Advantech

SQF-CM8 920 - SSD Advantech - Free user manual and instructions

Find the device manual for free SQF-CM8 920 Advantech in PDF.

📄 20 pages English EN Download 💬 AI Question
Notice Advantech SQF-CM8 920 - page 8
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about SQF-CM8 920 Advantech

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your SSD in PDF format for free! Find your manual SQF-CM8 920 - Advantech and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SQF-CM8 920 by Advantech.

USER MANUAL SQF-CM8 920 Advantech

Safety Instructions 4

  1. Overview .... 5

  2. Features 6

  3. Specification Table....7

  4. General Description ...... 9

  5. Security Features 12

  6. Pin Assignment and Description 13

7.NVMe Command List 15

  1. Identify Device Data 16

  2. System Power Consumption 18

  3. Physical Dimension.... 19

Appendix: Part Number Table 20

Revision History

Rev.DateHistory
0.12018/5/181. Preliminary release
0.22018/8/181. Update PN information
0.32018/9/181. Update Physical Dimension (draft)
0.42019/1/231. Update performance & related information
0.52019/1/231. Update performance information
0.62019/3/51. Update sustained performance
0.72019/3/121. Update power consumption & performance
0.82019/4/121. Performance update
0.92019/5/51. Modify description
1.02019/7/11. Added function support information
1.12019/7/191. Added security description
1.22019/7/231. Performance update
1.32020/1/91. Updated Pin Assignment and Description
1.42020/2/111. Calibration product dimension
1.52020/4/91. Added power consumption information
1.62020/6/101. Added certification information.
1.72020/6/221. Added TBW data

Advantech reserves the right to make changes without further notice to any products or data herein to improve reliability, function, or design. Information furnished by Advantech is believed to be accurate and reliable. However, Advantech does not assure any liability arising out of the application or use of this information, nor the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Copyright © 1983-2020 Advantech Co., Ltd. All rights reserved.

Safety Instructions

  1. Read these safety instructions carefully.
  2. Keep this User Manual for later reference.
  3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning.
  4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible.
  5. Keep this equipment away from humidity.
  6. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage.
  7. The openings on the enclosure are for air convection. Protect the equipment from overheating. DO NOT COVER THE OPENINGS.
  8. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet.
  9. Position the power cord so that people cannot step on it. Do not place anything over the power cord.

  10. All cautions and warnings on the equipment should be noted.

  11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage.

  12. Never pour any liquid into an opening. This may cause fire or electrical shock.

  13. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel.

  14. If one of the following situations arises, get the equipment checked by service personnel:

• The power cord or plug is damaged.
• Liquid has penetrated the equipment.
- The equipment has been exposed to moisture.
• The equipment does not work well, or you cannot get it to work according to the user's manual.
- The equipment has been dropped and damaged.
• The equipment has obvious signs of breakage.

  1. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW -20°C (-4°F) OR ABOVE 60°C (140°F). THIS COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT.

  2. CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER, DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS.

Specifications subject to change without notice, contact your sales representatives for the most update information.

1. Overview

Advantech SQFlash 920 series M.2 2280 PCIe SSD (Solid State Drive) delivers all the advantages of flash disk technology with PCIe Gen3 x4 interface, including being compliant with standard M.2 2280 (M Key) form factor. The device is designed to operate at a maximum operating frequency of 200MHz with 25MHz external crystal. Its capacity could provide a wide range up to 1.9TB. Moreover, it can reach up to 3,400MB/s read as well as 2,700MB/s write high performance based on Toshiba 64-layer 3D TLC Flash.

2. Features

■ PCIe Interface

  • Compliant with NVMe1.3
  • Compatible with PCIe I/II/III x4 interface
    – Support up to queue depth 64K
    – Support power management

■ Operating Voltage : 3.3V

■ Support LDPC with RAID ECC

■ AES256、TCG-OPAL、TRIM、AHCI supported

■ Hardware Quick Erase supported (optional)

■ Voltage Stabilizer supported (optional)

■ Temperature Ranges ^1

  • Commercial Temperature
  • 0°C to 70°C for operating
  • -40°C to 85°C for storage

– Industrial Temperature

- -40°C to 85°C for operating

- -40°C to 85°C for storage

*Note : 1. Based on SMART Attribute (Byte index [2 :1] of PCIe-SIG standard, which measured by thermal sensor

■ Mechanical Specification

  • Shock : 1,500G / 0.5ms
  • Vibration : 20G / 80\~2,000Hz

■ Humidity

- Humidity: 5% \~ 95% under 55°C

■ Acquired RoHS、WHQL、CE、FCC Certificate

■ Acoustic : 0 dB

■ Dimension : 80.0 mm x 22.0 mm x 7.3 mm

3. Specification Table

■ Performance

Sequential (MB/sec)Random (IOPS @4K)
ReadWriteReadWrite
3D TLC(BiCS3)240 GB30001000160K237K
480 GB34002100357K445K
960 GB34002700350K230K
1920 GB34002700360K199K

* Performance measured by IOMeter with QD32, 8GB data pattern, SLC pool enable & adjustable by request.

■ Endurance

JEDEC defined an endurance rating TBW (TeraByte Written), following by the equation below, for indicating the number of terabytes a SSD can be written which is a measurement of SSDs' expected lifespan, represents the amount of data written to the device.

TBW = [(NAND Endurance) x (SSD Capacity)] / WAF

• NAND Endurance: Program / Erase cycle of a NAND flash.

  • SLC: 100,000 cycles
  • Ultra MLC: 30,000 cycles
  • MLC: 3,000 cycles
  • 3D TLC (BiCS3): 3,000 cycles

- SSD Capacity: SSD physical capacity in total of a SSD.

- WAF: Write Amplification Factor (WAF), as the equation shown below, is a numerical value representing the ratio between the amount of data that a SSD controller needs to write and the amount of data that the host's flash controller writes. A better WAF, which is near to 1, guarantees better endurance and lower frequency of data written to flash memory.

WAF = (Lifetime write to flash) / (Lifetime write to host)

- Endurance measurement is based on New JEDEC 219 Client Workload and verified with following workload conditions,

  • PreCond%full = 100%
  • Trim commands enabled
  • Random data pattern.
3D TLC (BiCS3)WAFTBWDWPD*
240 GB2.03801.45
480 GB1.818501.62
960 GB1.8516651.58
1920 GB1.9731151.48

* Endurance of 1 drive writes per day (DWPD) for 3 years

- Pure sequential workload conditions, fio seq write, 30 loops, bs 128k, io depth 32 (Copy the pattern by VDbench)

3D TLC (BiCS3)WAFTBWDWPD*
240 GB1.057142.74
480 GB1.0514292.72
960 GB1.0528572.72
1920 GB1.0557142.72

* Endurance of 1 drive writes per day (DWPD) for 3 years

4. General Description

■ Error Correction Code (ECC)

Flash memory cells will deteriorate with use, which might generate random bit errors in the stored data. Thus, SQFlash 920 series PCIe SSD applies the LDPC with RAID ECC algorithm, which can detect and correct errors occur during read process, ensure data been read correctly, as well as protect data from corruption.

■ Wear Leveling

NAND flash devices can only undergo a limited number of program/erase cycles, and in most cases, the flash media are not used evenly. If some areas get updated more frequently than others, the lifetime of the device would be reduced significantly. Thus, Wear Leveling is applied to extend the lifespan of NAND Flash by evenly distributing write and erase cycles across the media.

SQFlash provides advanced Wear Leveling algorithm, which can efficiently spread out the flash usage through the whole flash media area. Moreover, by implementing both dynamic and static Wear Leveling algorithms, the life expectancy of the NAND flash is greatly improved.

■ Bad Block Management

Bad blocks are blocks that include one or more invalid bits, and their reliability is not guaranteed. Blocks that are identified and marked as bad by the manufacturer are referred to as "Initial Bad Blocks". Bad blocks that are developed during the lifespan of the flash are named "Later Bad Blocks". SQFlash implements an efficient bad block management algorithm to detect the factory-produced bad blocks and manages any bad blocks that appear with use. This practice further prevents data being stored into bad blocks and improves the data reliability.

■ Power Loss Protection

- Flush Manager

Power Loss Protection is a mechanism to prevent data loss during unexpected power failure. DRAM is a volatile memory and frequently used as temporary cache or buffer between the controller and the NAND flash to improve the SSD performance. However, one major concern of the DRAM is that it is not able to keep data during power failure. Accordingly, SQFlash SSD applies the Flush Manager technology, only when the data is fully committed to the NAND flash will the controller send acknowledgement (ACK) to the host. Such implementation can prevent false-positive performance and the risk of power cycling issues. In addition, it is critical for a controller to shorten the time the in-flight data stays in the controller internal cache. Thus, SQFlash applies an algorithm to reduce the amount of data resides in the cache to provide a better performance. With Flush Manager, incoming data would only have a "pit stop" in the cache and then move to NAND flash directly. Also, the onboard DDR will be treated as an "organizer" to consolidate incoming data into groups before written into the flash to improve write amplification.

- Voltage Stabilizer

While the built-in voltage detector detects an unstable power input (< 3.135 V or > 3.465 V), the controller will issue a power failure interrupt and force a Flush CMD first. At the same time, the whole internal power supply will be switched to Voltage Stabilizer immediately to ensure stable power is supplied throughout the whole drive. This ensures the Flash IC and DDR IC will not operate with unstable power which could lead to data errors or bad data integrity.

TRIM

TRIM is a feature which helps improve the read/write performance and speed of solid-state drives (SSD). Unlike hard disk drives (HDD), SSDs are not able to overwrite existing data, so the available space gradually becomes smaller with each use. With the TRIM command, the operating system can inform the SSD which blocks of data are no longer in use and can be removed permanently. Thus, the SSD will perform the erase action, which prevents unused data from occupying blocks all the time.

SMART

SMART, an acronym for Self-Monitoring, Analysis and Reporting Technology, is an open standard that allows a hard disk drive to automatically detect its health and report potential failures. When a failure is recorded by SMART, users can choose to replace the drive to prevent unexpected outage or data loss. Moreover, SMART can inform users of impending failures while there is still time to perform proactive actions, such as copy data to another device.

■ Over-Provision

Over Provisioning refers to the inclusion of extra NAND capacity in a SSD, which is not visible and cannot be used by users. With Over Provisioning, the performance and IOPS (Input/Output Operations per Second) are improved by providing the controller additional space to manage P/E cycles, which enhances the reliability and endurance as well. Moreover, the write amplification of the SSD becomes lower when the controller writes data to the flash.

■ Thermal Throttling

Thermal Throttling function is for protecting the drive and reducing the possibility of read / write error due to overheat. The temperature is monitored by the thermal sensor. As the operating temperature continues to increase to threshold temperature, the Thermal Throttling mechanism is activated. At this time, the performance of the drive will be significantly decreased to avoid continuous heating. When the operating temperature falls below threshold temperature, the drive can resume to normal operation.

■ Block Diagram

Advantech SQF-CM8 920 - ■ Block Diagram - 1

flowchart
graph TD
    A["Flash"] --> B["DDR3/4 Cache"]
    C["Flash"] --> D["PS5012-E12 Flash Controller"]
    E["Flash"] --> D
    F["PCIe Power"] --> G["PCIe Signal"]

■ LBA value

Density (GB)LBA
240468,862,128
480937,703,088
9601,875,385,008
19203,750,748,848

5. Security Features

■ Advanced Encryption Standard (AES)

An AES 256-bit encryption key is generated in the drive's security controller before the data got stored on the NAND flash. When the controller or firmware fails, the data that is securely stored in the encryption key becomes inaccessible through the NAND flash.

■ TCG-OPAL 2.0 Compliance

TCG-OPAL compliance SED (Self-encryption Drive) supports a built-in shadow MBR to process user authentication to SSD before booting to normal MRR area and OS. SQFlash 920 series supports such feature with 100% TCG-OPAL compliance. Further, with SQFlash Flash Lock function, the user authentication process in shadow MBR can be done automatically by bonding with motherboard unique ID such as UUID in BIOS / MAC address / TPM unique code. So with Flash Lock enabled, only designated motherboard can have access to the SSD.

■ Flash Vault

Flash Vault is to lock Read and Write command by SSD firmware setting and make the SSD need password to verify and only operate with the corresponding platform. User can use Flash Vault to prevent data being stolen by reading the SQFlash SSD with other computers and unauthorized person.

■ Security ID

Security ID is to encrypt user's specific application software encryption. To enable this function, the application software is required to build Security ID function code and user needs to enable the firmware function by entering Access Code of SQFlash Utility, and then the Security ID can be set. When Security ID sets, the application software is protected by Security ID and SQFlash Utility

  1. Pin Assignment and Description
Pin No.PCIe PinDescription
1GNDGround
23.3V3.3V source
3GNDGround
43.3V3.3V source
5PETn3PCIe TX Differential signal defined by the PCIe 3.0 specification
6N/CNo connect
7PETp3PCIe TX Differential signal defined by the PCIe 3.0 specification
8N/CNo connect
9GNDGround
10LED1#(O)Status indicators via LED devices
11PERn3PCIe RX Differential signal defined by the PCIe 3.0 specification
123.3V3.3V source
13PERp3PCIe RX Differential signals defined by the PCIe 3.0 specification.
143.3V3.3V source
15GNDGround
163.3V3.3V source
17PETn2PCIe TX Differential signal defined by the PCIe 3.0 specification
183.3V3.3V source
19PETp2PCIe TX Differential signal defined by the PCIe 3.0 specification
20N/CNo connect
21GNDGround
22N/CNo connect
23PERn2PCIe RX Differential signal defined by the PCIe 3.0 specification
24N/CNo connect
25PERp2PCIe RX Differential signal defined by the PCIe 3.0 specification
26N/CNo connect
27GNDGround
28N/CNo connect
29PETn1PCIe TX Differential signal defined by the PCIe 3.0 specification
30N/CNo connect
31PETp1PCIe TX Differential signal defined by the PCIe 3.0 specification
32N/CNo connect
33GNDGround
34N/CNo connect
35PERn1PCIe RX Differential signal defined by the PCIe 3.0 specification
36N/CNo connect
37PERp1PCIe RX Differential signal defined by the PCIe 3.0 specification
38N/CNo connect
39GNDGround
40SMB_CLK (I/O)(0/1.8V)SMBus Clock; Open Drain with pull-up on platform (Reserve)
41PETn0PCIe TX Differential signal defined by the PCIe 3.0 specification
42SMB_DATA (I/O)(0/1.8V)SMBus Data; Open Drain with pull-up on platform (Reserve)
43PETp0PCIe TX Differential signal defined by the PCIe 3.0 specification
44N/CNo connect
45GNDGround
46N/CNo connect
47PERn0PCIe RX Differential signal defined by the PCIe 3.0 specification
48N/CNo connect
49PERp0PCIe RX Differential signal defined by the PCIe 3.0 specification
50PERST#(I)(0/3.3V)PE-Reset is a functional reset to the card as defined by the PCIe Mini CEM specification.
51GNDGround

Specifications subject to change without notice, contact your sales representatives for the most update information.

52CLKREQ#(I/O)(0/3.3V)Clock Request is a reference clock request signal as defined by the PCIe Mini CEM specification; Also used by L1 PM Substates.
53REFCLKnPCIe Reference Clock signals (100 MHz)defined by the PCIe 3.0 specification.
54PEWAKE#(I/O)(0/3.3V)PCIe PME Wake.Open Drain with pull up on platform; Active Low.
55REFCLKpPCIe Reference Clock signals (100 MHz)defined by the PCIe 3.0 specification.
56Reserved forMFG DATAManufacturing Data line. Used for SSD manufacturing only.Not used in normal operation.Pins should be left N/C in platform Socket.
57GNDGround
58Reserved for MFGCLOCKManufacturing Clock line. Used for SSD manufacturing only.Not used in normal operation.Pins should be left N/C in platform Socket.
59Module KeyModule Key
60Module Key
61Module Key
62Module Key
63Module Key
64Module Key
65Module Key
66Module Key
67N/CNo connect
68N/CNo connect
69PEDET (NC-PCIe)Host I/F Indication; No Connect for PCIe.
703.3V3.3V source
71GNDGround
723.3V3.3V source
73GNDGround
743.3V3.3V source
75GNDGround

7. NVMe Command List

■ Admin commands

OpcodeCommand Description
00hDelete I/O Submission Queue
01hCreate I/O Submission Queue
02hGet Log Page
04hDelete I/O Completion Queue
05hCreate I/O Completion Queue
06hIdentify
08hAbort
09hSet Features
0AhGet Features
0ChAsynchronous Event Request
10hFirmware Activate
11hFirmware Image Download
I/O Command Set Specific
80hFormat NVM
81hSecurity Send
82hSecurity Receive
83h-BFhI/O Command Set specific
Vendor Specific
C0h-FFhVendor specific

■ NVM commands

OpcodeCommand Description
00hFlush
01hWrite
02hRead
04hWrite Uncorrectable
05hCompare
08hWrite Zeroes
09hDataset Management
0DhReservation Register
0EhReservation Report
11hReservation Acquire
15hReservation Release
Vendor Specific
80h – FFhVendor specific

8. Identify Device Data

The Identity Device Data enables Host to receive parameter information from the device. The parameter words in the buffer have the arrangement and meanings defined in below table. All reserve bits or words are zero

■ Identify Controller Data Structure

BytesDescription
Controller Capabilities and Features
01:00PCI Vendor ID (VID)
03:02PCI Subsystem Vendor ID (SSVID)
23:04Serial Number (SN)
63:24Model Number (MN)
71:64Firmware Revision (FR)
72Recommended Arbitration Burst (RAB)
75:73IEEE OUI Identifier (IEEE)
76Controller Multi-Path I/O and Namespace Sharing Capabilities (CMIC)
77Maximum Data Transfer Size (MDTS)
255:80Reserved
Admin Command Set Attributes & Optional Controller Capabilities
257:256Optional Admin Command Support (OACS)
258Abort Command Limit (ACL)
259Asynchronous Event Request Limit (AERL)
260Firmware Updates (FRMW)
261Log Page Attributes (LPA)
262Error Log Page Entries (ELPE)
263Number of Power States Support (NPSS)
264Admin Vendor Specific Command Configuration (AVSCC)
265Autonomous Power State Transition Attributes (APSTA)
511:266Reserved
NVM Command Set Attributes
512Submission Queue Entry Size (SQES)
513Completion Queue Entry Size (CQES)
515:514Reserved
519:516Number of Namespaces (NN)
521:520Optional NVM Command Support (ONCS)
523:522Fused Operation Support (FUSES)
524Format NVM Attributes (FNA)
525Volatile Write Cache (VWC)
527:526Atomic Write Unit Normal (AWUN)
529:528Atomic Write Unit Power Fail (AWUPF)
530NVM Vendor Specific Command Configuration (NVSCC)
531Reserved
533:532Atomic Compare & Write Unit (ACWU)
535:534Reserved
539:536SGL Support (SGLS)
703:540Reserved

■ Identify Namespace Data Structure & NVM Command Set Specific

BytesDescription
7:0Namespace Size (NSZE)
15:8Namespace Capacity (NCAP)
23:16Namespace Utilization (NUSE)
24Namespace Features (NSFEAT)
25Number of LBA Formats (NLBAF)
26Formatted LBA Size (FLBAS)
27Metadata Capabilities (MC)
28End-to-end Data Protection Capabilities (DPC)
29End-to-end Data Protection Type Settings (DPS)
30Namespace Multi-path I/O and Namespace Sharing Capabilities (NMIC)
31Reservation Capabilities (RESCAP)
119:32Reserved
127:120IEEE Extended Unique Identifier (EUI64)
131:128LBA Format 0 Support (LBAF0)
135:132LBA Format 1 Support (LBAF1)
139:136LBA Format 2 Support (LBAF2)
143:140LBA Format 3 Support (LBAF3)
147:144LBA Format 4 Support (LBAF4)
151:148LBA Format 5 Support (LBAF5)
155:152LBA Format 6 Support (LBAF6)
159:156LBA Format 7 Support (LBAF7)
163:160LBA Format 8 Support (LBAF8)
167:164LBA Format 9 Support (LBAF9)
171:168LBA Format 10 Support (LBAF10)
175:172LBA Format 11 Support (LBAF11)
179:176LBA Format 12 Support (LBAF12)
183:180LBA Format 13 Support (LBAF13)
187:184LBA Format 14 Support (LBAF14)
191:188LBA Format 15 Support (LBAF15)
383:192Reserved
4095:384Vendor Specific (VS)

■ List of Device Identification for Each Capacity

Capacity(GB)Byte[7:0]:Namespace Size (NSZE)
2401BF244B0h
48037E436B0h
9606FC81AB0h
1920DF8FE2B0h

9. System Power Consumption

■ Supply Voltage

ParameterRating
Operating Voltage3.3V

■ Power Consumption

(W)ReadWriteIdle
3D TLC (BiCS3)240 GB5.02.61.5
480 GB5.53.21.5
960 GB5.54.81.8
1920 GB5.55.51.8

10. Physical Dimension

M.2 2280 PCIe SSD (Unit: mm)

Advantech SQF-CM8 920 - Physical Dimension - 1

text_image 5.10 1.40 80 80 22 0.80 ADANTECH

Advantech SQF-CM8 920 - Physical Dimension - 2

Appendix: Part Number Table

ProductAdvantech PN
SQF 920 NVMe M.2 2280 SSD (OPAL) 240G 3D TLC (BiCS3) (0~70°C)SQF-CM8V4-240G-ECC
SQF 920 NVMe M.2 2280 SSD (OPAL) 480G 3D TLC (BiCS3) (0~70°C)SQF-CM8V4-480G-ECC
SQF 920 NVMe M.2 2280 SSD (OPAL) 960G 3D TLC (BiCS3) (0~70°C)SQF-CM8V4-960G-ECC
SQF 920 NVMe M.2 2280 SSD (OPAL) 1920G 3D TLC (BiCS3) (0~70°C)SQF-CM8V4-1K9G-ECC
SQF 920 NVMe M.2 2280 SSD (OPAL) 240G 3D TLC (BiCS3) (-40~85°C)SQF-CM8V4-240G-ECE
SQF 920 NVMe M.2 2280 SSD (OPAL) 480G 3D TLC (BiCS3) (-40~85°C)SQF-CM8V4-480G-ECE
SQF 920 NVMe M.2 2280 SSD (OPAL) 960G 3D TLC (BiCS3) (-40~85°C)SQF-CM8V4-960G-ECE
SQF 920 NVMe M.2 2280 SSD (OPAL) 1920G 3D TLC (BiCS3) (-40~85°C)SQF-CM8V4-1K9G-ECE
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Advantech

Model : SQF-CM8 920

Category : SSD