| Product Type | Bathroom Heater 3-in-1 (Heat, Fan, Light) |
| Model Numbers | MBHC2LW, MBHC2LS |
| Rated Voltage | 230V-240V |
| Rated Frequency | 50 Hz |
| Rated Power | 540-590 W |
| Dimensions (Fascia) | 390 mm x 220 mm (approx.) |
| Weight | Approx. 2.0 kg |
| Heating Element | 2 x Infrared Lamps (E27, 275W each) |
| Lighting Lamp | 1 x CFL (E27, 13W, MARTEC Code: MRL13W) |
| Exhaust Fan | Yes, integrated with ducting (Ø100mm, max duct length 1.5m) |
| Installation Type | Ceiling mount (flat ceilings only) |
| Minimum Ceiling Height | 2.3 m from floor to lamps |
| Minimum Clearance to Wall | 250 mm from edges |
| Minimum Clearance to Rooftop | 220 mm above ceiling |
| Safety Features | All-pole disconnection switch (3mm contact gap), grounded, IP? (bathroom rated) |
| Controls | Wall-mounted switch panel (Heat, Fan, Light) |
| Maintenance | Wipe with soft cloth and neutral detergent; replace lamps as specified |
| Warranty | 2 years (excluding lamps) |
| Accessories Included | Operation unit, infrared lamps (2), light lamp (1), ventiduct kit (1.5m), duct clip, switch, warranty card |
| Standards Compliance | AS/NZS3000:2000 (or latest), Australian Consumer Law |
Frequently Asked Questions - Contour 2 Martec
User questions about Contour 2 Martec
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Heating in PDF format for free! Find your manual Contour 2 - Martec and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Contour 2 by Martec.
USER MANUAL Contour 2 Martec
INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE
MARTEC® BATH ROOM HEATER 3 IN 1 HEAT, FAN, LIGHT
Dear customers
Thank you for selecting Martec Bathroom Heater 3 in 1. Please read all instructions before commencing installation.
IMPORTANT: This unit must be installed to comply with the appropriate council regulations and the Australia and New Zealand wiring rules AS/NZS3000:2000 or lastest edition thereof.
The main supply and interconnecting cables required for installation of this unit are not included.
WARNING - INSTALLATION ONLY TO BE BY QUALIFIED PERSONS
-
Use this heater only as described in this manual. The manufacturer does not recommend any other use as this may cause fire, electric shock, or injury to persons. If you have questions, contact the manufacture or local agent.
-
All wiring must be carried out by a Licensed Electrician in accordance with all applicable codes and standards.
-
Make sure the power is off before the installation.
-
When cutting into the wall, do not damage electrical wiring and other hidden utilities.
-
The heater must be properly grounded
-
The lamps are hot when in use. Do not touch the infrared lamps with any part of your body when in use.
-
For the purpose of avoiding any dangerous gas leaking into your bathroom, the ventiduct of the heater must not be laid together with the ventiduct of air-fueled water heater or other open-fire appliances into the same flue.
-
The disconnection may be achieved by having the plug accessible or by incorporating a switch in the fixed wiring in accordance with the wiring rules. The heater must be isolated from the power by means of a plug or all-pole disconnection switch with a contact separation of at least 3mm in each pole.
-
The power cable must stand a minimum 5A load
-
The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
-
Children should be supervised to ensure that they do not play with the appliance.
-
The heater is to be installed so that switches and other controls cannot be touched by a person in the bath or shower.
-
The appliance shall, under no circumstances, be covered with insulating material or similar material.
-
Regulations concerning the discharge of air have to be fulfilled.
-
Joists, beams and rafters shall not be cut or notched to install the appliance.
IMPORTANT CONSIDERATIONS BEFORE INSTALLING
A few minutes of planning can make a big difference to the installation time and also to your satisfaction with the function of the unit.
-
The unit should not be installed directly above a shower or bathtub. The unit must not be installed in a position where water may splash onto the lamps.
-
The unit must not be installed beneath a fixed socket.
-
The unit is designed for installation in flat ceilings only. Do not mount it on a sloping ceiling or a vertical wall.
-
The infrared lamps are most effective when you are standing directly beneath them, so generally the unit would be mounted a place where you would stand to dry yourself.
-
For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be able to enter the room. Generally, this air would be drawn under the door, or through a slightly open window. If the room is airtight, the fan will function poorly.
-
Before commencing any cutting, check in the ceiling space that there are no obstructions such as ceiling joists and that there is sufficient height clearance for the housing. Check that the electrical wiring can be routed from the wall switches to the mounting location.
INSTALLATION
1. Cutting a vent
Locate a vent position (above the ceiling) on the wall, and then cut a 105mm diameter hole at this very position.
2. Ducting
Put one end of the 100mm diameter ventiduct into the vent hole and seal space around the hole using a suitable sealant and cowling where necessary.
Note: Since the length of each duct is 1.5m , make sure that from the centre of installation position there should be a distance within 1.5m to the outside vent.

3. Locating the heater
For the purpose of obtaining best heating effect, from the lamps there should be about a 2.3m overall height to ground.
4. Prepare the ceiling
Cut around the attached hole-cutting template and use this template to mark the hole outline on the ceiling.
Make sure a distance between the edges and wall is no less than 250mm . Also from the rooftop should be a minimum 220mm height to the ceiling.
5. Remove the Fascia
Remove all lamps from the heater. Unclip the internal fascia-retaining springs inside the housing. Remove the fascia.
Note: Do not force when removing the heating lamps.

6.Wiring
Connect one end of the interconnecting wire with the switch panel, and then drag the other end power cable out of the hole on ceiling. Open the terminal block cover on the housing and make connection as the wiring diagram instructs, then reposition the terminal block cover. Tuck the redundant wire into the ceiling so as to leave the housing enough room to fix in.
Note: Ensure that the power is turned off before carrying out any work on electrical installations.


Read and save these instructions!
Please use this card as hole cutting template 390mm×220mm.
INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE
- Fit the in-house end of the duct to the fan outlet, and fixt the end with duct clip.
Note: Keep the route as straight as possible.
8. Position the housing into the hole
Choose and optimal direction to put the housing into the hole in accordance with the position of the fan outlet. Use the two spring clips to fix the housing. Ensure that the unit is held securely by the clips.
Note: Try to keep the redundant wire away from the housing.
9. Final installation
1) Replace the fascia
Replace the fascia and retaining springs.
2) Replace the lamps
Ensure the lamps are tightened
sufficiently to make good electrical
contact. Clean the lamps and fascia.
3) Fix the switch panel to the wall
Note: The switch wiring should be
mounted inside the wall to give the
switch an integrated built in appearance.
If it is necessary to run the wiring on the
outside of the wall, use a suitable
conduit and fixings to properly located
and hold the wiring used.
For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be a to enter the room. In general this air would be drawn from under the door, or through a slightly opened window. If the room is air-tight, the fan will function poorly.
USE
Our bathroom heater uses the infrared heating lamps as a source of heat. It also combines the functions of exhaust and light.
1. Heat
Turn on/off 'HEAT' button.
Each individual infrared lamp has been sprayed 4 times with cold water
to ensure that there are no flaws in the construction.
Note: Do not touch the infrared lamps with any part of your body when in use.
2. Exhaust
Turn on/off 'FAN' button.
The heater can exhaust odour and steam in a quick and efficient way by turning on
the 'FAN' button.
Note: No additional exhaust fan is necessary for the heater itself can exhaust all
odour and steam as needed.
3. Lighting
Turn on/off 'LIGHT' button.
Note: Do not turn on/off the buttons frequently when in use. Shut off power if in long vacany.
MAINTENANCE
1. Clean
1) Shut off power before cleaning.
2) Wipe lamps and fascia with care using a soft cloth soaked with neutral detergent.
Note: Ensure the lamps are cool to touch before handling.
2. Lamp Replacement
1) Check and tighten lamps regularly.
2) Shut off power before replacem
3) Use E27 13W CFL for lighting(MARTEC Code: MRL13W).
4) Use E27 275W infrared lamps for heating(MARTEC Code: MRL275W).
Note: It may affect operation (even cause danger) when lamps, other than the
designated ones, are used.
WARRANTY
The unit is warranted against defects in manufacturing and workmanship for a period of 2 years. The warranty does not extend to lamp globes supplied or installation of the unit or any associated wiring or any damage caused by installation or wiring.
The installation must be conducted by a licensed electrician and a suitable certificate of safety is to be issued by the electrician who installed the unit. Warranty claims will be voided unless a certificate of safety can be produced when required, prior to service or repair.
This warranty does not cover damages or loss caused by:
1) Heat or light lamps.
2) Any consequential losses arising from incorrect installation or operation or maintenance of this product.
3) Any consequential losses arising from incorrect wiring of this product.
4) Any modifications or changes made to the unit, other than those recommended by the Manufacturer.
ACCC Required Statement
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to Martec replacing the product in home with parts and labour for a major failure. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Martec offers an in home warranty that includes parts and labour so the end consumer is not out of pocket.
MAIN TECHNICAL PARAMETERS
| Model Number | MBHC2LW, MBHC2LS |
| Rated Voltage | 230V-240V |
| Rated Frequency | 50Hz |
| Rated Power | 540- 590W |
LIST OF ACCESSORIES
| Operation unit | 1 piece |
| Infrared lamp (E27) | 2 pieces |
| Light lamp (E27) | 1 piece |
| Installation instruction & hole-cutting template | 1 piece |
| Warranty card | 1 piece |
| Ventiduct kit | 1 set |
| Duct clip | 1 piece |
| Switch | 1 piece |
Fill out the following details and file with the purchase invoice for warranty service.
MODEL NO.:
Purchased from:
Date of purchase:
MARTEC