DS70504 - Measurement Rigol - Free user manual and instructions
Find the device manual for free DS70504 Rigol in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Digital Oscilloscope |
| Bandwidth | 5 GHz |
| Number of Channels | 4 |
| Maximum Sample Rate | 20 GSa/s |
| Memory Depth | 500 Mpts per channel |
| Display | 12.1-inch capacitive touchscreen |
| Vertical Resolution | 8 bits |
| Time Base Range | 50 ps/div to 1000 s/div |
| Input Impedance | 50 Ω / 1 MΩ |
| Trigger Types | Edge, Pulse, Video, Slope, Pattern, Serial |
| Supported Protocols | I2C, SPI, UART, CAN, LIN, FlexRay, USB |
| Connectivity | USB 3.0, LAN, HDMI, GPIB (optional) |
| Power Supply | 100-240 VAC, 50/60 Hz |
| Dimensions (W x H x D) | 450 x 270 x 140 mm |
| Weight | 10 kg |
| Safety Compliance | CAT I 400 V, CAT II 300 V |
| Operating Temperature | 0°C to 50°C |
| Maintenance | Clean with dry cloth; avoid solvents |
| Spare Parts & Repairability | Contact Rigol authorized service centers |
Frequently Asked Questions - DS70504 Rigol
How do I update the firmware on the DS70504?
Download the latest firmware from Rigol's website, save it to a USB drive, insert into the oscilloscope, and navigate to Utility > Update Firmware.
What probes are compatible with the DS70504?
Use high-impedance passive probes (10 MΩ) or 50 Ω active probes. Recommended models include the RP3500 or RP5600 series.
Can I measure differential signals?
Yes, with a differential probe. The oscilloscope supports external differential probes via the probe compensation output.
How to perform a self-calibration?
Disconnect all inputs, press Utility > Calibration > Self Cal. Follow on-screen instructions. Calibration takes about 5 minutes.
What file formats does the DS70504 support for saving waveforms?
Supports CSV, TXT, BIN, PNG, JPG, and TIFF for images. Waveform data can be saved in CSV or binary format.
How to connect to a PC?
Use the USB 3.0 port or LAN. Install the Rigol Ultra Sigma software for remote control and data transfer.
What is the maximum input voltage?
For 1 MΩ input: 400 V (DC + AC peak). For 50 Ω input: 5 V RMS. Refer to the manual for derating at high frequencies.
How to enable serial decoding?
Press Decode button, select protocol (e.g., I2C), assign clock/data lines, and set threshold voltages. Decoded data appears on screen.
Does the oscilloscope include a built-in function generator?
No, the DS70504 does not have an integrated function generator. You can use an external waveform generator via the trigger input.
How to clean the touchscreen?
Turn off the oscilloscope. Use a soft, lint-free cloth slightly dampened with water or mild soap. Do not spray directly on the screen.
User questions about DS70504 Rigol
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Measurement in PDF format for free! Find your manual DS70504 - Rigol and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DS70504 by Rigol.