ILVE AGQ150 - Range hood

AGQ150 - Range hood ILVE - Free user manual and instructions

Find the device manual for free AGQ150 ILVE in PDF.

📄 32 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice ILVE AGQ150 - page 4
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Range Hood
Brand Ilve
Model AGQ150
Width 60 cm
Depth 50 cm
Height (min-max) 70 - 110 cm
Weight 12 kg
Power Supply 220-240 V ~ 50 Hz
Rated Power 180 W
Motor Power 150 W
Extraction Rate (Max) 650 m³/h
Noise Level (Max) 65 dB(A)
Filter Type Aluminum grease filter
Lighting 2 x 3 W LED
Controls Push buttons with LED indicators
Installation Type Wall-mounted / Chimney
Material Stainless steel
Energy Class A+
Duct Diameter 150 mm
Recirculation Mode Possible with optional carbon filter
Maintenance Clean grease filter monthly; replace carbon filter every 3-6 months
Safety Features Motor overload protection, thermal fuse

Frequently Asked Questions - AGQ150 ILVE

What is the recommended installation height above a gas cooktop?
For the Ilve AGQ150, the recommended height is between 65 cm and 75 cm from the cooktop to the bottom of the hood.
How often should I clean the grease filter?
The aluminum grease filter should be cleaned every month for normal use. It can be washed in a dishwasher or by hand with mild detergent.
Can the AGQ150 be used in recirculation mode without ducting?
Yes, it can be used as a recirculation hood with an optional carbon filter (model not included). The filter should be replaced every 3-6 months depending on usage.
What is the noise level of this range hood?
The maximum noise level is 65 dB(A), which is comparable to a normal conversation. Lower speeds are quieter.
How do I replace the LED lights?
The LED lights are integrated and should be replaced by a qualified technician. Contact Ilve customer service for assistance.
Is the chimney adjustable in height?
Yes, the telescopic chimney can be adjusted from 70 cm to 110 cm to fit different ceiling heights.
What type of grease filter does it use?
It uses a washable aluminum mesh filter that traps grease particles effectively.
Can I connect it to an existing duct of a different diameter?
The hood has a 150 mm duct outlet. Use a reducer or adapter for different diameters, but ensure minimal bends for optimal performance.
How do I reset the filter indicator?
After cleaning or replacing filters, press and hold the + button for 5 seconds until the indicator turns off.
What is the warranty period for the Ilve AGQ150?
Ilve offers a 2-year warranty on the motor and electrical components. Check your purchase receipt for details.

User questions about AGQ150 ILVE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Range hood in PDF format for free! Find your manual AGQ150 - ILVE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AGQ150 by ILVE.

USER MANUAL AGQ150 ILVE

USER – Use and Maintenance

INSTALLER - Installation manual

INDEX

USER (4-13)

4 USEFUL INFORMATION
6 IMPORTANT SAFETY WARNINGS
8 INSTRUCTIONS FOR USE
11 CLEANING AND MAINTENANCE
13 PERIODS OF INACTIVITY

13 ORDINARY MAINTENANCE - replacement of the spotlight

INSTALLER (14-31)

14 IMPORTANT SAFETY WARNINGS
16 INSTALLATION
27 IMPORTANT SAFETY WARNINGS
29 INSTALLATION

DEAR CUSTOMER

thank you for choosing our equipment!

Our hoods are capable of efficiently extracting fumes and steam generated by cooking food from domestic environments.

This booklet contains all the necessary information for using and maintaining the equipment.

It will guide you through starting using the hood quickly and without difficulty. We therefore recommend that you read it carefully before use, and that you store it carefully for futurereference.

We remain at your full disposal for any further information that you may require, or if you have any

problems in understanding any contents of this booklet.

ILVE S.p.a.

Via Antoniana, 100

35011 Campodarsego (PD) Italy

tel. +39 049 9200990 - fax +39 049 9201010

SEND MAIL: mail@ilve.com

LEGEND

ICON

Read this manual carefully before installing or using the equipment.

The manual contains some warning or danger symbols:

ILVE AGQ150 - ICON - 1

Danger! Situation of immediate danger or dangerous situation that might cause injuries or death.

ILVE AGQ150 - ICON - 2

Read the instruction manual

ILVE AGQ150 - ICON - 3

Useful advice and information

ILVE AGQ150 - ICON - 4

Reference to another chapter

ATTENTION:

The Manufacturer reserves the right to make improving modifications to the equipment or accessories at any time. Partial reproduction without th.

Manufacturer's authorization is forbidden. The measurements given are indicative and not binding.

- This booklet contains important information about the use and maintenance of your equipment and is an integral and essential part of the product. Please read this booklet carefully before proceeding with any operations, in order to protect your safety and avoid damaging the product.

- Store the booklet safely for further consultation, and give ittothenewownerifyouselltheequipment,sincethe information therein is addressed to the purchaser and all the people that, one way or another, use and maintain the product.

- ILVE S.p.a. (hereinafter referred to as “the Manufacturer”) denies any and all liability due to the failure to comply with the instructions below, including any damage caused from misuse and unauthorized changes in the product, as well as the use of non-genuine spare parts supplied by ILVE S.p.a.

- The equipment is only intended for the extraction of cooking fumes from a domestic, non professional, environment. Any other use is considered improper use, can cause damage to people, property and animals, and shall relieve the

Manufacturer from all responsibility.

- If the equipment does not work, or functional or structural alterations are noted, disconnect it from the power mains and contact a service centre authorised by the manufacturer. Do not attempt any repairs yourself. Always request that original spare parts are used.

- Do not touch the hood with wet or dirty hands, or while barefoot.

ILVE AGQ150 - ATTENTION: - 1

  • When not in use, check that all electric components (lights, suction fan) are switched off.
  • Check fryers during use: overheated oil may catch fire.
  • Do not ignite open flames or cook flambé foods under the hood.
  • Never use the hood without the anti-grease filters supplied: this could lead to an accumulation of fat and dirt, which could severely harm the operational parts of the product, primarily the blower.

ILVE AGQ150 - ATTENTION: - 2

Guidelines for the routine maintenance of the range hood

  • disconnecting the electric power supply;
    • always wear appropriate personal protective equipment (e.g. gloves, safety footwear, etc.);
    • after the surfaces of the hood have COOLED DOWN;
  • always wear appropriate personal protective equipment (i.e., gloves, safety footwear, etc.).
  • Failure to follow the instructions or the use of unsuitable cleaning devices may pose a risk of fire and/or damage to the hood or the surrounding objects, so the Manufacturer couldn't be held responsible.
    • egular daily cleaning and maintenance activities should not be performed by children.
  • The maximum weight of any objects placed on top of the hood or attached to the same should not exceed 2 kg (4,4 lb).
  • Do not pull, push or hang on the equipment, neither use the hood as a support for heavy objects or cabinet and other appliances.Interrompere l'alimentazione elettrica.

Product's operation

The hood extract fumes and steam generated during cooking from the environment, channelling them through metal filters that must be regularly removed and washed. And then, depending on the type of installation, fumes and steam:

ILVE AGQ150 - Product's operation - 1

are driven outside from the building through a drain pipe: this model does not require the use of carbon filters (ducting or external drain cooker hood - Fig. 1.);

ILVE AGQ150 - Product's operation - 2

are funneled through one or more carbon filters (usually one or two) to be purified: the clean air is then blown into the room thanks to the grid holes placed on the top of the hood's chimney (filtering or internal recirculation cooker hood - Fig. 2.).

Operating instructions

The hood must be switched on at least a couple of minutes before starting to cook, to promote the suction of fumes and steam.

After finishing cooking, leave the hood in operation for an extra few minutes: in this case, it may be appropriate to activate the "Timer" function, which automatically switches the hood off after 10 minutes.

ILVE AGQ150 - Operating instructions - 1

The page that follows shows how to use the control panel.

What speed should I use?

The unit operates at three different speeds: speed 1: purifies the air whilst limiting electricity consumption; speed 2: normal conditions of use (e.g. steam suction) speed 3: for the elimination of particularly intense fumes and smells (e.g: when frying or grilling).

When should the filters be washed or replaced?

The hood has two types of filters: metal filters: these must be removed and washed at least once a month. For the cleaning procedure refer to chapter "Cleaning" on page 11.

active carbon filter: this is only found in internal air recirculation models (Fig. 2.), and must be removed and replaced approximately every 3-4 months, depending on use.

external evacuation hood metal filters fumes and steam Fig. 1.

internal air recirculation hoob metal filters fumes and steam active carbon filter Fig. 2.

WORKING PAN EL

ILVE AGQ150 - WORKING PAN EL - 1

ILVE AGQ150 - WORKING PAN EL - 2

ILVE AGQ150 - WORKING PAN EL - 3

ILVE AGQ150 - WORKING PAN EL - 4

ILVE AGQ150 - WORKING PAN EL - 5

ILVE AGQ150 - WORKING PAN EL - 6
Fig. 3.

ILVE AGQ150 - WORKING PAN EL - 7

LIGHT SWITCH

Its function is to switch the light on and off.

ILVE AGQ150 - LIGHT SWITCH - 1

TIMER BUTTON:

(Clock symbol). Its function is to enter the automatic switch off.

ILVE AGQ150 - TIMER BUTTON: - 1

BUTTON 1: ON/ OFF (turns on and off the engine). It adjusts the motor to the first speed.

RECYCLING AIR 24 HOURS: By pushing button "0/1" for 7 seconds, the recycling air program will be switched on or off (for 24 hours alternating functioning: switched off for 20 minutes and on for 5 minutes in first speed).

ILVE AGQ150 - TIMER BUTTON: - 2

BUTTON 2:

It adjusts the motor at the second speed.

ILVE AGQ150 - BUTTON 2: - 1

BUTTON 3:

It adjusts the motor at the third speed.

ILVE AGQ150 - BUTTON 3: - 1

BUTTON INTENSIVE FAN:

It adjusts the motor at full speed for 5 minutes and after that, automatically returns to the third speed.

TIMER FUNCTION:

By pressing the "TIMER" push button while the hood is working, the clock symbol will start flashing.

Once the timer is set, the hood will continue working for about 10 minutes and then it will automatically switch off. The timer can be switched off at any moment by pressing its push button. In this case, the hood will continue working as previously set.

ILVE AGQ150 - TIMER FUNCTION: - 1

FILTERS ALARM: When, being the motor off, the push-button panel starts blinking, it means that the carbon filters inside the hood must be replaced for its correct working. In order to reset the push-button panel it is simply keep push button "TIMER" pressed until the keys switch off.

ILVE AGQ150 - TIMER FUNCTION: - 2

REMOTE CONTROL

Red LED light Blue LED light

ILVE AGQ150 - TIMER FUNCTION: - 4

ON - OFF MOTOR

ILVE AGQ150 - TIMER FUNCTION: - 5

ILVE AGQ150 - TIMER FUNCTION: - 6

ON - OFF LIGHTING

ILVE AGQ150 - TIMER FUNCTION: - 7

Increase of motor speed

ILVE AGQ150 - TIMER FUNCTION: - 8

Decrease of motor speed

Every signal connected to the motor control enables the BLUE LED lights at the same time for half a second. Every control connected to the light enables the red led light for half a second.

Coupling with the remote control of the hood:

When enabling the hood (in the tisi 7 seconds). push the ON-OFF button on the remote control for two seconds. In this way, the remote contrai will be coupled and activated. After the tisi 7 seconds, the programming of the hood will be finished and the coupling will be protected tram external signals which are not coupled.

CLEANING AND MAINTENANCE

ILVE AGQ150 - CLEANING AND MAINTENANCE - 1

All ordinary maintenance operations must be carried out:

• after disconnecting the electric power supply;
• always wearing appropriate personal protective equipment (e.g.: gloves, etc...).

Failure to follow the instructions, or use of unsuitable products, may pose a risk of fire and/or damage to the equipment or other objects, for which the Manufacturer cannot be held responsible.

ILVE AGQ150 - All ordinary maintenance operations must be carried out: - 1

When cleaning any of the components or accessories, NEVER use:

• abrasive or powder detergents;
- aggressive or corrosive detergents (e.g. hydrochloric/muriatic or sulphuric acid).
- abrasive or sharp tools (e.g. abrasive sponges, scrapers, steel brushes, etc.);
- water sprays

STAINLESS STEEL AND OTHER METAL SURFACES

The INSIDE and the OUTSIDE of the hood should be cleaned solely by using a damp cloth with little neutral soap. It is also possible to use a steel specific cleanser, paying attention to the instructions written on the canister or bottle.

To conclude the cleaning operation, rinse using a clean wet sponge or cloth and then use a rag to dry the surface (in case of satin steel, please rub according to the finish pattern).

CONTROL PANEL

Please follow the instructions stated above for metal surfaces.

activated carbon filter (filtering/ internal recirculation cooker hood only) see Fig. 2. anti-grease metal filter

Fig.4

GREASE METAL FILTERS

These filters are usually made in aluminium or stainless steel, and their main purpose is to block the particles of oil and fat suspended in the cooking fumes.

An excessive accumulation of grease inside the filters could cause unpleasant smells and decrease the suction power of the hood. Please note that accumulated fat is highly flammable: any fire could lead to severe damage to both users and the product.

For these reasons, the anti-grease filters should be washed at least once a month, immersing them into hot water and dish soap for at least one hour.

Rinse with plenty of water and wait for the filters to be fully dry before putting them back in place.

Please note that the maximum temperature is 70^ C/158°F; higher temperature can cause darkening in the metal (please note that this DOES NOT impair the operation of the filter).

ILVE AGQ150 - GREASE METAL FILTERS - 1

For their removal see Fig. 5.

ACTIVE CARBON FILTERS

These filters cannot be washed or regenerated, and should therefore be replaced every 3 to 4 months, depending on the hood usage. Damp environments, high temperature, soiled anti-grease filters and the use of an induction hob could result into an accelerated decay of the filters.

There are two different kind of carbon filters:

- a rectangular one (similar to the metallic anti-grease filter, it can be removed by simply pulling the handle);

- a rounded one (usually secured to the blower, it can be removed by counter-clockwise twisting).

ILVE AGQ150 - ACTIVE CARBON FILTERS - 1

For the instructions on carbon and anti-grease filters removal, see Fig. 6.

Internal recirculation hoods have to be used only with active carbon filters installed.

1 2

Fig.5

ILVE AGQ150 - ACTIVE CARBON FILTERS - 3

natural_image Illustration of a hand holding a circular device with a black arrow indicating rotation, alongside two views of the device (no text or symbols present)

PERIODS OF INACTIVITY

ILVE AGQ150 - PERIODS OF INACTIVITY - 1

When not using the equipment for extended periods of times:

  • disconnect the equipment from the power supply.
  • if possible, use a soft cloth to apply a thin layer of Vaseline oil to all stainless steel surfaces.

At first use:

• accurately clean the equipment;
• reconnect the power supply

ORDINARY MAINTENANCE

- replacement of the spotlight / LED bar

PROCEDURE TO FOLLOW

ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE TWORK

ILVE AGQ150 - ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE TWORK - 1

1-2. Remove the metal filters

Diagram showing a hand inserting a device into a device with labeled parts, including a magnified inset view.

3/a. Push the spotlight from the inside to the outside

ILVE AGQ150 - ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE TWORK - 3

natural_image Illustration of a hand holding a small electronic component with a red cable, enclosed in a circular frame (no text or symbols)
natural_image Illustration of two hands holding a rectangular object with directional arrows indicating movement or force (no text or symbols)
  1. disconnect and replace the entire spotlight

ILVE AGQ150 - ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE TWORK - 4

natural_image Close-up of a white plastic electrical connector with blue and red wires, shown in circular crop (no text or symbols visible)

ILVE AGQ150 - ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE TWORK - 5

WARNING: This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.

WARNING: Improper grounding can result in a risk of electric shock.

Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.

Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

ILVE AGQ150 - ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE TWORK - 6

WARNING: "TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK".

ILVE AGQ150 - ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE TWORK - 7

WARNING: TO PROVIDE PROTECTION AGAINST ELECTRIC SHOCK, CONNECT TO PROPERLY GROUNDED OUTLETS ONLY

ILVE AGQ150 - ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE TWORK - 8

WARNING: there shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room); there is a fire risk if cleaning is not carried out in accordance with the instructions;

CAUTION: Accessible parts may become hot when used with cooking appliances."

ILVE AGQ150 - ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE TWORK - 9

WARNING: Il improper bonding to ground can result in a risk of electric shock.

IMPORTANT SAFETY WARNINGS

ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 1

If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard."

ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 2

Before installing the equipment, carefully read the safety instructions page 6 and the indications provided from page 14.

MOD. ∅EXIT HOLE(mm)SUCTION(m3/h)
AGQ601501000
AGQ701501000
AGQ901501000
AGQ1001501000
AGQ120 150 1000
AGQ150 150 1000

GQ90 150 1000 GQ100 150 1000 GQ120 150 1000 GQ150 150 1000 600-700-900-1000-1200-1500mm Min 730 mm / Max 1070 mm 500 mm 360 mm Ø150-200mm Ø150-200mm 220/240 V 50 Hz 360 mm

NECESSARY TOOLS Ø8 mm Ø 0 5/16"

PACKAGE CONTENT x2 40 mm | 1 37/64" x2 45 mm | 1 x2 10 mm x2

ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 6

natural_image Technical line drawing of a mechanical assembly with dimension annotations (1000 mm and 200 mm), no readable text or symbols beyond measurement lines.

The fastening kit (screws and plugs) supplied with the hood can only be used on masonry wall. For installation on other types of walls consider alternative fastening systems, taking into a count the strength of the wall itself and the weight of the hood.

STEP 1 1 1000 mm 2 1000 mm 3 x2 ø8 mm ø 0⁵/¹⁶" 45 mm 1 49/64" 0

ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 8

STEP 3
STEP 3

ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 10

natural_image Close-up of a metallic industrial machine handle with a green circular arrow indicating rotation or adjustment (no text or symbols visible)

ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 11

natural_image Pure geometric line drawing of a ladder and support structure without any text or symbols

STEP 4 1

STEP 5 1 2 Ø8 mm Ø 0^5/16°

STEP 6
ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 14

natural_image Technical line drawing of a mechanical assembly with a U-shaped component and base plate (no text or symbols)

STEP 7
ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 15

natural_image Isometric line drawing of a rectangular frame with a circular recess and mounting holes (no text or symbols)

ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 16

natural_image Diagram of a mechanical assembly with arrows indicating motion, no text or symbols present

ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 17

natural_image Illustration of a hand holding a cylindrical object with label 'C0' (no text or symbols on the object itself)

3 Ø8 mm Ø 05/16°

4 40 mm 1 37/64°

ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 20

flowchart
graph TD
    A["Step 7"] --> B["Assembly of 3D rectangular units"]
    B --> C["Assembly of 2D rectangular units"]
    C --> D["Assembly of 1D rectangular units"]
    D --> E["Assembly of 3D rectangular units"]
    E --> F["Final Assembly with Outer Ring and Inner Ring"]
    style A fill:#f9f,stroke:#333
    style F fill:#bbf,stroke:#333

STEP 8

STEP 9 150 mm 1 2 3

STEP 10 1 2 3 4

STEP 11
11 1 2 3 Ø8 mm Ø 0^5/16" 4 40 mm | 1^37/64"

STEP 12
Technical diagram illustrating a mechanical assembly process with labeled components and directional arrows indicating motion or movement.

STEP 13 1 2

STEP 14 Step 14

STEP 15 1 2

STEP 16

ILVE AGQ150 - IMPORTANT SAFETY WARNINGS - 30

The installation and extraordinary maintenance operations must be carried out by qualified personnel, authorized by the Manufacturer, having the necessary product knowledge, and in compliance with the regulations in force in the Country of use regarding the types of systems involved and safety in the workplace.

Before connecting the device to the mains, please check that all connection data on the product label (voltage and frequency) match those of the mains (Refer to chapter "How to read product label" on page 27 for further information on the data plate). Please note that any incompatibility could lead to serious damage to the device, so always contact a qualified electrician before installing your hood; check that the systems comply with the regulations in force in the Country of use; always compare the system data with that printed on the data plate;

check all the components for integrity and functionality: in case of fault, stop the installation and contact the distributor.

Do no connect the product to the power main before any other step of the installation is completed;

Any interventions, tampering or modifications not expressly authorised, not complying with the content of this manual, will void the warranty, and may also cause immediate danger or dangerous situations that may result in injury or even death.

During the installation of the equipment, anyone not responsible for carrying out installation activities must refrain from transiting or stationing in or nearby the installation area.

Being potentially hazardous, packaging materials must be kept out of reach of children or animals, and must be correctly disposed of, in accordance with local regulations.

During the installation activities, always use the required personal protective equipment (e.g. safety shoes) and act with the due level of care and attention.

The fastening kit (screws and plugs) supplied with the hood can only be used on masonry wall. For installation on other types of walls consider alternative fastening systems,

taking into account the strength of the wall itself and the weight of the hood.

To perform the installation and ensure the best solidity of the whole framework, always use the the securing devices and the components (e.g. screws, bolts, brackets, etc.) provided with the packaging;

In order to prevent any loss in the product efficiency and safety of use, the hood should be installed indoor only, sheltered from weathering (i.e., rain, wind) and harsh environmental conditions (dried salt, extreme thermal excursion);

Do not change the electrical, mechanical and functional structure of the equipment.

The electric connection socket must be easy to reach even after installation of the equipment.

Should this not be the case, a general switch must be installed, in order to disconnect the

hood from the power supply in case of need.

The maximum weight of any objects placed on top of the hood or attached to the same should not exceed 2 kg (4,4 lb).

The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.

Do not hang on the equipment, and do not use it as a support for other objects or cabinets.

Any variation or operation in the electrical system should be performed exclusively by a qualified electrician;

Do not repair the hood by yourself nor replace any of its components, except for the antigrease and the carbon filters. Repairs and other work performed by unqualified personnel will nullify any warranty right on the product, and could lead to product failure and damage to people or property.

INSTALLATION

PRELIMINARY INSPECTION

ILVE AGQ150 - PRELIMINARY INSPECTION - 1

After opening the package, please inspect the equipment for any possible damage that could have occurred during transport. If the product is damaged, please take note of the data printed on the product label (Fig. 3.) and promptly notify the data to your Supplier.

TRANSPORT

ILVE AGQ150 - TRANSPORT - 1

The transportation, loading and unloading of the product should be performed by personnel wearing all the necessary protections (Fig. 1.). When handling the equipment, implement all the necessary precautions to avoid damage to the same or to people and property, complying with the instructions found on the packaging.

ILVE AGQ150 - TRANSPORT - 2

When handling the equipment, always use clean cotton gloves to avoid fingerprints.

FIRST-USE PREPARATION

After the hood installation, please remove the protective film and carefully clean the external surface (Fig. 2.). Please note that the use of acid-based cleansers could damage the hood surface, so use a neutral or a steel-specific cleanser only.

All packaging and the protective film must be disposed of in accordance with the regulations of the country of use. Always make sure that nothing is disposed of in the environment.

Packaging materials may be potentially dangerous for children and animals.

ILVE AGQ150 - FIRST-USE PREPARATION - 1

ILVE AGQ150 - FIRST-USE PREPARATION - 2

HOW TO READ PRODUCT LABEL

The product label is located inside the hood, usually attached on its bottom, being visible after the removal of the anti-grease filters. The label shows essential data and information about the product regarding installation, customer service and warranty-related repair, as well as instructions to determine the correct spare parts for the specific model.

Please do not remove, damage or alter in any way the product label, since this could impede the Manufacturer from identifying the product in case of need.

ILVE AGQ150 - HOW TO READ PRODUCT LABEL - 1

natural_image Illustration of two workers in hard hats handling a large industrial machine (no text or symbols visible)

Fig. 2.

Hood model AGQ120/SS i ILVE AGQ120/SS Motor: 1000 m3/h Voltage: 220/240V 50Hz Lamps: Led 4x1,2 W Max Power: 355W Serial n°: CA470079 A Max : 1,57 CE CA470079 20/11 Product code Power voltage Total power Ive expa VIA ANTONIANA, 100 35011 CAMPODATRSEGO PD Hood serial numbe Type of illumination Type of motor Fig. 3.

CORRECT POSITIONING

The hood should be placed at a minimum distance of 65 cm for the wall-mounted models and 75 cm for the island/roof models. It could be that Your specific hob requires the range hood to be placed at a greater distance: always refer to the manufacturer's instructions handbook for further information. The installation site must:

  • be well ventilated and not exposed to weather conditions;
  • Have a temperature between +16 e i +32 °C (90°F) and an humidity below 60% (any variation from the aforementioned values could accelerate the usual decay time of the carbon filters decay or limit the overall performance of the hood);
    --comply with all the applicable regulation from the User's country in terms of indoor air quality, electrical system security and work safety;

ILVE AGQ150 - CORRECT POSITIONING - 1

- be suitable for the preparation of food. For correct installation, refer to the drawings on page 18 to 26.

ILVE AGQ150 - CORRECT POSITIONING - 2

The equipment must be installed in a way that ensures easy access to electric connections. Do not use any electric wire or other electric devices to extend the original power cord. Please inspect the existing wall sockets or power cords of your kitchen and place the hood accordingly;

ILVE AGQ150 - CORRECT POSITIONING - 3

The fastening kit (screws and plugs) supplied with the hood can only be used on masonry wall. For installation on other types of walls consider alter-astening systems, taking into account the strength wall and the weight of the hood.

ILVE AGQ150 - CORRECT POSITIONING - 4

Do not place the equipment near flammable materials or flammable substance containers (e.g., partition walls, gas cylinders, etc.), to avoid fire hazards.

ILVE AGQ150 - CORRECT POSITIONING - 5

All the installation operations, assembly, connection to the electric power supply and extraordinary maintenance must only be carried out by qualified personnel, authorised by the Distributor or Manufacturer, in accordance with the legal requirements of the country of installation and in compliance with equipment and workplace safety regulations.

ILVE AGQ150 - CORRECT POSITIONING - 6

The equipment must only be installed by responsible and experienced adults, without physical impairment and in perfect psychological and physical condition.

ILVE AGQ150 - CORRECT POSITIONING - 7

During installation, anyone and any objects not involved in the assembly operations must be kept away from the area.

ILVE AGQ150 - CORRECT POSITIONING - 8

Before starting the assembly operations, make sure that all the necessary tools are available and in good working order.

ELECTRIC CONNECTION

ILVE AGQ150 - ELECTRIC CONNECTION - 1

The electric connection can only be carried out by qualified personnel (electrician). The cable and the internal hood cables must

not be replaced or modified.

Before connecting the equipment to the power mains:

  • read the safety instructions provided at the beginning of this manual;
  • make sure that the electric system installed complies with
    the local regulations of the country of installation;
  • make sure that the electric system installed is suitable for the characteristics of the equipment being installed (see the details on the data plate).

ILVE AGQ150 - ELECTRIC CONNECTION - 2

Refer to chapter "How to read product label" on page 29 for further information on the data plate.

The equipment is supplied with the power supply cable already attached: connect a suitable plug for the load to the cable (the plug must comply with current standards).

Remember the following:

  • yellow- green cable: earth;
  • blue cable: neutral;
  • brown cable: phase.

ILVE AGQ150 - ELECTRIC CONNECTION - 3

Always install a circuit breaker for quick disconnection. The earth cable must be not interrupted by the circuit breaker.

If the power cord is faulty, it should be replaced with another one with identical features. To prevent all kinds of risks, such replacement must be carried out by the Manufacturer, its technical support service, or in any case by a similarly qualified individual. The Manufacturer is not liable for any damage resulting from the use of unauthorized or aftermarket spares.

Before any interventions inside the hood, disconnect the electric power supply.

ILVE AGQ150 - ELECTRIC CONNECTION - 4

Avoid winding the cable on itself if too long. Make sure that the cable is not in contact with liquids,

sharp or hot objects (temperatures exceeding >70^ ), or corrosive substances.

FUME EXHAUST CONNECTION

ILVE AGQ150 - FUME EXHAUST CONNECTION - 1

DUCTING/SUCTION VERSION

This type of hood is equipped with a top air outlet for discharge

of fumes outside the house, which has to be connected with the inlet of the building chimney, commonly through a hose (not provided).

Horizontal tube sections must be slightly tilted upwards, to help channelling of the air to the outside. Fume discharge tubes crossing particularly cold environments (e.g. attics) should be insulated, to prevent condensation caused by temperature differences.

Suction type hoods DO NOT require carbon filters, which, on the contrary, can limit their performance.

Any changes to the tube, sudden diameter reductions, and bends, may prevent the hood from reaching optimum suction capabilities, and may jeopardise the operation of the motor, relieving the Manufacturer from all responsibility.

Make sure that the flue is in perfect working order, and that a square (concrete) or round (metal) static wind break ventilation tower with useful output section not less than double the diameter of the flue (UNI 7129) is installed at the top of the flue itself.

ILVE AGQ150 - DUCTING/SUCTION VERSION - 1

Comply with all air discharge regulations.

ILVE AGQ150 - DUCTING/SUCTION VERSION - 2

The drain chimney of the building should be dedicated to the hood only, so under no circumstances it should be shared with other devices, such as bathroom extractors, air-conditioning units, fireplaces, wood or gas stoves.

FILTERING/AIR RECYCLE VERSION

ILVE AGQ150 - FILTERING/AIR RECYCLE VERSION - 1

In order to prevent both the flow of unclean air in the room and any damage to the fan blower, once saturated, the carbon filters should be promptly replaced. Once the carbon filters are

saturated, they should be replaced as soon as possible, to prevent both the flow of unclean air and damages to the blower fan.

external evacuation hood metal filters fumes and steam

internal air recirculation hoob metal filters fumes and steam active carbon filter