| Product Type | Portable Generator |
| Brand | DuroMax |
| Model | XP5500HX |
| Power Output (Starting) | 5500 Watts |
| Power Output (Running) | 4500 Watts |
| Engine Displacement | 212 cc |
| Engine Type | 4-Stroke, OHV, Single Cylinder |
| Fuel Type | Gasoline |
| Fuel Tank Capacity | 7.0 Gallons |
| Run Time at 50% Load | Up to 10 Hours |
| Starting System | Recoil Start (Manual) |
| Outlets | (2) 120V 20A GFCI, (1) 120/240V 30A Twist-Lock, (1) 12V DC |
| Noise Level | 68 dB at 23 feet |
| Dimensions (L x W x H) | 27.0 x 22.0 x 22.0 inches |
| Weight | 130 lbs |
| Oil Capacity | 1.2 quarts |
| Spark Plug Type | BPR6ES (or equivalent) |
| Warranty | 3 Year Limited Warranty |
| Maintenance | Oil change every 50 hours; air filter cleaning |
| Safety Features | Low Oil Shutdown, GFCI Outlets, Automatic Voltage Regulation |
Frequently Asked Questions - XP5500HX DuroMax
What type of oil should I use?
Use a high-quality 10W-30 oil for general use. For extreme temperatures, refer to the viscosity chart in the manual.
How often should I change the oil?
Change the oil every 50 hours of operation or at least once a season, whichever comes first.
Can I run the generator in the rain?
No, never operate the generator in rain or wet conditions. Use a weatherproof cover and place it under a canopy if needed.
How do I break in the engine?
During the first 5 hours, do not apply heavy loads. Vary the load and avoid prolonged idling. After break-in, change the oil.
What is the correct starting procedure?
Ensure fuel and oil are filled. Turn fuel valve on, close choke, pull recoil starter slowly until resistance, then pull firmly. Once running, open choke gradually.
How do I store the generator?
Drain fuel or add stabilizer. Run engine until carburetor is dry. Change oil, clean air filter, and store in a dry, ventilated area.
What are the outlets and their uses?
The generator has two 120V 20A GFCI outlets for standard household devices, one 120/240V 30A twist-lock for heavier loads, and a 12V DC outlet for battery charging.
How long will it run on a full tank?
At 50% load, the generator runs up to 10 hours. Runtime decreases with higher loads.
What maintenance is required?
Regularly check oil level, clean air filter, inspect spark plug, and change oil every 50 hours. Also check fuel lines for cracks.
Why does the generator shut off unexpectedly?
Possible causes: low oil level (triggers shutdown), overloaded circuit, dirty air filter, or empty fuel tank. Check these first.