Bio-Haz C82907-00 - Vacuum Cleaner Minuteman - Free user manual and instructions
Find the device manual for free Bio-Haz C82907-00 Minuteman in PDF.
| Product Type | Bio-Hazard Vacuum Cleaner |
| Model Number | C82907-00 (115V) / C82907-02 (230V) |
| Tank Size | 6 Gallons (22 liters) |
| Power | 1.25 HP (0.93 kW), 2-stage motor |
| Dry Capacity | 0.34 cu. ft (0.01 m³/min) |
| Air Flow | 95 CFM (2.69 m³/min) |
| Static Lift | 85 inches (2160 mm) |
| Filtration Type | U.L.P.A. (Ultra Low Penetration Air) |
| Filtration Efficiency | 99.999% at 0.12 microns |
| Sound Level (Operator) | 75 dB(A) |
| Sound Level (at 3m) | 71 dB(A) |
| Vibration at Handle | 0.5 m/s² |
| Voltage | 115 V (model C82907-00) / 230 V (model C82907-02) |
| Power Cord | 50 ft (15 m), 16-3 SJTW |
| Casters | 4 casters, 2 inches (5 cm) each |
| Weight | 17 lbs (8 kg) |
| Construction Material | Polypropylene tank, aluminum intake assembly |
| Intended Use | Hazardous particulate pick-up only (not for vapor recovery) |
| Filter Maintenance | Replace pre-filter every other tank clean-out; replace disposable paper bag and paper filter protector each time bag is full; cloth filter can be cleaned and reused |
| Safety Precautions | Use only approved filters; wear protective clothing and respirator; dispose of contaminated materials per EPA regulations |
| Warranty | Commercial limited warranty: 3 years parts, 2 years labor (cord electric group); specific exclusions apply |
Frequently Asked Questions - Bio-Haz C82907-00 Minuteman
User questions about Bio-Haz C82907-00 Minuteman
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Vacuum Cleaner in PDF format for free! Find your manual Bio-Haz C82907-00 - Minuteman and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Bio-Haz C82907-00 by Minuteman.
USER MANUAL Bio-Haz C82907-00 Minuteman
Excellence Meets Clean

natural_image
Black Minuteman vacuum cleaner with control panel and mounting base (no visible text or symbols on device body)Parts and Instruction Manual
Bio-Haz Vacuum
This manual is furnished with each new MINUTEMAN Bio-Haz Vacuum. This provides the necessary operating and preventive maintenance instructions. Operators must read and understand this manual before operating or servicing this machine.
This machine was designed to give you excellent performance and efficiency. For best results and minimal cost, please follow the general guidelines below:
· Operate the machine with reasonable care.
· Follow the manufacturers suggested maintenance instructions as provided in this booklet.
· Use original Minuteman supplied parts.
TECHNICAL SPECIFICATIONS
Model Bio-Haz Vacuum
| Model No. | C82907-00 | C82907-02 |
| Tank Size | 6 Gal (22 ltr) | 6 Gal (22 ltr) |
| Power | 1.25 HP (.93 kW), 2 stage | 1.25 HP (.93 kW), 2 stage |
| Dry Capacity | .34 cu. ft (.01 m3/min) | .34 cu. ft (.01 m3/min) |
| Air Flow | 95 CFM (2.69 m3/min) | 95 CFM (2.69 m3/min) |
| Static Lift | 85” (2,160 mm) | 85” (2,160 mm) |
| Filter and Efficiency Rating | U.L.P.A. | U.L.P.A. |
| 99.999% efficient | 99.999% efficient | |
| at .12 microns | at .12 microns | |
| Dba Rating | 72 | 72 |
| Voltage | 115V | 230V |
| Casters | 4-2” (5 cm) | 4-2” (5 cm) |
| Cord | 16-3, 50’ (15 m) | 16-3, 50’ (15 m) |
| Weight | 17 lbs (8 kg) | 17 lbs (8 kg) |
EC Declaration of Conformity
according to Directives 72/23, 89/392, and 89/336
We, Minuteman International Incorporated, of 111 South Rohlwing Road Addison Illinois 60101 USA, declare under our sole responsibility that the product C82907-02 & C82917-02 a Critical Filter Vacuum to which this declaration relates corresponds to the relevant requirements of the EC Directives 72/23, 89/392 and 89/336. The following standards were used to determine compliance with the Directives: EN 292, EN 294, EN 811, EN 55014, EN 55104 and EN 60335-1.
| SOUND | VIBRATION | |
| 75 dBOperator | 71dBAt 3m | .5 m/s ^2 At Operators Handle |
| Tests were conducted on 09/18/00 with calibrated sound and vibration equipment under the conditions noted below:General Condition: Indoors Wind: . 0 km/hrTemperature: 25°C Humidity: 70%Barometric Pressure: 29.5 | ||
Jeff Bollach
Jeff Pollack, Standards Engineer
10/24/01
Date
Form: EC050
Table of Contents
IMPORTANT SAFETY INSTRUCTIONS....1
Inspection 2
Electrical....2
115 Volt 2
240 Volt 2
Grounding Instructions....2
User Maintenance Instructions .... 3
Cloth Bag & Hose Assembly 3
Cord Storage 3
Operation and Filter Care Instructions 4
Tank/Filter Set-Up Procedure 4
Procedures In Removing Contaminated Filters and Cleaning of Contaminated Tank 4
Changing The Black Foam Prefilter 5
Filter Assembly 6
Changing Of Prefilters 6
Exploded Views 7
Lid Assembly 7
Lid Assembly BOM 8
Cloth Bag Assembly 10
Tools and Accessories 11
Minuteman International Made Simple Commercial Limited Warranty 12
FOR COMMERCIAL USE ONLY IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING
DANGER! - THIS VACUUM IS FOR PICK UP OF PARTICULATE MATERIAL ONLY.
NOT FOR VAPOR RECOVERY.
WARNING - To reduce the risk of fire, electric shock, or injury:
- Do not return to manufacturer for repair.
- Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing.
- To avoid electrical shock, do not expose to rain, store indoors.
WARNING:
To reduce the risk of electrical shock - Do not use on wet surfaces. Do not expose to rain. Store indoors.
- Do not allow to be used as a toy. Close attention is necessary when used by or near children.
- Use only as described in this manual. Use only manufacturer's recommended attachments.
- Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
- Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
- Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
- Do not handle plug or appliance with wet hands.
- Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
- Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
- Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
- Do not use without dustbag and/or filters in place.
- Turn off all controls before unplugging.
- Use extra care when cleaning on stairs.
- Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
- Connect to a properly grounded outlet only. See grounding instructions.
SAVE THESE INSTRUCTIONS
Inspection
Carefully unpack and inspect your machine for shipping damage. Each unit is tested and thoroughly inspected before shipment, and any damage is the responsibility of the delivery carrier who should be notified immediately.
Electrical - 115 Volt
This machine is designed to operate on a standard 15 amp. 115 volt, 60 hz, AC circuit. Voltages below 105 volts AC or above 125 volts AC could cause serious damage to the motor.
Electrical - 240 Volt
This machine is designed to operate on a standard 10 amp. 230 volt, 50 Hz, AC circuit.
WARNING
Electric motors can cause explosions when operated near explosive materials or vapors. Do not operate this machine near flammable materials such as solvents, thinners, fuels, grain dust, etc.
Grounding Instructions
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance — if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This machine is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in Sketch A. Make sure that the machine is connected to an outlet having the same configuration as the plug. No adapter should be used with this appliance.

WARNING
This vacuum may contain potentially hazardous dust depending on its application. Special handling of contaminated disposal bags and filters is recommended. Disposal must be in compliance with local EPA regulations
User Maintenance Instructions
All service and repair should be performed by qualified vacuum service representative or electrician. No user serviceable components are employed in the electrical vacuum lid head assembly. No lubrication of the motor is required.
Cloth Bag & Hose Assembly
Cloth bag and hose assembly are user maintenance items and can be replaced when worn out. For optimum performance, empty and clean filter bag regularly. A clogged and dirty bag restricts the flow of air and results in reduced vacuum. The hose assembly can be maintained by wiping off with a dampened cloth of mild liquid soap and water, then allowed to dry.
Cord Storage
While not in use storage can be accomplished by winding cord around motor lid assembly. Cord should be completely unwound from lid assembly during operation.
- Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return to service center.
- Do not pull or carry by cord, use cord as handle, close a door on cord, or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
- Do not unplug by pulling cord. To unplug, grasp the plug, not the cord.
- Do not handle plug or appliance with wet hands.
- Always unplug the machine when removing the motor head off the tank. This equipment should be stored indoors and not exposed to rain.
Always unplug the machine when removing the motor head off the tank. This equipment should be stored indoors and not exposed to rain.
Operation and Filter Care Instructions
The Minuteman Bio-Haz Vacuum has been specifically designed to clean up hazardous dust of all types. Special filters reduce the incidence of airborne dust that would be created by any other method of cleaning.
- During the removal of hazardous dust, do not sweep, scoop, shovel, or in any manner handle other than by vacuuming.
- Do not at any time attempt to bypass, remove, substitute or by any other means change the filters used in this vacuum.
- Use only approved Minuteman Bio-Haz Vacuum filters and filter bags.
- Before attempting to use and before cleaning, be certain that you fully understand the instructions given for the setting up or cleaning/changing of filters of this vacuum.
Each facility has its own individual and unique cleaning problems, it is suggested that you use the following:
Tank/Filter Set-Up Procedure (Refer to Filter Assembly)
- Fully open the plastic bag and place it down into the tank on the underside of the intake tube as shown.
- Take the paper bag that has the cardboard collar attached and open it up by gently pulling the folds apart.
- You will notice two creases on the top side of the collar; carefully bend the ends down (toward) the bag.
- Insert this bag into the tank and push it to the bottom, taking care not to snag the plastic bag.
- Locate the cardboard collar around the intake tube and gently work it up past the raised ring that runs around the tube.
- Push the plastic bag down past the paper bag; position it about 1/2 to 2/3 down past the top of the bag.
- Starting at the bottom of the cloth filter, slip the paper filter protector over the entire cloth filter until the elastic band on the paper filter protector goes around the black plastic frame of the cloth filter.
- Ensure that the inside steel frame that supports the cloth filter is inserted into the tank with the cut out section facing the front of the down tube. Then insert the cloth filter and paper filter protector inside the tank. Be careful not to rip the paper filter protector when pushing the cloth filter with steel frame into the tank.
- Position the lid onto the tank, making sure that the paper filter elastic is inside the cloth filter frame so that the U.L.P.A. filter will go down inside the cloth filter. Make sure that the motor lid is seated onto the ring of the cloth filter frame completely around the tank.
- Snap the lid latches into place.
For proper cleaning of the tank and removal/changing of the filters, see “Procedures in Removing Contaminated Filters and Cleaning of Contaminated Tank.”
Procedures In Removing Contaminated Filters and Cleaning of Contaminated Tank
Always wear a facemask and gloves when conducting this procedure.
- Unplug the machine from the power source.
- Carefully and slowly unlatch the tank latches and remove the vacuum lid only (be sure when you lift up on the lid that the cloth filter stays inside the tank.) Set the lid with U.L.P.A. filter assembly aside.
- Gently remove the cloth and paper filter protector from the tank. Carefully place the paper and cloth filter into a plastic bag. With one hand grab the bottom of the paper filter protector through the plastic bag and with the other hand release the elastic band from around the cloth filter frame. Slide the cloth filter out of the paper bag. Set the cloth filter and frame aside.
- Before closing up the plastic bag with the used paper filter inside, check the prefilter attached to the U.L.P.A. filter for any noticeable dirt. The impact filter should be changed every other time you change the paper filter or if any dirt particles are noticed during inspection. Then the used prefilter can also be put into the plastic bag before sealing up for disposal. See "Changing the Black Foam Prefilter", for more information.
- Carefully surround the paper debris bag with the plastic bag in the bottom of the tank. Pull the opening of the plastic bag securely around the down tube with one hand. This plastic bag will completely encapsulate the debris bag. Push downward on the debris bag on the debris bag's cardboard collar until it slips off of the downtube.
(Continued on next page)
(Cont'd) Procedures In Removing Contaminated Filters and Cleaning of Contaminated Tank
- Slowly pull the top of the plastic bag upwards. When you have the plastic bag fully extended upwards, slowly squeeze the plastic bag closed to avoid trapping excess air. Twist the plastic bag until enough plastic can be tied into a knot.
- Lift the bag out of the tank and dispose of it properly.
- Before inserting another plastic bag and paper debris bag, take a wet paper towel and wipe out the inside of the tank of any dirt contaminate. Put this inside the plastic bag along with the used paper filter protector and prefilter. This plastic bag should also be twisted shut, tied into a knot and disposed of properly.
- To help prolong the life of the U.L.P.A. filter, a spare cloth filter should be interchanged with the existing cloth filter. Vacuum out when there is any noticeable dirt or soil. The cloth bag can also be sprayed with a garden hose from the inside out to remove any soil. Make sure that the cloth filter is completely dry before reinstalling it into the vacuum.
- CAUTION: Any hazardous materials must be disposed of properly. Never throw contaminated debris into you usual trash receptacle. Place debris in a plastic bag or can marked "Hazardous Materials" and take to a hazardous waste handler.
- For proper assembly of new filters, see "Tank Filter Set Up Procedures."
Changing The Black Foam Prefilter
The prefilter should be changed, using all of the precautions previously mentioned.
The prefilter should be changed when any of the following takes place:
- Anytime there is an indication of a filter tear during normal operation of the unit. This tear could be in any of the filters used.
a. paper dust containment bag
b. paper bag protector
c. cloth filter bag
These tears would show up during the tank clean-out procedure, or....
- Every other tank clean-out period. To change the prefilter, do the following before you do Step #3 of the normal clean-out procedure.
a. Wipe down all of the exposed surfaces on the underside of the removed lid, using the dampened wiping cloth
b. Remove the prefilter from the high efficiency filter. Be careful so as not to damage or puncture the U.L.P.A. media used in the final filter. Do not attempt to clean the prefilter in any way; dispose of by placing it into the tank you are now in the process of cleaning. DO NOT USE ANY TOOLS TO REMOVE THE PREFILTER.
d. Before proceeding any further in cleaning the tank, first place a new prefilter (one only) onto the U.L.P.A. filter
Filter Assembly


In order to prolong the efficiency and performance of the critical filter it is recommended that each pre-filter, debris bag and paper filter protector be changed every time the debris bag is full. Change the foam prefilter every second time or if a bag breaks or tears. Follow the manual for bag replacement.
Whenever the vacuum is in operation or being emptied, the operator should be wearing protective clothing and respirator for protection.
All used pre-filters and debris bags should be handled and disposed of in accordance with federal E.P.A. regulations.
Exploded Views
Lid Assembly
Minuteman
Excellence Meets Clean

Lid Assembly BOM

ITEM PART NO. REQ'D DESCRIPTION
1 110030PKG 1 PREFILTER SLEEVE, 829/839, PKG OF 6
2 110029 1 FILTER-ULPA, X829 SERIES
3 290017 2 MOULDED VAC MOTOR GASKET
4 290031 1 LID GSKT 294/6 DIECUT
5 290032 1 DOME SEAL 296
6 380001-4 1 MOTOR-VAC BYPASS 120V (ECM) W/ WIRES
6A 380054 1 MOTOR-VAC 240V 6125-00
7 380005 2 CARBON BRUSH REPLACEMENT (ECM)
8 380064 1 RING, FOAM
9 381020 1 CORD-16GA-3 50FT MED GREY
9A 740600 1 CORD-EUROPEAN F3 G1.5MM 50FT B
10 390062 1 O-RING-VALVE SEAT BODY
11 460001 1 HANDLE BASIC 460 BLACK
12 460100 1 MOTOR LID COVER- BLACK
13 460101 1 MOTOR CAP- BLACK
14 460104 1 MOTOR HOLDOWN 829SERIES
15 460124 1 MOTOR PAN ASY 829SERIES
16 700287 1 GROMMET
17 710307 2 SCR-MC 6-32 X 1 ZINC
18 711124 1 SCR-ST-B 10 X .37 NI
19 711125 3 SCR-ST-B 10 X .50 NI
20 711160 9 SCR-HI/LO #10 X 5/8 ZINC
21 711161 8 SCR-HI/LO #10 X 3/4 ZINC
22 711162 2 SCR-HI/LO #10 X 1 1/2 ZINC
23 711301 2 NUT-HEX 6-32 ST PL
24 711502 2 WSR-FLT #8
25 711551 2 WSR-INT LOCK #6
26 711553 1 WSR-INT LOCK #10
27 715009 1 DECAL-WARNING TO AVOID
28 715029 1 DECAL-NAME PLATE SERIAL
29 715501 1 DECAL-MADE IN USA
30 715530 1 DECAL-DANGER MUST WEAR
31 715531 1 DECAL-DANGER DO NOT RETURN
32 715532 1 DECAL-DANGER THIS VACUUM IS
33 740029 1 SWITCH-SPST PB
34 740938 1 16G BLACK 14.00" B=12
34A 740416 1 14G BLACK 13.00" B=2
35 809754 1 SWITCH-ROCKER
36 828893 1 RIVET-BAP KTR64BX
37 833237 1 STRAIN RELIEF-W/NUT
*** 829118 1 LID ASY COMP W/ULPA FTR
*** 829241 1 LID ASY COMP ULPA 230V
To install pre-filter simply slide black foam sleeve over ULPA canister
WARNING
This vacuum may contain potentially hazardous dust depending on its application. Special handling of contaminated disposal bags and filters is recommended. Disposal must be in compliance with local EPA regulations.

BILL OF MATERIAL - 290010-3
ITEM PART NO. REQ'D DESCRIPTION
1 390087 1 GASKET DIECUT VNN
2 390110 1 INTAKE ASSEMBLY ALUMINUM
3 460109 1 TANK 6GAL LOW INTAKE
4 460114 2 LATCH POLY TNK
5 460115 1 DOLLY, PLAST VAC TNK BLK
6 460118 4 CASTER
7 711160 4 SCR-HI/LO #10 X 5/8 ZINC
8 712320 2 WSR .22 X .45 X .04 NYL
9 712638 2 NUT HEX 10-24 SS NYLOC
10 712824 2 SCR-THUMB 10-24 X .75 STL ZINC
11 715531 1 DECAL-DANGER DO NOT RETURN
12 715532 1 DECAL-DANGER THIS VACUUM IS
13 750118 1 INTAKE ASSY TUBE 4/6 GAL
14 828893 4 RIVET

Item Part No. Qty. Description
1 760244MCH 1 Molded Bag Ring
2 760406PLT 1 Bag Frame
3 805040 1 Cloth Bag Only, 6G
4 712764 4 SS Washer #10
5 711909 4 Pop Rivet
6 800056 1 Bag Asy Complete
Part No. Description
| A | ![]() | 800083 3" Rd Dust Brush Complete133249 Dust Brush HSG 3"800084 Bristle Insert 3"808023 Adapter |
| B | ![]() | 800035 12" Crev Tool Complete |
| C | ![]() | 290000 Wand Asy 1-1/2", Complete290001290002 |
| D | ![]() | 800317 Hose Assy. 1-1/2" x10'390014801044 |
| E | ![]() | 829561 11" Floor & Rug Tool |
| F | ![]() | 800124 5" Tool Only Without Insert |
| G | ![]() | 384003PKG Disposable Paper ReplacementFilter BagsPackage of 10 |
| H | ![]() | 110030PKG Pre-Fliter SleevePackage of 6 |
| I | ![]() | 761177PKG Disposable Paper Filter ProtectorPackage of 10 |
| J | ![]() | 802206PKG Bio Hazard Plastic Bag2 mil.Package of 10 |
Minuteman International Made Simple Commercial Limited Warranty
Minuteman International, Inc. warrants to the original purchaser/user that the product is free from defects in workmanship and materials under normal use. Minuteman will, at its option, repair or replace without charge, parts that fail under normal use and service when operated and maintained in accordance with the applicable operation and instruction manuals. All warranty claims must be submitted through and approved by factory authorized repair stations.
This warranty does not apply to normal wear, or to items whose life is dependent on their use and care, such as belts, cords, switches, hoses, rubber parts, electrical motor components or adjustments. Parts not manufactured by Minuteman are covered by and subject to the warranties and/or guarantees of their manufacturers. Please contact Minuteman for procedures in warranty claims against these manufacturers.
Special warning to purchaser -- Use of replacement filters and/or prefilters not manufactured by Minuteman or its designated licensees, will void all warranties expressed or implied. A potential health hazard exits without original equipment replacement.
All warranted items become the sole property of Minuteman or its original manufacturer, whichever the case may be.
Minuteman disclaims any implied warranty, including the warranty of merchantability and the warranty of fitness for a particular purpose. Minuteman assumes no responsibility for any special, incidental or consequential damages.
This limited warranty is applicable only in the U.S.A. and Canada, and is extended only to the original user/purchaser of this product. Customers outside the U.S.A. and Canada should contact their local distributor for export warranty policies. Minuteman is not responsible for costs or repairs performed by persons other than those specifically authorized by Minuteman. This warranty does not apply to damage from transportation, alterations by unauthorized persons, misuse or abuse of the equipment, use of non-compatible chemicals, or damage to property, or loss of income due to malfunctions of the product.
If a difficulty develops with this machine, you should contact the dealer from whom it was purchased.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above exclusions and limitations may not apply to you.
Cord Electric Group...... Three years parts, two years labor, ninety days travel (Not to exceed two hours)
Exceptions...... Port-A-Scrub, one year parts, six months labor MPV 13, one year parts MPV 14 and 18, two years parts, one year labor RapidAir blower, one year parts, one year labor Explosion-Proof Vacuum, one year parts, one year labor Pneumatic Vacuums, three years parts, one year labor
Battery Operated Group.....Three years parts, two years labor, ninety days travel (Not to exceed two hours) Exceptions.....Sweepers, one year parts, one year labor, ninety days travel (Not to exceed two hours)
Internal Combustion Group....One year parts, one year labor, ninety day travel (Not to exceed two hours)
Replacement Parts......Ninety days Batteries......0-3 months replacement, 4-12 months pro-rate Polypropylene Plastic Tanks...Ten years, no additional labor