| Product Type | Infrared Motion Sensor |
| Model | VT-81010 |
| SKU | 23426 |
| Input Voltage | AC 220-240V, 50/60 Hz |
| Rated Load | Max 1200W (600W LED) |
| Power Consumption | Approx. 0.9W |
| Detection Angle | 360° |
| Detection Distance | 8m max (<24°C) |
| Detection Speed | 0.6-1.5 m/s |
| Time Delay | Min 10 sec ±3 sec, Max 15 min ±2 min |
| Ambient Light Setting | 3-2000 LUX (adjustable) |
| Working Temperature | -20°C to +40°C |
| Working Humidity | <93% RH |
| IP Rating | IP20 |
| Installation Height | 1.8-4m |
| Cutout Size | ∅63-66mm |
| Dimensions | ∅76 x 49 mm |
| Warranty | 5 years |
| Compatibility | V-TAC LED range (up to 600W) |
| Installation Environment | Indoor use only |
Frequently Asked Questions - VT-81010 V-TAC
User questions about VT-81010 V-TAC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Motion detector in PDF format for free! Find your manual VT-81010 - V-TAC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. VT-81010 by V-TAC.
USER MANUAL VT-81010 V-TAC
WEEE Number: 80133970
INSTRUCTION MANUAL
INFRARED MOTION SENSOR
TECHNICAL DATA
| MODEL VT-81010 | |
| SKU 23426 | |
| INPUT VOLTAGE AC: 220-240V, 50/60 Hz | |
| RATED LOAD | Max. 1200Wn600W +LED |
| TIME DELAY | Min. 10sec ±3secMax. 15min ±2min |
| DETECTION RANGE | 360° |
| DETECTION DISTANCE | 8m Max (<24°C) |
| DETECTION MOTION SPEED | 0.6-1.5m/s |
| WORKING TEMPERATURE | -20°C to +40°C |
| WORKING HUMIDITY | <93%RH |
| POWER CONSUMPTION | Approx, 0.9W |
| AMBIENT LIGHT <3-2000 LUX (Adjustable) | |

natural_image
White ceiling-mounted LED fixture with blue handle and control knobs, no visible text or symbols on the component itself.COMPATIBLE WITH
V-TAC LED
RANGE (UPTO 600W)
05 YEAR
WARRANTY*
| IP RATING | IP20 |
| INSTALLATION HEIGHT | 1.8-4m |
| CUTOUT SIZE | ∅63-66m |
| DIMENSION | ∅76x49 mm |
INTRODUCTION & WARRANTY
Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any another query, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best. The warranty is valid for 5 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product.

Caution, risk of electric shock.

MULTI-LANGUAGE MANUAL QR CODE
Please scan the QR code to access the manual in multiple languages.

This marking indicates that this product should not be disposed of with other household wastes.

FR
- Please make sure to turn off the power before starting the installation.
- Installation must be performed by a qualified electrician.
- Cover or shied any adjacent live components.
- For indoor use only.
FUNCTION
- Can identify day and night: The consumer can adjust working state in different ambient light. It can work in the daytime and at night when it is adjusted on the "sun" position (max). It can work in the ambient light less than 3LUX when it is adjusted on the "3" position (min). As for the adjustment pattern, please refer to the testing pattern.
- Time-Delay is added continually: When it receives the second induction signals within the first induction, it will restart to time from the moment.

natural_image
Diagram of a showerhead emitting red light rays, with no text or symbols present.Good Sensitivity Poor Sensitivity

natural_image
Diagram of a spray gun emitting red light rays, with an arrow indicating direction (no text or symbols)INSTALLATION ADVICE
As the detector responds to changes in temperature, avoid the following situations:
- Avoid pointing the detector towards objects with highly reflective surfaces, like mirrors etc.
- Avoid mounting the detector near heat sources as heating vents, air conditioners, light etc.
- Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.

natural_image
Diagram of a room with two monitors and a ceiling-mounted device, showing light rays from the screen (no text or symbols)
natural_image
Diagram showing a light bulb inside a 3D cube with diagonal lines, no text or symbols present
natural_image
Diagram showing a potted plant under sunlight with a window and a roof, intersected by diagonal lines (no text or symbols)INSTALLATION
- Switch off the power.
- Unload the transparent cover.
- Connect the power to connection terminal of sensor according to connection-wire diagram.
• Install back the transparent cover into the original location. - Fold the metal spring of the sensor upwards and then put the sensor into the suitable hole or installation box. Releasing the spring, the sensor will be set in this installation position.
• After finishing installing, turn on the power and then test it.

WIRING DIAGRAM

SENSOR INFORMATION


Height of Installation: 1.8-4m DETECTION DISTANCE: Max. 8m
TEST
- Turn the TIME knob anti-clockwise on the minimum (IOS). Turn the LUX knob clockwise on the maximum (sun).
- Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start work. If the sensor receives the

induction signal, the lamp will turn on. While there is no another induction signal any more, the load should stop working within 10 sec ± 3 sec and the lamp would turn off.
- Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, the sensor would not work and the lamp stop working too. If the ambient light is less than 3LUX (darkness), the sensor would work. Under no induction signal condition, the sensor should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to ⚙ (SUN) position, Otherwise the sensor lamp will not work.
TROUBLESHOOTING
• The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
• The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in the instruction.
e. Please check if the moving orientation is correct.
- The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position.
RoHS