Product Type Logic/control interface for low voltage studio tally lights
Brand Henry Engineering
Model SuperLight
Dimensions (W x D x H) 5.75" x 3.25" x 2.0"
Weight 1 lb
Power Supply 12 VDC wall transformer (included)
Control Input Voltage 5-24 VDC (maintained) or GPI ground closure
Control Input Type Opto-isolated, polarity sensitive
RJ45 Control User-assignable pin-outs via onboard jumpers (J5, J6)
Tally Light Output (Direct) 12 VDC, 500 mA max
Tally Light Output (External) Up to 30 VDC @ 2A (using external power)
Output Sink Capability Up to 2A with external power source
Flasher Circuit Built-in; can be disabled via jumper J8
Relay Output DPDT dry contacts, 24 VDC @ 1A max (not for AC line voltage)
Connectors Euroblock for control/relay/tally; two RJ45 for control
Loop-Through Capability Multiple units can be daisy-chained via RJ45
LED Output Polarity Observe polarity; LED+ and LED- terminals
Safety Note Use only with supplied power; do not switch AC line voltage with relay
Revision Rev. A: 1/2020

Frequently Asked Questions - SuperLight Henry Engineering

How do I connect the SuperLight to control inputs?
Use the euroblock connectors: remove 1/8" insulation, insert wires, tighten screws. For DC voltage control, connect voltage to IN+ and IN- (5-24V). For ground closure, jumper 12V to IN+, and connect ground closure between IN- and G terminals.
What power supply does the SuperLight require?
It comes with a 12 VDC wall transformer. Do not use other power sources.
How much current can the tally light output supply?
Direct output: 12 VDC at 500 mA. With external power: up to 30 VDC at 2A.
Can I disable the flashing feature?
Yes, set jumper J8 to OFF to make the tally light stay on solid.
How do I assign RJ45 pin-outs?
Open the unit, locate headers J5 and J6 on the PCB. Install jumpers to assign wires to IN+ and IN- respectively.
Can multiple SuperLight units be controlled with one cable?
Yes, the two RJ45 connectors are wired in parallel for loop-through. Multiple units can have same or different pin-outs.
What is the relay output specification?
DPDT dry contacts, rated for 24 VDC at 1A. Do not use to switch AC line voltage.
How do I connect an external power source for the tally light?
Connect + of external supply directly to light's +, ground of supply to G terminal, and light's negative to LED- terminal.
What are the dimensions and weight?
5.75" x 3.25" x 2.0" (WxDxH), weight 1 lb.
Is the control input isolated?
Yes, the DC voltage input is opto-isolated, ensuring electrical isolation.

User questions about SuperLight Henry Engineering

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual SuperLight - Henry Engineering and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SuperLight by Henry Engineering.

USER MANUAL SuperLight Henry Engineering

SUPERLIGHT is a logic/control interface for controlling low voltage studio tally lights. It can directly power 12 volt DC LED tally lights that draw up to 500 mA. SuperLight includes a flasher circuit, as well as a DPDT relay output that can be used for any low voltage switching, speaker muting, or other utility use.

The LED output can supply 12 vdc at up to 500 ma; it can also "sink" up to 2 amps if used with an external power source. The LED output can be set to "flash" when ON for use with ON THE AIR warning lights. All control, relay output, and LED output connections are via plug-in euroblock connectors. Two RJ45 connectors are also provided for Control wiring compatibility with WheatNet-IP Blade and similar installations that use cat5/cat6 wiring.

INSTALLATION

Connection to Control inputs and Relay outputs is via the euroblock connectors. Remove about 1/8" of the insulation, insert wires into the connector, and tighten the screws. Be sure that no bare wires are exposed.

EUROBLOCK CONTROL INPUT: SuperLight can be controlled with a maintained DC voltage or ground closure.

For control with a DC voltage: SuperLight can be switched on by applying a DC voltage to the IN+ and IN- terminals. Any DC voltage between 5 and 24 volts will switch the unit ON. This input is opto-isolated. Observe polarity.

For control with a ground closure: Connect a jumper between the 12V and IN+ terminals. Connect an external ground closure between the IN- and G terminals. A ground closure will switch the unit ON. NOTE: If the ground closure is provided by a transistor "open collector", connect the open collector to the IN- terminal, and connect the emitter to the G terminal.

RJ45 CONTROL INPUTS: Two parallel RJ45 connectors are provided for controlling the SuperLight. The pin-outs can be assigned by the user to be compatible with any cat5/cat6 wiring scheme. To assign pin-outs, open the unit by removing the screws on the top cover. Locate the J5 and J6 multipin headers on the PC board.

Install one jumper on J5 to assign an RJ45 wire to the IN+ control input; install one jumper on J6 to assign an RJ45 wire to the IN- control input. Applying a maintained DC voltage (5-24v) to these two wires will switch the SuperLight ON.

The two RJ45 connectors are wired in parallel so that cat5/cat6 cabling can be "looped-thru" the unit. This allows multiple SuperLight units to be controlled with a single cable. Multiple SuperLight units can have the same or different RJ45 pin-outs as needed.

TALLY LIGHT OUTPUT: SuperLight can directly power tally lights that require 12 vdc, 500 ma or less. Connect the tally light to the SuperLight LED+ and LED- terminals. Observe polarity.

For tally lights that require more than 12 vdc or 500 mA*, use an external power source connected as follows: Connect the + voltage source directly to the + wire of the light. Connect the ground of the power source to the G terminal of the SuperLight, and connect the - wire of the light to the LED- terminal on the SuperLight. *30 vdc, 2 amp maximum.

FLASH DISABLE: For installations where the tally light should stay ON "solid" (not flashing), set jumper J8 to OFF.

RELAY OUTPUT: SuperLight provides DPDT relay contacts for utility use. The C and NO terminals are active when then unit is ON; the C and NC terminals are active when the unit is OFF. The relay can switch up to 1 amp at 24 volts DC. (Do NOT use these relay outputs to switch AC line voltage!)

SPECIFICATIONS

Control Inputs: Maintained 5-24 VDC or GPI closure

RJ45 Control: Maintained 5-24 VDC, user assignable

Tally Output: 12 VDC, 500 mA max.

Ext. Tally Pwr: 30 VDC @ 2A max.

Relay Output: DPDT dry contacts, 24 VDC @ 1A max.

Power: 12 VDC wall transformer supplied

Size, weight 5.75"w X 3.25"d X 2.0"h, 1lb Rev. A: 1/2020

Henry Engineering SuperLight - SPECIFICATIONS - 1

Henry Engineering SuperLight - SPECIFICATIONS - 2

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Henry Engineering

Model : SuperLight

Category : Uncategorized