GE

AEW05LXB - Washing machine GE - Free user manual and instructions

Find the device manual for free AEW05LXB GE in PDF.

📄 28 pages English EN Download 💬 AI Question
Notice GE AEW05LXB - page 2
View the manual : English EN Español ES
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about AEW05LXB GE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Washing machine in PDF format for free! Find your manual AEW05LXB - GE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AEW05LXB by GE.

USER MANUAL AEW05LXB GE

Safety Instructions....2,3

Recycle Information 3

Operating Instructions

Controls 4-6

Care and Cleaning

Air Filter 6

Outdoor Coils 6

Installation Instructions.....7-10

Troubleshooting Tips....11

Normal Operating Sounds 11

Consumer Support

Consumer Support .... Back Cover

Warranty 14

Owner's Manual and Installation Instructions

AET05

AEW05

AEY05

AEZ05

AEW06

AEZ06

AEW08

AEZ08

Write the model and serial numbers here:

Model # ____

Serial # ____

Find these numbers on a label on the side of the air conditioner.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

GE AEW05LXB - WARNING! - 1

SAFETY PRECAUTIONS

Use this appliance only for its intended purpose as described in this Owner's Manual.
This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
■ Turn the unit OFF and unplug your air conditioner before cleaning.
GE does not support any servicing of the air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.

For your safety...do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
These R410A air conditioning systems require contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant. DO NOT use equipment certified for R22 refrigerant only.

GE AEW05LXB - SAFETY PRECAUTIONS - 1

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

DO NOT use an adapter plug with this appliance.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

WARNING!

GE AEW05LXB - WARNING! - 1

USE OF EXTENSION CORDS

RISK OF FIRE. Could cause serious injury or death.

  • DO NOT use an extension cord with this Window Air Conditioner.
  • DO NOT use surge protectors or multi-outlet adaptors with this Window Air Conditioner.

GE AEW05LXB - USE OF EXTENSION CORDS - 1

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

RECYCLING INFORMATION

For appliance recycling information please visit www.geappliances.com/recycling.

Features and appearance will vary.

Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

GE AEW05LXB - USE OF EXTENSION CORDS - 2

text_image Light indicates the unit is in the temperature or delay time Set mode. 88 Set Temp / Delay Auto High Cool Med Energy Saver Low Fan Only Fan Speed Mode Delay 1-24hr ( on some models ) Light indicates the delay timer is set. 88 Set Auto High Cool Med Energy Saver Low Fan Only Fan Speed Mode Temp / Delay Delay 1-24hr Power ( on some models ) NOTE: The display always shows the room temperature except when setting the Set temperature or the Delay timer. Light indicates the delay timer is set.

GE AEW05LXB - USE OF EXTENSION CORDS - 3

text_image Delay1-24hr 7 Delaytimer Decrease 4 Mode select 6 Fan speed Decrease 5 Temperature set Increase and Decrease 3 Delay - + - Auto - + - Fan o Temp - + - Power 4 Delaytimer Increase 5 AutoFanon 5 Fan speed Increase Unitpower on/off 1

Remote Control

Air Conditioner Controls

Controls (on some models)

GE AEW05LXB - Controls (on some models) - 1

1 Power Pad

Turns air conditioner on and off. When turned on, the display will show the room temperature.

2 Display

Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.

NOTE: The display will change to show the room temperature after settings have been made.

3 Temp Increase ▲ / Decrease ▼ Pads

Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while setting.

4 Delay Timer Increase ▲ (+) / Decrease ▼ (−) Pads

Each touch of the Increase ▲/ Decrease▼ pads on the unit or the Increase + / Decrease - pads on the remote control will set the delay time when using the Delay 1–24hr timer. The Set light will turn on while setting.

5 Fan Speed Pads

Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease – pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.

6 Mode Pad

Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.

7 Delay Pads/Delay 1-24hr Pad

Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.

Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.

How to set:

Press the Delay 1–24hr pad on the unit or the Delay pad on the remote control. Each touch of the Increase ▲/ Decrease ▼ pads on the unit or the Increase +/ Decrease – pads on the remote control will set the timer in 1-hour intervals. The Set light will turn on while setting.

To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or the Delay pad on the remote control. Use the Increase ▲/ Decrease▼ pads on the unit or the Increase +/ Decrease – pads on the remote control to set a new time if desired.

To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.

Features and appearance will vary.

GE AEW05LXB - How to set: - 1

flowchart
graph TD
    A["High Cool"] --> B["Low Cool"]
    B --> C["Low Fan"]
    C --> D["OFF"]
    D --> E["Hi Fan"]
    E --> F["MODE"]

GE AEW05LXB - How to set: - 2

text_image Coolest TEMP 1** 2 3 4 5 6 7

1 MODE CONTROL TEMPERATURE CONTROL

GE AEW05LXB - How to set: - 3

Controls (on some models)

1 Mode Control

High Cool and Low Cool provide cooling with different fan speeds.

Fan settings provide air circulation and filtering without cooling.

NOTE: If you move the mode control from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.

Cooling Descriptions

For Normal Cooling—Select High Cool or Low Cool with the TEMPERATURE control at midpoint.

For Maximum Cooling—Select High Cool with the TEMPERATURE control at the highest number available on your knob.

For Quieter and Nighttime Cooling—Select Low Cool with the TEMPERATURE control at midpoint.

2 TEMP Control

The TEMP control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

About the controls on the air conditioner.

Do Not Operate in Freezing Outdoor ConditionsThis cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used infreezing outdoor conditions.
Remote ControlTo ensure proper operation, aim the remote control at the signal receiver on the air conditioner.Make sure nothing is between the air conditioner and the remote control that could block the signal.The remote control signal has a range of up to 20 feet.Make sure batteries are fresh and installed correctly as indicated on the remote control.Remote contains a magnet allowing it to attach to metal surfaces.
Cool ModeUse the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase ▲ / Decrease ▼ pads to set the desired temperature between 64°F and 86°F in 1°F increments.An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan settingto a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.Cooling DescriptionsFor Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.For Quieter and Nighttime Cooling—Select the Cool mode and Low fan with a middle set temperature.
Energy Saver ModeControls the fan.ON—The fan will cycle on and off with the compressor. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.OFF—The fan runs all the time, while the compressor cycles on and off.
Fan Only ModeUse the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.
Auto Fan SpeedSet to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.
Power Outage Recovery FeatureIn the case of a power outage or interruption, the unit will automatically restart in the settings last used after the power is restored. If the Delay 1–24hrfeature was set, it will resume countdown. You may need to set a new time if desired.

Additional important information.

Air Direction

Use the lever to adjust the air direction left and right only.

GE AEW05LXB - Air Direction - 1

natural_image Line drawing of an electric air conditioner unit with a hand pointing to the front panel (no text or symbols)

Care and cleaning of the air conditioner.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

To remove:

Pull the tab on the right side of the unit until the filter is out.

To remove:

Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45° position. Remove the filter.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.

GE AEW05LXB - To remove: - 1

natural_image Illustration of a portable air conditioner unit with a hand inserting a card into its side panel (no text or symbols)

⚠️ CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

GE AEW05LXB - To remove: - 2

text_image Tab Tab

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

GE AEW05LXB - Outdoor Coils - 1

natural_image Simple line drawing of a cabinet or enclosure with vertical bars on both sides (no text or symbols)

How to Insert the Batteries in the Remote Control

1 Remove the battery cover by sliding it according to the arrow direction.
2 Insert new batteries, making sure that the (+) and (−) of battery are installed correctly.
3 Reattach the cover by sliding it back into position.

NOTES:

Use 2 "AAA" (1.5 volt) alkaline batteries. Do not use rechargeable batteries.
Remove the batteries from the remote control if the system is not going to be used for a long time.
Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or rechargeable (ni-cad, ni-mh, etc) batteries.

Installation Instructions

Air Conditioner

GE AEW05LXB - Air Conditioner - 1

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com

In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca

GE AEW05LXB - Air Conditioner - 2

BEFORE YOU BEGIN

Read these instructions completely and carefully.

  • IMPORTANT — Save these instructions for local inspector's use.
  • IMPORTANT – Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – Installation of this appliance requires basic mechanical skills.
    • Completion time –Approximately 1 hour
    • We recommend that two people install this product.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.
  • You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.

GE AEW05LXB - BEFORE YOU BEGIN - 1

ELECTRICAL REQUIREMENTS

GE AEW05LXB - ELECTRICAL REQUIREMENTS - 1

Some models require a 115/120-volt AC, 60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

GE AEW05LXB - ELECTRICAL REQUIREMENTS - 2

Some models require 230/208-volt AC, protected with a time-delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

CAUTION:

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

TOOLS YOU WILL NEED
GE AEW05LXB - CAUTION: - 1

natural_image Line drawing of a screwdriver with a magnified inset showing the tip (no text or symbols)

Phillips head screwdriver

GE AEW05LXB - CAUTION: - 2

Flat-blade screwdriver
GE AEW05LXB - CAUTION: - 3

GE AEW05LXB - CAUTION: - 4
Ruler or tape measurePencil

GE AEW05LXB - CAUTION: - 5
Level

GE AEW05LXB - CAUTION: - 6
Scissors or knife

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

GE AEW05LXB - CAUTION: - 7

text_image PARTS INCLUDED (Appearance may vary) Top mounting rail Foam top window gasket Window sash seal Air conditioner Left accordion panel Right accordion panel Top mounting rail seal strip Type A (4) Type B (6) Window locking bracket (1)

1 WINDOW REQUIREMENTS

  • These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
  • The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
  • All supporting parts must be secured to firm wood, masonry or metal.
  • The electrical outlet must be within reach of the power cord.
  • Follow the dimensions in the table and illustration for your model.
Models A B
AET05, AEY05AEW05, AEZ0512 1/2" min.23"-38"
AEW06, AEZ06AEW08, AEZ0813 1/2" min.22 1/2"-38"

GE AEW05LXB - WINDOW REQUIREMENTS - 1

text_image (With accordion panels)

3 ATTACH THE TOP MOUNTING RAIL SEAL STRIP

(Some models may have the seal strip already attached to the top mounting rail. If applicable, skip this step.)

Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top mounting rail, along the front edge.

GE AEW05LXB - ATTACH THE TOP MOUNTING RAIL SEAL STRIP - 1

text_image Top mounting rail Remove backing from seal strip FRONT VIEW Top mounting rail Seal strip

2 STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.

WOOD PIECES

WIDTH: 2"

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the sill to make it 1/2" higher than the top of the storm window frame or the vinyl frame.

Attach securely with nails or screws provided by the installer.

GE AEW05LXB - STORM WINDOW REQUIREMENTS - 1

text_image 1/2" higher than vinyl frame (on some windows) 1/2" higher than storm window frame Wood Sill Vinyl frame Storm window frame

4 PREPARE THE AIR CONDITIONER

A Install the top mounting rail with 4 Type A screws from the outside of the case.

GE AEW05LXB - PREPARE THE AIR CONDITIONER - 1

text_image Top mounting rail Bottom mounting rail

B Hold the accordion panel in one hand and gently pull back to free the open end.

GE AEW05LXB - PREPARE THE AIR CONDITIONER - 2

natural_image Diagram of two hands holding a heat exchanger with arrows indicating direction (no text or symbols)

4 PREPARE THE AIR CONDITIONER (cont.)

C Slide the free end of the accordion panel into the side panel rails. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.

NOTE: There is a right and a left accordion panel. Be sure to use the proper panel for each side.

GE AEW05LXB - PREPARE THE AIR CONDITIONER (cont.) - 1

natural_image Diagram showing airflow or ventilation system between a mounted air conditioner unit and a smaller unit (no text or symbols present)

D Slide the left and right accordion panels into the top and bottom mounting rails.

GE AEW05LXB - PREPARE THE AIR CONDITIONER (cont.) - 2

text_image Top left Top mounting rail Top right Bottom mounting rail

5 PREPARE THE WINDOW

Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.

GE AEW05LXB - PREPARE THE WINDOW - 1

natural_image Line drawing of a window frame structure with no text or symbols

6 INSTALL THE AIR CONDITIONER IN THE WINDOW

A Place the air conditioner on the sill with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail. It should be level or slightly tilted to the outside. Use a level; about a 1/3 bubble will be the correct case slant to the outside.

GE AEW05LXB - INSTALL THE AIR CONDITIONER IN THE WINDOW - 1

text_image or or Type B screws

B Extend the left and right accordion panels to the vertical window sashes and attach, through the holes in the panels, with 5 Type B screws, as appropriate.

7 INSTALL SUPPORT BRACKET AND FOAM TOP WINDOW GASKET

A CAUTION:

To prevent broken glass or damage to windows, on vinyl or other similarly constructed windows, attach the window locking bracket to the window side jamb with one Type B screw.

GE AEW05LXB - A CAUTION: - 1

text_image Vinyl Wood

B Cut the foam top window gasket to the window width.

C Stuff the foam between the glass and the window to prevent air and insects from getting into the room.

GE AEW05LXB - A CAUTION: - 2

natural_image Hand holding a tool interacting with a window or panel (no text or symbols visible)

NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.

Problem Possible Causes What To Do
Air conditioner does not startbreaker is tripped. the fuse or reset the breaker. used after the power is restored.The air conditioner is unplugged.Make sure the air conditioner plug is pushed completely into the outlet.
The fuse is blown/circuitCheck the house fuse/circuit breaker box and replace
Power failure.The unit will automatically restart in the settings last
There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.
The current interrupter device is tripped. use of the air conditionerPress the RESET button located on the power cord plug.If the RESET button will not stay engaged, discontinue and contact a qualified service technician.
Air conditioner does not cool as it should knob to a higher number. to allow time for the roomAirflow is restricted.Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner.
The temp control may not be set correctly.On models with touch pads: In the Cool mode, press the Decrease ▼ pad.On models with control knobs, turn the temperature
The air filter is dirty.Clean the filter at least every 30 days.See the Care and Cleaning section.
The room may have been hot. to cool down.When the air conditioner is first turned on, you need
Cold air is escaping.Check for open furnace registers and cold air returns.
Cooling coils have iced up.See “Air conditioner freezing up” below.
Air conditioner freezing upIce blocks the air flow and stops the air conditioner from cooling the room.On models with control knobs, set the mode control at High Fan or High Cool with the Temp at 1 or 2.On models with touch pads, set the controls at High Fan or High Cool and set the thermostat to a higher temperature.
The remote control is not workingThe batteries are inserted incorrectly.Check the position of the batteries. They should be inserted in the opposite (+) and (-) direction.
The batteries may be dead.Replace the batteries.
Water drips outsideHot, humid weather.This is normal.
Water drips indoorsThe air conditioner is not tilted to the outside.For proper water disposal, make sure the air conditioner slants slightly from the case front to the rear.
Water collects in base panMoisture removed from air and drains into base pan.This is normal for a short period in areas with little humidity; normal for a longer period in very humid areas.

Normal Operating Sounds

You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
You may hear the thermostat click when the compressor cycles on and off.

Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
The fan may run even when the compressor does not.

Staple your receipt here.

Proof of the original purchase date is

needed to make a warranty claim.

For The Period Of: We Will Replace:

One Year

From the date of the original purchase

Replacement unit for any product which fails due to a defect in materials or workmanship.

The replacement unit is warranted for the remainder of your product's original one-year warranty period. The replacement unit may either be a new unit or a refurbished unit.

In Order to Make a Warranty Claim During the First 30 Days from the Date of Original Purchase:

■ Properly pack your unit. We recommend using the original carton and packing materials.
- Return the product to the retail location where it was purchased.

■ Include in the package a copy of the sales receipt or other evidence of date of original purchase. Also print your name and address and a description of the defect.

In Order to Make a Warranty Claim During the Remainder of the One-Year Warranty:

  • Locate your original sales receipt and make a note of your model and serial number.
  • Call GE at 1.866.907.1655 to initiate the product replacement process.
  • You will be asked to provide your name, address, date of purchase, model and serial number.
    ■ GE will arrange for a carton to be sent to your home to recover the product.

  • You must return the product (postage pre-paid by GE) to GE's recovery center before a replacement unit will be provided. Please include a description of the defect.

  • You should receive your replacement product within 7 to 10 business days after your unit is received.

What Is Not Covered:

  • Customer instruction. This owner's manual provides information regarding operating instructions and user controls.
  • Improper installation. If you have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
  • Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.

■ Replacement of house fuses or resetting of circuit breakers.
- Failure due to corrosion on models not corrosion-protected.
■ Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
■ Incidental or consequential damage caused by possible defects with this air conditioner.
■ Damage caused after delivery.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product replacement as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state's Attorney General.

Exclusion of implied warranties: Except where prohibited or restricted by law, there are no warranties, whether express, oral or statutory which extend beyond the description on the face hereof, including specifically the implied warranties of merchantability or fitness for a particular purpose.

natural_image Line drawing of an electric air conditioner unit with ventilation grilles and a hand pointing to the front panel (no text or symbols)
natural_image Illustration of a portable air conditioner unit with a hand inserting a card into its side panel (no text or symbols)

GE AEW05LXB - What Is Not Covered: - 1

text_image Lengüetas Lengüetas
natural_image Simple line drawing of a rectangular box with vertical slats, no text or symbols present
natural_image Diagram of a screwdriver with a magnified inset showing the tip (no text or symbols)
natural_image Pure technical line drawing of a mechanical component with no text or symbols

GE AEW05LXB - What Is Not Covered: - 2

natural_image Simple line drawing of a vertical slatted structure with a base (no text or symbols)

GE AEW05LXB - What Is Not Covered: - 3

natural_image Diagram of two hands holding a corrugated heat sink with arrows indicating direction (no text or symbols)

4 PREPARE EL ACONDICIONADOR DE AIRE (cont.)

natural_image Diagram of a double door HVAC system with airflow arrows indicating cooling or ventilation (no text or symbols)
natural_image Technical line drawing of a structural frame with a curved cutout (no text or symbols)

6 INSTALE EL ACONDICIONADOR DE AIRE EN LA VENTANA

natural_image Simple line drawing of a hand holding a knife over a rectangular object (no text or symbols)

General Manager, Customer Relations

GE Appliances, Appliance Park

Louisville, KY 40225

GE AEW05LXB - What Is Not Covered: - 4

GE Appliances Website

In the U.S.A.: GEAppliances.com

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner's Manuals, or even order parts on-line. In Canada: www.GEAppliances.ca

GE AEW05LXB - In the U.S.A.: GEAppliances.com - 1

Real Life Design Studio In the U.S.A.: GEAppliances.com

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE's Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD. GEAC (800.833.4322).

In Canada, contact: Manager, Consumer Relations, Mabe Canada Inc.

Suite 310, 1 Factory Lane

Moncton, N.B. E1C 9M3

GE AEW05LXB - Real Life Design Studio In the U.S.A.: GEAppliances.com - 1

Parts and Accessories In the U.S.A.: GEAppliances.com

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. GE does not support any servicing of the air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.

Customers in Canada should consult the yellow pages for the nearest Mabe service center, or call 1.800.561.3344.

GE AEW05LXB - Parts and Accessories In the U.S.A.: GEAppliances.com - 1

Contact Us In the U.S.A.: GEAppliances.com

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations

GE Appliances, Appliance Park

Louisville, KY 40225

In Canada: www.GEAppliances.ca, or write to: Director, Consumer Relations, Mabe Canada Inc.

Suite 310, 1 Factory Lane

Moncton, N.B. E1C 9M3

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : GE

Model : AEW05LXB

Category : Washing machine