APC

SRTGRK1 - Inverter APC - Free user manual and instructions

Find the device manual for free SRTGRK1 APC in PDF.

📄 16 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice APC SRTGRK1 - page 8
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Uninterruptible Power Supply (UPS)
Model SRTGRK1
Brand APC
VA Rating 1000 VA
Watt Rating 900 W
Input Voltage 220-240 VAC
Output Voltage 220-240 VAC
Form Factor Rack/Tower Convertible
Dimensions (H x W x D) 8.5 x 17.1 x 20.0 in (216 x 435 x 508 mm)
Weight 58.7 lbs (26.6 kg)
Battery Type Lead-Acid, replaceable
Typical Backup Time at Half Load 10-15 minutes
Interfaces USB, Serial, SmartSlot
Surge Protection Yes, 480 Joules
Audible Alarms Battery fault, overload, low battery
Operating Temperature 32-104 °F (0-40 °C)
Maintenance Replace battery every 3-5 years; keep vents clean
Safety Certifications UL, CSA, FCC Class A
Spare Parts Available Battery cartridge, fan assembly
Repairability Field-replaceable battery, fan; other service by technician
Warranty 2 years (extendable)

Frequently Asked Questions - SRTGRK1 APC

What is the typical runtime of the APC SRTGRK1 UPS at full load?
At full load (900W), the runtime is approximately 4-6 minutes, depending on battery age and condition.
How do I replace the battery in the APC SRTGRK1?
The battery is hot-swappable and located behind the front bezel. Disconnect the battery connector, slide out the old battery, insert the new one, and reconnect. No tools required.
Can the APC SRTGRK1 be mounted in a rack?
Yes, it includes rack-mounting hardware and can be installed in a standard 19-inch rack, occupying 2U of space.
What does the 'overload' alarm indicate?
The overload alarm sounds when the connected load exceeds the rated capacity (900W). Reduce the load immediately to prevent shutdown.
Does the APC SRTGRK1 provide surge protection?
Yes, it offers 480 Joules of surge protection for connected equipment against power spikes and lightning.
How can I monitor the UPS status?
You can monitor via the front panel LCD, USB connection to a computer with PowerChute software, or through the optional network management card.
What is the recommended maintenance schedule?
Replace the battery every 3-5 years. Clean the vents annually to prevent dust buildup and ensure proper cooling.
What spare parts are available for the SRTGRK1?
Common spare parts include the battery cartridge (APCRBC140) and fan assembly. Contact APC support for ordering.
Can I connect a generator to the APC SRTGRK1?
Yes, but the generator must provide stable sine wave output and the UPS may switch to battery mode if the frequency deviates beyond ±3 Hz.
Where can I find the user manual for the APC SRTGRK1?
The manual is available for free download on notice-facile.com or the APC official website in PDF format.

User questions about SRTGRK1 APC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Inverter in PDF format for free! Find your manual SRTGRK1 - APC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SRTGRK1 by APC.

USER MANUAL SRTGRK1 APC

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : APC

Model : SRTGRK1

Category : Inverter