USER MANUAL AKQ06LA GE

Safety Instructions .....2, 3

Operating Instructions

Control Knob Models .....6, 7

Touch Pad Models .....4, 5

Care and Cleaning

Air Filter 8

Grille and Case ....8

Outdoor Coils .....8

Installation Instructions .9-17

Troubleshooting Tips ...19, 20

Normal Operating Sounds . . .20

Consumer Support

Consumer Support .....24

Product Registration .....21, 22

Warranty .....23

Write the model and serial numbers here:

Model #

Serial #

Find these numbers on a label on the side of the air conditioner.

Owner's Manual and Installation Instructions
AKL05
AKN05
AKQ05
AKS05
AKV05
AKL06
AKN06
AKQ06
AKV06

GE AKQ06LA - Consumer Support - 1

natural_image Stylized white logo design with a circular swirl pattern, no text or symbols present.

49-7452-1 12-02 JR

IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.

⚠ WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

GE AKQ06LA - ⚠ WARNING! - 1

SAFETY PRECAUTIONS

Use this appliance only for its intended purpose as described in this Owner's Manual.
This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
■ Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Repair or replace immediately all electric service cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

■ Turn the mode control to OFF and unplug your air conditioner before making any repairs or cleaning.
NOTE: We strongly recommend that any servicing be performed by a qualified individual.
For your safety...do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

GE AKQ06LA - SAFETY PRECAUTIONS - 1

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

GE AKQ06LA - HOW TO CONNECT ELECTRICITY - 1

⚠ WARNING!

USE OF EXTENSION CORDS—115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.

However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.

CAUTION:

DO NOT use an extension cord with any of the 230/208 volt models.

GE AKQ06LA - CAUTION: - 1

USE OF ADAPTER PLUGS—115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.

However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.

The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.

When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.

If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.

Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

GE AKQ06LA - USE OF ADAPTER PLUGS—115-Volt models only - 1

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

About the controls on the air conditioner—models with touch pads.

Features and appearance will vary.

GE AKQ06LA - About the controls on the air conditioner—models with touch pads. - 1

text_image 5 6 TIMER F °F POWER 1 HIGH MEO TEMP 4 7 3 MODE COOL FAN Cool on Fan on High fan on Medium fan on Low fan on

Air Conditioner Controls

GE AKQ06LA - About the controls on the air conditioner—models with touch pads. - 2

text_image TEMP POWER TIMER MODE FAN ② ③ ① ④

Remote Control

GE AKQ06LA - About the controls on the air conditioner—models with touch pads. - 3

Controls

GE AKQ06LA - Controls - 1

ON/OFF Pad

Turns air conditioner on and off.

GE AKQ06LA - ON/OFF Pad - 1

MODE

Use to set the air conditioner to COOL or FAN mode.

GE AKQ06LA - MODE - 1

Increase ▲/Decrease ▼ Pads

Use to set temperature when in COOL mode.

GE AKQ06LA - Increase ▲/Decrease ▼ Pads - 1

FAN Pad

Use to set the fan speed to LOW, MED or HIGH.

GE AKQ06LA - FAN Pad - 1

TIMER Pad

ON—When the air conditioner is off, it can be set to automatically turn on in 1 to 12 hours at its previous setting. Each touch will set the timer in hours.

OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 12 hours. Each touch will set the timer in hours.

To cancel the timer, press the TIMER pad until the display time disappears.

NOTE: All timer settings are automatically cancelled if the unit is turned on or off after setting the timer.

GE AKQ06LA - TIMER Pad - 1

Display

Shows the room temperature, set temperature or the time remaining on the timer. After setting the controls, the display will change to show the room temperature. To recall the set temperature to the display, press the Increase ▲ / Decrease ▼ pad once. To recall the time remaining on the timer, if it was set, press the TIMER pad once.

Display Codes

E1—Automatic filter clean reminder. Turn the air conditioner OFF and unplug it. NOTE: The air conditioner must be unplugged for the automatic filter clean timer to reset. Clean the filter. See the Care and Cleaning section. After cleaning, replace the filter and plug the air conditioner back in. Er—Room temperature sensor failure. Call for service.

GE AKQ06LA - Display Codes - 1

Remote Control Signal Receiver

Remote Control

To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.
■ The remote control signal has a range of up to 21 feet.

■ Make sure nothing is between the air conditioner and the remote control that could block the signal.
■ Make sure batteries are fresh and installed correctly as indicated on the remote control.

When the air conditioner is turned on, it will automatically start in the setting last used, except the timer will be cancelled if it was set.

Lights in the display or beside the touch pads on the air conditioner control panel indicate the selected settings.

COOL Mode

Use the COOL mode with HIGH, MED or LOW fan for cooling. Use the Increase ▲ / Decrease ▼ pads to set the desired temperature between 60°F and 90°F in 2°F increments (or between 16°C and 31°C in 1°C increments if the control has been set to use Celsius).

A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling—Select the COOL mode and HIGH or MED fan with a middle set temperature.

For Maximum Cooling—Select the COOL mode and HIGH fan with a lower set temperature.

For Quieter & Nighttime Cooling—Select the COOL mode and LOW fan with a middle set temperature.

NOTE: If you switch from a COOL setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a COOL setting.

FAN Mode Fahrenheit or Celsius

Use the FAN at HIGH, MED or LOW to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a temperature setting will not be displayed.

Your control is set to use and display Fahrenheit temperature selections, but you may change it to use and display Celsius selections.

Press and hold the Increase ▲ / Decrease ▼ pads at the same time to switch to °C or °F as desired.

Vent Control

The vent control is located on the inside of the air louvers at the bottom of the vent.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

Vent control lever

GE AKQ06LA - Vent Control - 1

natural_image Diagram of a vertical panel with horizontal bars and a curved arrow pointing to the bottom section (no text or symbols)

To open the vent.

GE AKQ06LA - Vent Control - 2

text_image Vent control lever

To close the vent.

Air Direction

Up and Down

Fingertip pressure on the horizontal louvers adjusts the air direction up or down.

GE AKQ06LA - Up and Down - 1

natural_image Line drawing of a microwave oven with a hand pointing to the right side (no text or symbols)

Side-to-Side

The side-to-side air direction is adjusted by moving the air direction lever to the left or right.

GE AKQ06LA - Side-to-Side - 1

text_image Air direction lever

About the controls on the air conditioner—models with control knobs.

Features and appearance will vary.

GE AKQ06LA - About the controls on the air conditioner—models with control knobs. - 1

text_image OFF HIGH COOL HIGH FAN MED COOL LOW FAN LOW COOL

GE AKQ06LA - About the controls on the air conditioner—models with control knobs. - 2

text_image OFF FANCOOL

1 MODE CONTROLS

Your model will have one of the above type controls.

GE AKQ06LA - MODE CONTROLS - 1

text_image 5 6 7 4 8 3 9 2 10 11 COOLEST

2 TEMP CONTROL (on some models)

GE AKQ06LA - TEMP CONTROL (on some models) - 1

Controls

GE AKQ06LA - Controls - 1

Mode Controls

HIGH COOL, MED COOL and LOW COOL provide cooling with different fan speeds.

COOL provides cooling with a fixed fan speed.

LOW FAN, HIGH FAN or FAN provides air circulation and filtering without cooling.

NOTE: If you move the switch from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.

Cooling Descriptions

For Normal Cooling—Select HIGH COOL or MED COOL with the temp control at midpoint.

For Maximum Cooling—Select HIGH COOL with the temp control at the highest number available on your knob.

For Quieter and Nighttime Cooling—Select LOW COOL with the temp control at midpoint.

GE AKQ06LA - Cooling Descriptions - 1

Temp Controls (on some models)

The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

Additional controls and important information.

Vent Control

The vent control is located on the inside of the air louvers at the bottom of the vent.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

Vent control lever

GE AKQ06LA - Vent Control - 1

text_image Vent control lever

To open the vent. To close the vent.

Air Direction—Up and Down

Fingertip pressure on the horizontal louvers adjusts the air direction up or down.

GE AKQ06LA - Air Direction—Up and Down - 1

natural_image Line drawing of a microwave oven with a hand pointing to the front panel (no text or symbols)

Air Direction—Side-to-Side (on some models)

The side-to-side air direction is adjusted by moving the air direction lever to the left or right.

GE AKQ06LA - Air Direction—Side-to-Side (on some models) - 1

text_image Air direction lever

Care and cleaning of the air conditioner.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam cleaned, a service available through your GE service outlet.

GE AKQ06LA - Outdoor Coils - 1

natural_image Simple line drawing of a cabinet or enclosure with vertical bars, no text or symbols present

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

E1 in the display (on models with touch pads) is an automatic filter clean reminder. Turn the air conditioner OFF and unplug it.

NOTE: The air conditioner must be unplugged for the automatic filter clean timer to reset.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.

NOTE: DO NOT rinse, or put the filter in an automatic dishwasher.

CAUTION:

conditioner without a filter because dirt and lint will clog it and reduce performance.

To remove:

1 Pull to unlatch the lower corners of the inlet grille and lift it up and off.

GE AKQ06LA - To remove: - 1

natural_image Diagram of a computer rack with ventilation grilles and heat exchangers (no text or labels)

2 Using the tab, pull up slightly on the filter to release it and pull it down to remove.

GE AKQ06LA - To remove: - 2

natural_image Illustration of a server rack with a hand inserting a cable (no text or symbols visible)

Preparing to install the air conditioner.

Read these instructions completely and carefully.

GE AKQ06LA - Preparing to install the air conditioner. - 1

Before You Begin

NOTE TO INSTALLER: Leave these instructions with the air conditioner after installation is completed.

NOTE TO CONSUMER: Keep this Owner's Manual and Installation Instructions for future use.

IMPORTANT NOTES:

For personal safety, this air conditioner must be properly grounded.

It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.

Follow National Electrical Codes (NEC) and/or local codes and ordinances.

CAUTION:

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

GE AKQ06LA - CAUTION: - 1

Electrical Requirements

GE AKQ06LA - Electrical Requirements - 1

Some models require 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

GE AKQ06LA - Electrical Requirements - 2

Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

GE AKQ06LA - Electrical Requirements - 3

Tools You Will Need

Phillips-head screwdriver
■Adjustable wrench
■ Ruler or tape measure
Drill

Scissors or knife
Pencil
Level

Window installation instructions.

Parts Included

GE AKQ06LA - Window installation instructions. - 1

text_image Left accordion panel frame Foam top window gasket Window sash seal Top mounting rail seal strip Air conditioner case Top mounting rail Left accordion panel Bottom mounting rail Right accordion panel frame Support bracket (2) Right accordion panel Locking bar (2) Type A (7) Type B (11) Type C (4) Accordion panel clamp (2) Window locking bracket Leveling bolt (2) Nut (2)

Read completely, then follow step-by-step.

1

Window Requirements

These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
All supporting parts must be secured to firm wood, masonry or metal.
The electrical outlet must be within reach of the power cord.

GE AKQ06LA - Window Requirements - 1

text_image 14" min. 22" to 35½" (With accordion panels) 17½" min. (Without accordion panels)

2

Storm Window Requirements

A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.

GE AKQ06LA - Storm Window Requirements - 1

text_image 1/2" higher than frame Storm window frame Wood Stool

WOOD PIECES—

WIDTH: 2"

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2" higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

3

Remove the Air Conditioner From the Case

A Remove the screw from each side of the case. Keep them in a safe location.

GE AKQ06LA - Remove the Air Conditioner From the Case - 1

natural_image Line drawing of a portable electronic device with ventilation grilles and ports (no text or symbols)

B Pull to unlatch the lower corners of the inlet grille and lift it up and off.

GE AKQ06LA - Remove the Air Conditioner From the Case - 2

natural_image Diagram of a box with a grating and airflow arrows, no text or symbols present

C Using the tab, pull up slightly on the filter to release it and pull it down to remove.

GE AKQ06LA - Remove the Air Conditioner From the Case - 3

natural_image Illustration of a server rack with grid panels and cables (no text or symbols)

D Remove the three grille frame screws.

GE AKQ06LA - Remove the Air Conditioner From the Case - 4

text_image Grille frame screws

E Grasp the lower corners of the grill frame while pressing in on the case sides with your finger tips. Pull out to release and lift it up.

NOTE: Do not pull the bottom edge toward you more than 3" or you may damage the tabs of the grille.

GE AKQ06LA - Remove the Air Conditioner From the Case - 5

natural_image Illustration of hands operating a ventilation grille with arrows indicating airflow direction (no text or symbols)

F Remove the screw securing the ground wire to the left side of the face of the unit.

GE AKQ06LA - Remove the Air Conditioner From the Case - 6

text_image Ground wire Screw

G Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case.

GE AKQ06LA - Remove the Air Conditioner From the Case - 7

natural_image Diagram of a computer tower with heat exchanger and cooling unit (no text or symbols)

4

Remove the Shipping Pad

Remove and discard the shipping pad next to the compressor.

GE AKQ06LA - Remove the Shipping Pad - 1

text_image Remove and discard shipping pad

5

Install the Mounting Rails onto the Case

A Remove the backing from the top mounting rail scal strip and attach it to the bottom of the top mounting rail.

B Attach the top mounting rail onto the top of the case with 5 Type A screws.

C Attach the bottom mounting rail to the bottom of the case from the inside, using 2 Type A screws in the back holes of the bottom rail sides.

GE AKQ06LA - Install the Mounting Rails onto the Case - 1

natural_image Technical line drawing of a mechanical component with a flat beam and tapered end (no text or symbols)

GE AKQ06LA - Install the Mounting Rails onto the Case - 2

text_image Type A screws Type A screw Type A screws Type A screws

Window installation instructions.

6

Install the Side Accordion Panels

A Insert the notch on the wider side of one shutter into the groove on the left front side of the case.

GE AKQ06LA - Install the Side Accordion Panels - 1

text_image Shutter Notch

Slide the shutter all the way down into the groove.

GE AKQ06LA - Install the Side Accordion Panels - 2

natural_image Technical line drawing of a mechanical assembly with a downward arrow indicating force or motion (no text or symbols)

B Slide the left accordion panel into the top and bottom mounting rails.

GE AKQ06LA - Install the Side Accordion Panels - 3

natural_image Diagram of a door frame with an arrow indicating direction (no text or symbols)

C Pull the shutter all the way out until the notch on the outside edge of the shutter is visible through the hole in the top corner of the frame. Insert the notch on the shutter into the groove on the locking bar and slide the bar all the way down to secure the shutter.

GE AKQ06LA - Install the Side Accordion Panels - 4

text_image Notch Locking bar

D Repeat steps A–C for the right side accordion panel.

7

Prepare the Window

Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash.

GE AKQ06LA - Prepare the Window - 1

text_image Window sash seal

8

Install the Case in the Window

A Carefully position the case in the window so that the bottom mounting rail is nested against the window stool.
B Center the case and lower the window behind the top mounting rail.

GE AKQ06LA - Install the Case in the Window - 1

natural_image Line drawing of a cabinet or enclosure structure with no visible text or symbols

C Secure the bottom mounting rail of the case to the window stool using 4 Type B screws.

GE AKQ06LA - Install the Case in the Window - 2

text_image Type B screws

GE AKQ06LA - Install the Case in the Window - 3

text_image D Loosely thread a leveling bolt into a support bracket. Support bracket Leveling bolt

E Position the support brackets near the outermost point on the sill. From inside the case, attach the support bracket to the case bottom flange using 2 Type C screws.

GE AKQ06LA - Install the Case in the Window - 4

text_image Type C screws Support bracket

F Repeat steps D and E to install the second support on the other side of the case.
G Adjust the leveling bolts against the sill so that the supports had a slight tilt to the outside. Use a level; about 1/2 bubble will be the correct slant to the outside. After leveling is done, tighten the leveling bolt nut.

NOTE: Use a steel washer between the leveling bolts and the sill if the sill is weak.

GE AKQ06LA - Install the Case in the Window - 5

text_image -1/2 bubble slant to outside Leveling bolt

H Extend the left and right accordion panels to the vertical window sashes. Drill 1/8" pilot holes and attach the top corners with 2 Type B screws. Use an accordion panel clamp on each lower corner to trap the panels. Drill 1/8" pilot holes and attach the panel clamps with 2 Type B screws.

NOTE: Seal any openings around the case or accordion panels with sealer or foam gaskets.

GE AKQ06LA - Install the Case in the Window - 6

text_image Top mounting rail Type B screw Type B screw Panel clamp and Type B screw Panel clamp and Type B screw

9

Secure the Case in the Window and Install the Foam Top Window Gasket

A Drill a 1/8" pilot hole and attach the top mounting rail to the sash with a Type B screw.

GE AKQ06LA - Secure the Case in the Window and Install the Foam Top Window Gasket - 1

text_image Type B screw Top mounting rail

B Cut the foam top window gasket to the window width.

C Stuff the foam between the glass and the window to prevent air and insects from getting into the room.

GE AKQ06LA - Secure the Case in the Window and Install the Foam Top Window Gasket - 2

natural_image Line drawing of a hand holding a knife above a window with liquid (no text or symbols)

D Attach the window locking bracket with 2 Type B screws.

GE AKQ06LA - Secure the Case in the Window and Install the Foam Top Window Gasket - 3

natural_image Line drawing of a screwdriver inserted into a bracket with a screw hole (no text or symbols)

10

Install the Air Conditioner in the Case

A Slide the air conditioner into the case. Do not push on the controls or the finned coils. Make sure the air conditioner is firmly seated.

GE AKQ06LA - Install the Air Conditioner in the Case - 1

natural_image Line drawing of a wall-mounted air conditioner unit with cooling fins and a front panel (no text or symbols)

B Replace the two screws removed earlier, one on each side of the case.

GE AKQ06LA - Install the Air Conditioner in the Case - 2

natural_image Isometric line drawing of a rectangular electronic device with internal grid structure (no text or symbols)

C IMPORTANT! Reconnect the ground wire to the left side of the face of the unit.

GE AKQ06LA - Install the Air Conditioner in the Case - 3

text_image Ground wire Screw

D Attach the front grille frame to the case by inserting the tabs on the grille frame into the slots on the front top of the case. Push the grille frame in until it snaps into place around the power cord on the right side.

GE AKQ06LA - Install the Air Conditioner in the Case - 4

text_image the levers carefully with the grille frame push it in.

E Secure the front grille frame to the case by replacing the screws removed earlier.

GE AKQ06LA - Install the Air Conditioner in the Case - 5

natural_image Line drawing of a computer oven with a hand inserting a component (no text or symbols)

F Install the filter. Hook the inlet grille in the frame and close it. Connect power.

Consumer SupportTroubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions

Notes.

GE AKQ06LA - Install the Air Conditioner in the Case - 6

Troubleshooting Tips.

Save time and money! Review the chart below first and you may not need to call for service.

Problem Possible Causes What To Do
Air conditioner does not start is unplugged.The air conditioner into the outlet.Make sure the air conditioner plug is pushed completely
The fuse is blown/circuit breaker is tripped. the fuse or reset the breaker.Check the house fuse/circuit breaker box and replace the breaker.
Power failure.On models with control knobs, if a power failure occurs, turn the air conditioner OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
Air conditioner has stopped runningPower interruption or power failure occurred.On models with touch pads, when the power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload. Press the POWER pad and reset the controls to the desired settings.
Air conditioner does not cool as it shouldAirflow is restricted.Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner.
The temp control may not be set correctly.On models with touch pads: in COOL mode, press the Decrease ▼ pad.On models with a temperature control knob, turn the temperature knob to a higher number.
The air filter is dirty.Clean the filter at least every 30 days.See the Operating Instructions section.
The room may have been hot.When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cold air is escaping.Check for open furnace floor registers and cold air returns.Set the air conditioner's vent to the closed position.
Cooling coils have iced up.See “Air conditioner freezing up” below.
Air conditioner freezing upIce blocks the air flow and stops the air conditioner from cooling the room.On models with a temperature control knob, set the mode control at HIGH FAN or HIGH COOL with the temp at 1 or 2.On models with touch pads, set the controls at HIGH FAN or HIGH COOL and set the thermostat to a higher temperature.
The remote control is not workingThe batteries are inserted incorrectly.Check the position of the batteries. They should be inserted in the opposite (+) and (-) direction.
The batteries may be dead.Replace the batteries.
Water drips outsideHot and humid weather.This is normal.
Water drips indoorsThe air conditioner is not tilted to the outside.For proper water disposal, make sure the air conditioner slants slightly from the case front to the rear.
Water collects in base panMoisture removed from air and drains into base pan.This is normal for a short period in areas with little humidity; normal for a longer period in very humid areas.

Before you call for service...

GE AKQ06LA - Before you call for service... - 1

Troubleshooting Tips.

Problem Possible Causes What To Do

Temperature settings in the display can only be set between 16 and 31The control has been set to use Celsius.• Press and hold the Increase ▲ / Decrease ▼ pads at the same time to switch to Fahrenheit settings.
“E1” appears in the display NOTE:Filter needs to be cleaned.• Turn the air conditioner OFF and unplug it. automatic filter clean timer to reset. Clean the filter. See the Care and Cleaning section. After cleaning, replace the filter and plug the air conditioner back in.
“Ed” appears in the displayFrost protect automatically activated.• Turn the air conditioner off. Wait at least 3 minutes and turn the air conditioner back on. If the code reappears, call for service.
“En” appears in the displayPipe temperature sensor failure.• Call for service.
“Er” appears in the displayRoom temperature sensor failure.• Call for service.

Normal Operating Sounds

You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
■ You may hear the thermostat click when the compressor cycles on and off.

Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
■ The fan may run even when the compressor does not.

GE Service Protection Plus™

GE, a name recognized worldwide for quality and dependability, offers you Service Protection Plus™—comprehensive protection on all your appliances—No Matter What Brand!

Benefits Include:

  • Backed by GE
  • All brands covered
    • Unlimited service calls
  • All parts and labor costs included
    • No out-of-pocket expenses
    • No hidden deductibles
    • One 800 number to call

We'll Cover Any Appliance. Anywhere. Anytime.\*

You will be completely satisfied with our service protection or you may request your money back on the remaining value of your contract. No questions asked. It's that simple.

Protect your refrigerator, dishwasher, washer and dryer, range, TV, VCR and much more—any brand! Plus there's no extra charge for emergency service and low monthly financing is available. Even icemaker coverage and food spoilage protection is offered. You can rest easy, knowing that all your valuable household products are protected against expensive repairs.

Place your confidence in GE and call us in the U.S. toll-free at 800.626.2224 for more information.

*All brands covered, up to 20 years old, in the continental U.S.

GE AKQ06LA - We'll Cover Any Appliance. Anywhere. Anytime.\* - 1

Cut here

Please place in envelope and mail to:

General Electric Company

Warranty Registration Department

P.O. Box 32150

Louisville, KY 40232-2150

Consumer Product Ownership Registration

Dear Customer:

Thank you for purchasing our product and thank you for placing your confidence in us.

We are proud to have you as a customer!

Follow these three steps to protect your new appliance investment:

1

Complete and mail your Consumer Product Ownership Registration today. Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification.

2

After mailing the registration below, store this document in a safe place. It contains information you will need should you require service. Our service number is 800.GE.CARES (800.432.2737).

3

Read your Owner's Manual carefully. It will help you operate your new appliance properly.

Model Number Serial Number

GE AKQ06LA - Model Number Serial Number - 1

natural_image Two identical horizontal lines with tick marks, no text or symbols present

Important: If you did not get a registration card with your product, detach and return the form below to ensure that your product is registered, or register online at www.GEAppliances.com.

GE AKQ06LA - Important: If you did not get a registration card with your product, detach and return the form below to ensure that your product is registered, or register online at www.GEAppliances.com. - 1

Consumer Product Ownership Registration

GE AKQ06LA - Consumer Product Ownership Registration - 1

Model Number Serial Number

GE AKQ06LA - Model Number Serial Number - 1

natural_image Two identical horizontal lines with tick marks, no text or symbols present

GE AKQ06LA - Model Number Serial Number - 2

text_image Mr. □ Ms. □ Mrs. □ Miss □ First Name Last Name Street Address Apt. # F-mail Address* City State Zip Code Date Placed In Use Month Day Year Phone Number -

GE AKQ06LA - Model Number Serial Number - 3

GE AKQ06LA - Model Number Serial Number - 4

* Please provide your e-mail address to receive, via e-mail, discounts, special offers and other important communications from GE Appliances (GEA).

□ Check here if you do not want to receive communications from GFA's carefully selected partners.

GE Appliances

GE Consumer Products General Electric Company Louisville, Kentucky www.GEAppliances.com

Air Conditioner Warranty.

GE AKQ06LA - Air Conditioner Warranty. - 1

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, 24 hours a day, visit us at www.GEAppliances.com, or call 800.GE.CARES (800.432.2737).

Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty.

For The Period Of: We Will Replace:

One YearFrom the date of the original purchase serviceAny part of the air conditioner which fails due to a defect in materials or workmanship.During this full one-year warranty, we will also provide, free of charge, all labor and in-home to replace the defective part.
Five YearsFrom the date of the original purchaseAny part of the sealed refrigerating system (the compressor, condenser, evaporator and all connecting tubing) which fails due to a defect in materials or workmanship. During this four-year additional warranty, we will also provide, free of charge, all labor and in-home service to replace the defective part.

What Is Not Covered:

■ Service trips to your home to teach you how to use the product.
Improper installation, delivery or maintenance. If you have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician.

Replacement of house fuses or resetting of circuit breakers.
Failure due to corrosion on models not corrosion-protected.
Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
■Incidental or consequential damage caused by possible defects with this air conditioner.
Damage after delivery.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state's Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

GE AKQ06LA - What Is Not Covered: - 1

GE Appliances Website www.GEAppliances.com

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner's Manuals, order parts, catalogs, or even schedule service on-line. You can also "Ask Our Team of Experts" your questions, and so much more...

GE AKQ06LA - GE Appliances Website www.GEAppliances.com - 1

Schedule Service www.GEAppliances.com

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience 24 hours any day of the year! Or call 800.GE.CARES (800.432.2737) during normal business hours.

GE AKQ06LA - Schedule Service www.GEAppliances.com - 1

Real Life Design Studio www.GEAppliances.com

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE's Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

GE AKQ06LA - Real Life Design Studio www.GEAppliances.com - 1

Extended Warranties www.GEAppliances.com

Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800.626.2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

GE AKQ06LA - Extended Warranties www.GEAppliances.com - 1

Parts and Accessories www.GEAppliances.com

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

GE AKQ06LA - Parts and Accessories www.GEAppliances.com - 1

Contact Us www.GEAppliances.com

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations GE Appliances, Appliance Park Louisville, KY 40225

GE AKQ06LA - Contact Us www.GEAppliances.com - 1

Register Your Appliance www.GEAppliances.com

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material.

natural_image Abstract decorative swirl design with no text or symbols

49-7452-1 12-02 JR

natural_image Line drawing of a portable radio with a hand pointing to the right side (no text or symbols)

De lado a lado

natural_image Diagram of a vertical ladder structure with a curved arrow indicating direction (no text or symbols)
natural_image Line drawing of a multi-tiered storage unit or rack with an arrow pointing to the front panel (no text or symbols present)
natural_image Line drawing of a microwave oven with a hand pointing to the front panel (no text or symbols)
natural_image Technical line drawing of a car air vent with a handle and side panel (no text or symbols)
natural_image Simple line drawing of a cabinet or enclosure with vertical bars, no text or symbols present

Filtro de aire

natural_image Diagram of a rectangular device with internal heat exchanger and cooling fins (no text or symbols)
natural_image Line drawing of a server rack unit with grid panels and ventilation slots (no text or symbols)
natural_image Line drawing of a portable air conditioner unit with ventilation grilles and control buttons (no text or symbols)
natural_image Diagram of a rectangular device with a slatted top and side panel, showing airflow or heat flow direction (no text or symbols)
natural_image Illustration of a rectangular electronic device with grid panels and a keypad, connected by a hand (no text or symbols)
natural_image Illustration of hands holding a fan or vent with arrows indicating airflow or movement (no text or symbols)
natural_image Line drawing of a computer tower with hands installing or adjusting the panel (no text or symbols present)

4

natural_image Technical line drawing of a mechanical component with layered structure (no text or symbols)

GE AKQ06LA - 4 - 1

natural_image Technical line drawing of a structural frame with a downward arrow indicating compression or clearance (no text or symbols)
natural_image Diagram of a door frame with an arrow indicating direction, no text or symbols present
natural_image Line drawing of a cabinet or enclosure structure with no visible text or symbols
natural_image Line drawing of a hand holding a knife above a window with liquid (no text or symbols)
natural_image Line drawing of a screwdriver inserted into a bracket with a screwdriver inserted (no text or symbols)

10

natural_image Line drawing of a wall-mounted air conditioner unit with cooling fins and a front panel (no text or symbols)
natural_image Line drawing of a rectangular electronic device with internal grid structure (no text or symbols)
natural_image Line drawing of a computer oven with ventilation grilles and a hand inserting a cable (no text or symbols)

Garante: General Electric Company. Louisville, KY 40225

GE AKQ06LA - 10 - 1

General Manager, Customer Relations

GE Appliances, Appliance Park

Louisville, KY 40225

GE AKQ06LA - 10 - 2

Registre su electrodoméstico www.GEAppliances.com

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : GE

Model : AKQ06LA

Category : Air-conditioner