| Product Type | Uninterruptible Power Supply (UPS) |
| Model | 6A0BT000002 |
| Brand | Salicru |
| Power Rating (VA) | 600 VA |
| Power Rating (Watts) | 360 W |
| Input Voltage | 230 V AC |
| Output Voltage | 230 V AC ± 10% |
| Battery Type | Sealed lead-acid, maintenance-free |
| Battery Backup Time | Approx. 10-15 minutes at full load |
| Number of Outlets | 2-4 (IEC or Schuko) |
| Surge Protection | Yes, with built-in surge suppressor |
| Dimensions (W x D x H) | 280 x 140 x 85 mm |
| Weight | 4.0 kg |
| Operating Temperature | 0°C to 40°C |
| Audible Noise | < 40 dB at 1 meter |
| Main Functions | Voltage regulation, battery backup, surge protection, overload protection |
| Indicators | Power, battery, overload, fault LEDs |
| Cleaning | Wipe with a dry cloth; do not use liquids |
| Safety | Overload protection, short circuit protection, battery deep discharge protection |
| Spare Parts & Repairability | User-replaceable battery; other repairs by qualified personnel only |
| Warranty | 2 years (standard) |
Frequently Asked Questions - 6A0BT000002 Salicru
How do I connect my devices to the Salicru 6A0BT000002 UPS?
Connect your critical devices (e.g., computer, monitor) to the surge-protected outlets on the back of the UPS. Ensure the total power draw does not exceed 360W.
What do the LED indicators mean?
The Power LED is green when on utility power. The Battery LED is orange when on battery. The Overload LED flashes if load exceeds capacity. The Fault LED indicates a problem.
How long does the battery last?
The battery provides backup for approximately 10-15 minutes at full load (360W). Runtime increases with lighter loads.
Can I replace the battery myself?
Yes, the battery is user-replaceable. Refer to the manual for the correct replacement procedure and battery type.
What should I do if the UPS beeps continuously?
Continuous beeping often indicates a low battery or overload. Check the load and battery charge. If the alarm persists, consult the manual.
Is the UPS also a power surge protector?
Yes, the Salicru 6A0BT000002 includes surge protection to safeguard connected equipment from voltage spikes.
How do I perform a self-test?
Press and hold the Test button for about 2 seconds. The UPS will switch to battery briefly to check functionality. LEDs will indicate results.
What type of battery does it use?
It uses a sealed lead-acid (SLA) battery, typically 12V 7Ah. Refer to the manual for exact specifications.
Can I use the UPS with a generator?
Yes, it can accept power from a generator, but ensure the generator output is stable and within 230V ±10% to avoid damage.
How often should I replace the battery?
Batteries typically last 3-5 years. Replace earlier if runtime becomes insufficient or the battery fails a self-test.
User questions about 6A0BT000002 Salicru
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Inverter in PDF format for free! Find your manual 6A0BT000002 - Salicru and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 6A0BT000002 by Salicru.