| Product Type | Water Heater |
| Brand | Beko |
| Model | BWI45S1D-242 |
| Capacity | 45 Liters |
| Dimensions (H x W x D) | 600 x 400 x 400 mm |
| Weight | 20 kg |
| Power Supply | 220-240 V ~ 50 Hz |
| Heating Power | 2000 W |
| Energy Efficiency Class | C |
| Temperature Range | 30°C to 75°C |
| Thermostat Control | Adjustable |
| Safety Features | Overheat protection, Pressure relief valve, Thermal cut-out |
| Material – Inner Tank | Enameled steel |
| Material – Outer Casing | Painted steel |
| Installation | Wall-mounted, vertical |
| Water Connection | 1/2" BSP |
| Pressure Rating | 8 bar |
| Protection Class | IP24 |
| Standby Consumption | 0.5 kWh/24h |
| Included Accessories | Safety valve, mounting brackets, owner's manual |
| Maintenance | Descaling recommended every 6 months |
| Reparability | Replaceable thermostat, heating element (standard parts) |
Frequently Asked Questions - BWI45S1D-242 BEKO
User questions about BWI45S1D-242 BEKO
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Water heater in PDF format for free! Find your manual BWI45S1D-242 - BEKO and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. BWI45S1D-242 by BEKO.
USER MANUAL BWI45S1D-242 BEKO
Electric Water Heater
User Manual

natural_image
Front view of a white appliance with a circular button and indicator lights (no visible text or symbols)BWI45S1D-242
EN | VN
beko
Please read this user manual first!
Dear Customers,
Thank you for selecting an Beko product. We hope that you get the best results from your product which has been manufactured with high quality and state-of-the-art technology. The refore, please read this entire user manual and all other accompanying documents carefully before using the product and keep it as a reference for future use. If you handover the product to someone else, give the user manual as well. Follow all warnings and information in the user manual.
Meanings of the symbols
Following symbols are used in the various section of this manual:
| i | Important information and useful hints about usage. |
| WARNING:Warnings for dangerous situations concerning the safety of life and property. | |
| Warning for electric shock. | |
| Warning for fire. |

This product has been produced in environmentally-friendly, state-of-the-art facilities.
Contents
- PARTS IDENTIFICATION......4
- SAFETY INFORMATION....5
- ELECTRICAL LOADING TABLE 6
- HEATER UNIT INSTALLATION 7
- RAIN SHOWER ACCESSORIES INSTALLATION 8
- PLUMBING PROCEDURE....9
- ELECTRICAL INSTALLATION.... 10
- TEST RUN....11
- HANDSHOWER SPRAY 12
- MAINTENANCE.... 13
- WIRING DIAGRAM.... 14
- ELECTRICAL SPECIFICATION.... 15
1 Parts Identification

Note: (*) For both AC/DC PUMP model (**) For AC PUMP model only (***) For DC PUMP model only
- Front Cover 16. Thermostat (Double-Action)
- LED Indicators 17. Heater Tank
- Test/Reset Button 18. PCB Board (Test & Reset)
- Pump Knob (For AC/DC Pump Model) 19. Terminal Block
- Temperature Control Knob 20. Main PCB Board
- Built-in-Filter 21. Water Outlet Connection
- Stop Valve 22. AC Pump
- Flow Regulator Valve 23. TRIAC
- Rail Support 24. Water
- Handshower 25. Reed Switch Assy
- Slider Rail 26. SMPS PCB Board
- Adjustable Shower Holder 27. DC Silent Pump
- SUS Hose 28. Mesh Filter
- Selector Valve 29. Rain Shower Head
- Heater Base 30. PVC Hose
2 Safety Information
WARNING!
2.1 Products manufactured by Beko are safe provided they are installed, used and maintained in good working order in accordance with our instruction and recommendations. Always refer to this manual if you have any doubt.
2.2 The appliance must be earthed. Improper grounding could cause electrical shock.
2.3 If any of the following conditions occur as shown below, immediately switch off the mains and contact the Beko Call Center. Never attempt to repair the unit yourself:
- If the Heater begins to make and odd noise, smell or smoke.
• If ELCB trips and Heater Indicator does not light up.
• Water temperature cannot be controlled. - If the Heater shows signs of a distinct change in performance.
• If water leaks from inside
2.4 For Pump Model, it is highly recommended to connect the Water Inlet Connection to tank storage supply, otherwise it may cause damage to the Pump Motor.
2.5 When the Shower is used by someone such as child, elderly person, sick person and physically handicapped person, the person concerned is kindly requested to pay attention and check the shower temperature by hand from time to time. User is advised to test and adjust the water temperature before using
2.6 During lightning/thunder, switch off the electrical supply to the shower unit in advance to protect the shower unit against possible damage.
2.7 The earth continuity conductor of the electrical installation must be effectively connected to all exposed metal parts of the other appliances and services in the room, which in the heater is to be installed to conform to local regulations and ensure proper earthing/grounding for ELCB to be effective.
2.8 WARNING : Metallic/chromed and conductive control valve shall not be used.
NOTE: When removing the unit from the package, a small amount of water may be found inside. This is normal as the unit is tested during manufacturing process.
CAUTION!
2.9 Installation must be carried out by a qualified personnel and in compliance local authority regulations.
2.10 This Heater must be permanently connected to the direct main supply. A plug and socket is not recommended to be used.
2.11 For the correct size of wire conductor corresponding to different electrical loadings, please refer to Table 1.
2.12 The Heater operates at a minimum water flow rate of 2.0 litre/min and maximum working pressure of 6 bars. for direct connection from the water tank, the Heater must have an installation minimum 1.0m below the water tank.
2.13 The Heater will not function if there is insufficient water flow (min 2.0 litre/min) to trigger the flow switch.
2.14 The built-in-ELCB will automatically cut off the power supply in case there is a current leakage from 15mA.
2.15 The thermostat will automatically cut off the water supply if it has sensed an abnormal rise in water temperature.
3 Electrical Loading Table
Table 1
| Voltage (AC) | Power (kW) | Current (A) | Conductor Size (csa) | On/ Off Switch (A) | Fuse / MCB (A) | ||
| mm^2 | Conduit Cable | Flexible Cable | |||||
| 220V ~ 50/60 Hz | 2.4 | 10.9 | 2.5 | 7 / 0.67mm | 50 / 0.25 mm | 20 | 20 |
| 3.5 | 15.9 | 2.5 | 7 / 0.67mm | 50 / 0.25 mm | 20 | 20 | |
| 4.5 | 20.5 | 2.5 | 7 / 0.67mm | 50 / 0.25 mm | 32 | 32 | |
| 6.0 | 27.3 | 4.0 | 7 / 0.85mm | 56 / 0.30 mm | 32 | 32 | |
| 230V ~ 50/60 Hz | 3.3 | 14.4 | 2.5 | 7 / 0.67mm | 50 / 0.25 mm | 20 | 20 |
| 3.5 | 15.2 | 2.5 | 7 / 0.67mm | 50 / 0.25 mm | 20 | 20 | |
| 240V ~ 50/60 Hz (Malaysia Model) | 3.6 | 15.0 | 4.0 | 7 / 0.85mm | 56 / 0.30 mm | 20 | 20 |
4 Heater Unit Installation

4.1 Select a suitable position in the bathroom.
4.2 Remove the screw (A) at the bottom of the unit. (Fig. 2)
4.3 Remove the Front Cover from the bottom and then lift up the front cover.
4.4 mark 3 screw points of the Heater Base on the wall. The eater position should be 1.5m above the bathroom floor.
5
Rain Shower Accessories Installation



natural_image
Line drawing of a shower shower system with hose and tubing (no text or symbols)
- Do marking for the location of the mounting terminal (bracket) and selector valve (bracket).
- Slot in the assembled upper tube to the lower tube. Install the mounting terminal (bracket holders) and selector valve bracket on the wall.
- Hook the assembled sliding rail to the mounted bracket.
- Tighten all joints and be sure to put the rubber washers to avoid leakage.
6 Plumbing Procedure
CAUTION!
This Instant Hot Shower is a single point system and the 'Water Outlet' can only be fitted to the PVC Hose and Handshower set provided. NO CONTROL VALVE OR FITTING CAN BE FITTED TO THE WATER OUTLET.
6.1 Connect the Stop Valve to the Water Inlet with rubber water. use proper tools to tighten the connection and be careful not to break the plastic nut.
6.2 Connect the incoming water piping to the Stop Valve (1/2" BSP). Make sure to put the Mesh Filter between Stop Valve and incoming water piping.
6.3 If in any case, the Stop Valve is not use or omitted, make sure to put the Mesh Filter between the heater unit inlet pipe and incoming water pipe.
6.4 Turn on the water main to drain out all the plumbing dirt, at the same time fill up the heater tank.
IMPORTANT
For Pump Model, it is highly recommended to connect Water Inlet Connection to tank storage supply, otherwise it may cause damage to the Pump Motor.
6.5 Turn on the water main to drain out all the plumbing dirt, at the same time fill up the heater tank.
THE HEATER TANK MUST BE FILLED UP WITH WATER BEFORE TURNING ON THE ELECTRICITY SUPPLT TO PREVENT ANY DRY BURNT DAMAGE TO THE HEATING ELEMENT.
6.6 Connect the PVC Hose and Handshower tot he outlet of heater, be sure to put in the Ruber Washer.
6.7 Hook the Handshower to the Slider Rail Shower Holder and adjust to your ideal position.
6.8 Check if any water leakage.
6.9 Do not use white tape during installation.
WARNING!
6.10 THE WATER INLET AND OUTLET MUST BE INSTALLED CORRECTLY, OTHERWISE HEATER UNIT WILL NOT FUNCTION.
6.11 DO NOT APPLY PLUMBING CEMENT ON CONNECTION. WHENEVER NECESSARY, USE ONLY THREAD OD SEALING TAPE.
7 Electrical Installation
WARNING!
7.1 This appliance must be earthed.
Improper grounding could cause electrical shock.
7.2 Remember to SWITCH OFF the mains before carrying out any electrical work.
7.3 Refer to TABLE 1 for the correct cable size.
7.4 Use double insulated cable of over 2.5mm ^4 .
7.5 Lead the power cable from MCB to a "ON/OFF" double pole Linked Switch having a contact separation of at least 3mm in all poles outside the bathroom, then lead a cable to the terminal block inside the Heater Unit. (Fig. 4)


PROCEDURE :
7.6 Insert the wall embedded cable through Side Entry 'A' by cutting a hole at the source cord rubber holder and lead the cable to Cable Bracket 'B'. (Fig. 6)
7.7 Connect the cable as following
BROWN or RED - LIVE (L)
BLUE or BLACK - NEUTRAL (N)
GREEN or GREEN/YELLOW - EARTH (⊕)
7.8 Clamp the cable to the correct position. CHECK IF THE WIRING CONNECTION IS CORRECT and replace the cover.
7.9 When putting back the Front Cover, Please take note of the procedure shown below:
- Ensure the position is correct, turn the emperature CControl Knob Insert to OFF position as shown in FIG.A (At the Heater Base)
- Install the Front Cover, turn the Temperature Control Knob to OFF position to align with the VR shaft as shown in Fig.B (At the Front Cover)
7.10 Fix the Temperature Control Knob and screw 'A' (Fig. 2),
7.11 Insert the pump knob as shown in Fig. A.

METHOD OF ALIGNMENT WHEN REPLACING FRONT COVER


8 Test Run
8.1 Turn on the water supply and Stop Valve, the water will flow through the Handshower.
8.2 Switch on the electrical supply. The 3 LED Indicator lights shall run ON/OFF 3 times in sequence to indicate the set are self checking.
8.3 Turn the Temperature Control Knob to 'ON', the Red Indicator light (HEATER) will turn on, hot water will flow out within a few seconds. The More Temperature Control Knob being turned in clockwise direction, the hotter is the shower.
8.4 The shower might not be hot enough even at 'MAX' position if incoming water supply from the mains is too cold or the pressure of the water is too high. In this case, you may adjust the Stop Valve to reduce the water inflow in order to get the desired showering temperature.
8.5 Check the Built-in-ELCB as following :
- Press the "TEST" Button, the Built-in-ELCB should trip and cut off the power supply, all LED Indicators should light off.
- Press the "RESET" Button, the 3 LED Indicator lights shall run ON/OFF 3 times in sequences to indicate self check as in 8.2 above and the Heater unit should resume normal function, the Green LED indicator should light on.
If procedures stated above prevailed, the ELCB is functioning in normal condition.
8.6 The height and direction of Shower Holder are adjustable by realeasing the shower holder knob clockwise and anticlockwise.
8.7 It is unnecessary to turn the Temperature Control Knob to "OFF" position when the Heater is not in use.
8.8 Switch OFF the electricity supply after shower.
8.9 For Pump Models:
Turn on the Pump Control Knob to test on Pump's functionality. If the shower is not hot enough, you may adjust
the pump speed until the desired shower temperature is obtained.
9 Handshower Spray
This innovative adjustable Handshower has 3 different spray patterns (STANDARD, SOOTHE and JUMBO). The patterns are described as following:

Clean the Handshower Head holes by using the soft brush from time to time.
(Recommended once a week)
Note: Take care not to damage the holes of the Handshower Head during cleaning.
10 Maintenance
Read the section'SAFETY INFORMATION' first.
10.1 TEST THE 'ELCB' REGULARLY (This procedure is highly recommended test at least once a month)
Turn on the electricity and water supply, both RED (HEATER) and Green (ELCB) Indicators will light up if the Temperature Control Knob is in 'ON' position. Press the ELCB Test Button, both HEATER and ELCB Indicators should go off. Press the Rest Button to resume the electricity supply.
10.2 CLEAN THE FILTER REGULARLY
Clean the Mesh Filter regularly to prevent blockage. (Fig. 10) Remove the Built-in-Filter by turning its cap anticlockwise. Whenever need to flush the internal stainer with water to remove any trapped sediments. Whenever fixing back the Buily-in Filter, beware of the alignment of Internal Strainer. Use the protruded guideline within Stop Valve to position the Internal Strainer.
WARNING!
10.3 If the HEATER Indicator does not go off when you press the ELCB Test Button, switch OFF the mains supply and contact Beko Call Centre for repair service. NEVER try to repair the unit by yourself.
10.4 CLEANING PRECAUTION!
Do not use thinner, alcohol, petrol or any other organic solutions to clean the set. Use only damped cloth with mild detergent.

natural_image
Diagram of a water heater with control valves and a dial indicator (no text or symbols)

11 Wiring Diagram
WIRING DIAGRAM - DPDT MODEL (FOR VN MODELS ONLY) (NO PUMP / AC PUMP)

flowchart
graph TD
A["Main Supply 220-240V ~ a.c."] --> B["L Live"]
B --> C["Neutral"]
C --> D["E Earth"]
D --> E["Pump Motor"]
E --> F["Flow Switch"]
F --> G["Heater Control"]
G --> H["Speed Control ON/OFF Switch"]
H --> I["Electronic ELCB, 15mA Sensitivity"]
I --> J["Double Action Thermostat"]
J --> K["Auto-Reset Manual-Reset"]
K --> L["Triac T2 T1"]
L --> M["Thermal Inductors"]
M --> N["Heating Element A"]
M --> O["Heating Element B"]
P["(*) For PUMP Model"] --> Q["EP Model"]
Q --> R["Flow Switch"]
R --> S["PUMP"]
S --> T["Reel 1 Relay 1"]
T --> U["Reel 2 Relay 2"]
U --> V["Reel 3 Relay 3"]
V --> W["Double Action Thermostat"]
X["Note: (*) For Pump Model"] --> Y["Note: (*) For Pump Model"]
WIRING DIAGRAM - DPDT MODEL (FOR VN MODELS ONLY) (DC PUMP)

flowchart
graph TD
A["Main Supply 220-240V - a.c."] --> B["L Live"]
A --> C["N Neutral"]
A --> D["E Earth"]
B --> E["Relay 1"]
C --> F["Relay 2"]
E --> G["Relay 3"]
F --> H["PUMP"]
G --> I["Speed Control ON/OFF Switch"]
H --> J["Heater Control ON/OFF Switch"]
I --> K["Triac T2"]
J --> L["Triac T1"]
K --> M["Electronic ELCB, 15mA Sensitivity"]
L --> N["Electronic ELCB, 15mA Sensitivity"]
M --> O[""ESP" Model SMPS PCB ASSY"]
N --> P["Electronic ELCB, 15mA Sensitivity"]
O --> Q["Silent Pump, 48W, 24V d.c."]
P --> R["Heating Element A"]
P --> S["Heating Element B"]
T["Double Action Thermostat"] --> U["Auto-Reset Manual-Reset!"]
V["Flow Switch"] --> W["Therms & Sensors"]
X["Pressure Gauge"] --> Y["Therms & Sensors"]
*Manual Reset (90°C Thermostat)
For Models rated 4.5kW and below, thermostat is manually resetable
12 Electrical Specification
| TYPE | ELECTRONIC POWER CONTROL |
| ELECTRICAL LOADING | 2.4kW to 6.0kW 220V~ a.c. 50/60Hz |
| Min. WATER FLOW RATE | 2 Litre / min |
| Min. INLET WATER PRESSURE | 0.1 Bar (10kPa) |
| Max. INLET WATER PRESSURE | 6.0 Bar (0.6MPa) |
| WATER CONNECTION | 1/2" BSP SINGLE POINT SYSTEM |
| DIMENSIONS | 248 (W) x 367 (H) x 76 (D) mm |
| NET WEIGHT | 2.5 ± 0.5 kg - ELCB, DPDT, DC PUMP |
Note: The specification, actual product's cosmetic design and accessories parts shown are correct at the time printing and may be subjected to change without prior notice.


natural_image
Line drawing of a shower shower system with hose and tubing (no text or symbols)
SƠ ĐỒ ĐI DÂY - MÃU MÁY DPDT (CHỈ DÀNH CHO VIỆT NAM) (KHÔNG BƠM/ΒΟ'M AC)

flowchart
graph TD
A["ELCB điện tử, độ nhạy 15mA"] --> B["Rơ-le 1"]
A --> C["Rơ-le 2"]
A --> D["BÓ diêu nhiệt kép"]
A --> E["Tái khởi động, lụ động"]
A --> F["Tái khởi động, thủ công"]
G["Dây nóng"] --> H["L"]
I["Dây người"] --> J["N"]
K["E"] --> L["E"]
M["Triac T2"] --> N["G"]
O["T1"] --> P["T1"]
Q["Điều khiển tốc độ Công tắc BẮT/TẮT"] --> R["Công tắc BẮT/TẮT"]
S["Điều khiển máy Công tắc BẮT/TẮT"] --> T["Công tắc đóng cháy"]
U["(*) Đồng cơ bơm"] --> V["Bồng cơ bơm"]
W["Mẫu EP"] --> X["(*) Đồng cơ bơm"]
Y["Bộ gia nhiệt A"] --> Z["Bộ gia nhiệt B"]
style A fill:#f9f,stroke:#333
style B fill:#ccf,stroke:#333
style C fill:#ccf,stroke:#333
style D fill:#ccf,stroke:#333
style E fill:#ccf,stroke:#333
style F fill:#ccf,stroke:#333
style G fill:#ccf,stroke:#333
style H fill:#ccf,stroke:#333
style I fill:#ccf,stroke:#333
style J fill:#ccf,stroke:#333
style K fill:#ccf,stroke:#333
style L fill:#ccf,stroke:#333
style M fill:#ccf,stroke:#333
style N fill:#ccf,stroke:#333
style O fill:#ccf,stroke:#333
style P fill:#ccf,stroke:#333
style Q fill:#ccf,stroke:#333
style R fill:#ccf,stroke:#333
style S fill:#ccf,stroke:#333
style T fill:#ccf,stroke:#333
style U fill:#ccf,stroke:#333
style V fill:#ccf,stroke:#333
style W fill:#ccf,stroke:#333
style X fill:#ccf,stroke:#333
style Y fill:#ccf,stroke:#333
style Z fill:#ccf,stroke:#333
SƠ ĐỒ ĐI DÂY - MÃU MÁY DPDT (CHỈ DÀNH CHO VIỆT NAM) (CÓ BƠM DC)