Product Type Bathroom Heater (3 in 1: Heat, Fan, Light)
Brand Martec
Model Profile Panel 2 (MBHN2LW, MBHN2LS)
Rated Voltage 220V-240V
Rated Frequency 50 Hz
Rated Power 602 W
Heating Lamps 2 x 275W E27 infrared heat lamps
Light Lamp 1 x 12W max LED (E27)
Functions Heating, exhaust fan, LED lighting
Installation Type Ceiling mounted (flat ceiling only)
Duct Diameter 125 mm
Max Duct Length 3.0 m
Recommended Mounting Height Heat lamps no more than 2.3 m from floor
Safety Certification Complies with AS/NZS3000 (Australia/New Zealand)
Warranty 3 years (excluding lamps and installation)
Maintenance Clean with soft cloth and neutral detergent; replace lamps as specified
Included Accessories Operation unit, infrared lamps (2), light lamp, installation instructions, warranty card, ventiduct kit, duct clips (2), switch

Frequently Asked Questions - Profile Panel 2 Martec

Can I install this heater myself?
No, installation must be carried out by a licensed electrician in accordance with local codes and standards.
What type of lamps does the Profile Panel 2 use?
It uses 2 x 275W E27 infrared heat lamps and 1 x 12W maximum LED lamp for lighting.
Can the heater be installed above a bathtub or shower?
No, the unit should not be installed directly above a bathtub or shower, and must be placed where water cannot splash onto the lamps.
How do I clean the heater?
Turn off the power and allow lamps to cool. Wipe lamps and fascia with a soft cloth dampened with neutral detergent.
What is the warranty period?
The unit is warranted for 3 years against manufacturing defects, excluding lamps, installation, and associated wiring.
Can I use the heater on a sloped ceiling?
No, the unit is designed for flat ceilings only. Do not mount on sloping ceilings or vertical walls.
What does the warranty not cover?
The warranty does not cover heat/light lamps, damage from incorrect installation or operation, modifications, or consequential losses.
How often should I replace the lamps?
Check and tighten lamps regularly. Replace the infrared lamps with 275W E27 and the LED light with a 12W maximum as needed.
What is the maximum distance from the heater to the outside vent?
The duct length should be within 3.0 meters from the center of the installation position to the outside vent.
Can I operate the heater without the fan?
Yes, each function (heat, fan, light) has its own on/off button and can be used independently.

User questions about Profile Panel 2 Martec

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Heating in PDF format for free! Find your manual Profile Panel 2 - Martec and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Profile Panel 2 by Martec.

USER MANUAL Profile Panel 2 Martec

INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE

MARTREC®

BATHROOM HEATER

PROFILE PANEL 2

3 IN 1 HEAT, FAN, LIGHT

Dear customers,

Thank you for selecting Martec Bathroom Heater 3 in 1. Please read all instructions before commencing installation.

IMPORTANT: This unit must be installed to comply with the appropriate council regulations and the Australia and New Zealand wiring rules AS/NZS3000:2000 or lastest edition thereof.

The main supply and interconnecting cables required for installation of this unit are not included.

WARNING - INSTALLATION ONLY TO BE BY QUALIFIED PERSONS

  1. Use this heater only as described in this manual. The manufacturer does not recommend any other use as this may cause fire, electric shock, or injury to persons. If you have questions, contact the manufacture or local agent.

  2. All wiring must be carried out by a Licensed Electrician in accordance with all applicable codes and standards.

  3. Make sure the power is off before the installation.

  4. When cutting into the wall, do not damage electrical wiring and other hidden utilities.

5.The heater must be properly grounded.

  1. The lamps are hot when in use. Do not touch the infrared lamps with any part of your body when in use.

  2. For the purpose of avoiding any dangerous gas leaking into your bathroom, the ventiduct of the heater must not be laid together with the ventiduct of air-fueled water heater or other open-fire appliances into the same flue.

  3. The disconnection may be achieved by having the plug accessible or by incorporating a switch in the fixed wiring in accordance with the wiring rules. The heater must be isolated from the power by means of a plug or all-pole disconnection switch with a contact separation of at least 3mm in each pole.

  4. The power cable must stand a minimum 5A load.

  5. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

  6. Children should be supervised to ensure that they do not play with the appliance.

  7. The heater is to be installed so that switches and other controls cannot be touched by a person in the bath or shower.

  8. The appliance shall, under no circumstances, be covered with insulating material or similar material.

  9. Regulations concerning the discharge of air have to be fulfilled.

  10. Joists, beams and rafters shall not be cut or notched to install the appliance.

IMPORTANT CONSIDERATIONS BEFOR INSTALLING

A few minutes of planning can make a big difference to the installation time and also to your satisfaction with the function of the unit.

  1. The unit should not be installed directly above a shower or bathtub. The unit must not be installed in a position where water may splash onto the lamps.
  2. The unit must not be installed beneath a fixed socket.
  3. The unit is designed for installation in flat ceilings only. Do not mount it on a sloping ceiling or a vertical wall.
  4. The infrared lamps are most effective when you are standing directly beneath them, so generally the unit would be mounted a place where you would stand to dry yourself.
  5. For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be able to enter the room. Generally, this air would be drawn under the door, or through a slightly open window. If the room is airtight, the fan will function poorly.
  6. Before commencing any cutting, check in the ceiling space that there are no obstructions such as ceiling joists and that there is sufficient height clearance for the housing. Check that the electrical wiring can be routed from the wall switches to the mounting location.

INSTALLATION

1. Cutting a vent

Locate a vent position (above the ceiling) on the wall, and then cut a 130mm diameter hole at this very position.

2. Ducting

Put one end of the 125mm diameter ventiduct into the vent hole and seal space around the hole using a suitable sealant and cowling where necessary.

Note: Since the length of each duct is 3.0m, make sure that from the centre of installation position there should be a distance within 3.0m to the outside vent.

3. Suitable loacation

For the purpose of obtaining the best heating results, the heat lamps should be no more than 2.3m from the ground.

wall sealant ventiduct duct clip bathroom heater ceiling joist ceiling fascia_ infrared lamp Wall venting shown

4. Prepare the ceiling

Cut around the attached hole-cutting template and use this template to mark the hole outline on the ceiling.

Make sure a distance between the edges and wall is no less than 250mm. Also from the rooftop should be a minimum 220mm height to the ceiling.

5. Remove the Fascia

Remove 2 heat lamps from the heater. Unclip the internal fascia-retaining springs inside the housing. Remove the plug of the LED light. Remove the fascia. Note: Do not force when removing the heating lamps.

Martec Profile Panel 2 - Remove the Fascia - 1

6. Wiring

Connect one end of the interconnecting wire with the switch panel, and then drag the other end power cable out of the hole on the ceiling. Open the terminal block cover on the housing and make connection as the wiring diagram instructs, then reposition the terminal block cover. Tuck the redundant wire into the ceiling so as to leave the housing enough room to fix in.

Note: Ensure that the power is turned off before carrying out any work on electrical installations.

Martec Profile Panel 2 - Wiring - 1

M:Motor C:Capacitor IR:Heat lamp IN:Light lamp K:All-pole disconnection switch Θ:Heat protector

INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE

  1. Fit the in-house end of the duct to the fan outlet, and fix the end with duct clip.

Note: Keep the route as straight as possible.

  1. Position the housing into the hole

Choose and optimal direction to put the housing into the hole in accordance with the position of the fan outlet. Use the two spring clips to fix the housing. Ensure that the unit is held securely by the clips.

Note: Try to keep the redundant wire away from the housing.

  1. Final installation

1) Reconnect the LED light plug

2) Replace the fascia

Replace the fascia and retaining springs.

3) Replace the heat lamps

Ensure the lamps are tightened sufficiently to make good electrical contact. Clean the lamps and fascia. 4) Fix the switch panel to the wall

Note: The switch wiring should be mounted inside the wall to give the switch an integrated built in appearance. If it is necessary to run the wiring on the outside of the wall, use a suitable conduit and fixings to properly located and hold the wiring used.

For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be able to enter the room. In general this air would be drawn from under the door, or through a slightly opened window. If the room is air-tight, the fan will function poorly.

Martec Profile Panel 2 - INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE - 1

natural_image Illustration of hands holding a mechanical device with no visible text or symbols

spring clip bathroom heater ≥220mm ceiling ceiling joist 150mm feeling spring fascia infrared lamp

USE

Our bathroom heater uses the infrared heating lamps as a source of heat. It also combines the functions of exhaust and light.

  1. Heat

'HEAT' button On/Off

Each individual infrared lamp has been sprayed with 4°C cold water to ensure that there are no flaws in the construction.

Note: Do not touch the infrared lamps with any part of your body when in use.

  1. Exhaust

'FAN' button On/Off

This unit can exhaust odours and steam in a quick and efficient way by turning on the "FAN" button.

  1. Lighting

'Light' button On/Off

Note: Do not switch on/off frequently when in use. Shut off the power if in long vacancy.

MAINTENANCE

  1. Clean

1) Shut off the power before cleaning.

2) Wipe lamps and fascia with care using a soft cloth soaked with a neutral detergent.

Note: Ensure the lamps are cool to touch before handling.

  1. Lamp Replacement

1) Check and tighten lamps regularly.

2) Shut off power before replacement.

3) Use 12W maximum led lamps for lighting

4) Use 2x275W E27 infrared heat lamps.

Note: It may affect operation (even cause danger) when lamps, other than the designated ones, are used.

WARRANTY

The unit is warranted against defects in manufacturing and workmanship for a period of 3 years. The warranty does not extend to lamp globes supplied or installation of the unit or any associated wiring or any damage caused by installation or wiring.

The installation must be conducted by a licensed electrician and a suitable certificate of safety is to be issued by the electrician who installed the unit. Warranty claims will be voided unless a certificate of safety can be produced when required, prior to service or repair.

This warranty does not cover damages or loss caused by:

1) Heat or light lamps.

2) Any consequential losses arising from incorrect installation or operation or maintenance of this product.

3) Any consequential losses arising from incorrect wiring of this product.

4) Any modifications or changes made to the unit, other than those recommended by the Manufacturer.

ACCC Required Statement

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to Martec replacing the product in home with parts and labour for a major failure. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Martec offers an in home warranty that includes parts and labour so the end consumer is not out of pocket.

MAIN TECHNICAL PARAMETERS

Model NumberMBHN2LW, MBHN2LS
Rated Voltage220V-240V
Rated Frequency50Hz
Rated Power602 W

LIST OF ACCESSORIES

Operation unit1 piece
Infrared lamp (E27)2 pieces
Light lamp1 pieces
Installation instruction & hole-cutting template1 piece
Warranty card1 piece
Ventiduct kit1 set
Duct clip2 piece
Switch1 piece

Name:

Contact No:

Address:

Fill out the following details and file with the purchase invoice for warranty service.

MODEL NO.

Purchased from:

Date of purchase:

/// MARTEC PTY LTD ABN: 82599302308

We reserve the rights to revise this instruction without any prior notice.

Contact details for after sales service.

Phone:0287787500

Fax: 0287787555

Manual assistant