutants such as airborne dust, allergens, and malodors. Enjoy a boosted energy/mood as ionized air helps to increase oxygen flow and decrease fatigue. Available in models from 1/8 HP to 1HP, these professional level multifunctional utility air movers are precision built for efficient ventilating and drying.

Industry Leading Design

SuperQuiet Motor
Lightweight
- Easy Carrying Handle
♦ Rugged Housing
◆ 3-Hour Timer (except P-150N)
- 3 or 4 Speed Switch

Multiple Applications /Uses

Jan/San
◆Hotels/Hospit ality
- Spas & Salon s
♦ Retail
♦Gyms & Fitne ss Centers
Home

What's inside: Air M over, Refillable Scented Bead Cartridge, Line Scented Bead Sample

20°(kickstand)45°90°

AIR MOVER STORAGE:

Air Movers can be stacked (up to 4) on their sides for storage.

NOTICE:Stacking feature is not secure for transportation.

XPower P-260AT - INTRODUCTION - 1

OPERATION

READ ALL INSTRUCTIONS BEFORE OPERATING

  1. Prior to plugging the unit into the power source, inspect completely for any shipping damage.
    2.Plug the electrical cord into the power outlet.
  2. Carefully place the unit on a stable, flat, dry surface.
  3. Position unit to desired angle to direct air flow.
  4. Turn switch to desired speed.
  5. To generate negative ions, flip green anion switch from OFF (O) position to ON (—).
  6. Make sure unit operates normally and air flow vents are not obstructed.
  7. To reduce the risk of injury, close supervision is necessary when an appliance is used near children. Do not allow children to play with or around an Air Mover at any time.

SETTING OPTIONAL TIMER

Turn dial to select

desired time

(1-180 minutes)

"ON" p osition sets

unit for continuous use

** No Timer feature for P-150N

SPEEDS

XPower P-260AT - SETTING OPTIONAL TIMER - 1

text_image ON 100 100 OFF 3 XPOWER™

FILLING SCENTED CARTRIDGE

  1. Remove scent cartridge from the air mover by turning counter-clockwise while unit is positioned facing you.

  2. Flip hinged top open.

3.Open scented bead packet sample that is included with your purchase.

  1. Fill cartridge according to the scent intensity desired.

  2. Reassemble by screwing cartridge back into the unit clock-wise.

XPower P-260AT - FILLING SCENTED CARTRIDGE - 1

WARNING: KEEP OUT OF REACH OF CHILDREN

SAFETY INSTRUCTIONS

XPower P-260AT - SAFETY INSTRUCTIONS - 1

WARNING - TO REDUCE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

  1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug the unit with wet hands or while standing in water.
  2. To avoid risk of injury, do not direct air flow at face or body.
  3. To reduce the risk of fire or electric shock, do not use the Air Mover with any solid-state speed control device.
  4. Use only with GFCI protected receptacles. Please contact a qualified electrician for verification and/or installation of a GFCI receptacle if necessary.
  5. Do not operate the Air Mover with a damaged cord or plug. Discard the unit or return it to an authorized service facility for examination and/or repair.
  6. Unplug the Air Mover from the power supply before servicing or cleaning.
  7. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs, runners, or similar coverings. Place the power cord away from traffic area to prevent tripping.
  8. Do not allow children to play with or around the Air Mover at any time.
  9. Do not move or carry the Air Mover while unit is operating.
  10. It's Automatically Operated Device, To Reduce The Risk Of Injury Disconnect From Power Supply Before Servicing.

PART LIST

Item No.Parts NameItem No.Parts Name
1 NegativeIon Switch2 Capacitor
3Negative Ion GeneratorGrid Cover (Motor Side)4
Left Housing56Switch & Timer plate
7-1 / 7-2Switch / Timer (except P-150N)8-1 / 8-2Switch / Timer Knob (except P-150N)
9Motor10Power Cord
11Fan12Right Housing
13Grid Cover(Fan Side)14Fragrance Cartridge
15Air Outlet Grid Cover16Kick Stand
17 RubberFeet (Not Shown)18Screws and Nuts (Not Shown)

XPower P-260AT - WARNING - TO REDUCE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: - 1

text_image Exploded view diagram of an electric motor assembly with numbered parts for identification

SPECIFICATIONS

ModelP-150NP-250NTP-260NTP-450NT
Volt / Frequency115V / 60Hz
Power 1/8 HP 1/3 HP1/5 HP
Amp 1.5 Amps 3.8 Amps2.3 Amps
Rated Airflow (On High) 700 CFM 2000 CFM800 CFM
RPM 650/950/1200 1000/1250/1500 450/650/1100/1500 1000/1350/1600
SpeedsThreeFourThree
Unit / Box Weight (LBS)9.1 / 10.89.9 / 11.110.0 / 11.2
Unit / Box Size (L "x W" x H")10.7x12.4x13.3 / 13.6x12.8x1113.9x14.8x14.6 /15.5x15x15.2
Power Cord (Length/Size)10'/18 AWG20'/18AWG
3-Hour TimerNo
Negative Ion SwitchYes
Positions4 (0°, 20° Kickstand, 45°, 90°)
Overheating ProtectionThermally Protected
HousingInjection Mold / Polypropylene (PP)
Safety CertificatesETL / C-ETL

MAINTENANCE/TROUBLESHOOTING

  1. To keep unit clean, use a damp cloth to wipe the surface of the housing.
  2. Never clean Air Mover by rinsing or spraying directly with water.
  3. When not in use, unplug and store unit in a dry indoor place out of reach of children.
  4. Always disconnect Air Mover from its power source before performing any maintenance or cleaning.

For any problems not listed below, call your local distributor or contact the XPOWER Service Department.

PROBLEMPOSSIBLE CAUSESOLUTION
Air Mover not runningNo power inputPlug in the Air Mover & check
Switch not turned onTurn on switch
Air Mover fan wheel jammedRemove material jamming fan wheel
Intake or exhaust blockedTurn unit off and allow to cool, then remove blockage
Air Mover vibratesAccumulation of dirt on fan bladesClean Air Mover fan Blades

XPOWER LIMITED WARRANTY (USA)

XPOWER's Limited Warranty covers the unit (excludes POWER CORD) from defects in material and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. Non-contiguous states must pay for roundtrip freight. A purchase receipt must be provided.

Important!

This warranty does not cover or apply to defects due directly or indirectly to misuse, abuse, disassembly, alteration, corrosive chemicals, improper voltage, fire, flood, negligence, accident, improperly or incorrectly performed maintenance or repair, or failure to perform necessary maintenance or repair, or if the use of this product is not in compliance with the instructions and specifications for its use.

Service

For Warranty service and parts replacement (US users only), you must:

A. Call 1-855-855-8868 for a RMA (Return-Merchandise-Authorization) number.
B. Have original proof of purchase.
C. Use the original undamaged packaging or an industrial certified packaging method.

End user will be responsible to ship the unit (with RMA Number showing on the shipping label) to the XPOWER Service Department. XPOWER to inspect, assess and advise the repairs needed and the applicable cost, if any. For users outside the US, please contact XPOWER Distributor in your country or region for Warranty service and parts replacement.

PRODUCTS & ACCESSORIES

Visit www.xpower.com for Complete Product Selection

  • Air Movers Axial Fans Air Scrubbers Dehumidifiers
  • Pet Force Dryers Pet Stand Dryers Cage-Dryers Inflatable Blowers

Additional Scented Bead Fragrances Available at Amazon.com and Airchaser.com (XPOWER master distributor)

XPOWER MANUFACTURER, INC. 240 Clary Avenue San Gabriel, CA, USA

Tel: 626-285-3301 Fax: 626-285-3302

Warranty Registration (for US user only)

For your product warranty, please complete and mail / fax this form to XPOWER MANUFACTURE, INC.

Address: 240 Clary Ave., San Gabriel, CA 91776. Tel: 626-285-3301 Fax: 626-285-3302

(For your convenience, register your product online at xpower.com)

Company Name / Contact Person / Title

Address ____ City ____

State / Province ____ Zip ____ Country

Phone ____ Fax ____ E-mail ____

Model # ____ Serial #: ____

Date of Purchase ____/____/____ Purchased From ____

Additional Comments / Suggestions

From: ____ ______ ____

TO:

XPOWER MANUFACTURE, INC.

240 Clary Avenue

San Gabriel, CA, USA

XPower P-260AT - Warranty Registration (for US user only) - 1

XPOWER®

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : XPower

Model : P-260AT

Category : Heating