ADE MWSK-240717 - Scale

MWSK-240717 - Scale ADE - Free user manual and instructions

Find the device manual for free MWSK-240717 ADE in PDF.

📄 12 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice ADE MWSK-240717 - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
BrandADE
ModelMWSK-240717
Product TypeMobile Weighing Station (Non-automatic weighing instrument)
Trolley MaterialStainless steel
Weighing Platform MaterialStainless steel
Overall Dimensions695 × 563 × 1150 mm
Net Weight23 kg
Castors4 swivel castors, 2 with locking brakes
Display UnitFF type, permanently connected
Connection CablePermanently attached to scale
Leveling SystemLeveling feet with bubble level
Intended UseIndustrial non-automatic weighing; not for transport of goods
CalibrationRequired for legal-for-trade; refer to display unit manual
CleaningDisconnect power; use soft damp cloth; pH neutral detergents (7-8); avoid liquids inside
StorageKeep original packaging; disconnect cables; store in dry environment
Warranty1 year from date of purchase (receipt required)
ConformityCE, EMC Directive 2014/30/EU, LVD 2014/35/EU, RoHS 2011/65/EU
SafetyRead manual; avoid tripping/strangulation hazards; use on level dry surface; keep away from drafts and extreme temperatures
DisposalDo not dispose with household waste; recycle as WEEE; remove batteries if any

Frequently Asked Questions - MWSK-240717 ADE

What is the maximum weight capacity of the MWSK-240717?
The maximum load depends on the connected display unit. Refer to the display unit's manual for its specifications. Do not exceed the max weight indicated on the scale's nameplate.
Can I move the scale while it is weighing?
No, the carriage must remain stationary during weighing. Any weighing performed with the carriage in motion is not permissible.
How do I level the scale?
Use the leveling feet to adjust the weighing platform until the air bubble of the bubble level is centered within the black outline. Check levelness each time you change location.
How should I clean the scale?
Unplug the appliance from power before cleaning. Use a soft, slightly damp cloth with a detergent of pH 7-8. Never use concentrated acids, alkalis, solvents, or pure alcohol. Avoid getting liquid inside the appliance.
What is the warranty period?
ADE provides a 1-year warranty from the date of purchase (receipt required) for defects in material and workmanship. It does not cover moving parts like batteries, cables, or damage from misuse.
Is the scale legal for trade?
Yes, if it is calibrated according to the display unit's operating instructions. The weighing station must be calibrated to be suitable for legal-for-trade applications.
What should I do if the scale shows an error?
Refer to the display unit's operating manual for error messages and troubleshooting. If problems persist, contact the authorized service center. Do not attempt to open or repair the scale yourself.
Can I use the scale outdoors?
The scale must only be used within the permissible ambient conditions specified for the display unit. Avoid extreme temperatures, direct sunlight, drafts, and moisture. It is intended for indoor use on a dry, level surface.
How should I transport the scale?
Keep all original packing materials. Before transport, disconnect all cables and switch off the scale. Use the original packaging to avoid transport-related damage.
What materials is the scale made of?
The trolley and weighing platform are made of stainless steel. The display unit housing material may vary; refer to the display unit manual.

User questions about MWSK-240717 ADE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Scale in PDF format for free! Find your manual MWSK-240717 - ADE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MWSK-240717 by ADE.

USER MANUAL MWSK-240717 ADE

OPERATING INSTRUCTIONS

ADE

Electronic industrial scales

ADE MWSK-240717 - ADE - 1

natural_image Exterior view of a metal scale balance with wheels and a digital display (no text or symbols visible)

Illustration shows the carriage with an FF display unit

Mobile weighing station MWSK

MWSK-240717-Rev001-UM-en

ADE MWSK-240717 - Mobile weighing station MWSK - 1

1. Contents

  1. Contents......2
  2. Intended use.... 3
  3. Safety instructions .... 3
  4. Scope of Supply 4
  5. Overview 5
  6. Setup and alignment.... 5

Setting up and aligning the mobile weighing station 5

Installing and connecting the display unit ....5

Starting up the weighing station....6

  1. Cleaning and care 6

Cleaning....6

Faults and error messages....6

Storage and transportation conditions....6

Disposal....6

Warranty 7

  1. Technical Data....7

  2. Declaration of Conformity 8

2. Intended use

ADE MWSK-240717 - Intended use - 1

This symbol means: "Observe operating instructions." For accurate results, read these operating instructions carefully and observe the information contained therein. Keep these operating instructions handy for future reference.

Your ADE mobile weighing station is a quality product designed for use as a non-automatic weighing instrument.

Never exceed the maximum weight (Max) indicated on the scale's nameplate. For accurate results, read the installation and operating instructions carefully and observe the information contained therein. The scale may only be operated and maintained by qualified personnel.

The weighing station must be calibrated to be suitable for legal-for-trade applications. For this purpose, comply with the specifications in the operating manual for the display unit.

The appliance must only be used for its intended purpose. Any use of the device other than that described in the section “Intended use” shall be deemed to be improper use. The manufacturer assumes no liability whatsoever for any damage to property or personal injury resulting from improper use of the appliance.

The manufacturer's warranty shall be null and void if any components other than the original parts supplied by the manufacturer are used.

ADE MWSK-240717 - Intended use - 2

This weighing station is not suitable for the transport of goods or objects! Any modification of the appliance requires the prior written consent of the manufacturer.

3. Safety instructions

It is essential that you read, understand, and follow all instructions in this manual and other instructions pertaining to the weighing station and its components, as well as country-specific installation standards, applicable safety regulations, and accident prevention regulations.

  • Exercise care when using the scale and remember that it is a high-precision instrument.
  • The scale may only be operated and maintained by authorized qualified personnel. Improper use may cause personal injury or damage to the weighing station.
  • Before you start using the appliance, ensure that the power rating and current type specified on the nameplate of the connected display unit match the power rating and current type of your local grid.

- The cables must be laid so that they do not pose a tripping hazard.

- The cables must be laid so that they do not pose a risk of strangulation.

- Never operate the appliance outside the permissible ambient conditions.

- The scale must not be exposed to extreme temperatures caused by adjacent equipment or sunlight.

- Always ensure constant ambient temperatures when using the scale and avoid using it in a draft, as the measurement results may otherwise be inaccurate.

- The scale should be placed as far away as possible from other equipment or sources of electromagnetic or other interference (e.g., powerful motors and portable and mobile RF communications equipment), as these can affect the measurement results.

- Make sure to use only approved accessories and peripheral devices.

- Always unplug the appliance from the power outlet before cleaning it.

  • Never immerse the appliance in water or any other liquids.
  • If you have any problems during the installation, operation, or maintenance of the appliance, contact the authorized service center. Never attempt to open or repair the appliance single-handedly.
  • Be sure to report any unexpected operations or events to the authorized service center.

DO NOT use the scale:

  • when the power adapter is damaged;
  • when the power adapter does not work;
  • when the battery compartment is warped;
  • after extended storage in a humid environment.
    If any of these occurs, contact the authorized service center.

Always comply with the safety instructions in the operating manual for the display unit!

4. Scope of Supply

Be sure to check the package contents for completeness upon receipt of the scale. Carefully remove the scale and accessories from the package and discard all packing materials.

  • Carriage with the weighing platform
  • Operating instructions for the mobile weighing station
  • Display unit
  • Operating manual for the display unit
  • Additional accessories, if any (if listed in the operating instructions for display purposes)
  • Declaration of conformity based on the serial number (for calibrated scales only)

ADE MWSK-240717 - Scope of Supply - 1

The display unit is permanently connected to the scale with a connection cable. Ensure the cable is not overly kinked or pinched, or it will be damaged.

5. Overview

Labeled diagram of a mechanical scale with numbered parts and a digital display on top

Illustration shows the carriage with an FF display unit

1 Stainless steel trolley with 4 swivel castors, thereof 2 with locking brakes
2 Weighing platform with
3 Display unit

6. Setup and alignment

Setting up and aligning the mobile weighing station

ADE MWSK-240717 - Setting up and aligning the mobile weighing station - 1

The display unit is permanently connected to the scale with a connection cable. Ensure the cable is not overly kinked or pinched, or it will be damaged.

The carriage must remain stationary during the weighing process. Any weighing performed with the carriage in motion is not permissible!

Special precautions concerning EMC must be taken when installing and operating electrical equipment in compliance with these operating instructions!

  • Place the carriage on a level, firm, and dry surface.
  • Place the scale on the carriage so that all four feet touch the bearing surfaces of the carriage. The fixing brackets prevent subsequent slippage of the scale.
  • Now lift off the weighing platform. Use the leveling feet to level the weighing platform. Ensure the air bubble of the bubble level is centered within the black outline.
  • Replace the weighing platform. The weighing station is now ready for use.

ADE MWSK-240717 - Setting up and aligning the mobile weighing station - 2

Be sure to check the levelness of the scale each time you change its location!

ADE MWSK-240717 - Setting up and aligning the mobile weighing station - 3

Installing and connecting the display unit

For this purpose, comply with the specifications in the operating manual for the display unit.

Starting up the weighing station

For this purpose, comply with the specifications in the operating manual for the display unit.

7. Cleaning and care

Cleaning

ADE MWSK-240717 - Cleaning - 1

Unplug the appliance from the power supply before cleaning.

Make sure that no liquid gets inside the appliance!

For this purpose, always comply with the specifications in the operating manual for the display unit.

Use a soft, slightly damp cloth to clean all parts if necessary.

Only use detergents that are suitable and approved for cleaning all parts. Only use products with a pH value of 7-8 for cleaning. Never use concentrated acids, alkalis, solvents, or pure alcohol for cleaning.

Faults and error messages

For this purpose, comply with the specifications in the operating manual for the display unit.

Storage and transportation conditions

Keep all original packing materials and components for the possible return of the scale to avoid transport-related damage that is not covered by the warranty.

Before transporting the scale, disconnect all cables and switch off the scale to avoid damage.

Disposal

ADE MWSK-240717 - Disposal - 1

Waste electrical and electronic equipment must not be disposed of in household waste. Equipment with this marking must not be disposed of in residual waste and must be recycled.

Remove all (rechargeable) batteries, if any, from the appliance and dispose of them properly.

Before disposing of batteries, ensure they are dead or have insulated terminals to avoid short-circuiting!

Warranty

If the product is proven to have failed within 1 year from the date of purchase (receipt required) due to defects in material and workmanship, ADE will repair or replace the product. The warranty does not cover moving parts such as batteries, cables, power adapters, etc. This warranty does not extend to external normal wear and tear or damage caused by accident or misuse. Any warranty and damage claims may only be asserted if original accessories and spare parts of ADE are used. This warranty does not cover the products tampered with by unauthorized personnel.

The warranty agreement shall not affect the customer's statutory rights.

Complaints shall be addressed to the dealer from whom the scale and spare parts have been purchased or who provides the after-sales service.

8. Technical Data

Power supply

According to the display unit specifications

Measuring range

According to the display unit specifications

Maximum load:

According to the display unit specifications

Increment:

According to the display unit specifications

Ambient conditions

Operating temperature:

According to the display unit specifications

Storage and transport temperature:

According to the display unit specifications

Relative humidity:

According to the display unit specifications

Housing

Dimensions:

695 × 563 × 1.150 mm

Weighing surface:

According to the weighing platform specifications

Net weight:

23 kg

Material:

Trolley: Stainless steel

9. Declaration of Conformity

CE

Manufacturer's declaration of conformity

This product was manufactured according to the harmonized European standards. It complies with the provisions of the EC directives listed below:

- EMC Directive 2014/30/EU

– LVD Directive 2014/35/EU

– RoHS Directive 2011/65/EU

in their current version.

This declaration becomes invalid if the scale is converted in a way that has not been approved by us.

Hamburg, July 2024

ADE Germany GmbH

Neuer Höltigbaum 15

22143 Hamburg / Germany

Manufacturer:

ADE Germany GmbH

Neuer Höltigbaum 15

22143 Hamburg / Germany

+49 40 432 776 - 0

+49 40 432 776 - 10

info@ade-germany.de

www.ade-germany.de

Distributor:

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ADE

Model : MWSK-240717

Category : Scale