Keystone

KSTAW12CE - Air conditioner Keystone - Free user manual and instructions

Find the device manual for free KSTAW12CE Keystone in PDF.

📄 5 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Keystone KSTAW12CE - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeWindow Air Conditioner
ModelKSTAW12CE
BrandKeystone
Cooling Capacity (BTU/h)12,000
Appropriate Room SizeUp to 550 sq ft (est.)
Window Opening Width23 to 36 inches (584-914 mm)
Window Opening Minimum Height13 inches (330 mm)
Unit Height15-1/2 inches (394 mm)
Power Supply115V / 60Hz (est.)
Power Cord3-prong grounded plug
InstallationStandard double hung window
Air Direction ControlAdjustable louvers
FilterWashable foam filter
Condensate DrainageRear drain holes, tilted back for proper drainage
Weight (approx.)70 lbs (32 kg)
Safety FeaturesGround prong, sash lock, frame lock
Required ToolsScrewdriver, level, ruler, scissors
Included AccessoriesTop rail, accordion panels, frame lock, sash lock, weather stripping, screws
Energy Star ModelYes (includes R1 hardware and weather stripping)

Frequently Asked Questions - KSTAW12CE Keystone

What is the cooling capacity of the Keystone KSTAW12CE?
The Keystone KSTAW12CE is a 12,000 BTU/h window air conditioner, suitable for cooling rooms up to approximately 550 square feet.
What window size is required for installation?
The air conditioner requires a standard double hung window with an opening width between 23 and 36 inches (584-914 mm) and a minimum vertical opening of 13 inches (330 mm).
Does the unit require a dedicated electrical outlet?
It is recommended to plug the unit into a dedicated 115V/60Hz grounded outlet. Do not use an extension cord. The power cord has a three-prong grounded plug; never cut or remove the ground prong.
How should the air conditioner be tilted for proper drainage?
The unit must be tilted downward toward the outside by about 3/4 to 1-1/8 inches (depending on model) to ensure proper condensate drainage. This tilt is achieved by the offset top rail and side panels.
Can I install this air conditioner if I have storm windows?
If a storm window blocks the installation, you may need to add wood blocking to raise the unit or remove the storm window. Ensure drain holes in the storm window are not sealed to allow water drainage.
How do I clean or maintain the air filter?
The filter should be checked every two weeks. Remove the front grille, take out the filter, and wash it with warm water and mild detergent. Allow to dry completely before reinstalling.
What should I do if the air conditioner freezes up?
Ice buildup can occur due to restricted airflow or low outdoor temperatures. Turn the unit off and let the ice melt. Clean or replace the filter, and ensure the room temperature is above 60°F (16°C) when using cooling mode.
How do I remove the air conditioner at the end of summer?
Turn off and unplug the unit. Remove the sash lock and screws. Slide side panels inward, then carefully lift the unit out of the window. Store the unit and all parts in the original carton in a dry place.
What is the R1 hardware and how do I install it?
R1 hardware is an insulation panel for Energy Star models that reduces air leaks. Measure the inner width of the side curtain, cut the panel 1/8 inch shorter, and slide it into the curtain with the patterned side facing indoors. Repeat on the other side.
Why does water drip from the overflow drain hole?
If water drips from the overflow drain during normal operation, the unit is not tilted enough toward the outside. Adjust the slope so the rear is lower than the front by the recommended height difference.

User questions about KSTAW12CE Keystone

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual KSTAW12CE - Keystone and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. KSTAW12CE by Keystone.

USER MANUAL KSTAW12CE Keystone

Read these instructions completely and carefully.

IMPORTANT- Save these instructions for local inspector s use.

IMPORTANT- Observe all governing codes and ordianaces.

Note to Installer- Be sure to leave instructions with the Consumer.

Note to Consumer- Keep these instructions for futrue reference.

Skill level- Installatio of this appliance requires basic mechanical skills.

Completion time- Approximately 1 hour

We recommend that two people install this product.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this conditioner.

Keystone KSTAW12CE - 1

WINDOW REQUIREMENTS

Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches(584mm to 914mm)

OFFSET EXTERIOR WALL INNER. WINDOW SILL INTERIOR WALL 23° to 36" 584 mm to 914mm H Wooden Windows

Model H6000~8000Btu/h10000~12000Btu/h
14"(356mm)15-1/2"(394mm)

Table 1

Keystone KSTAW12CE - WINDOW REQUIREMENTS - 2

CAUTION

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power co of the air conditioner.

Aluminum house wiring may present special problems-consult a qualified electrician. these

When handling unit, be careful to avoid cuts sharp metal edges and aluminum fins on front rear coils.

TOOLS YOU WILL NEED
Keystone KSTAW12CE - CAUTION - 1

natural_image Diagram of a screwdriver with a magnified view of the tip (no text or symbols)

Screwdriver

Keystone KSTAW12CE - CAUTION - 2
Level

TOOLS YOU MAY USE
Keystone KSTAW12CE - CAUTION - 3
Screwdriver

Keystone KSTAW12CE - CAUTION - 4
Pencil

Keystone KSTAW12CE - CAUTION - 5

Keystone KSTAW12CE - CAUTION - 6
Ruler or tape measure
Scissors or knife

Keystone KSTAW12CE - CAUTION - 7

NOTE:

Save Carton and these Installation Instruction for future reference. The carton is the best to store unit during winter, or when not in

Keystone KSTAW12CE - NOTE: - 1

PREPARE THE WINDOW

Lower sash must open sufficiently to allow a clear vertical opening of 13 inches (330mm). Side louvers and the rear of the AC must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or garage.

Mounting Hardware
Keystone KSTAW12CE - PREPARE THE WINDOW - 1

Keystone KSTAW12CE - PREPARE THE WINDOW - 2

Keystone KSTAW12CE - PREPARE THE WINDOW - 3

Keystone KSTAW12CE - PREPARE THE WINDOW - 4

Keystone KSTAW12CE - PREPARE THE WINDOW - 5

3/4"(or 1/2)" Screws

(7)

Lock Frame

(2)

Sash Lock

(1)

Window sash Weather seal foam stripping

(1)

(10 ^ 3/4 ^ 1/12 ^* )

(5)

NOET: Weather stripping is only for Energy star models.

Keystone KSTAW12CE - PREPARE THE WINDOW - 6

PREPARE AIR CONDITIONER

A: Remove the air conditioner from the carton and place on a flat surface.
B: Remove top rail and R1 hardware (R1 hardware only for Energy star models) from the rear of the packaging material as shown in Fig. A.

Top Rail and R1 Hardware
Keystone KSTAW12CE - PREPARE AIR CONDITIONER - 1

3/8 Screws

(4)

Keystone KSTAW12CE - PREPARE AIR CONDITIONER - 2

Top Rail

(1)

Keystone KSTAW12CE - PREPARE AIR CONDITIONER - 3

R1 hardware

(2)

Fig.A Top Rail R1 hardware Packaging

C: Align the hole in the top rail with those in the top of the unit as shown in Fig.B

Keystone KSTAW12CE - PREPARE AIR CONDITIONER - 5

natural_image Technical diagram of a roof drainage system with ventilation grilles and ventilation ducts (no text or labels)

D: Secure the top rail to the unit with the 3/8 Screws as shown in Fig.C.

Keystone KSTAW12CE - PREPARE AIR CONDITIONER - 6

natural_image Technical line drawing of a mechanical device with mounting holes and internal components (no text or symbols)

NOTE: For safety reasons, all four(4) screws MUST be securely fastened.

Keystone KSTAW12CE - PREPARE AIR CONDITIONER - 7

INSTALL THE ACCORDION PANELS

NOTE: Top rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of (5/16). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained.

Keystone KSTAW12CE - INSTALL THE ACCORDION PANELS - 1

natural_image Pure technical diagram of a vertical structural component with internal parallel elements, no text or symbols present

A. Place unit on floor, a bench or a table. Hold the Accordion Panel in one hand and gently pull back the center to free the open end. See Fig.1

Fig.1

B. Slide the free ehd " " section of the panel into the cabinet as shown in Fig. 2. Slide the down. Be sure to leave enough space to slip top and bottom of the frame into the rails on cabinet.

" "section I

Fig.2

C. Once the panel has been installed on the cabinet, make sure it sits securely inside frame channel by making slight adjustments. Slide the top and bottom ends of the frame top and bottom rails of the cabinet. Fig.3.

Top Rail Bottom Rail

Fig.3

D. Slide the panel all the way in and repeat other side.

Fig.4 Top left Top Rail Top right Bottom Rail

NOTE: If storm window blocks AC, see Fig. 11.

Keystone KSTAW12CE - INSTALL THE ACCORDION PANELS - 5

SECURE THE ACCORDION PANE LS

The Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottle of the air conditioner frame is against the window sill (Fig.5). Carefully close the window behind the to rail of the unit.

Measure from the cab INSIDE OUTSIDE Wooden Windows

H: About 3/4" to 1" (for 5 to 8K); H: About 1" to 1³/l₈" (for 10 to 12K);

Fig.5

NOTE: Check that air conditioner is tilted back above H (Fig.5)(tilted about ^ 3 to 4 downward to the outside proper installation, condensate should not drain from the overflow drain hole during normal use, correct the slope otherwise.

B. Extend the side panels out against the window frame (Fig.6).

(Fig.6). window frame Fig.6

Keystone KSTAW12CE - SECURE THE ACCORDION PANE LS - 3

INSTALL SUPPORT BRACKET

on AtTrace the frame lock between the frame extensions and the window sill as shown(Fig.7). Drive 3 /" 4 (19mm) of 2"(12.7mm) locking screws through the frame lock and into the sill .

NOTE: To prevent window sill from splitting, drill 1 / 8" (3mm) pilot holes before driving screws.

Keystone KSTAW12CE - INSTALL SUPPORT BRACKET - 1

natural_image Line drawing of a hand holding a tool near a window frame, with an inset showing a small mechanical component (no text or symbols)

B. Drive 31/42" ((192m7m)m) locking screws through frame holes into window sash (Fig.8).

Keystone KSTAW12CE - INSTALL SUPPORT BRACKET - 2

natural_image Line drawing of a front view of an air conditioner unit with cooling fins and ventilation grilles (no text or symbols)

Fig.8

C. To secure lower sash in place, attach right angle sash lock with 3/4" (19mm) or 125 (new7asm) shown(Fig.9).

Keystone KSTAW12CE - INSTALL SUPPORT BRACKET - 3

natural_image Line drawing of a hand holding a tool near a vertical structure (no text or symbols)

Fig.9

D. Cut Windows ash shell foam space between the upper and lower sashes (Fig.10).

FOAM SEAL Fig.10

Keystone KSTAW12CE - INSTALL SUPPORT BRACKET - 5

INSTALL R1 HARDWARE (only be applicable to Energy star models)

In order to minimize air leaks and ensure optimal insulation, it is necessary to install the included R1 hardware to the side curtain. Follow the instructions below.

Step 1. After the unit is installed to the window, measure the inner width of the side curtain as shown (Fig.11).

Step 2. Remark a line on the provide R1 insulation panel according to a length 1/8 (3mm) less than the measured width in step 1, then cut the R1 insulation panel along the line (Fig.12).

Keystone KSTAW12CE - INSTALL R1 HARDWARE (only be applicable to Energy star models) - 1

natural_image Technical line drawing of an air conditioner unit with internal panel and side view showing measurement scale (no text or symbols)

Measure the inner width of the side curtain

Fig.11
or

Fig.12

Step 3. Slide the R1 insulation panel into the side curtain, the side with pattern should facing the indoor side.(Fig.13).

Keystone KSTAW12CE - INSTALL R1 HARDWARE (only be applicable to Energy star models) - 3

natural_image Diagram of a mechanical device with a downward arrow indicating force or direction (no text or symbols present)

Fig.13

Step 4. Repeat on the other side.

7 INSTALL WEATHER STRIPPING (only be applicable to Energy star models)

In order to minimize air leaks between the room air conditioner and the window opening, trim the weather sttipping with a proper length, peel off the protective backing and plug any gaps if needed (Fig.14).

Keystone KSTAW12CE - INSTALL WEATHER STRIPPING (only be applicable to Energy star models) - 1

natural_image Technical line drawing of a cabinet or air conditioner unit with ventilation grilles and a highlighted internal component (no text or symbols)

Fig.14

If AC is Blocked by Storm Window

Add wood as shown in Fig.15, or remove storm window before air conditioner is installed.

If Storm Window Frame must remain, be sure the drain holes or slots are not caulked or painted shut. Accumulated Rain Water or Condensation must be allowed to drain out.

Removing AC From Window

Turn AC off, and disconnect power cord.

Remove sash seal from between windows, and unscrew safety sash lock.

Remove screws installed through frame and frame-lock.

Remove the R1 Panel and close (slide) side panels into frame.

Keeping a firm grip on air conditioner, raise sash and carefully remove.

Be carefully not to spill any remaining water while lifting unit from window. Store parts WITH air conditioner.

SASH Storm window frame or other obstruction. 1-1/2"min (38 mm) Board thickness as required, for proper pitch to rear, along entire sill. Fasten with nails or screws.

Fig.15

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Keystone

Model : KSTAW12CE

Category : Air conditioner