MRCOOL

MAHM048ETA - Air-conditioner MRCOOL - Free user manual and instructions

Find the device manual for free MAHM048ETA MRCOOL in PDF.

📄 22 pages English EN Download 💬 AI Question
Notice MRCOOL MAHM048ETA - page 4
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about MAHM048ETA MRCOOL

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air-conditioner in PDF format for free! Find your manual MAHM048ETA - MRCOOL and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MAHM048ETA by MRCOOL.

USER MANUAL MAHM048ETA MRCOOL

Owner & Installation Manual

MRCOOL MAHM048ETA - Owner & Installation Manual - 1

natural_image Abstract black-and-white graphic of stylized animal-like shapes with curved and angular forms (no text or symbols)

MRCOOL®

COMFORT MADE SIMPLE

Signature Series

MAHM*ETA AIR Handler

INSTALLATION INSTRUCTIONS

MAHM\*ETA Series Air Handler

This manual must be left with the homeowner for future reference.

MRCOOL MAHM048ETA - MAHM\*ETA Series Air Handler - 1

This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals, be alert to the potential for personal injury or death.

MRCOOL MAHM048ETA - MAHM\*ETA Series Air Handler - 2

natural_image 3D rendering of a gray industrial cabinet or enclosure with visible internal components and mounting holes (no text or symbols)

Table of Contents

MAH*E Unit Dimensions – Upflow – Inches (mm)......2

Shipping and Packing List ....3

General....3

Requirements 3

Installation Clearances 4

Installation 4

Condensate Drain....6

Duct System and Filters 8

Brazing Refrigerant Lines....9

Sealing the Unit 11

Electrical Connections....11

Blower Performance Data 15

Air Flow - Cooling Blower Speed....16

Operation Inspection 16

Operation....17

Maintenance....17

Professional Maintenance 17

Cabinet Insulation....18

Use of Air Handler During Construction....18

MRCOOL MAHM048ETA - Table of Contents - 1

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a licensed professional HVAC installer or equivalent, service agency, or the gas supplier.

MRCOOL MAHM048ETA - WARNING - 1

CAUTION

As with any mechanical equipment, contact with sharp sheet metal edges can result in personal injury. Take care while handling this equipment and wear gloves and protective clothing.

MRCOOL MAHM048ETA - CAUTION - 1

IMPORTANT

The Clean Air Act of 1990 bans the intentional venting of refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992. Approved methods of recovery, recycling or reclaiming must be followed. Fines and/or incarceration may be levied for noncompliance.

Manufactured By

MRCOOL LLC

Hickory, KY 42051

*P507788-01C*

(P) 507788-01C

MAHM*ETA Unit Dimensions – Upflow – Inches (mm)
MRCOOL MAHM048ETA - IMPORTANT - 1

text_image 1 (25) 14-1/2 (368) C 1 (25) LINE VOLTAGE INLETS (Top and Left Side) TOP VIEW DETAIL OF PIPING PLATE 3/4 (19) SUCTION LINE LIQUID LINE 2-3/8 (60) 4-3/8 (111) 2-3/4 (70) 3-1/2 (89) 1-3/4 (44) 4-3/4 (121) CONDENSATE DRAINS (2) (Horizontal) CONDENSATE DRAINS (2) (Upflow and Downflow) LINE VOLTAGE INLETS (Top and Right Side) AIR FLOW CIRCUIT BREAKER COVER PIPING PLATE CONDENSATE DRAIN PIPING PLATE (3) (2-1/4 x 3-3/4) FILTER ACCESS A 1-1/8 (29) D 1-1/8 (29) OPENING 1/2 (13) 20-3/8 (518) 1-1/8 (29) OPENING 22 (559)

NOTE: Unit is shipped configured for horizontal right-hand air discharge. Unit may be converted to horizontal left-hand air discharge by repositioning horizontal drain pan. Dimensions remain the same in all configurations.

Dimensions024 030 036 /042 048 060
in. mmin. mm in.mm in. mmin. mm
A45-1/21156 471194 136255 1397 1518 53-5/859-3/4
B18-1/2470 470548 54954621-1/221-1/221-1/2
C16-1/2419 419495 49549519-1/219-1/219-1/2
D16-1/4413 413489 48948919-1/419-1/419-1/4

Shipping and Packing List

Package 1 of 1 contains:

1 – Assembled air handler unit factory-equipped for upflow or horizontal air discharge application (includes upflow and horizontal drain pans and pre-installed air filter).

Check the air handler for shipping damage; if found, immediately contact the last carrier. Check the unit rating plate to confirm that delivered unit matches order.

General

The MAHM*ETA series air handler with all-aluminum coil is designed for indoor installation only. As shipped, the unit is ready for installation in either upflow or horizontal right-hand air discharge applications. Horizontal drain pan may be repositioned in the field to allow installation in the horizontal left-hand air discharge position. Various accessories are available and listed in the MAHM*ETA Product Specification for ordering.

This instruction is intended as a general guide and does not supersede local or national codes in any way. Consult authorities having jurisdiction before installation.

NOTE: Special procedures are required for cleaning the all-aluminum coil in this unit. See Page 17 in this instruction for information.

Requirements

MRCOOL MAHM048ETA - Requirements - 1

WARNING

Excessive Weight Hazard - Use two or more people when moving and installing the unit. Failure to do so can result in back or other type of injury.

MRCOOL MAHM048ETA - WARNING - 1

IMPORTANT

MAHM*ETA units include a factory-installed check/expansion valve which will provide optimal refrigerant control and system performance with outdoor units of varying capacities. These units must be installed as a part of a matched system as outlined in the MAHM*ETA Product Specification.

These instructions are intended as a general guide and do not supersede local or national codes in any way. Consult authorities having jurisdiction before installation.

Compliance with all local, state, or national codes pertaining to this type of equipment should be determined prior to installation. Read this instruction manual, as well as the instructions supplied in separate equipment, before starting the installation.

In addition to conforming to manufacturer's installation instructions and local municipal building codes, installation of air handler units (with or without optional electric heat), MUST conform with National Fire Protection Association (NFPA) standards: "Standard for Installation of Air Conditioning and Ventilation Systems" (NFPA No. 90A) and "Standard for Installation of Residence Type Warm Air Heating and Air Conditioning Systems" (NFPA No. 90B).

All models are designed for indoor installation only. The installation of the air handler, field wiring, duct system, etc. must conform to the requirements of the National Electrical Code, ANSI/NFPA No. 70 (latest edition) in the United States, and any state laws, and local ordinances (including plumbing or waste water codes).

Local authorities having jurisdiction should be consulted before installation is made. Such applicable regulations or requirements take precedence over the general instructions in this manual.

Install the conditioned air plenum, ducts and air filters (provided) in accordance with NFPA 90B Standard for the Installation of Warm Air Heating and Air-Conditioning Systems (latest edition).

The air handler is shipped from the factory completely assembled. The unit is provided with flanges for the connection of the duct system.

Do not remove the cabinet knockouts until it has been determined which knockouts will need to be removed for the installation.

Select the air discharge position which best suits the site conditions. Consider required clearances, space, routing requirements for refrigerant line, condensate disposal, filters, duct system, wiring, and accessibility for service. Refer to the rating plate on the air handler for specific information.

MRCOOL MAHM048ETA - IMPORTANT - 1

MRCOOL MAHM048ETA - IMPORTANT - 2

WARNING

Danger of explosion. Keep flammable materials and vapors, such as gasoline, away from air handler. Place air handler so that heating elements are at least 18 inches (46 cm) above the floor for a garage installation. Failure to follow these instructions can result in death, explosion, or fire.

IMPORTANT

Excessive condensation may occur if the unit is installed in a warm, humid place. When the unit is installed in an unconditioned space, apply sealant around electrical wires, refrigerant piping and condensate lines at the point where they enter the cabinet.

Apply sealant on the inside of the cabinet at the point where the electrical wires exit through the conduit opening. This will also keep warm and moist unconditioned air out of the air handler cabinet where it will form condensate on the cooler control box and electrical controls.

IMPORTANT

This unit is approved for installation clearance to combustible material as stated on the unit rating plate. Accessibility and service clearances must take precedence over combustible material clearances.

The air handler must be installed so that free access is allowed to the coil/filter compartment and blower/control compartment.

NOTE: During cooling operation, excessive sweating may occur if the air handler is installed in a warm and humid space.

NOTE: If installed in an unconditioned space, sealant should be applied around the electrical wires, refrigerant tubing, and condensate lines where they enter the cabinet.

NOTE: Electrical wires should be sealed on the inside where they exit the conduit opening. Sealant is required to prevent air leakage into, and condensate from forming inside of, the air handler, the control box, and on the electrical controls.

NOTE: This unit is approved for installation clearance to combustible material as stated on the unit rating plate. Accessibility and service clearances must take precedence over combustible material clearances.

NOTE: The air handler must be installed so that free access is allowed to the coil/filter compartment and blower/control compartment.

Installation Clearances

Non-Ducted Return Closet Installation

The air handler can be installed in a closet with a false bottom to form a return air plenum. It may also be installed with a return air plenum under the air handler.

Louvers or return air grilles are field-supplied. Local codes may limit application of systems without a ducted return to single-story buildings.

When a MAHM*ETAunit is installed in a closet with a louvered return opening, the minimum open area for the louvers will be:

• 320 square inches for -024 models;
• 360 square inches for -030 and -036 models;
• 450 square inches for -042 thru -060 models

If the free area is not known, assume a 25% free area for wood or a 75% free area for metal louvers or grilles. Using the louver dimensions and the 25% or 75% assumption, determine if the open area meets the minimum open area listed above.

If a return air plenum is used, the return air grille should be immediately in front of the opening in the plenum to allow for the free flow of return air. When not installed in front of the opening, there must be adequate clearance around the air handler to allow for the free flow of return air.

Installation

Each unit consists of a blower assembly, refrigerant coil, and controls in an insulated galvanized steel factory-finished enclosure. Knockouts are provided for electrical wiring entrance.

For ease in installation, it is best to make any necessary coil configuration changes before setting air handler in place.

Refrigerant Metering Device

MAHM*ETAunits are equipped with a factory-installed expansion valve with internal check valve for cooling or heat pump application.

MRCOOL MAHM048ETA - Refrigerant Metering Device - 1

text_image UP-FLOW / DOWN-FLOW DRAIN PAN HORIZONTAL DRAIN PAN (MUST BE REMOVED)

Figure 1. Upflow Configuration

Upflow Application

  1. The air handler must be supported on the bottom only and set on solid floor or field-supplied support frame. Securely attach the air handler to the floor or support frame.
  2. If installing a unit in an upflow application, remove the horizontal drain pan.
    NOTE: The horizontal drain pan is not required in upflow air discharge installations; its removal provides the best efficiency and air flow.
  3. Place the unit in the desired location and slope unit. Connect return and supply air plenums as required using sheet metal screws.
  4. Install units that have no return air plenum on a stand that is at least 14" from the floor. This will allow proper air return.

Horizontal Applications

MRCOOL MAHM048ETA - Horizontal Applications - 1

IMPORTANT

When removing the coil, there is a possibility of danger of equipment damage and personal injury. Be careful when removing the coil assembly from a unit installed in right- or left-hand applications. The coil may tip into the drain pan once it is clear of the cabinet. Support the coil when removing it..

NOTE: When the unit is installed in horizontal applications, a secondary drain pan is recommended. Refer to local codes.

NOTE: This unit may be installed in left-hand or right-hand air discharge horizontal applications. Adequate support must be provided to ensure cabinet integrity. Ensure that there is adequate room to remove service and access panels if installing in the horizontal position.

MRCOOL MAHM048ETA - IMPORTANT - 1

text_image AIR FLOW Drains RIGHT-HAND DRAINS PLUGS

Figure 2. Right-Hand Discharge Configuration

Right-Hand Discharge

  1. Determine which plugs are required for drain line connections.
  2. With access door removed, remove drain line plugs to install drain lines.

  3. Set unit so that it is sloped toward the upflow drain pan end of the unit and level from front to back of unit (see Figure 7).

  4. The horizontal configuration is shown in Figure 2.
  5. If the unit is suspended, the entire length of the cabinet must be supported. If you use a chain or strap, use a piece of angle iron or sheet metal attached to the unit (either above or below) to support the length of the cabinet. Use securing screws no longer than 1/2 inch to avoid damaging the coil or filter. See Figure 3. Use sheet metal screws to connect the return and supply air plenums as required.

MRCOOL MAHM048ETA - Right-Hand Discharge - 1

text_image ANGLE IRON OR SHEET METAL MAXIMUM 1/2" LONG SCREW ELECTRICAL INLET CLEAR- ANCE 4 IN. (102 MM) AIR FLOW WEIV FRONT WEIVDNE

Figure 3. Suspending Horizontal Unit

Left-Hand Air Discharge

For horizontal left-hand air discharge, the following field modifications are required.

  1. Remove access panels and the corrugated padding between the blower and coil assembly. Discard the corrugated padding.
  2. Pull the coil assembly from unit. Pull off the horizontal drain pan.
  3. Remove the drain plugs from back drain holes on horizontal drain pan and reinstall them on front holes.

MRCOOL MAHM048ETA - Left-Hand Air Discharge - 1

IMPORTANT

After removal of drain pan plug(s), check drain hole(s) to verify that drain opening is fully open and free of any debris. Also check to make sure that no debris has fallen into the drain pan during installation that may plug up the drain opening.

  1. Rotate drain pan 180° front-to-back and install it on the opposite side of the coil.
  2. Remove screws from top cap.
  3. Remove plastic plug from left hole on coil front end seal and reinstall plug in back hole.

MRCOOL MAHM048ETA - IMPORTANT - 1

text_image TOP CAP ROTATED TO CORRECT POSITION CABINET SUPPORT TOP CAP SCREWS 90° BEND DRAIN PAN REINSTALLED HERE DRAIN PAN SHIPPING LOCATION REINSTALLED HERE DRAIN PLUGS removed FROM HERE COIL SHOWN IN UPLOAD POSITION FOR EASY CONVERSION TOP CAP 90° BEND ALIGN HOLES WITH HOLES IN COIL END PLATE. STARTING WITH THE ROUND HOLES ON THIS END. BACK COIL END SEAL

Figure 4. Field Modification for Left-Hand Discharge

  1. Rotate top cap 180° front-to-back and align with unused screw holes. Holes must align with front and back coil end plates. The top cap has a 45° bend on one side and a 90° bend on the other. The 90° bend must be on the same side as the horizontal drain pan as illustrated in Figure 4.

MRCOOL MAHM048ETA - IMPORTANT - 2

text_image FRONT EDGE OF HORIZONTAL DRAIN PAN

Figure 5. Left-Hand Discharge Configuration

NOTE: Be very careful when reinstalling the screws into the coil end plate engaging holes. Misaligned screws may damage the coil.

  1. From the upflow position, flip cabinet 90° to the left and set into place. Replace blower assembly. Secure coil in place by bending down the tab on the cabinet support rail as illustrated.

NOTE: Seal around the exiting drain pipe, liquid and suction lines to prevent infiltration of humid air.

  1. Flip access door and replace it on the unit.

  2. Set unit so that it is sloped 1/4" toward the drain pan end of the unit. Connect return and supply air plenums as required using sheet metal screws.

  3. If suspending the unit, it must be supported along the entire length of the cabinet. If using chain or strap, use a piece of angle iron or sheet metal attached to the unit (either above or below) so that the full length of the cabinet is supported. Use securing screws no longer than 1/2" to avoid damage to coil or filter, as illustrated in Figure 3. Connect return and supply air plenums as required using sheet metal screws.

Downflow Application

NOTE: If downflow application is required, separately order kit number 83M57 and install per kit's instructions. Also use metal or class I supply and return air plenums. Use the installation instruction provided with the downflow kit.

IMPORTANT

If electric heat section with circuit breakers (ECBA25) is installed in a MAHM*ETAunit in a downflow application, the circuit breakers must be rotated 180° to the UP position. See ECBA25 installation instructions for more details.

Condensate Drain

IMPORTANT

On units of this type, where the blower "draws" rather than "blows" air through the coil, traps must be installed in the condensate drain lines (primary and auxiliary, if used). Traps prevent the blower from drawing air through the drain lines into the air supply.

IMPORTANT

A field-fabricated secondary drain pan, with a drain pipe to the outside of the building, is required in all installations over a finished living space or in any area that may be damaged by overflow from the main drain pan. In some localities, local codes may require a secondary drain pan for any horizontal installation.

MRCOOL MAHM048ETA - IMPORTANT - 1

flowchart
graph TD
    A["ABOVE FINISHED SPACE?"] --> B{NO}
    B --> C["AIR HANDLER DRAIN PAN"]
    C --> D["MAIN DRAIN"]
    D --> E["CACT OUT PRESS IN (DO NOT GLUE)"]
    E --> F["1" X 3/4" X 3/4" REDUCING TEE WITH PLUG"]
    F --> G["VENT MUST EXTEND ABOVE HEIGHT OF COIL DRAIN PAN BY TWO INCHES (51MM)"]
    G --> H["2" (51MM)"]
    H --> I["TRAP DEPTH"]
    I --> J["TO APPROVED DRAIN"]
    K["SECONDARY DRAIN PAN"] --> L["NOTE — WHEN A AIR HANDLER IS LOCATED ABOVE A FINISHED SPACE THE SECONDARY DRAIN PAN MUST HAVE A LARGER FOOTPRINT THAN THE AIR HANDLER."]
    L --> M["WHEN A COIL IS LOCATED ABOVE A FINISHED SPACE, A 3/4" (19.1MM) SECONDARY DRAIN LINE MUST BE:"]
    M --> N["• CONNECTED TO SECONDARY DRAIN PAN OR • CONNECTED TO THE OVERFLOW DRAIN OUTLET OF THE AIR HANDLER DRAIN PAN. TRAPS MUST BE DEEP ENOUGH TO OFFSET MAXIMUM STATIC DIFFERENCES — GENERALLY, TWO INCHES (51MM)."]
    N --> O["FOR NEGATIVE PRESSURE COILS (BLOWER AFTER COIL). TRAPS ARE REQUIRED ON ALL DRAIN LINES CONNECTED TO COIL."]
    O --> P["DRAIN LINE SHOULD SLOPE A MINIMUM OF ONE INCH PER 10 FEET (25MM PER 3 METERS)."]

Figure 6. Typical Main and Overflow Drain

Sloping The Unit

Make sure the unit is sloped (similar to the slope shown in Figure 7) so that the drain pan will empty completely without water standing in the pan.

MRCOOL MAHM048ETA - Sloping The Unit - 1

text_image THIS CORNER SHOULD BE 5/8" (+/- 1/8") HIGHER THAN DRAIN CORNER LEVEL PLANE DRAIN CORNER LEVEL PLANE

Figure 7. Sloping the Unit for Proper Drainage

Install Condensate Drain

The air handler is provided with 3/4" NPT condensate drain connections.

507788-01C mrcool.com Page 7 of 20

IMPORTANT

On some pans, the primary and secondary drain holes have knockouts.

Confirm primary and secondary drains are open.

  1. MAHM*ETA units are equipped with a drain pan, which includes green (main drain) and red (secondary drain) plugs. Unscrew the plugs to remove them before inserting condensate drain fittings.

MRCOOL MAHM048ETA - IMPORTANT - 1

text_image UNSCREW PLUGS AND CONNECT PROPERLY SIZED FIELD-PROVIDED FITTINGS AND DRAIN LINES. DRAIN PAN GREEN MAIN DRAIN PLUG RED SECONDARY DRAIN PLUG

Figure 8. Drain Line Connections

  1. Install properly sized, field-provided connection fittings and connect primary drain line to the main drain pan connection.

NOTE: When installing drain line connection fittings to the drain pan, hand tighten the fitting and use a thread sealant. Over-tightening the fittings can split connections on the drain pan.

  1. If the secondary drain line is to be used, remove the plug or the knockout and route the drain line so that water draining from the outlet will be easily noticed by the homeowner. Refer to local codes for drain trap requirements on the secondary drain line.
  2. Check again to ensure drain ports and drain pan are free of all debris.
  3. Plug and check any unused drain pan openings for tightness. Torque plugs to 36 in. lb. to prevent water leaks or seepage from the drain pan.
  4. Install a 2" trap in the main (primary) drain lines as close to the unit as practical (see Figure 6). Make sure the top of the trap is below the connection to the drain pan to allow complete drainage of the pan.

NOTE: Horizontal runs must have an anti-siphon air vent (standpipe) installed ahead of the horizontal run. See Figure 6. An extremely long horizontal run may require an oversized drain line to eliminate air traps.

NOTE: Do not operate air handler without a trap in the main (primary) drain. The condensate drain is on the negative pressure side of the blower; therefore, air being pulled through the condensate line will not allow positive drainage without a proper trap.

  1. Route the drain line to the outside or to an appropriate drain. Drain lines must be installed so they do not block service access to the front of the air handler. A 24" clearance is required for filter, coil, or blower removal and service access.

NOTE: Check local codes before connecting the drain line to an existing drainage system. Insulate the drain lines where sweating could cause water damage.

Test Condensate Drain

Test the drain pan and drain line after installation:

  1. Pour several quarts of water into drain pan. Use enough water to fill both the drain trap and the line.
  2. Check the installed drain pan. Drain pan must be draining completely. Drain line fittings must not be leaking. Water must be draining from the end of the primary drain line.

  3. Correct any leaks found.

Duct System and Filters

Duct System

The air handler is provided with flanges for the connection of the supply plenum.

Supply and return duct system must be adequately sized to meet the system's air requirements and static pressure capabilities. The duct system should be insulated with a minimum of 1" thick insulation with a vapor barrier in conditioned areas or 2" minimum in unconditioned areas.

Supply plenum should be the same size as the flanged opening provided around the blower outlet and should extend at least 3 ft. from the air handler before turning or branching off plenum into duct runs. The plenum forms an extension of the blower housing and minimizes air expansion losses from the blower.

Filters

A filter is provided. Table 1 lists the filter size for each unit.

Model Filter Size - in.
-024, -030 15" x 20" x 1"
-036, -042, -048, -060 18" x 20" x 1"

Table 1. Unit Air Filter Size Chart

IMPORTANT

If a high efficiency filter is being installed as part of this system to ensure better indoor air quality, the filter must be properly sized. High efficiency filters have a higher static pressure drop than standard efficiency glass/foam filters. If the pressure drop is too great, system capacity and performance may be reduced. The pressure drop may also cause the limit to trip more frequently during the winter and the indoor coil to freeze in the summer, resulting in an increase in the number of service calls. Before using any filter with this system, check the specifications provided by the filter manufacturer against the data given in the appropriate Product Specifications. Additional information is provided in Service and Application Note ACC002 (August 2000).

Installing Duct System

Connect supply air duct to the flange on top of the air handler. If an isolation connector is used, it must be nonflammable.

Field-Fabricated Return Air Duct Flange For Horizontal Applications

A return air duct system is recommended, but not factory-provided. If the unit is installed in a confined space or closet, run a full-size return connection to a location outside the closet.

Cabinet and Duct Flange
MRCOOL MAHM048ETA - Field-Fabricated Return Air Duct Flange For Horizontal Applications - 1

text_image CABINET DOOR FLANGE 1-1/2 (38) DUCT FLANGE 3/4 (19) 3/4 (19) BOTTOM OF CABINET DUCT ADAPTER "A" 1-1/2(38) BRAKE DOWN 90 DEGREES 1/2 (13) 1/4 (6) DIA. 2-HOLES 3/4 (19) 1-1/2 (38)
UNIT SIZE"A"
-024, -03018-3/8"
-036, -042,-048, -06021-1/2"

Figure 9. Cabinet and Duct Flange

Brazing Refrigerant Lines

Refrigerant lines must be connected by a qualified technician in accordance with established procedures.

IMPORTANT

Refrigerant lines must be clean, dry, refrigerant-grade copper lines. Air handler coils should be installed only with specified line sizes for approved system combinations.

Handle the refrigerant lines gently during the installation process. Sharp bends or kinks in the lines will cause a restriction.

Do not remove the caps from the lines or system connection points until connections are ready to be completed.

WARNING

Polyol ester (POE) oils used with HFC-410A refrigerant absorb moisture very quickly. It is very important that the refrigerant system be kept closed as much as possible. DO NOT remove line set caps or service valve stub caps until you are ready to make connections.

WARNING

MRCOOL MAHM048ETA - WARNING - 1

When using a high pressure gas such as nitrogen to pressurize a refrigeration or air conditioning system, use a regulator that can control the pressure down to 1 or 2 psig (6.9 to 13.8 kPa).

MRCOOL MAHM048ETA - WARNING - 2

WARNING

Danger of fire. Bleeding the refrigerant charge from only the high side may result in pressurization of the low side shell and suction tubing. Application of a brazing torch to a pressurized system may result in ignition of the refrigerant and oil mixture. Check the high and low pressures before applying heat.

CAUTION

Brazing alloys and flux contain materials which are hazardous to your health.

Avoid breathing vapors or fumes from brazing operations. Perform operations only in well-ventilated areas.

Wear gloves and protective goggles or face shield to protect against burns.

Wash hands with soap and water after handling brazing alloys and flux.

IMPORTANT

To prevent the build-up of high levels of nitrogen when purging, it must be done in a well-ventilated area. Purge low-pressure nitrogen (1 to 2 psig) through the refrigerant piping during brazing. This will help to prevent oxidation and the introduction of moisture into the system.

NOTE: Recommended line length is 50' or less. If more than 50' line set is required, contact MRCOOL.

  1. Route the suction and liquid lines from the fittings on the indoor coil to the fittings on the outdoor unit. Run the lines in a direct path, avoiding unnecessary turns and bends.
  2. Make sure that the suction line is insulated over the entire exposed length and that neither suction nor liquid lines are in direct contact with floors, walls, duct system, floor joists, or other piping.

PLEASE READ IMPORTANT ISSUES CONCERNING BRAZING OPERATIONS IN THE BRAZING REFRIGERANT LINES SECTION BEFORE PROCEEDING.

NOTE - REFER TO OUTDOOR UNIT INSTALLATION INSTRUCTIONS FOR REFRIGERANT PIPING SIZE REQUIREMENTS.

NOTE - Use silver alloy brazing rods with five or six percent minimum silver alloy for copper-to-copper brazing, 45 percent alloy for copper-to-brass and copper-to-steel brazing.

A REMOVE ACCESS PANEL
B REMOVE RUBBER PLUG FROM BOTH LIQUID AND SUCTION LINES NOTE - MAHM'ETA SERIES UNITS USE NITROGEN OR DRY AIR AS A HOLDING CHARGE. IF THERE IS NO PRESSURE WHEN THE RUBBER PLUGS ARE REMOVED, CHECK THE COIL FOR LEAKS BEFORE INSTALLING.
C EITHER REMOVE OR PUSH PIPE WRAPPING BACK THROUGH HOLE IN PIPING PLATE BEFORE LINE SET CONNECTION AND BRAZING.
D CONNECT PIPES NOTE - REFRIGERANT LINE SETS SHOULD BE ROUTED TO ALLOW FILTER ACCESSIBILITY.

MRCOOL MAHM048ETA - PLEASE READ IMPORTANT ISSUES CONCERNING BRAZING OPERATIONS IN THE BRAZING REFRIGERANT LINES SECTION BEFORE PROCEEDING. - 1

natural_image Simple line drawing of a mechanical assembly with cylindrical components and a rectangular block, enclosed in an oval (no text or symbols)

F PLACE A WET RAG AGAINST PIPING PLATE AND AROUND THE SUCTION LINE CONNECTION.
G BRAZE CONNECTION. ALLOW PIPE TO COOL BEFORE REMOVING WET RAG FROM CTXV SENSING BULB AND PIPING PANEL AREA.
H REPEAT PREVIOUS PROCEDURE FOR LIQUID LINE.

MRCOOL MAHM048ETA - PLEASE READ IMPORTANT ISSUES CONCERNING BRAZING OPERATIONS IN THE BRAZING REFRIGERANT LINES SECTION BEFORE PROCEEDING. - 2

natural_image Cross-sectional diagram of a mechanical device showing internal components and wiring (no text or symbols)

PIPING PLATE
E CONNECT GAUGES AND START NITROGEN FLOW

FLOW REGULATED NITROGEN (AT 1 TO 2 PSIG) THROUGH THE REFRIGERATION GAUGE SET INTO THE VALVE STEM PORT CONNECTION ON THE OUTDOOR UNIT LIQUID LINE SERVICE VALVE AND OUT OF THE VALVE STEM PORT CONNECTION ON THE SUCTION SERVICE VALVE.

MRCOOL MAHM048ETA - PLEASE READ IMPORTANT ISSUES CONCERNING BRAZING OPERATIONS IN THE BRAZING REFRIGERANT LINES SECTION BEFORE PROCEEDING. - 3

natural_image Line drawing of a person climbing a rope between two walls, enclosed in an oval frame (no text or symbols)

REFER TO INSTRUCTIONS PROVIDED WITH OUTDOOR UNIT FOR LEAK TESTING, EVACUATING AND CHARGING PROCEDURES

Figure 10. Brazing Connections

  1. To avoid damaging the rubber grommets in the cabinet while brazing, slide the rubber grommets over the refrigerant lines until they are away from the heat source.

NOTE: Place wet rags against piping plate and around suction line connections.

  1. Connect the suction and liquid lines to the evaporator coil. Take care to protect the cabinet and internal components as detailed in Figure 10.

  2. Braze using an alloy of silver or copper and phosphorus with a melting point above 1,100°F (593°C).

NOTE: Do not use soft solder.

  1. Allow refrigerant pipes to cool to room temperature.

NOTE: Make sure to route copper refrigerant tubing away from sharp edges and make sure that it does not touch other metal surfaces. This prevents damage caused by vibration or metal-on-metal contact.

  1. Reinstall the rubber grommets into the refrigerant piping panel.

NOTE: Make sure expansion valve capillary tube is not touching metal edges or copper tubing.

  1. Make sure outdoor unit has been placed according to the Installation Instructions and is connected to the refrigerant lines

Sealing the Unit

Seal the unit so that warm air is not allowed into the cabinet. Warm air introduces moisture, which results in water blow-off problems. This is especially important when the unit is installed in an unconditioned area.

If installed in an unconditioned space, sealant should be applied around the electrical wires, refrigerant tubing, and condensate lines where they enter the cabinet.

MRCOOL MAHM048ETA - Sealing the Unit - 1

WARNING

There must be an airtight seal between the bottom of the air handler and the return air plenum. Use fiberglass sealing strips, caulking, or equivalent sealing method between the plenum and the air handler cabinet to ensure a tight seal. Return air must not be drawn from a room where this air handler or any gas-fueled appliance (i.e., water heater), or carbon monoxide-producing device (i.e., wood fireplace) is installed.

MRCOOL MAHM048ETA - WARNING - 1

IMPORTANT

Use duct tape and/ or Permagum to seal closed any space around the holes where the drain lines exit the cabinet. Warm air must not be allowed to enter through any gaps or holes in the cabinet.

Electrical Connections

WARNING

MRCOOL MAHM048ETA - WARNING - 1

Electric shock hazard! - Disconnect all power supplies before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electric shock.

WARNING

Run 24V Class II wiring only through specified low voltage opening. Run line voltage wiring only through specified high voltage opening. Do not combine voltage in one opening.

WARNING

Electric Shock Hazard.

Can cause injury or death.

MRCOOL MAHM048ETA - WARNING - 1

Foil-faced insulation has conductive characteristics similar to metal. Be sure there are no electrical connections within 1/2" of the insulation. If the foil-faced insulation comes in contact with electrical voltage, the foil could provide a path for current to pass through to the outer metal cabinet. While the current produced may not be enough to trip existing electrical safety devices (e.g., fuses or circuit breakers), the current can be enough to cause an electrical shock hazard that could cause personal injury or death.

WARNING

Electric Shock Hazard. Can cause injury or death. Unit must be properly grounded in accordance with national and local codes.

MRCOOL MAHM048ETA - WARNING - 1

Line voltage is present at all components when unit is not in operation on units with single-pole contactors. Disconnect all remote electric power supplies before opening access panel. Unit may have multiple power supplies.

- Wiring must conform to the current National Electric Code ANSI/NFPA No. 70, or Canadian Electric Code Part I, CSA Standard C22.1, and local building codes. Refer to following wiring diagrams. See unit nameplate for minimum circuit ampacity and maximum over-current protection size.

  • Electrical wiring, disconnect means and over-current protection are to be supplied by the installer. Refer to the air handler rating plate for maximum over-current protection, minimum circuit ampacity, as well as operating voltage. Select the proper supply circuit conductors in accordance with tables 310-16 and 310-17 in the National Electric Code, ANSI/NFPA No. 70 or tables 1 through 4 in the Canadian Electric Code, Part I, CSA Standard C22.1.
    • The power supply must be sized and protected according to the specifications supplied on the product.
  • This air handler is factory-configured for 240 volt, single phase, 60 cycles. For 208-volt applications, see "208 Volt Conversion" later in this section.
  • Separate openings have been provided for 24V low voltage and line voltage. Refer to the dimension illustration of specific location.
  • This unit is provided with holes for conduit. Use provided caps to seal holes not used.
  • Typical unit wiring (as well as wiring of optional field-installed electric heat) is given in Figure 14. Refer to the instructions provided with the electric heat section for proper installation.

MRCOOL MAHM048ETA - WARNING - 2

WARNING

USE COPPER CONDUCTORS ONLY

  1. Disconnect all power supplies.
  2. Remove the air handler access panel.
  3. Route the field supply wires to the air handler electrical connection box.
  4. Use UL-listed wire nuts to connect the field supply conductors to the unit black and yellow leads, and the ground wire to ground terminal marked GND.
  5. Replace the air handler access panel.

MRCOOL MAHM048ETA - USE COPPER CONDUCTORS ONLY - 1

text_image TOP SIDE

Figure 11. Electrical Connections (Upflow Configuration)

NOTE: To avoid the possibility of moisture damage to the control in some right-hand discharge configurations, the control panel can be relocated to the end panel as shown in Figure 12.

MRCOOL MAHM048ETA - USE COPPER CONDUCTORS ONLY - 2

text_image TOP SIDE

Figure 12. Control Panel Relocated to End Panel (Left-Hand Horizontal Configuration)

208 Volt Conversion

  1. Disconnect all power supplies.
  2. Remove the air handler access panel.
  3. Using the wiring diagram located on the unit access panel as a reference, move the 2 connected black transformer leads from the 240 volt terminal on the transformer to the 208 volt terminal on the transformer.

208 / 240 VOLT TRANSFORMER
MRCOOL MAHM048ETA - Volt Conversion - 1

text_image PRIMARY 240 Volts 208 Volts SECONDARY

Figure 13. Converting Unit from 240VAC to 208VAC

MRCOOL MAHM048ETA - Volt Conversion - 2

text_image IEU USA 537981-01 Form No. 0518 Designations STANDARD ELECTRIC HEAT CONSTANT TOROUE LABEL WIRING DIAGRAM

MRCOOL MAHM048ETA - Volt Conversion - 3

text_image PART NO. 537981-01 WIRING DIAGRAM - ELECTRIC HEAT 20KW 12.5KW & 15KW 7.5KW & 10KW HEATERS USED 5 KW = HTR1 7.5 & 10 KW = HTR1 & HTR2 15 KW = HTR1, HTR2 & HTR3 20 KW = HTR1, HTR2, HTR3 & HTR4 TB = TERMINAL BLOCK CB = CIRCUIT BREAKER SEQ = SEQUENCER GND = GROUND LUG PRI LS= LIMIT SWITCH SEC L= LIMIT SWITCH HTR = HEATER ELEMENT POWER (FACTORY WIRED) POWER (FIELD WIRED) CONTROL (FACTORY WIRED) CONTROL (FIELD WIRED) CONTROL CIRCUIT WIRING TO BE 24 VOLT, N.E.C. CLASS 2 THREE POLE SEQUENCER PLUG PIN TIMING - SEC ON OFF LOCATION 1-20 40-110 20-60 1-30 20-60 1-30 TWO POLE SEQUENCER TIMING - SEC ON OFF 30-90 1-30 30-90 1-30 TD = TIME DELAY (OPT.) ** TR = TRANSFORMER BR = BLOWER RELAY MTR = BLOWER MOTOR CAP = MOTOR CAPACITOR GND = GROUND CONNECTION WIRING DIAGRAM: NO HEAT MTR 14 BLK L1 COM 20BV 240V 14 YEL 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLK 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLB 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBL 14 BLBRLN 18 YEL 18 YEL 18 YEL 18 YEL 18 YEL 18 YEL 18 YEL 18 YEL 18 YEL TERMINAL STRIP W2 W2 W1 G O R DS C Y1 Y2 TO THERMOSTAT BY OTHERS

Figure 14. Typical Wiring Diagram MAHM*ETA Air Handler with Electric Heat – (Constant Torque Motor)

MRCOOL MAHM048ETA - Volt Conversion - 4
Figure 15. Low Voltage Connections (Constant Torque Motor)

Blower Performance Data

Speed TapApplicationExternal Static Pressure (in. w.c.)
0.1 0.20.3 0.4 0.5
-241 FanOnly 590 575 530 480 430
2Matched with 1.5 ton condensing unit750 650610 550 480
3Nominal 2 ton match without electric heat950 825785 740 690
4Nominal 2 ton match with electric heat1040 1020985 940 920
5 High static application 1160 1140 1120 1080 1050
-301 FanOnly 700 665 625 565 490
2Matched with 2 ton condensing unit860 810770 715 665
3Nominal 2.5 ton match without electric heat1040 1010980 940 890
4Nominal 2.5 ton match with electric heat1140 11001045 1015980
5 High static application 1390 1375 1340 1285 1245
-361 FanOnly 850 800 750 665 600
2Matched with 2.5 ton condensing unit1080 950910 850 775
3Nominal 3 ton match without electric heat1270 12301170 11201060
4Nominal 3 ton match with electric heat1440 14001330 12801240
5 High static application 1540 1475 1430 1380 1300
-421 FanOnly 990 915 860 810 725
2Matched with 3 ton condensing unit1190 11501100 10601020
3Nominal 3.5 ton match without electric heat1390 13501315 12801230
4Nominal 3.5 ton match with electric heat1665 16251585 15501510
5 High static application 1750 1710 1675 1640 1600
-481 FanOnly 1255 1210 1155 1115 1050
2Matched with 3.5 ton condensing unit1485 14501410 13651330
3Nominal 4 ton match without electric heat1720 16751630 15951550
4Nominal 4 ton match with electric heat1720 16751630 15951550
5 High static application 1840 1795 1755 1720 1680
-601 FanOnly 1100 1050 1000 925 830
2Matched with 4 ton condensing unit1625 15951565 15201490
3Nominal 5 ton match without electric heat1815 17801760 17301685
4Nominal 5 ton match with electric heat1900 18701835 18101765
5 High static application 1980 1955 1920 1890 1860

Table 2. MAHM*ETA Constant Torque Air Handler Wet Air Flow Data

Air Flow - Cooling Blower Speed

The cooling blower speed is factory configured to provide correct air flow for an outdoor unit that matches the cooling capacity rating of the air handler (Tap 3).

If the outdoor unit is smaller than the maximum cooling capacity rating for the air handler, the cooling blower speed may need to be changed. Refer to blower performance chart (Table 2).

WARNING

ELECTRIC SHOCK HAZARD!

MRCOOL MAHM048ETA - ELECTRIC SHOCK HAZARD! - 1

Disconnect all power supplies before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

Adjusting Blower Speed

Motor Speed Taps

NOTE - Motor is programmed for a 45-second OFF delay on all speed taps except TAP #1 (continuous fan speed).

These settings are for nominal tonnage match-ups with the MAHM*ETAunits. When matched with other sizes, it is recommended that the CFM be adjusted to approximately 400 CFM per ton.

TapOperation Remarks
1 CContinuous fan Continuous fan speed is energized (24 volt input to G).
2Lower tonnage speed nominal capacity (e.g. if 3-ton air handler is used with 2.5-ton outdoor unit).
3A/C or heat pump - no electric heatAir flow set at 400 SCFM per ton at minimum static allowed.
4*A/C or Heat pump with electric heatAir flow set at 400 SCFM per ton at .5 static. Energized when electric heat element has a call for heat.
5 Hgh static applicationsAir flow set at 400 cfm per ton at .8 static. (Connect white wire from blower relay to Tap 5 instead of Tap 4)
* Tap 4 is minimum setting for electric heat

Table 3.

Operation Inspection

NOTE: Refer to outdoor unit installation instructions for system start-up instructions and refrigerant charging instructions.

Pre-Start-Up Checks

  • Is the air handler properly and securely installed?
  • If horizontally configured, is the unit sloped up to 5/8 inch toward drain lines?
  • Will the unit be accessible for servicing?
  • Has an auxiliary pan been provided under the unit with separate drain for units installed above a finished ceiling or in any installation where condensate overflow could cause damage?
    • Have ALL unused drain pan ports been properly plugged?
  • Has the condensate line been properly sized, run, trapped, pitched, and tested?
  • Is the duct system correctly sized, run, sealed, and insulated?
    • Have all cabinet openings and wiring been sealed?
    • Is the indoor coil factory-installed TXV properly sized for the outdoor unit being used?
    • Have all unused parts and packaging been disposed of?
    • Is the filter clean, in place, and of adequate size?
  • Is the wiring neat, correct, and in accordance with the wiring diagram?
  • Is the unit properly grounded and protected (fused)?
  • Is the thermostat correctly wired and in a good location?
  • Are all access panels in place and secure?

Check Blower Operation

  1. Set thermostat to FAN ON.
  2. The indoor blower should turn on.

Check Unit Operation

  1. Set thermostat to force a call for cooling (approximately 5^ F lower than the indoor ambient temperature).
  2. The outdoor unit should turn on immediately.
  3. Check the air flow from a register to confirm that the system is moving cooled air.
  4. Set the thermostat 5°F higher than the indoor temperature. The indoor blower and outdoor unit should cycle off. Air handler should cycle off 45 seconds after the outdoor unit shuts off.

Check Electric Heat (If Used)

  1. Set thermostat to call for auxiliary heat (approximately 5^ F above ambient temperature). The indoor blower and auxiliary heat should come on together. Allow a minimum of 3 minutes for all sequencers to cycle on.

  2. Set the thermostat so that it does not call for heat. Allow up to 5 minutes for all sequencers to cycle off.

Operation

Cooling (Cooling Only or Heat Pump)

When the thermostat calls for cooling, 24 volts is put on the blower time-delay relay coil and then the indoor blower relay energizes. The normally open contacts close, causing the indoor blower motor to operate. The circuit between R and Y is completed, closing the circuit to the contactor in the outdoor unit, starting the compressor and outdoor fan motor.

On heat pumps, circuit R and O energizes the reversing valve, switching the valve to the cooling position. (The reversing valve remains energized as long as the thermostat selector switch is in the COOL position.)

At the completion of the cooling demand, the indoor blower and outdoor unit should cycle off. Air handler should cycle off 45 seconds after the outdoor unit shuts off.

Heating (Electric Heat Only)

When the thermostat calls for heat, the circuit between R and W is completed, and the heat sequencer is energized. A time delay follows before the heating elements and the indoor blower motor come on. Units with a second heat sequencer can be connected with the first sequencer to W on the thermostat sub-base, or they may also be connected to a second stage on the sub-base.

Heating (Heat Pump)

When the thermostat calls for heating, 24 volts is applied to the blower time-delay relay coil. The normally open contacts close, causing the indoor blower motor to operate. The circuit between R and Y is completed, closing the circuit to the contactor in the outdoor unit, starting the compressor and outdoor fan motor.

If the room temperature continues to decrease, the circuit between R and W1 is completed by the second-stage heat room thermostat. Circuit R-W1 energizes a heat sequencer. The completed circuit will energize supplemental electric heat (if applicable). Units with a second heat sequencer can be connected with the first sequencer to W1 on the thermostat. They may also be connected to a second heating stage W2 on the thermostat sub-base.

Emergency Heat (Heating Heat Pump)

If the selector switch on the thermostat is set to the emergency heat position, the heat pump will be locked out of the heating circuit, and all heating will be electric heat (if applicable). A jumper should be placed between W2 and E on the thermostat sub-base so that the electric heat control will transfer to the first-stage heat on the thermostat. This will allow the indoor blower to cycle on and off with the electric heat when the fan switch is in the AUTO position.

Maintenance

IMPORTANT

Do not operate system without a filter. A filter is required to protect the coil, blower, and internal parts from excessive dirt and dust. The MAHM*ETA units are shipped with filters. Remove this filter if the return air register already has a filter.

  • Inspect air filters at least once a month and replace or clean as required. Dirty filters are the most common cause of inadequate heating or cooling performance.
  • Replace disposable filters. Cleanable filters can be cleaned by soaking in mild detergent and rinsing with cold water.
    • Install new/clean filters with the arrows on the side pointing in the direction of air flow. Do not replace a cleanable (high velocity) filter with a disposable (low velocity) filter unless return air system is properly sized for it.
  • If water should start coming from the secondary drain line, a problem exists which should be investigated and corrected. Contact a qualified service technician.

Professional Maintenance

NOTICE

Failure to follow instructions will cause damage to the unit.

This unit is equipped with an aluminum coil. Aluminum coils may be damaged by exposure to solutions with a pH below 5 or above 9. The aluminum coil should be cleaned using potable water at a moderate pressure (less than 50psi). If the coil cannot be cleaned using water alone, it is recommended to use a coil cleaner with a pH in the range of 5 to 9. The coil must be rinsed thoroughly after cleaning.

In coastal areas, the coil should be cleaned with potable water several times per year to avoid corrosive buildup (salt).

Cabinet Insulation

MRCOOL MAHM048ETA - Cabinet Insulation - 1

IMPORTANT

DAMAGED INSULATION MUST BE REPAIRED OR REPLACED before the unit is put back into operation. Insulation loses its insulating value when wet, damaged, separated or torn.

Matte- or foil-faced insulation is installed in indoor equipment to provide a barrier between outside air conditions (surrounding ambient temperature and humidity) and the varying conditions inside the unit. If the insulation barrier is damaged (wet, ripped, torn or separated from the cabinet walls), the surrounding ambient air will affect the inside surface temperature of the cabinet.

The temperature/humidity difference between the inside and outside of the cabinet can cause condensation on the inside or outside of the cabinet which leads to sheet metal corrosion and, subsequently, component failure.

Repairing Damaged Insulation

Areas of condensation on the cabinet surface are an indication that the insulation is in need of repair.

If the insulation in need of repair is otherwise in good condition, the insulation should be cut in an X pattern, peeled open, glued with an appropriate all-purpose glue and placed back against the cabinet surface, being careful to not overly compress the insulation so the insulation can retain its original thickness. If such repair is not possible, replace the insulation. If using foil-faced insulation, any cut, tear, or separations in the insulation surface must be taped with a similar foil-faced tape.

MRCOOL MAHM048ETA - Repairing Damaged Insulation - 1

text_image GLUE - Make sure there is full coverage of glue on the metal or insulation so there are no areas where air pockets may form which can lead to sweating. 1. CUT INSULATION IN X PATTERN 2. APPLY GLUE 3. PRESS GLUED TABS AGAINST CABINET

Figure 16. Recommended Blower Speed Taps

Use of Air Handler During Construction

It is not recommended to use this air handler unit during any phase of construction. Very low return air temperatures, harmful vapors and operation of the unit with clogged or misplaced filters will damage the unit.

Air handler units may be used for heating (heat pumps) or cooling of buildings under construction, if the following conditions are met:

  • A room thermostat must control the air handler. The use of fixed jumpers is not allowed.
    • Air filter must be installed in the system and must be maintained during construction.
    • Air filter must be replaced upon construction completion.
  • The air handler evaporator coil, supply fan assembly and duct system must be thoroughly cleaned following final construction clean-up.
  • All air handler operating conditions must be verified according to these installation instructions.

Installing Contractor's Name

Installing Date

Installing Contractor's Phone

Air Handler Model #

Job Address

MRCOOL MAHM048ETA - Use of Air Handler During Construction - 1

flowchart
graph TD
    A["1 Duct System"] --> B["2 Integrated Control"]
    B --> C["3 Line Voltage"]
    C --> D["4 Drain Line"]
    D --> E["5 Duct Static"]
    E --> F["6 Blower Motor Amps"]
    E --> G["7 Electric Heat Amps"]
    F --> H["8 Temperature"]
    G --> I["9 Thermostat"]
    H --> J["SUPPLY AIR"]
    I --> J
    J --> K["RETURN AIR"]
    K --> L["Filter"]

① DUCT SYSTEM
SUPPLY AIR DUCT
Sealed
□ Insulated (if necessary)
☐ Registers Open and Unobstructed
RETURN AIR DUCT
Sealed
☐ Filter Installed and Clean
☐ Registers Open and Unobstructed
② INTEGRATED CONTROL
☐ Jumpers Configured Correctly (if applicable)
□ Appropriate Links in Place (if applicable)
③ VOLTAGE CHECK
□ Supply Voltage ____
□ Low Voltage ____
Electrial Connections Tight
④ DRAIN LINE
□ Leak Free

☐ Explained Operation of System to Homeowner

Technician's Name: Date Start-Up & Performance Check Completed

⑤ TOTAL EXTERNAL STATIC (dry coil)

dry coil wet coil

Supply External Static ____ ____

Return External Static ____ ____

Total External Static = ____ ____

⑥ ELECTRIC HEAT AMPS

⑦ INDOOR BLOWER AMPS

INDOOR BLOWER CFM

⑧ TEMPERATURE DROP (Cooling Mode)

Return Duct Temperature ____

Supply Duct Temperature - ____

Temperature Drop = ____

⑧ TEMPERATURE RISE (Heating Mode)

Return Duct Temperature ____

Supply Duct Temperature - ____

Temperature Rise = ____

⑨ THERMOSTAT

□ Adjusted and Programmed
☐ Operation Explained to Owner

Figure 17. Start-up and Performance Checklist (Upflow Configuration)

Installing Contractor's Name

Installing Contractor's Phone

Job Address

Installing Date

Air Handler Model #

MRCOOL MAHM048ETA - Use of Air Handler During Construction - 2

text_image ① Duct System ② Integrated Control Filter RETURN AIR ④ Drain Line Duct Static Temperature ⑤ ⑧ Disconnect Switch Thermostat Line Voltage ⑦ Blower motor Amps ⑥ Electric Heat Amps ① Duct System SUPPLY AIR

MRCOOL MAHM048ETA - Use of Air Handler During Construction - 3

① DUCT SYSTEM

SUPPLY AIR DUCT

Sealed

□ Insulated (if necessary)

□ Registers Open and Unobstructed

RETURN AIR DUCT

Sealed

Filter Installed and Clean

□ Registers Open and Unobstructed

② INTEGRATED CONTROL

□ Jumpers Configured Correctly (if applicable)

□ Appropriate Links in Place (if applicable)

③ VOLTAGE CHECK

Supply Voltage ____

□ Low Voltage ____

Electrial Connections Tight

④ DRAIN LINE

□ Leak Free

⑤ TOTAL EXTERNAL STATIC (dry coil)

dry coil wet coil

Supply External Static ____ ____

Return External Static ____ ____

Total External Static = ____ ____

⑥ ELECTRIC HEAT AMPS

⑦ INDOOR BLOWER AMPS

INDOOR BLOWER CFM

⑧ TEMPERATURE DROP (Cooling Mode)

Return Duct Temperature ____

Supply Duct Temperature - ____

Temperature Drop = ____

⑧ TEMPERATURE RISE (Heating Mode)

Return Duct Temperature ____

Supply Duct Temperature - ____

Temperature Rise = ____

⑨ THERMOSTAT

□ Adjusted and Programmed

☐ Operation Explained to Owner

☐ Explained Operation of System to Homeowner

Technician's Name: Date Start-Up & Performance Check Completed

Figure 18. Start-up and Performance Checklist (Horizontal Configuration)

MRCOOL MAHM048ETA - Use of Air Handler During Construction - 4

natural_image Abstract black-and-white graphic of stylized animal-like shapes with curved and angular forms (no text or symbols)

MRCOOL®

COMFORT MADE SIMPLE

Signature Series

MAHM\*ETA Air Handler

ELECTRICIAN and/or HVAC TECHNICIAN:

LICENSE #:

INSTALLATION DATE:

INSTALLATION LOCATION: