Notice IFM PX9134 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypePressure Sensor
BrandIFM
ModelPX9134
CategorySensor
Dimensions50 x 30 x 20 mm
Weight0.1 kg
Power Supply24 VDC
Output Signal4-20 mA / IO-Link
Protection ClassIP67
MaterialStainless steel
Operating Temperature-25 to 80 °C
FunctionsPressure measurement, monitoring
MaintenanceClean with dry cloth; avoid solvents
SafetyDo not exceed voltage range; disconnect power before cleaning
Spare PartsConnecting cables, mounting brackets available separately
General InformationIndustrial sensor for automation and process control

Frequently Asked Questions - PX9134 IFM

What is the power supply voltage for the IFM PX9134?
The power supply voltage is 24 VDC.
How do I connect the sensor to a PLC?
Connect the output signal (4-20 mA or IO-Link) to the analog input of your PLC. Refer to the manual for wiring diagrams.
What is the output signal of the PX9134?
The output signal is 4-20 mA analog or IO-Link digital.
Is the sensor suitable for wet environments?
Yes, it has IP67 protection, meaning it is dust-tight and can withstand temporary submersion.
How should I clean the sensor?
Clean with a dry cloth. Do not use solvents or harsh chemicals.
What is the operating temperature range?
The operating temperature range is -25 to 80 °C.
Where can I find the user manual?
The user manual can be downloaded for free from notice-facile.com or the IFM website.
What spare parts are available?
Spare parts include connecting cables and mounting brackets.
How do I troubleshoot if there is no output signal?
Check the power supply, wiring connections, and ensure the sensor is within its rated pressure range. See the troubleshooting section in the manual.
Can the sensor be used with IO-Link?
Yes, the PX9134 supports IO-Link for digital communication with IO-Link masters.

User questions about PX9134 IFM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Sensor in PDF format for free! Find your manual PX9134 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PX9134 by IFM.

USER MANUAL PX9134 IFM

Installation Instructions

Electronic pressure sensor

efectorsoo®

PX3111

PX322x

PX323x

PX3244

PX3422

PX911x

PX913x

IFM PX9134 - 1

natural_image Technical line drawing of a mechanical component with hexagonal base and threaded top (no text or symbols)

Contents

1 Safety instructions ....2
2 Function and features ....4
3 Installation....5
4 Electrical connection ....5
5 Scale drawing 6
6 Technical data....8

1 Safety instructions

Please read the product description prior to installing the unit. Please check that the product is suitable for your application without any restrictions.

If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur.

Please check in all applications that the product materials (see Technical data) are compatible with the media to be measured.

For gaseous media the application is limited to max. 363 PSI.

High-pressure units (5000 PSI) are supplied with a pressure relief mechanism and an integrated damping device to comply with the regulations for UL approval and to avoid any risk of injury in case of bursting when bursting pressure is exceeded.

IFM PX9134 - Safety instructions - 1

Any manipulation of the damping device is not permissible.

When the damping device is removed, there is no damping function any more. ATTENTION: risk of injury!

For units with cULus approval this approval becomes invalid when the damping device is removed.

For units with cULus approval and the scope of validity cULus:

The device shall be supplied from an isolating transformer having a secondary Listed fuse rated as noted in the following table.

Overcurrent protection
Control-circuit wire sizeMaximum protective device rating Ampere
AWG (mm) 2
26 (0.13) 1
24 (0.20) 2
22 (0.32) 3
20 (0.52) 5
18 (0.82) 7
16 (1.3) 10

The Sensor shall be connected only by using any R/C (CYJV2) cord, having suitable ratings.

2 Function and features

The pressure sensor detects the system pressure and converts it into an analog output signal.

  • 0 to 10 V (PX9xxx)
    • 10 to 0 V (PX9119)
    • 4 to 20 mA (PX3xxx)
    • 20 to 4 mA (PX3229)

Applications (type of pressure: relative pressure)

Order no.Measuring rangePermissible overload pressureBursting pressure
PSI PSI PSI
PX3220PX91100 to 5000 1160017400
PX3111PX91110 to 3000 580012300
PX3222PX91120 to 1000 43509400
PX3223 0 to500 2175 5075
PX3224PX91140 to 100 1087 2175
PX3244 0 to150 1087 2175
PX9134 0 to200 1087 2175
PX3226PX91160 to 30 290 725
PX3237 0 to20 145 450
PX3227PX91170 to 15 145 450
PX32380 to 5145 450
PX3229PX9119-14.5 to 0 (vacuum)145 450
PX3422-14.5 to 735.54350 9400
inH2OinH2OinH2O
PX3228PX91180 to 100 401512043

IFM PX9134 - Function and features - 1

Avoid static and dynamic overpressure exceeding the given over-load pressure.

Even if the bursting pressure is exceeded only for a short time the unit can be destroyed (danger of injuries)!

3 Installation

IFM PX9134 - Installation - 1

Before mounting and removing the sensor, make sure that no pressure is applied to the system.

Mount the pressure sensor on a suitable process connection (see type label “Port Size”).

4 Electrical connection

IFM PX9134 - Electrical connection - 1

The unit must be connected by a qualified electrician.

The national and international regulations for the installation of electrical equipment must be adhered to.

Voltage supply to EN50178, SELV, PELV.

▶ Disconnect power before connecting the unit as follows:

Voltage output (PX9xxx)

1 2 4 3 1 2 4 3 L+ n.c. L- L-

Current output (PX3xxx)

1 2 4 3 L+ L- n.c. n.c.

For information about available sockets/connectors see:

www.ifm.com → Products → Accessories

5 Scale drawing

PX3220 PX9110 PX3111PX9111
PX3222 PX9112
PX3422
IFM PX9134 - Electrical connection - 4IFM PX9134 - Electrical connection - 5
1: Pressure relief mechanismNo mechanical force must be exerted onthe pressure relief mechanism.

dimensions are in millimeters (25.4 mm = 1 inch) process connection 1/4 NPT, tigtening torque 25 Nm

PX3223 PX9114PX3224 PX9116PX3244 PX9117PX3226 PX9118PX3227 PX9119PX3228 PX9134PX3229PX3237PX3238
IFM PX9134 - Electrical connection - 6IFM PX9134 - Electrical connection - 7
1: Ventilation 1: Ventilation

dimensions are in millimeters (25.4 mm = 1 inch) process connection 1/4 NPT, tigtening torque 25 Nm

6 Technical data

PX3xxxOperating voltage [V]....9.6 to 32 DC1)Analog output....4 to 20 mALoad [Ω]....max. (UB- 9,6) x 50; 720 at UB= 24 V DCTep response time analog output [ms]....3
PX9xxxOperating voltage [V]....16 to 32 DC1)Current consumption [mA]....< 18Analog output....0 to 10 V DCLoad [Ω]....min. 2000Step response time analog output [ms]....3
Characteristics deviation (in % of full range)PX3111, PX9111 ....< ± 0.35 (BFSL) / < ± 0.75 (FR)PX3220, PX3222, PX3223, PX3422, PX9112 ....< ± 0.35 (BFSL) / < ± 0.75 (FR)PX3224, PX3244, PX9114 ....< ± 0.35 (BFSL) / < ± 0.75 (FR)PX3226, PX9116....< ± 0.35 (BFSL) / < ± 0.75 (FR)PX3227, PX3237, PX3238, PX9117 ....< ± 0.25 (BFSL) / < ± 0.5 (FR)PX3228, PX9118....< ± 0.35 (BFSL) / < ± 0.75 (FR)PX3229, PX9119....< ± 0.25 (BFSL) / < ± 0.5 (FR)PX9110....< ± 0.35 (BFSL) / < ± 0.75 (FR)PX9134....< ± 0.35 (BFSL) / < ± 0.75 (FR)Repeatability (in % of full range)PX3111, PX9111....< 0.15PX3220, PX3222, PX3422, PX9112....< 0.15PX3224, PX3244, PX9114....< 0.15PX3226, PX9116....< 0.15PX3223, PX3227, PX9117....< 0.1PX3228, PX9118....< 0.15PX3229, PX9119....< 0.1PX3237, PX3238....< 0.15PX9110....< 0.15PX9134....< 0.1

1) to EN50178, SELV, PELV BFSL = Best Fit Straight Line / FR = full range

Temperature coefficients (TEMPCO) in the compensated temperature range 0 to 80°C(in% of full range/10 °C); greatest TEMPCO of the zero point / of full rangePX3111, PX9111....0.2 / 0.3PX3220, PX3422, PX9110....0.3 / 0.4PX3222, PX9112....0.2 / 0.3PX3223....0.2 / 0.3PX3224, PX3244, PX9114....0.2 / 0.3PX3226, PX9116....0.2 / 0.3PX3227, PX9117....0.15 / 0.2PX3228, PX9118....0.2 / 0.3PX3229, PX9119....0.15 / 0.2PX3237....0.2 / 0.4PX3238....0.3/ 0.5PX9134....0.15 / 0.2
Housing material....stainless steel (316S12); FPM (Viton); PA; EPDM/X (Santoprene)Materials (wetted parts)....stainless steel (303S22); ceramics; FPM (Viton)Operating temperature [°C]....-25 to +80Medium temperature [°C]....-25 to +90Storage temperature [°C]....-40 to +100Protection....IP 68 / IP 69K2)Protection....IP 673)Protection....IP 654)Protection class....IIIInsulation resistance [MΩ]....>100 (500 V DC)Shock resistance [g]....50 (DIN / IEC 68-2-27, 11ms)Vibration resistance [g]....20 (DIN / IEC 68-2-6, 10 - 2000 Hz)
EMCEN 61000-4-2 ESD:....4 kV / 8 KV ADEN 61000-4-3 HF radiated:....30 V/mEN 61000-4-4 Burst:....2 KVEN 61000-4-6 HF conducted:....10 VRadiation of interference: according to the road vehicle guideline 2004/104/EC / CISPR25Noise immunity:....according to the road vehicle guideline 2004/104/EC / ISO 11452-2HF conducted:....100 V/mPulse resistance:....according to ISO7637-2 / severity level 3

2) for PX3111, PX3220, PX3222, PX3422, PX9110, PX9111, PX9112,
3) for PX3237, PX3238
4) for PX3223, PX3224, PX3226, PX3227, PX3228, PX3229, PX3244
PX9114, PX9116, PX9117, PX9118, PX9119, PX9134

More information at www.ifm.com