| Product Type | Uninterruptible Power Supply (UPS) |
| Brand | Adj |
| Model | 650-00722 |
| Input Voltage | 120 V AC |
| Output Voltage | 120 V AC |
| Capacity (VA / Watts) | 650 VA / 390 W |
| Battery Type | Sealed Lead-Acid (SLA) |
| Backup Time (Full Load) | Approx. 5 minutes |
| Number of Outlets | 4 (battery backup + surge protection) |
| Surge Protection | Yes |
| Automatic Voltage Regulation (AVR) | Yes |
| Dimensions (H x W x D) | 6.7 x 12.0 x 10.4 in (17 x 30.5 x 26.4 cm) |
| Weight | 9.5 lb (4.3 kg) |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |
| Color | Black |
| Display Type | LED indicators |
| Cooling Fan | Yes, variable speed |
| Warranty | 2 years |
| Safety Certifications | UL, cUL |
| Main Functions | Battery backup, surge protection, AVR, power conditioning |
| Maintenance | Replace battery every 3-5 years |
| Spare Parts Available | Replacement battery |
| Reparability | User-replaceable battery |
Frequently Asked Questions - 650-00722 Adj
User questions about 650-00722 Adj
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Inverter in PDF format for free! Find your manual 650-00722 - Adj and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 650-00722 by Adj.
USER MANUAL 650-00722 Adj
IT IS ADVISED TO READ THIS MANUAL CAREFULLY AND TO KEEP IT!
Thank you for choosing UPS ADJ HOME This UPS (Uninterruptible Power Supply) provides a perfect protection to all feeding devices.
This manual is a guide which enables you to correctly install and use your UPS. This manual includes important SAFETY instructions for the operator, for the UPS correct installation, and gives useful advice on the product and battery maintenance. For any type of problem, please refer to this manual before calling the customer service.
IMPORTANT SAFETY INSTRUCTIONS
- Only properly trained personnel must use the UPS. To ensure correct and safety operations, it is necessary that operators and maintenance personnel observe the general Safety Standards as well as the specific instructions included in this manual.
- Electric Shock risk: do not remove the cover. The UPS contains internal parts at high voltage which are potentially dangerous, capable of causing injury or death by electric shock.
- In the UPS there are no parts which are subject to user's maintenance. Any type of maintenance and repair must be carried out exclusively by a qualified technical personnel authorised. Any type of responsibility is declined if this warning is disregarded.
- It is compulsory to ground the UPS according to Safety Standards in force.
- When the UPS is ON there are risks of electric shock at the output sockets.
- There are risks of electric shock at the output sockets if the unit is connected to the AC utility line.
- Do not lean any object on top of the UPS; do not keep liquids, flammable gases or corrosive substances near the UPS.
• Install the UPS indoors, in a protected, clean and moisture free environment.
INTRODUCTION
UPS ADJ HOME is a Line Interactive UPS (Uninterruptible Power Supply) specifically designed to protect your computer from any type of irregularities in the AC line (such as black-purs, over voltages, low voltage, micro-interruptions) which often cause damage to your Hardware and Software.
Under normal AC line condition, UPS ADJ HOME filters electrical disturbances (such as transients, spikes, interferonous, etc.) frequently present on the electrical line, thus protecting all devices connected to the outlets, and recharging the batteries in an ideal way.
case of anomaly to the AC line, the UPS continues feeding properly the connected devices.
The UPS general characteristics are:
• All functions are controlled by a microprocessor, giving full guarantee on high reliability.
• Overload protection both in normal functioning and in battery mode.
• High performance battery charger which extends the battery medium life ensuring an optimal recharge.
• Starts up even if the electrical network is not available.
• Adapts automatically to 50 or 60 Hz input frequency.
• Visual and acoustic signals indicating operating mode and alarm conditions.
• Compact dimension and smart design.
INSTALLATION
INSPECTION AND PLACEMENT CHOICE
Carefully remove the UPS from its packaging, and carry out a meticulous inspection. We recommend keeping the original packaging in case you need to send the UPS for maintenance purposes.
We recommend to pay attention to the below points in order to choose a correct placement for your UPS:
• Place UPS ADJ HOME as close as possible bath to the input electrical line and to the equipment to be supplied.
UPS ADJ HOME is designed to operate in protected environments (for example: offices). We therefore recommend installing it in a place with no humidity, dust, or smoke. However, for the environmental requirements please refer to the "Specifications" chapter, and check that the selected place meets with such specifications.
It is necessary to leave at least 20 cm of space all around UPS ADJ HOME in order to permit reasonable ventilation.
• Do not place any object on top of the UPS.
• Do not keep liquids, flammable gases, or corrosive substances near the unit.
INSTALLATION
For a correct installation please carry out the following points:
-
Switch your PC off.
-
Connect the UPS to an AC line outlet. It is mandatory to ground the outlet according to the Safety Standards. Carefully check the grounding, make sure that the utility power is available, and that its range falls within the UPS specifications (refer to the "specifications" chapter).
-
Turn the UPS ON (by pressing the button) and leave it in ON for at least 8 hours in order to completely re-charge the battery.
-
Switch the UPS OFF (by pressing again button).
-
Connect the devices to the UPS output socket and turn all the switches ON.
-
Restart the UPS; check that the power up performance takes place properly and that the UPS does not give any warning signals. Make sure that all devices are turned ON accordingly.
FUNCTIONING
SWITCH ON AND FUNCTIONING
In order to switch the UPS on, simply connect it to the electrical line using the supplied cable, and keep ON/OFF button on the top cover pressed for about 2 seconds. The UPS omits a brief acoustic signal, the 2 leds on the front panel flash and the LINE/BATTERY led switches on. UPS ADU HOVE begins working in "LINE" mode. In "LINE" mode the LINE/BATTERY led is always switched on.
ATTENTION: UPS ADJ HOME automatically switches to the BATTERY ("BATTERY" mode) whenever the Mains voltage amplitude is out of the safety limit (due to: black-out / surge / over / under voltage).
• ATTENTION: never power a laser printer or plotter on to your UPS: the laser printer or the plotter absorb a higher power than the one absorbed in waiting mode, and this may over change your UPS.
SWITCH OFF
To switch your UPS ADJ HOME OFF, it is enough to keep the ON/OFF button pressed for about 2 seconds.
ALARMS
"BATTERY" mode (slow alarm)
When UPS ADJ HOME works in "BATTERY" mode, it emits a sustained acoustic signal. The alarm stops as soon as the UPS returns to a normal "LINE" mode functioning.
ATTENTION: in "BATTERY" mode, the UPS emits an acoustic alarm signal every 4 seconds and simultaneously the LINE/BATTERY led flashes.
"LOW BATTERY" CONDITIONS (fast alarm)
When the UPS operates in "BATTERY" mode and the remaining autonomy of the battery is around 20%–30%, the UPS omits a sustained acoustic signal. If the AC utility line is not restored, the UPS continues working in "LOW BATTERY" condition, until it switches off due to battery exhaustion of energy.
ATTENTION: in "LOW BATTERY" condition, the UPS emits an acoustic alarm signal every 1 second and simultaneously the LINE/BATTERY Iod flashes.
"OVERLOAD" CONDITIONS
In case of "OVERLOAD", the UPS may automatically switch off, protecting itself from this anomalous situation. In this case, the user must reduce power within the specifications by disconnecting the appliances which cause the overload (please refer to the "Specifications" chapter).
TROUBLESHOOTING
| PROBLEM | POSSIBLE CAUSE HOW TO RESOLVE | |
| The UPS does not turn on. The lodc are off. | Front ON/OFF button | Press the front button continuously for at least 5 seconds |
| Battery is flat. Recharge the battery for at least 6 hours | ||
| Electronic board failure | Refer to Technical Service | |
| The UPS always function in "BATTERY" mode | Input mains power cable is disconnected | Check the input mains power cable |
| Input mains fuse is burnt | Replace the fuse with another of the same type | |
| Back-out conditions / surge/ Over-or Under voltage | Wait until utility power returns to normal conditions | |
| Electronic board failure | Refer to Technical Service | |
| Battery Autonomy is too short. | Battery is not fully charged | Recharge the battery for at least 6 hours |
| Electronic board failure | Refer to Technical Service | |
| Continuing Acoustic signal and rod ALARM load on | The product is damaged | Refer to Technical Service |
SERVICE : WWW.ADJ.IT

UPS ADJ HOME can not be treated like urban waste; it must be addressed to the separate refuse collection; the violation of this disposal will be punished with pecuniary sanctions according to the legislation in force.
SI CONSIGLIA DI LEGGERE ATTENTAMENTE QUESTO MANUALE E CONSERVARLO!
Technical data may change without prior notice

LEAD BATTERIES
UPS ADJ HOME contains lead acid, sealed, maintenance free batteries.
This kind of batteries, if handled by non-experienced personnel, can cause electric shock or short-circuits.
For this reason the batteries can be removed only by qualified technical personnel, specialized and authorized by the producer. The producer declines any responsibilities if this rule is not followed.
To remove the batteries, firstly you have to take off UPS cover, disconnect batteries and take them off from their housing.
The batteries cannot be disposed as an urban waste, but must be treated in conformity with 2006/66/CE European Directive; any violation is indoltable with financial sanctions as established into 2006/66/CE European Directive.
CE
EUROPEAN DIRECTIVES CONFORMITY
CE
The producer confirms that UPS ADU HOME models comply with the requirements set out in: the Low Voltage Directive (Safety) 2006/95/EC and following amendments, the EMC (Electro-Magnetic Compatibility) Directive 2004/108/EC and following amendments. The following standards were applied:
The following standards were applied: Low Voltage Directive (Safety): EN62043-1-1: 2003
EMC Directive (Electro-Magnetic Compatibility): IEC62040-2: 2001, IEC61000-3-2: 2001, IEC61000-3-3: 2001, EN55022: 1998, IEC61000-6-4: 2001
CARATTERISTICHE TECNICHE
① Power Switch
② UPS status indicator
③ Fault/Battery status
indicator (Check the Indicator & Alarm Table for the details.)

① AC input
② Output sockets
③ Input fuse

computer and peripherals