IFM PU1760 - Sensor

PU1760 - Sensor IFM - Free user manual and instructions

Find the device manual for free PU1760 IFM in PDF.

📄 7 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice IFM PU1760 - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Electronic Pressure Sensor
Model PU1760
Brand IFM
Application Mobile hydraulic systems, industrial pressure monitoring
Pressure Type Relative pressure
Measuring Range (Final Value) 0..8000 psi
Static Pressure Resistance (Max Permissible) 20000 psi
Bursting Pressure 36250 psi
Output Signal 0.5..4.5 V analogue
Operating Voltage 8..32 V DC
Medium Temperature -40..125°C
Ambient Temperature -40..100°C
Storage Temperature -40..100°C
Process Connection 9/16-18 UNF female thread
Electrical Connection Deutsch DT04 3P connector
Tightening Torque 30..50 Nm (depending on lubrication, seal, and pressure rating)
Shock Resistance 500 g (DIN EN 60068-2-27, 1 ms)
Vibration Resistance 20 g (DIN EN 60068-2-6, 10..2000 Hz)
Pressure Cycles (Min.) 60 million at 1.2 x nominal pressure
Safety Features Overload protection, vacuum resistant, burn hazard warning for high medium temperatures
Compliance Pressure Equipment Directive (PED) for group 2 fluids; designed per sound engineering practice
Special Feature Restrictor in process connection for use in hydraulic systems of mobile machines
Protection Units with measuring range final value 8000 psi: PED Module A compliant

Frequently Asked Questions - PU1760 IFM

What is the measuring range of the IFM PU1760 pressure sensor?
The measuring range final value is 0..8000 psi relative pressure.
What type of output signal does the PU1760 provide?
The PU1760 provides an analogue voltage output of 0.5..4.5 V.
What is the supply voltage range for this sensor?
The operating voltage is 8..32 V DC (SELV/PELV to EN 50178).
What process connection does the PU1760 use?
It uses a 9/16-18 UNF female thread process connection.
Can the PU1760 be used in hydraulic systems of mobile machines?
Yes, it is specifically designed for mobile hydraulic applications and includes a restrictor (0.3 mm equivalent hole) in the process connection to reduce dynamic effects.
What are the temperature limits for the PU1760?
Medium temperature: -40..125°C, ambient temperature: -40..100°C, storage temperature: -40..100°C.
How should the PU1760 be installed?
Insert the sensor into a 9/16-18 UNF process connection and tighten to the recommended torque (30..50 Nm for 8000 psi units). Ensure no pressure is applied during installation or removal.
What safety precautions should be observed?
Do not exceed the maximum permissible pressure (20000 psi) or bursting pressure (36250 psi). Avoid contact with hot surfaces; protect housing from flammable substances. Use only for permissible media and in suitable environmental conditions.
Is the PU1760 vacuum resistant?
Yes, the unit is vacuum resistant.
What is the recommended tightening torque for the PU1760?
For units with a final measuring range of 8000 psi, the recommended tightening torque is 30..50 Nm, depending on lubrication, seal, and pressure rating.

User questions about PU1760 IFM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Sensor in PDF format for free! Find your manual PU1760 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PU1760 by IFM.

USER MANUAL PU1760 IFM

Operating instructions Electronic pressure sensor for mobile applications

PU17xx

UK

80261064 / 00 03 / 2020

IFM PU1760 - 1

natural_image Technical line drawing of a mechanical component with no visible text or symbols

Contents

1 Preliminary note....2
2 Safety instructions .... 2
3 Functions and features .... 3

3.1 Applications ....4
3.2 Use in hydraulic systems of mobile machines....5

4 Functions....5
5 Installation....6
6 Electrical connection....6
7 Technical data and scale drawing....7

1 Preliminary note

Symbols used

▶ Instructions
→ Cross-reference

IFM PU1760 - Symbols used - 1

Important note

Non-compliance can result in malfunction or interference.

IFM PU1760 - Symbols used - 2

Information

Supplementary note.

Warning sign with exclamation mark inside a triangle on yellow background

CAUTION

Warning of personal injury.

Slight reversible injuries may result.

2 Safety instructions

- The device described is a subcomponent for integration into a system.

  • The manufacturer is responsible for the safety of the system.
  • The system manufacturer undertakes to perform a risk assessment and to create a documentation in accordance with legal and normative requirements to be provided to the operator and user of the system. This documentation

must contain all necessary information and safety instructions for the operator, the user and, if applicable, for any service personnel authorised by the manufacturer of the system.

  • Read this document before setting up the product and keep it during the entire service life.
  • The product must be suitable for the corresponding applications and environmental conditions without any restrictions.
  • Only use the product for its intended purpose (→ Functions and features).
  • Only use the product for permissible media (→ Technical data).
  • If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur.
  • The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator.
  • Installation, electrical connection, set-up, programming, configuration, operation and maintenance of the product must be carried out by personnel qualified and authorised for the respective activity.
  • Protect units and cables against damage.

Yellow warning sign with black exclamation mark in triangle

CAUTION

For high medium temperatures, parts of the unit may heat up.

Risk of burns
▶ Do not touch the unit
▶ Protect the housing against contact with flammable substances and unintentional contact.

3 Functions and features

The pressure sensor detects the system pressure and converts it into an analogue output signal.

3.1 Applications

• Type of pressure: relative pressure

Order numberFinal value of the measuring range (nominal pressure)Static pressure resistance (max. permissible pressure)Bursting pressure
psi psi psi
PU1760 0..8000 20000 36250
PU1700 0..5000 14500 24650
PU1701 0..3600 9000 17400
PU1732 0..3000 7250 14500
PU1702 0..1000 2500 13050
PU1743 0..500 1450 11600

IFM PU1760 - Applications - 1

Avoid overload pressure exceeding the specified maximum permissible pressure by taking appropriate measures.

The indicated bursting pressure must not be exceeded.

Even if the bursting pressure is exceeded only for a short time, the unit may be destroyed. ATTENTION: Risk of injury!

IFM PU1760 - Applications - 2

For units with a final value of the measuring range of 8000 psi the limits of the pressure cycles across the lifetime apply ( → 7).

IFM PU1760 - Applications - 3

If the cable length exceeds 30 m or if used outside buildings, there is a risk of overvoltage pulses from external sources. We recommend to use the unit in protected operating environments and to limit overvoltage pulses to max. 500 V.

IFM PU1760 - Applications - 4

Pressure Equipment Directive (PED):

- Units with a final value of the measuring range of 500...5000 psi comply with the Pressure Equipment Directive and are designed and manufactured for group 2 fluids in accordance with the sound engineering practice. Use of group 1 fluids on request!

IFM PU1760 - Applications - 5

Pressure Equipment Directive (PED):

The units with a final value of the measuring range of 8000 psi comply with the Pressure Equipment Directive. They are designed for group 2 fluids and manufactured and tested according to Module A.

Use of group 1 fluids on request!

IFM PU1760 - Applications - 6

The units are vacuum resistant.

3.2 Use in hydraulic systems of mobile machines

Restrictor in the process connection:

In hydraulic systems of mobile machines, highly dynamic effects such as pressure peaks, cavitation etc. may arise depending on the operating conditions. To reduce these effects on the measuring element of the sensor, a diaphragm attachment is integrated into the process connection.

The specific thread pitch of the diaphragm attachment has the effect of a hole of 0.3 mm.

IFM PU1760 - Use in hydraulic systems of mobile machines - 1

Please note:

High viscosity may reduce the response time by some milliseconds. Heavy soiling may affect the functionality.

IFM PU1760 - Use in hydraulic systems of mobile machines - 2

4 Functions

Voltage output 0.5 ... 4.5 V (PU17xx)
IFM PU1760 - Functions - 1

line | MEWMAW P | U [V] | | -------- | ----- | | 0 | 0.5 | | 1 | 4.5 |

P = system pressure
MAW = initial value of the measuring range MEW = final value of the measuring range
In the measuring range, the output signal is between 0.5 and 4.5 V.

5 Installation

IFM PU1760 - Installation - 1

Before installing and removing the unit: Make sure that no pressure is applied to the system.

▶ Insert the unit in a 9/16-18 UNF process connection.
▶ Tighten firmly. Recommended tightening torque:

Final value of the measuring range in psi Tightening torque in Nm
500...5000 25...35
8000 30...50
Depends on lubrication, seal and pressure rating!

6 Electrical connection

IFM PU1760 - Electrical connection - 1

The unit must be connected by a qualified electrician. Voltage supply to EN 50178, SELV, PELV.

▶ Disconnect power.
▶ Connect the unit as follows:

PU17xx (0.5...4.5 V analogue)

Deutsch DT04 3P
IFM PU1760 - Electrical connection - 2IFM PU1760 - Electrical connection - 3
OUT: Analogue output 0.5...4.5 V

7 Technical data and scale drawing

IFM PU1760 - Technical data and scale drawing - 1

Pressure Equipment Directive (PED) stipulates that the following technical data must be provided for units with a final value of the measuring range of 600 bar.

PU1760
Operating voltage [V]8..32 DC
Analogue output0.5..4.5 V
Medium temperature [°C]-40..125
Ambient temperature [°C]-40..100
Storage temperature [°C]-40..100
Pressure cycles (min.) across lifetime60 million for 1.2 x nominal pressure
Shock resistance [g]500 (DIN EN 60068-2-27, 1 ms)
Vibration resistance [g]20 (DIN EN 60068-2-6, 10..2000 Hz)

Further technical data and scale drawing at www.ifm.com.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : IFM

Model : PU1760

Category : Sensor