Product Type TouchLink Pro Touchpanel
Display Size 7 inches diagonal
Resolution 800 x 480 pixels
Touch Technology Resistive or capacitive
Dimensions (H x W x D) 4.8 x 7.5 x 1.6 inches (122 x 191 x 41 mm)
Weight 1.3 lbs (0.59 kg)
Power Source PoE (Power over Ethernet) or 12V DC
Power Consumption 15 W max
Communication Ethernet, RS-232, IR, USB
Supported Protocols IP, TCP, UDP, HTTP, SNMP
Main Functions AV control, room scheduling, presentation switching
Configuration Software Extron Global Configurator Plus/Professional
Mounting Options Wall mount, desktop stand, or VESA
Operating Temperature 32 to 104 °F (0 to 40 °C)
Storage Temperature -4 to 158 °F (-20 to 70 °C)
Humidity 10% to 90% non-condensing
Safety Certifications CE, FCC, UL, RoHS
Cleaning Instructions Wipe with dry soft cloth; mild detergent if needed
Repairability Contact authorized Extron service center

Frequently Asked Questions - TLP 700MV Extron

How do I reset the Extron TLP 700MV to factory defaults?
Press and hold the recessed reset button on the side of the panel for 5 seconds until the screen flashes. This will restore factory settings.
What power supply is required for the TLP 700MV?
The TLP 700MV supports Power over Ethernet (PoE) (802.3af) or an optional 12V DC power supply (part #70-775-01).
Can I mount the TLP 700MV on a wall?
Yes, the TLP 700MV can be mounted on a wall using the included wall mount bracket or a standard VESA mount.
How do I clean the touchscreen?
Use a soft, lint-free cloth slightly dampened with water or a mild screen cleaner. Avoid abrasive materials or liquids.
What software do I need to configure the TLP 700MV?
Use Extron Global Configurator Plus or Professional to design and upload control interfaces.
Does the TLP 700MV support RS-232 control?
Yes, the rear panel includes an RS-232 port for serial control of external devices.
What is the touchscreen resolution?
The TLP 700MV features an 800 x 480 pixel resistive touchscreen display.
How do I update the firmware?
Download the latest firmware from the Extron website and upload via the control software or a USB drive.
What is the warranty period?
Extron offers a standard 3-year parts and labor warranty for the TLP 700MV.
Can the TLP 700MV be used for room scheduling?
Yes, with appropriate configuration software, it can display room schedules and support booking via touch.

User questions about TLP 700MV Extron

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Wall touchscreen in PDF format for free! Find your manual TLP 700MV - Extron and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TLP 700MV by Extron.

USER MANUAL TLP 700MV Extron

The Extron® EWB 700 is an optional accessory for mounting the TLP 700MV touchpanel onto the surface of various wall types (such as drywall, wood, or masonry) where it is not possible to embed the touchpanel in the wall. The EWB 700 has knockouts that accept raceways or conduit for running cables over the surface of the wall to the touchpanel.

The following items are required for installation, but are not supplied:

• Extron TLP 700MV (includes Extron TR 700M Trim Ring)
- Four screws (Extron recommends a minimum length of 1 inch, if possible)
- Power drill
- Drill bit that is appropriate for wall type
- Conduit or surface raceway to carry cables
- Screwdriver
Level

Conduit Cables Extron EWB 700 Wall Box Extron TR 700M Trim Ring Extron TLP 700MV Extron TLP 700MV Faceplate ) tends a (if possible) or wall type

Fastener Suggestions for Different Wall Types

Choose a type of screw or bolt that is appropriate for the wall (see table below). The mounting holes in the back of the EWB 700 accommodate screws up to 1/4 inch in diameter.

Wall TypeFasteners Min. Size FastenerQuantity Drill Bit SizeNotes
Drywall Togglele bolts 3/16 inch 4 1/2 inch Min. 3/8 inchwall thickness
Wood (solid wall or stud)Wood screws #10 screw with a washer4 1/16 inch wood bitMin. 3/8 inch wall thickness
Masonry Masonry screws1/4 inch 4 3/16 inchmasonry bitDo not mount to masonry joints

Mounting the EWB 700

  1. If mounting to standard wood wall studs, locate the center of the studs.
  2. Place the EWB 700 against the wall in a suitable location. Use a level to ensure the box is horizontal and mark the position of the four holes.
  3. If required, drill four holes into the wall.
  4. Insert four screws (see the table above) and attach the EWB 700 to the wall.

Mounting Screws (4)

EWB 700 User Guide (cont'd)

  1. Remove the required knockout and run conduit or raceway to the EWB 700.
  2. Pull the cables through the conduit, the EWB 700 knockout, and the Extron TR 700M trim ring (provided with the Extron TLP 700MV).
  3. Attach the trim ring to the EWB 700 using four #6-32 screws (provided).

CAUTION: Do not overtighten the screws. Use a manual screwdriver.

⑥ ⑦ Trim Ring Screws (4)

Installing the TLP 700MV

  1. Remove the faceplate from the TouchLink panel.
  2. Attach the cables to the back of the TLP 700MV. There are three sets of cables:

• One cable for the 12 VDC power input
- Two cables with BNC connectors for video (optional)
• One network cable with a RJ-45 connector for network connection

Power Input Video Input Network Connection

  1. Fold the locking arms into their recesses on the side of the TLP 700MV and slide the unit into the wall box. Tighten the screws on the front of the unit to hold the unit in place. The locking arms rotate behind the EWB 700 and trim ring.
  2. Configure the TLP 700MV as described in the TLP 700MV and TLP 700TV User Guide.
  3. Snap the faceplate into position (four clips on each side).

Locking Arm (6) 10 12

Extron USA - West HeadquartersExtron USA - EastExtron EuropeExtron AsiaExtron JapanExtron ChinaExtron Middle East
+800.633.9876Inside USA/Canada Only+800.633.9876Inside USA/Canada Only+800.3987.6673Inside Europe Only+800.7339.8766Inside Asia Only+81.3.3511.7655+81.3.3511.7656 FAX+400.883.1568Inside China Only+971.4.2991800+971.4.2991880 FAX
+1.714.491.1500+1.714.491.1517 FAX+1.919.863.1794+1.919.863.1797 FAX+31.33.453.4040+31.33.453.4050 FAX+65.6383.4400+65.6383.4664 FAX+86.21.3760.1568+86.21.3760.1566 FAX
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Extron

Model : TLP 700MV

Category : Wall touchscreen