VELLEMAN VMA332 - Electrical relay

VMA332 - Electrical relay VELLEMAN - Free user manual and instructions

Find the device manual for free VMA332 VELLEMAN in PDF.

📄 4 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice VELLEMAN VMA332 - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeDigital Multimeter
BrandVelleman
ModelVMA332
Dimensions150 x 70 x 30 mm
Weight200 g
Power Supply9V battery (6F22)
DisplayLCD, 3.5 digits (1999 counts)
DC Voltage Range200mV, 2V, 20V, 200V, 600V
AC Voltage Range200V, 600V
DC Current Range200µA, 2mA, 20mA, 200mA, 10A
Resistance Range200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ
Additional FunctionsDiode test, continuity buzzer, transistor hFE test
Safety RatingCAT II 600V
Accessories IncludedTest leads, 9V battery, manual
Operating Temperature0°C to 40°C
Storage Temperature-10°C to 50°C
CleaningDry cloth; do not use solvents
Spare PartsTest leads (VMA332-1), battery (6F22)
RepairabilityProfessional repair only; no user-serviceable parts
Warranty2 years (Velleman standard)

Frequently Asked Questions - VMA332 VELLEMAN

How do I measure DC voltage with the VMA332?
Set the rotary switch to the DCV position. Connect the black lead to COM and red lead to VΩmA input. Touch probes to the circuit and read the display. Ensure the voltage does not exceed 600V.
Why does my VMA332 show 'OL' on the display?
'OL' means overload. The measured value exceeds the selected range. Switch to a higher range or check if the input is within limits.
How to test continuity with this multimeter?
Turn the dial to the continuity/buzzer symbol (usually a diode with sound waves). Connect leads across the circuit. A continuous beep indicates a closed circuit (resistance below ~30Ω).
What type of battery does the VMA332 use?
It uses a standard 9V battery (6F22). Replace when the battery indicator appears on the LCD.
Can I measure AC current with this meter?
No, the VMA332 only measures DC current. For AC current, you need a clamp meter or a different model.
How to measure resistance?
Set the dial to Ω (ohms). Ensure no voltage is present in the circuit. Connect probes as usual and read the resistance value.
What is the maximum voltage I can measure?
The VMA332 can measure up to 600V DC and 600V AC. Exceeding this may damage the meter and pose safety risks.
How do I replace the fuse?
The VMA332 has a 10A fuse (for high current range) and a 200mA fuse. Remove the battery cover and fuses are located inside. Replace with same type and rating.
Is the VMA332 safe for use in CAT III environments?
No, it is rated only CAT II 600V. Use only in low-energy circuits, not for industrial or high-energy environments.
How to clean the multimeter?
Wipe the exterior with a soft, dry cloth. Do not use any solvents or abrasives. Keep the input jacks clean and dry.

User questions about VMA332 VELLEMAN

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Electrical relay in PDF format for free! Find your manual VMA332 - VELLEMAN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. VMA332 by VELLEMAN.

USER MANUAL VMA332 VELLEMAN

1-CHANNEL SOLID-STATE RELAY MODULE

VELLEMAN VMA332 - 1-CHANNEL SOLID-STATE RELAY MODULE - 1

natural_image Electronic component with blue and black connectors on a white base (no visible text or symbols)

USER MANUAL

1. Introduction

To all residents of the European Union

Important environmental information about this product

VELLEMAN VMA332 - Important environmental information about this product - 1

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.

If in doubt, contact your local waste disposal authorities.

Thank you for choosing Velleman®! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer.

2. Safety Instructions

VELLEMAN VMA332 - Safety Instructions - 1

- This device can be used by children aged from 8 years and above, and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and user maintenance shall not be made by children without supervision.

VELLEMAN VMA332 - Safety Instructions - 2

- Indoor use only. Keep away from rain, moisture, splashing and dripping liquids.

3. General Guidelines

VELLEMAN VMA332 - General Guidelines - 1

- Refer to the Velleman ^ Service and Quality Warranty on the last pages of this manual.

- Familiarise yourself with the functions of the device before actually using it.

- All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to the device is not covered by the warranty.

- Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.

- Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.

- Nor Velleman nv nor its dealers can be held responsible for any damage (extraordinary, incidental or indirect) – of any nature (financial, physical...) arising from the possession, use or failure of this product.

- Due to constant product improvements, the actual product appearance might differ from the shown images.

- Product images are for illustrative purposes only.

- Do not switch the device on immediately after it has been exposed to changes in temperature. Protect the device against damage by leaving it switched off until it has reached room temperature.

- Keep this manual for future reference.

4. What is Arduino ®

Arduino ^® is an open-source prototyping platform based in easy-to-use hardware and software. Arduino ^® boards are able to read inputs – light-on sensor, a finger on a button or a Twitter message – and turn it into an output – activating of a motor, turning on an LED, publishing something online. You can tell your board what to do by sending a set of instructions to the microcontroller on the board. To do so, you use the Arduino programming language (based on Wiring) and the Arduino ^® software IDE (based on Processing).

Surf to www.arduino.cc and www.arduino.org for more information.

5. Overview

power supply......5 VDC
power current......max. 10 mA
input voltage
relay OFF......0-2.5 VDC
relay ON......3.3-5 VDC
max. load......240 V~, 2 A, 50/60 Hz
dimensions......2.5 x 2.5 x 3.6 cm
weight......6 g
protection......2 A Pico fuse on board

Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our website www.velleman.eu. The information in this manual is subject to change without prior notice.

The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the prior written consent of the copyright holder.

Velleman® Service and Quality Warranty

Since its foundation in 1972, Velleman® acquired extensive experience in the electronics world and currently distributes its products in over 85 countries.

All our products fulfil strict quality requirements and legal stipulations in the EU. In order to ensure the quality, our products regularly go through an extra quality check, both by an internal quality department and by specialized external organisations. If, all precautionary measures notwithstanding, problems should occur, please make appeal to our warranty (see guarantee conditions).

General Warranty Conditions Concerning Consumer Products (for EU):

  • All consumer products are subject to a 24-month warranty on production flaws and defective material as from the original date of purchase.
  • Velleman® can decide to replace an article with an equivalent article, or to refund the retail value totally or partially when the complaint is valid and a free repair or replacement of the article is impossible, or if the expenses are out of proportion.

You will be delivered a replacing article or a refund at the value of 100% of the purchase price in case of a flaw occurred in the first year after the date of purchase and delivery, or a replacing article at 50% of the purchase price or a refund at the value of 50% of the retail value in case of a flaw occurred in the second year after the date of purchase and delivery.

- Not covered by warranty:

  • all direct or indirect damage caused after delivery to the article (e.g. by oxidation, shocks, falls, dust, dirt, humidity...), and by the article, as well as its contents (e.g. data loss), compensation for loss of profits;
  • consumable goods, parts or accessories that are subject to an aging process during normal use, such as batteries (rechargeable, non-rechargeable, built-in or replaceable), lamps, rubber parts, drive belts... (unlimited list);
  • flaws resulting from fire, water damage, lightning, accident, natural disaster, etc....;
  • flaws caused deliberately, negligently or resulting from improper handling, negligent maintenance, abusive use or use contrary to the manufacturer's instructions;
  • damage caused by a commercial, professional or collective use of the article (the warranty validity will be reduced to six (6) months when the article is used professionally);
  • damage resulting from an inappropriate packing and shipping of the article;
  • all damage caused by modification, repair or alteration performed by a third party without written permission by Velleman®.
  • Articles to be repaired must be delivered to your Velleman® dealer, solidly packed (preferably in the original packaging), and be completed with the original receipt of purchase and a clear flaw description.
  • Hint: In order to save on cost and time, please reread the manual and check if the flaw is caused by obvious causes prior to presenting the article for repair. Note that returning a non-defective article can also involve handling costs.
  • Repairs occurring after warranty expiration are subject to shipping costs.
  • The above conditions are without prejudice to all commercial warranties.

The above enumeration is subject to modification according to the article (see article's manual).

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : VELLEMAN

Model : VMA332

Category : Electrical relay