| Product Type | Automatic Upper Arm Blood Pressure Monitor |
| Model | UA-1020 |
| Brand | A&D |
| Measurement Method | Oscillometric |
| Arm Circumference Range | 22 – 32 cm (standard cuff) |
| Display | LCD digital display |
| Memory | 90 readings with date and time |
| Measurement Range | Pressure: 0 – 300 mmHg, Pulse: 30 – 199 bpm |
| Accuracy | Blood pressure: ±3 mmHg, Pulse: ±5% |
| Power Source | 4 x AAA batteries or AC adapter (optional) |
| Battery Life | Approximately 300 measurements |
| Dimensions | Approx. 150 x 120 x 60 mm (without cuff) |
| Weight | Approx. 350 g (without batteries and cuff) |
| Key Features | Irregular heartbeat detection, WHO classification indicator, average of last 3 readings, auto power off |
| Cuff | Standard cuff (22 – 32 cm), compatible with large cuff (32 – 42 cm, optional) |
| Clinical Validation | Validated according to international protocols (ESH, BHS, AAMI) |
| Cleaning | Wipe with a soft dry cloth; do not use solvents or immerse in water |
| Storage Conditions | -20°C to 60°C, 10% to 95% RH |
| Operating Conditions | 10°C to 40°C, 15% to 90% RH |
| Safety Standards | IEC 60601-1, IEC 60601-1-2 (EMC) |
| Warranty | 2 years (may vary by region) |
| Accessories Included | Cuff, instruction manual, batteries (if supplied) |
Frequently Asked Questions - UA-1020 A&D
How do I set the date and time on my A&D UA-1020?
Press the SET button to enter date/time setting. Use the MEM button to adjust values and SET to confirm. Refer to the manual for detailed steps.
What does the irregular heartbeat symbol mean?
The irregular heartbeat symbol indicates that an irregular heartbeat was detected during measurement. This is not a diagnosis but a warning; consult your doctor if it appears frequently.
How often should I replace the batteries?
Batteries typically last for about 300 measurements. Replace all four batteries when the low battery indicator appears or the display dims.
Can I use an AC adapter with the UA-1020?
Yes, an optional AC adapter (6V, 600mA) can be used. Ensure it is the correct model specified by A&D to avoid damage.
What is the correct way to apply the cuff?
Wrap the cuff around your upper arm with the tube aligned with the center of your elbow. The bottom edge should be 1-2 cm above the elbow crease. Tighten securely but not too tight.
Why does the device display an error message 'E1' or 'E2'?
Error codes indicate issues like movement during measurement, weak battery, or improper cuff placement. Refer to the manual for specific error meanings and solutions.
How do I view the average of my last three readings?
Press the MEM button to enter memory mode. The average of the last three readings will be displayed automatically.
Is the A&D UA-1020 clinically validated?
Yes, it has been clinically validated according to international standards (ESH, BHS, AAMI) for accuracy.
Can I clean the cuff with water?
No, do not immerse the cuff in water. Clean it with a soft, damp cloth and mild soap if needed. Air dry thoroughly before use.
What should I do if the device won't turn on?
First, check the batteries or connect the AC adapter. Ensure batteries are inserted correctly with correct polarity. If issue persists, contact A&D support.